Resultados totales (Incluyendo duplicados): 6
Encontrada(s) 1 página(s)
Digital.CSIC. Repositorio Institucional del CSIC
oai:digital.csic.es:10261/214595
Dataset. 2020

THE RIFSIS WIDE-ANGLE REFLECTION EXPERIMENT THROUGH THE RIF CORDILLERA (N MOROCCO)

  • Gallart Muset, Josep
  • Diaz, J.
  • Carbonell, Ramón
In October 2011, we acquired a 330 km-long and a 430 km-long wide-angle seismic reflection profiles oriented, approximately, EW and NS. Each of the 5 sources consisted of 1Tn of chemical explosives in 2 boreholes and was recorded by 845 digital seismographs with one-component 4.5 Hz geophones (Reftek RF125 IRIS-PASSCAL Texans). The average receiver spacing was 750 m. Shots R1 through R3 where located along the NS line, and R3–R5 were along the EW line. Shot R3 is at the intersection of the two profiles. All shots were recorded by all the stations producing fan shots for 3-D control on deep structure. Up to 402 seismographs were deployed along the EW profile and 443 along the NS profile including 35 in Spain. T, The RIFSIS experiment provided the first well-resolved P-wave velocity crustal models of the Rif Cordillera and its southern continuation toward the Atlas made using controlled-source seismic data. Two 300+ km-long wide-angle reflection profiles crossed the Rif along NS and EW trends. The profiles recorded simultaneously five land explosions of 1Tn each using 850 high frequency seismometers., Ministerio de Ciencia e Innovación. Plan Nacional de Investigación científica, desarrollo e innovación tecnológica, CGL2009–09727; Ministerio de Educación y Ciencia, CGL2006–00041; Comisión Interministerial de Ciencia y Tecnología (CICYT), CGL2008–03474; United Sstates National Science Foundation (NSF), EAR-0808939, No

Proyecto: //
DOI: http://hdl.handle.net/10261/214595
Digital.CSIC. Repositorio Institucional del CSIC
oai:digital.csic.es:10261/214595
HANDLE: http://hdl.handle.net/10261/214595
Digital.CSIC. Repositorio Institucional del CSIC
oai:digital.csic.es:10261/214595
PMID: http://hdl.handle.net/10261/214595
Digital.CSIC. Repositorio Institucional del CSIC
oai:digital.csic.es:10261/214595
Ver en: http://hdl.handle.net/10261/214595
Digital.CSIC. Repositorio Institucional del CSIC
oai:digital.csic.es:10261/214595

Digital.CSIC. Repositorio Institucional del CSIC
oai:digital.csic.es:10261/219766
Dataset. 2020

THE ILIHA DEEP SEISMIC SOUNDING EXPERIMENT (IBERIAN LITHOSPHERE HETEROGENEITY AND ANISOTROPY)

  • Diaz, J.
  • Gallart Muset, Josep
  • Córdoba, Diego
  • Senos, L.
  • Matias, L.
  • Suriñach, Emma
  • Hirn, A.
  • Maguire, P.
Ten shots were fired offshore with charges between 500 and 1000 kg. Five land shot (lang quarry blasts) were fired in two points (G and P)., The ILIHA (Iberian Lithosphere Heterogeneity and Anisotropy) Project was designed to be a large-scale test for vertical and lateral heterogeneity and seismic anisotropy in the subcrustal lithosphere over the Variscan domain of the Iberian Peninsula. It consists of a star-shaped arrangement of six long-range deep seismic sounding profiles, acquired in 1989., ILIHA project, Contrat ST2P-0389-C; European Geotraverse (EGT); Stimulation programme of the Commission of the European Communities, Directorate General XII; Swiss National Research Funds, No

Proyecto: //
DOI: http://hdl.handle.net/10261/219766
Digital.CSIC. Repositorio Institucional del CSIC
oai:digital.csic.es:10261/219766
HANDLE: http://hdl.handle.net/10261/219766
Digital.CSIC. Repositorio Institucional del CSIC
oai:digital.csic.es:10261/219766
PMID: http://hdl.handle.net/10261/219766
Digital.CSIC. Repositorio Institucional del CSIC
oai:digital.csic.es:10261/219766
Ver en: http://hdl.handle.net/10261/219766
Digital.CSIC. Repositorio Institucional del CSIC
oai:digital.csic.es:10261/219766

Digital.CSIC. Repositorio Institucional del CSIC
oai:digital.csic.es:10261/222155
Dataset. 2020

LITOSPHERIC STRUCTURE OF THE NORTH IBERIAN MARGIN: MARCONI-WA REFLECTION PROFILES

  • Gallart Muset, Josep
  • Pulgar, J. A.
  • Muñoz, Josep A.
  • Diaz, J.
  • Ruiz Fernández, Mario
An onshore-offshore network of 24 Ocean-Bottom Seismometers or Hydrophones (12 OBS and 8 OBH) and 35 land stations deployed in 46 different sites. The OBS/OBH network remained fixed during all the experiment and covered on place all the profile intersections, with an average spacing of 30–40 km. The land seismic stations were deployed with an average spacing of 10–15 km extending the N-S profiles onshore, with some additional instruments following the shoreline. The seismic source consisted of a Bolt airgun array fired every 40 s, resulting in a shot spacing of 100 m. The shooting pressure was set constant at 140 bars., Ruiz Fernández, Mario; mruiz@geo3bcn.csic.es, MARCONI (MARgen COntinental Nord Iberico - North Iberian Continental Margin) is a deep seismic reflection survey carried out in the southeastern part of the Bay of Biscay in September 2003. It included the acquisition of 11 multichannel (http://dx.doi.org/10.20350/digitalCSIC/8972) and wide-angle deep seismic reflection profiles covering a total length of 2000 km., MARCONI (MARgen COntinental Nord Iberico - North Iberian Continental Margin) is a deep seismic reflection survey carried out in the southeastern part of the Bay of Biscay in September 2003. It included the acquisition of 11 multichannel (http://dx.doi.org/10.20350/digitalCSIC/8972) and wide-angle deep seismic reflection profiles covering a total length of 2000 km, Ministerio de Ciencia y Tecnología, REN2001-1734, MARCONI; CDS2006-0041, Consolider-Ingenio 2010 Programme Topo-Iberia; Ministerio de Ciencia e Innovación, CGL2008-03474-E/BTE, TopoMed; Ministerio de Economía y Competitividad, CGL2013-48601-C2-2-R, MISTERIOS, Peer reviewed

DOI: http://hdl.handle.net/10261/222155
Digital.CSIC. Repositorio Institucional del CSIC
oai:digital.csic.es:10261/222155
HANDLE: http://hdl.handle.net/10261/222155
Digital.CSIC. Repositorio Institucional del CSIC
oai:digital.csic.es:10261/222155
PMID: http://hdl.handle.net/10261/222155
Digital.CSIC. Repositorio Institucional del CSIC
oai:digital.csic.es:10261/222155
Ver en: http://hdl.handle.net/10261/222155
Digital.CSIC. Repositorio Institucional del CSIC
oai:digital.csic.es:10261/222155

UPCommons. Portal del coneixement obert de la UPC
oai:upcommons.upc.edu:2117/189334
Dataset. 2020

TOWARD THE NEW GENERATION OF SURGICAL MESHES WITH 4D RESPONSE: SOFT, DYNAMIC AND ADAPTABLE [DATASET]

  • Lanzalaco, Sonia|||0000-0002-8604-5095
  • Turón Dols, Pau
  • Weis, Christine
  • Mata, Christian
  • Planas Cuchi, Eulàlia|||0000-0002-7053-3959
  • Alemán Llansó, Carlos|||0000-0003-4462-6075
  • Armelín Diggroc, Elaine Aparecida|||0000-0002-0658-7696
These data are associated to the paper with the same title and are structured according to the figures in the paper. These data correspond to the research results of the WP3 of the European Project 4D-POLYSENSE., The present dataset reports the scientific results corresponding to a scientific study where a bidimensional (2D) polypropylene flexible mesh material has been converted into a fourth dimension (4D) dynamic system. The platform is composed by a fibres of isotactic polypropylene (iPP) mesh coated with thermosensitive poly(N-isopropylacrylamide-co-N,N'-methylene bis(acrylamide) (PNIPAAm-co-MBA) hydrogel, and undergoes variations in its geometry by reversible folding/unfolding behaviour. Folding and unfolding motion in aqueous solution of bilayer and monolayer systems composed by two or one layer of hydrogel, respectively, are reported in the present dataset. Furthermore, an infrared thermographic camera and an optical microscope were used to evaluate the macroscopic and microscopic structure stimulus response in air. Additionally, PP-g-PNIPAAm meshes showed an increase in the mechanical properties (bursting strength) with respect to the uncoated mesh.

DOI: http://hdl.handle.net/2117/189334, https://dx.doi.org/10.5821/data-2117-189334-1
UPCommons. Portal del coneixement obert de la UPC
oai:upcommons.upc.edu:2117/189334
HANDLE: http://hdl.handle.net/2117/189334, https://dx.doi.org/10.5821/data-2117-189334-1
UPCommons. Portal del coneixement obert de la UPC
oai:upcommons.upc.edu:2117/189334
PMID: http://hdl.handle.net/2117/189334, https://dx.doi.org/10.5821/data-2117-189334-1
UPCommons. Portal del coneixement obert de la UPC
oai:upcommons.upc.edu:2117/189334
Ver en: http://hdl.handle.net/2117/189334, https://dx.doi.org/10.5821/data-2117-189334-1
UPCommons. Portal del coneixement obert de la UPC
oai:upcommons.upc.edu:2117/189334

UPCommons. Portal del coneixement obert de la UPC
oai:upcommons.upc.edu:2117/187590
Dataset. 2020

POLYPROPYLENE MESH FOR HERNIA REPAIR WITH CONTROLLABLE CELL ADHESION/DE-ADHESION PROPERTIES [DATASET]

  • Lanzalaco, Sonia|||0000-0002-8604-5095
  • Valle Mendoza, Luis Javier del|||0000-0001-9916-1741
  • Turón Dols, Pau
  • Weis, Christine
  • Estrany Coda, Francesc|||0000-0002-2696-1489
  • Alemán Llansó, Carlos|||0000-0003-4462-6075
  • Armelín Diggroc, Elaine Aparecida|||0000-0002-0658-7696
These data are associated to the paper with the same title and are structured according to the figures in the paper. These data correspond to the research results of the WP2 of the European Project 4D-POLYSENSE., The present dataset collects and reports the scientific results corresponding to a scientific study of a commercial and fully flexible versatile bilayer system, composed by a polypropylene (PP) mesh and a covalently bonded poly(N-isopropylacrylamide) (PNIPAAm) hydrogel. In this study the mechanism responsible for cell-adhesion and de-adhesion, when the PNIPAAm-co-MBA monolayer film (adherent on one hand to the PP substrate and anti-adherent on the other hand to cell proliferation) is being employed, has been elucidated. The grafting of the hydrogel was studied and the the graft yield as well as the spectroscopic characterization (FTIR and XPS) of samples treated at different concentration of the crosslinker and different grafting time are ported in the present dataset. The scientific results of cell adhesion and biocompatibility assay are also included, being the in vitro results with fibroblast (COS-1) and epithelial (MCF-7) cells obtained with a mesh modified with a porous iPP-g-PNIPAAm bilayer system, prepared via PNIPAAm grafting for 2 h at the lowest N,NI-methylene bis(acrylamide) (MBA) concentration (1 mM).

DOI: http://hdl.handle.net/2117/187590, https://dx.doi.org/10.5821/data-2117-187590-1
UPCommons. Portal del coneixement obert de la UPC
oai:upcommons.upc.edu:2117/187590
HANDLE: http://hdl.handle.net/2117/187590, https://dx.doi.org/10.5821/data-2117-187590-1
UPCommons. Portal del coneixement obert de la UPC
oai:upcommons.upc.edu:2117/187590
PMID: http://hdl.handle.net/2117/187590, https://dx.doi.org/10.5821/data-2117-187590-1
UPCommons. Portal del coneixement obert de la UPC
oai:upcommons.upc.edu:2117/187590
Ver en: http://hdl.handle.net/2117/187590, https://dx.doi.org/10.5821/data-2117-187590-1
UPCommons. Portal del coneixement obert de la UPC
oai:upcommons.upc.edu:2117/187590

UPCommons. Portal del coneixement obert de la UPC
oai:upcommons.upc.edu:2117/187515
Dataset. 2020

THE MECHANISM OF ADHESION AND GRAFT POLYMERIZATION OF A PNIPAAM THERMORESPONSIVE HYDROGEL TO POLYPROPYLENE MESHES [DATASET]

  • Lanzalaco, Sonia|||0000-0002-8604-5095
  • Turón Dols, Pau
  • Weis, Christina
  • Alemán Llansó, Carlos|||0000-0003-4462-6075
  • Armelín Diggroc, Elaine Aparecida|||0000-0002-0658-7696
These data are associated to the paper with the same title and are structured according to the figures in the paper. These data correspond to the research results of the WP1 of the European Project 4D-POLYSENSE., In the scientific publication corresponding to the present dataset, a commercial and fully flexible monofilament polypropylene mesh has been used for the deposition of a thermosensitive hydrogel, generated by graft copolymerization of N-isopropylacrylamide (NIPAAm) and N,NI-methylene bis(acrylamide) (MBA) monomers. The study represents an initial step for the future development of a new generation of surgical meshes, able to interact with the complex three-dimensional structure of biological tissues, as smart materials working as self-evolving motion sensors. The meshes were previously functionalized by O2-plasma method and subsequently grafted with the thermoresponive hydrogel and the data related to micro- and standard spectroscopy techniques empoyed for the characterization, such as Raman spectroscopy, FTIR spectroscopy and XPS, are reported in the present dataset. Additionally, the data of graft yield and thermoresponsive properties of PNIPAAm (VPTT behaviour) are included in the dataset

DOI: http://hdl.handle.net/2117/187515, https://dx.doi.org/10.5821/data-2117-187515-1
UPCommons. Portal del coneixement obert de la UPC
oai:upcommons.upc.edu:2117/187515
HANDLE: http://hdl.handle.net/2117/187515, https://dx.doi.org/10.5821/data-2117-187515-1
UPCommons. Portal del coneixement obert de la UPC
oai:upcommons.upc.edu:2117/187515
PMID: http://hdl.handle.net/2117/187515, https://dx.doi.org/10.5821/data-2117-187515-1
UPCommons. Portal del coneixement obert de la UPC
oai:upcommons.upc.edu:2117/187515
Ver en: http://hdl.handle.net/2117/187515, https://dx.doi.org/10.5821/data-2117-187515-1
UPCommons. Portal del coneixement obert de la UPC
oai:upcommons.upc.edu:2117/187515

Buscador avanzado