- Delgado Gutiérrez, Evelyn Yaneth
- Torres González, Marta
- Rubio Bellido, Carlos
This dataset provides detailed information on outdoor air temperatures, indoor operative temperatures, and energy consumption for a simulated building case study focused on Seville, Spain. The data includes monthly measurements of indoor (in degrees Celsius) and outdoor (in degrees Celsius) operative temperatures throughout the year, as well as associated energy consumptions for different building needs, including lighting, heating, cooling, and equipment. The consumptions are expressed in kWh/m² and are collected under the current climate scenario as well as future projections based on different Representative Concentration Pathways (RCP 2.6, RCP 4.5, and RCP 8.5) for the years 2050 and 2100. This dataset is useful for assessing the energy demand of buildings and analyzing energy vulnerability in urban contexts, particularly in relation to climate change and its impact on heating and cooling needs., Este conjunto de datos contiene información detallada sobre las temperaturas exteriores del aire, las temperaturas operativas interiores y los consumos energéticos de un edificio simulado en un estudio de caso centrado en Sevilla, España. Los datos incluyen mediciones mensuales de las temperaturas operativas interiores (en grados Celsius) y exteriores (en grados Celsius) a lo largo de todo el año, así como los consumos energéticos asociados a las diferentes necesidades de un edificio residencial, incluyendo iluminación, calefacción, refrigeración y equipamiento. Los consumos se expresan en kWh/m² y se recopilan bajo un escenario climático actual, así como proyecciones futuras bajo diferentes rutas de concentración representativas (RCP 2.6, RCP 4.5 y RCP 8.5) para los años 2050 y 2100. Este conjunto de datos es útil para la evaluación de la demanda energética de edificios y el análisis de la vulnerabilidad energética en contextos urbanos, especialmente en relación con el cambio climático y sus efectos sobre las necesidades de calefacción y refrigeración., The dataset contains the following variables organized by columns and rows, structured monthly for each of the analyzed years (current, 2050, and 2100 under different RCP scenarios):
Month: Represents the month of the year (January to December).
Outdoor Air Temperature (°C): Monthly average outdoor air temperature measured in degrees Celsius for each month. This variable corresponds to the external weather conditions in the city of Seville for each of the climate scenarios.
Indoor Operative Temperature (°C): Monthly average indoor operative temperature measured in degrees Celsius for each month. This temperature reflects the thermal comfort inside the building, considering radiation, convection, and air temperature conditions.
Lighting: Monthly energy consumption associated with the building's lighting system, expressed in kWh per square meter of living space.
Heating: Monthly energy consumption associated with the building’s heating system, expressed in kWh per square meter of living space.
Cooling: Monthly energy consumption associated with the building’s cooling (HVAC) system, expressed in kWh per square meter of living space.
Equipment: Monthly energy consumption associated with the operation of electrical equipment inside the building (appliances, electronics, etc.), expressed in kWh per square meter of living space.
Total Consumption (kWh/m²): The total sum of energy consumption (lighting, heating, cooling, and equipment) for each month, expressed in kWh per square meter of living space.
Climate Scenarios (RCP 2.6, RCP 4.5, RCP 8.5): The values for outdoor temperature, indoor operative temperature, and energy consumption are broken down according to three greenhouse gas emissions scenarios: RCP 2.6, RCP 4.5, and RCP 8.5. These scenarios reflect different future greenhouse gas concentration trajectories and their impacts on climate conditions and energy demand., El conjunto de datos contiene las siguientes variables organizadas por columnas y filas, estructurado de forma mensual para cada uno de los años analizados (actual, 2050, y 2100 bajo distintos escenarios RCP):
Mes: Representa el mes del año (enero a diciembre).
Temperatura Exterior del Aire (°C): Temperatura media exterior del aire medida en grados Celsius para cada mes. Esta variable corresponde a las condiciones meteorológicas externas de la ciudad de Sevilla en cada uno de los escenarios climáticos.
Temperatura Operativa Interior (°C): Temperatura media operativa interior medida en grados Celsius durante cada mes. Esta temperatura refleja el confort térmico en el interior del edificio, considerando las condiciones de radiación, convección y temperatura del aire.
Iluminación: Consumo energético mensual asociado a la iluminación del edificio, expresado en kWh por metro cuadrado de superficie habitable.
Calefacción: Consumo energético mensual asociado al sistema de calefacción del edificio, expresado en kWh por metro cuadrado de superficie habitable.
Refrigeración: Consumo energético mensual asociado al sistema de refrigeración (HVAC) del edificio, expresado en kWh por metro cuadrado de superficie habitable.
Equipos: Consumo energético mensual asociado al funcionamiento de los equipos eléctricos dentro del edificio (electrodomésticos, electrónica, etc.), expresado en kWh por metro cuadrado de superficie habitable.
Consumo Total (kWh/m²): Suma total de los consumos energéticos (iluminación, calefacción, refrigeración y equipos) durante cada mes, expresado en kWh por metro cuadrado de superficie habitable.
Escenarios Climáticos (RCP 2.6, RCP 4.5, RCP 8.5): Los valores de temperatura exterior, temperatura operativa interior y consumo energético se desglosan en función de tres escenarios de emisiones de gases de efecto invernadero: RCP 2.6, RCP 4.5 y RCP 8.5. Estos escenarios reflejan diferentes trayectorias futuras de concentración de gases de efecto invernadero y sus efectos sobre las condiciones climáticas y la demanda energética.