SISTEMAS AVANZADOS DE REFRIGERACION MULTIETAPA PARA APLICACIONES DE BAJA TEMPERATURA
PID2021-126926OB-C21
•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal para Impulsar la Investigación Científico-Técnica y su Transferencia
Subprograma Subprograma Estatal de Generación de Conocimiento
Convocatoria Proyectos de I+D+I (Generación de Conocimiento y Retos Investigación)
Año convocatoria 2021
Unidad de gestión Plan Estatal de Investigación Científica y Técnica y de Innovación 2021-2023
Centro beneficiario UNIVERSITAT JAUME I DE CASTELLO
Identificador persistente http://dx.doi.org/10.13039/501100011033
Publicaciones
Resultados totales (Incluyendo duplicados): 1
Encontrada(s) 1 página(s)
Encontrada(s) 1 página(s)
Effect of thermoelectric subcooling on COP and energy consumption of a propane heat pump
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
- Aranguren Garacochea, Patricia
- Sánchez, Daniel
- Haida, Michal
- Smolka, Jacek
- Cabello, Ramón
- Rodríguez García, Antonio
- Astrain Ulibarrena, David
The building sector has an important impact on the environment, being responsible for 30 % of the total greenhouse gas emissions. Knowing that the energy consumption devoted to HVAC systems accounts for 50 % of the total energy consumption of buildings, it is paramount to develop environmentally friendly technologies able to provide green space heating to the building sector. To that purpose, this manuscript presents a computational study on propane vapor compression heat pumps which include thermoelectric subcooling to boost their operation. The combination of these technologies has been proven in the past to be very beneficial for refrigeration systems and this study concludes for the first time that propane heat pumps can highly benefit from thermoelectric subcooling. The widely conducted research includes the following parameters: ambient temperatures from -20 to 15 °C, voltage supplies to the thermoelectric modules from 0.5 to 10 VDC, number of thermoelectric subcooling blocks from 1 to 8 and two water inlet temperatures, 40 and 55 °C to study their influence on heating capacity, compressor and thermoelectric power consumptions, subcooling degree, propane mass flow, compressor capacity, COP, energy consumption and SCOP of the combined heat pump. The obtained results are very conclusive, COP enhancements up to 12.29 % are achieved when a thermoelectric subcooler with 16 modules is included in a propane heat pump already provided with an internal heat exchanger for an ambient temperature of -20 °C and a water inlet temperature of 55 °C. Additionally, improvements in Seasonal COP up to 9.98 % are achieved if the above-mentioned technologies integration between a vapor compression heat pump and a thermoelectric subcooler substitutes a conventional propane heat pump with an internal heat exchanger for space heating a single-story two-family house., The authors would like to acknowledge the support of the grants PID2021-126926OB-C21 and PID2021-126926OB-C22 funded by MCIN/AEI/10.13039/501100011033 and by "ERDF A way of making Europe". Furthermore, the authors would like to acknowledge the financial support of the National Science Centre of Poland through the project No. UMO-2021/43/D/ST8/02631. Open access funding provided by Universidad Pública de Navarra.