Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 5
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Silicon-nanowire based attachment of silicon chips for mouse embryo labelling

  • Durán, S.
  • Novo, S.
  • Duch, M.
  • Gómez-Martínez, Rodrigo
  • Fernández-Regúlez, Marta
  • San Paulo, A.
  • Nogués, C.
  • Esteve i Tintó, Jaume
  • Ibáñez, E.
  • Plaza, José Antonio
© 2015 The Royal Society of Chemistry. The adhesion of small silicon chips to cells has many potential applications as direct interconnection of the cells to the external world can be accomplished. Hence, although some typical applications of silicon nanowires integrated into microsystems are focused on achieving a cell-on-a-chip strategy, we are interested in obtaining chip-on-a-cell systems. This paper reports the design, technological development and characterization of polysilicon barcodes featuring silicon nanowires as nanoscale attachment to identify and track living mouse embryos during their in vitro development. The chips are attached to the outer surface of the Zona Pellucida, the cover that surrounds oocytes and embryos, to avoid the direct contact between the chip and the embryo cell membrane. Two attachment methodologies, rolling and pushpin, which allow two entirely different levels of applied forces to attach the chips to living embryos, are evaluated. The former consists of rolling the mouse embryos over one barcode with the silicon nanowires facing upwards, while in the latter, the barcode is pushed against the embryo with a micropipette. The effect on in vitro embryo development and the retention rate related to the calculated applied forces are stated. Field emission scanning electron microscopy inspection, which allowed high-resolution imaging, also confirms the physical attachment of the nanowires with some of them piercing or wrapped by the Zona Pellucida and revealed extraordinary bent silicon nanowires., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Technological development of intracellular polysilicon-chromium-gold chips for orthogonal chemical functionalization

  • Durán, S.
  • Duch, M.
  • Patiño, T.
  • Torres, A.
  • Penon, O.
  • Gómez-Martínez, Rodrigo
  • Barrios, Lizandra
  • Esteve i Tintó, Jaume
  • Nogués, C.
  • Pérez-García, L.
  • Plaza, José Antonio
© 2014 Elsevier B.V. Increasingly, advances in microtechnologies are focused on obtaining new chips intended for applications in fields such as nanomedicine and cell biology, taking advantage of the ability of microelectronics to manufacture devices with cell dimensions and a large variety of features. Here, we report a technology for the fabrication of multi-material chips, using polysilicon and gold as device layers, to be used as bi-functional cell-internalizable devices. In our case, one of the main technological challenges is to overcome the low adherence between these two materials, especially because of their small contact-area, only 9 μm2. Thus, in order to circumvent this difficulty a chromium adherent-layer was deposited in between. After fabrication, the devices following this design can be successfully internalized inside living macrophages without affecting their viability. The advantage of having multiple material layers in one device is the potential to render multi-tasking chips, as once they are appropriately functionalized, we can provide the chip the ability of being multi-functional. Hence, and as a proof of concept, two different proteins, Wheat Germ Agglutinin (WGA) and Concanavalin (ConA), were immobilized on the chip surface through self-assembled monolayers using orthogonal chemistry. The results of this work show a well-controlled fabrication, the bi-functional capabilities and no cell-toxicity of intracellular polysilicon-chromium-gold chips. Eventually, two different dyes (Oregon Green® 488 and BODIPY® 581/591) were used to bi-functionalize each surface of the multi-material chip in order to demonstrate that functional chips can also be internalized in living cells. These devices have a promising future as intracellular functional platforms for biosensing, drug delivery and diagnosis., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Combination of PDMS microfilters and micromixers based on flexible thermoplastic films for size sorting and mixing of microparticles

  • Lee, M.
  • Lopez-Martinez, M.J.
  • Baraket, Abdoullatif
  • Zine, N.
  • Esteve i Tintó, Jaume
  • Plaza, José Antonio
  • Ahmed, N.
  • Elaissari, Abdelhamid
  • Jaffrezic-Renault, Nicole
  • Errachid, Abdelhamid
© 2015 Wiley Periodicals, Inc. We present a study for the development of flexible microfilters based on sealing microstructured poly(dimethylsiloxane) (PDMS) to different functionalized thermoplastic films [polyimide (PI), polyethylene naphthalate (PEN), and polyethylene terephthalate (PET)]. The microfilter was manufactured by soft-lithography and replica molding and then combined with plasma activation and chemical treatment using 3-(aminopropyl)triethoxysilane (APTES). To demonstrate the functionality of the PDMS microfilters, poly(lactic-co-glycolic acid) (PLGA) microparticles (MPS) were filtered through the microfluidic device based on the three thermoplastic films. Subsequently, the mixing capabilities of a passive PDMS micromixer was observed with the injection of polymeric MPS (fluorescent and nonfluorescent) as fluidic mixers are not generally effective at mixing particles. On mixing nonfluorescent MPS (∼<10-30 μm in diameter) a mixing performance of 13.3% at 5 mm was observed. Therefore, a PDMS microfiltering device was integrated with a PDMS micromixer using a simple and cost effective home-made polymeric connector for filtration at a size sorting of 11 μm. The results exhibit that the combination of the two microfluidic devices can be achieved with size sorting and mixing of MPS with an improved mixing performance of 62.5% at 3 mm., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Traceability of human sperm samples by direct tagging with polysilicon microbarcodes

  • Novo, S.
  • Mora-Espí, I.
  • Gómez-Martínez, Rodrigo
  • Barrios, Lizandra
  • Ibáñez, E.
  • Such, X.
  • Duch, M.
  • Mora, X.
  • Plaza, José Antonio
  • Nogués, C.
© 2015 Reproductive Healthcare Ltd. Published by Elsevier Ltd. All rights reserved. The increasing number of patients undergoing assisted reproductive technology (ART) treatments and of cycles performed in fertility centres has led to some traceability errors. Although the incidence of mismatching errors is extremely low, any error is unacceptable, therefore different strategies have been developed to further minimize these errors, such as manual double-witnessing or electronic witnessing systems. More recently, our group developed a direct tagging method consisting of attaching microbarcodes directly to the zona pellucida of human oocytes/embryos. Here, this method is taken a step further by using these microbarcodes to tag human semen samples, demonstrating that the barcodes are not toxic and do not interfere in the selection of motile spermatozoa nor in the cryopreservation of the sperm samples. In addition, when this tagging system was applied to an animal model (rabbit), pregnancy rate and kitten viability were not affected., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Polysilicon-chromium-gold intracellular chips for multi-functional biomedical applications

  • Patiño, T.
  • Soriano, J.
  • Amirthalingam, E.
  • Durán, S.
  • González-Campo, Arántzazu
  • Duch, M.
  • Ibáñez, E.
  • Barrios, Lizandra
  • Plaza, José Antonio
  • Pérez-García, L.
  • Nogués, C.
The development of micro- and nanosystems for their use in biomedicine is a continuously growing field. One of the major goals of such platforms is to combine multiple functions in a single entity. However, achieving the design of an efficient and safe micro- or nanoplatform has shown to be strongly influenced by its interaction with the biological systems, where particle features or cell types play a critical role. In this work, the feasibility of using multi-material pSi-Cr-Au intracellular chips (MMICCs) for multifunctional applications by characterizing their interactions with two different cell lines, one tumorigenic and one non-tumorigenic, in terms of biocompatibility, internalization and intracellular fate, has been explored. Moreover, the impact of MMICCs on the induction of an inflammatory response has been assessed by evaluating TNFα, IL1b, IL6, and IL10 human inflammatory cytokines secretion by macrophages. Results show that MMICCs are biocompatible and their internalization efficiency is strongly dependent on the cell type. Finally as a proof-of-concept, MMICCs have been dually functionalized with transferrin and pHrodo™ Red, SE to target cancer cells and detect intracellular pH, respectively. In conclusion, MMICCs can be used as multi-functional devices due to their high biocompatibility, non-inflammatory properties and the ability of developing multiple functions., Peer Reviewed