Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

Diagnostic and prognostic potential of multiparametric renal MRI in Kidney transplant patients

  • Echeverría Chasco, Rebeca
  • Martín Moreno, Paloma L.
  • Aramendía Vidaurreta, Verónica
  • García-Ruiz, Leyre
  • Mora-Gutiérrez, José María
  • Vidorreta Díaz de Cerio, Marta
  • Villanueva Larre, Arantxa
  • Cano, David
  • Bastarrika, Gorka
  • Fernández Seara, María Asunción
Background: Multiparametric MRI provides assessment of functional and structural parameters in kidney allografts. Itoffers a non-invasive alternative to the current reference standard of kidney biopsy. Purpose: To evaluate the diagnostic and prognostic utility of MRI parameters in the assessment of allograft function in thefirst 3-months post-transplantation. Study Type: Prospective. Subjects: 32 transplant recipients (54 17 years, 20 females), divided into two groups according to estimated glomerularfiltration rate (eGFR) at 3-months post-transplantation: inferior graft function (IGF; eGFR<45 mL/min/1.73 m2,n=10) andsuperior graft function (SGF; eGFR≥45 mL/min/1.73 m2,n=22). Further categorization was based on the need for hemo-dialysis (C1) and decrease in s-creatinine (C2) at 1-week post-transplantation: delayed-graft-function (DGF:n=4 C1,n=10 C2) and early graft-function (EGF:n=28 C1,n=22 C2). Field Strength/Sequence: 3-T, pseudo-continuous arterial spin labeling, T1-mapping, and diffusion-weighted imaging. Assessment: Multiparametric MRI was evaluated at 1-week in all patients and 3-months after transplantation in 28 patients. Renalbloodflow (RBF), diffusion coefficients (ADC,ΔADC,D,ΔD,D*,flowing fractionf),T1andΔT1were calculated in cortex andmedulla. The diagnostic and prognostic value of these parameters, obtained at 3-months and 1-week post-transplantation,respectively, was evaluated in the cortex to discriminate between DGF and EGF, and between SGF and IGF. Statistical Tests: Logistic regression, receiver-operating-characteristics, area-under-the-curve (AUC), confidence intervals(CIs), analysis-of-variance,t-test, Wilcoxon-Mann–Whitney test, Fisher’s exact test, Pearson’s correlation.P-value<0.05 wasconsidered significant. Results: DGF patients exhibited significantly lower cortical RBF and f and higherD*. The diagnostic value of MRI fordetecting DGF was excellent (AUC=100%). Significant differences between patients with IGF and SGF were found inRBF,ΔT1, andΔD. Multiparametric MRI showed higher diagnostic (AUC=95.32%; CI: 88%–100%) and prognostic(AUC=97.47%, CI: 92%–100%) values for detecting IGF than eGFR (AUC=89.50%, CI: 79%–100%). Data Conclusion: Multiparametric MRI may show high diagnostic and prognostic value in transplanted patients, yieldingbetter results compared to eGFR measurements. Level of Evidence: 2. Technical Efficacy: Stage 1., This work was funded by Government of Navarra, Grant Num-ber: PC181-182 RM-RENAL. Rebeca Echeverria-Chasco received PhD grant support from Siemens Healthcare Spain.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

A deep learning image analysis method for renal perfusion estimation in pseudo-continuous arterial spin labelling MRI

  • Oyarzun Domeño, Anne
  • Cia Alonso, Izaskun
  • Echeverría Chasco, Rebeca
  • Fernández Seara, María Asunción
  • Martín Moreno, Paloma L.
  • Bastarrika, Gorka
  • Navallas Irujo, Javier
  • Villanueva Larre, Arantxa
Accurate segmentation of renal tissues is an essential step for renal perfusion estimation and postoperative assessment of the allograft. Images are usually manually labeled, which is tedious and prone to human error. We present an image analysis method for the automatic estimation of renal perfusion based on perfusion magnetic resonance imaging. Specifically, non-contrasted pseudo-continuous arterial spin labeling (PCASL) images are used for kidney transplant evaluation and perfusion estimation, as a biomarker of the status of the allograft. The proposed method uses machine/deep learning tools for the segmentation and classification of renal cortical and medullary tissues and automates the estimation of perfusion values. Data from 16 transplant patients has been used for the experiments. The automatic analysis of differentiated tissues within the kidney, such as cortex and medulla, is performed by employing the time-intensity-curves of non-contrasted T1-weighted MRI series. Specifically, using the Dice similarity coefficient as a figure of merit, results above 93%, 92% and 82% are obtained for whole kidney, cortex, and medulla, respectively. Besides, estimated cortical and medullary perfusion values are considered to be within the acceptable ranges within clinical practice., Project PC181-182 RM-RENAL, supported by the Department of University, Innovation and Digital Transformation (Government of Navarre). The author would also like to acknowledge the Department of University, Innovation and Digital Transformation (Government of Navarre) for the predoctoral grant number 0011-0537-2021-000050. Open access funding provided by Universidad Pública de Navarra.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

Multiparametric renal magnetic resonance imaging: a reproducibility study in renal allografts with stable function

  • Echeverría Chasco, Rebeca
  • Martín Moreno, Paloma L.
  • Vidorreta, Marta
  • Aramendía Vidaurreta, Verónica
  • Cano, David
  • Villanueva Larre, Arantxa
  • Bastarrika, Gorka
  • Fernández Seara, María Asunción
  • García Fernández, Nuria
Monitoring renal allograft function after transplantation is key for the early detection of allograft impairment, which in turn can contribute to preventing the loss of the allograft. Multiparametric renal MRI (mpMRI) is a promising noninvasive technique to assess and characterize renal physiopathology; however, few studies have employed mpMRI in renal allografts with stable function (maintained function over a long time period). The purposes of the current study were to evaluate the reproducibility of mpMRI in transplant patients and to characterize normal values of the measured parameters, and to estimate the labeling efficiency of Pseudo-Continuous Arterial Spin Labeling (PCASL) in the infrarenal aorta using numerical simulations considering experimental measurements of aortic blood flow profiles. The subjects were 20 transplant patients with stable kidney function, maintained over 1 year. The MRI protocol consisted of PCASL, intravoxel incoherent motion, and T1 inversion recovery. Phase contrast was used to measure aortic blood flow. Renal blood flow (RBF), diffusion coefficient (D), pseudo-diffusion coefficient (D*), flowing fraction (f), and T1 maps were calculated and mean values were measured in the cortex and medulla. The labeling efficiency of PCASL was estimated from simulation of Bloch equations. Reproducibility was assessed with the within-subject coefficient of variation, intraclass correlation coefficient, and Bland-Altman analysis. Correlations were evaluated using the Pearson correlation coefficient. The significance level was p less than 0.05. Cortical reproducibility was very good for T1, D, and RBF, moderate for f, and low for D*, while medullary reproducibility was good for T1 and D. Significant correlations in the cortex between RBF and f (r = 0.66), RBF and eGFR (r = 0.64), and D* and eGFR (r = 0.57) were found. Normal values of the measured parameters employing the mpMRI protocol in kidney transplant patients with stable function were characterized and the results showed good reproducibility of the techniques., Government of Navarra; Grant Number: PC181-182 RM-RENAL Rebeca Echeverria-Chasco received Ph.D. grant support from Siemens Healthcare Spain.