Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 9
Encontrada(s) 1 página(s)

Docta Complutense
Publication Artículo científico (JournalArticle)

Proton irradiation effects on silicon heterojunction solar cells with MoOx selective contacts

  • Duarte Cano, Sebastián
  • Pérez Zenteno, Francisco José
  • Caudevilla Gutiérrez, Daniel
  • Olea Ariza, Javier
  • San Andrés Serrano, Enrique
  • Prado Millán, Álvaro Del
  • Benítez Fernández, Rafael
  • García Hemme, Eric
  • Rezaei, Mohammadreza
  • Clemente Barreira, Juan Antonio
  • Algaidy, S.
  • Torres, I.
  • Barrio, R.
  • Ros, E.
  • Puigdollers, J.
  • Ortega, P.
  • Voz, C.
  • García Hernansanz, Rodrigo
In this study, we investigate the effects of proton irradiation on silicon-based heterojunction and molybdenum oxide (MoOx) selective contact solar cells. The main idea is to study their potential application in small satellites for measurement and monitoring. The irradiation dose simulates the aggressive environment found in Low Earth Orbit (LEO), where many satellites currently use Group III-VI (GaInP/GaAs/Ge) solar cells due to their superior efficiency, albeit at a higher cost. The experimental approach includes fabrication, irradiation, and characterization methods. Our results show a decrease in fill factor (F.F.) and overall efficiency after irradiation, mainly caused by a decrease in shunt resistance and an increase in series resistance. In addition, open-circuit voltage (Voc) and short-circuit current (Isc) may be affected by displacement damage defects caused by the irradiation process within the active region or by the formation of new point defects.
e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publication Artículo científico (JournalArticle)

Evaluating Reduced Resolution Redundancy for Radiation Hardening in FPGA Designs

  • García Astudillo, Luis Ángel
  • Lindoso Muñoz, Almudena
  • Entrena Arrontes, Luis Alfonso
  • Martín González, Honorio
  • García Valderas, Mario
  • Martín-Holgado, Pedro
  • Morilla, Yolanda
Radiation hardening by design (RHBD) is traditionally performed using triple modular redundancy (TMR), a very effective technique that introduces high overheads in terms of resources and power. The reduced resolution redundancy (RRR) technique presented in this work is a new approximate error mitigation technique that uses redundant circuits with lower resolution to perform computations. In this work, we evaluate this technique under radiation using two different benchmarks implemented in field-programmable gate array (FPGA), namely, a fast Fourier transform (FFT) and an image processing algorithm for a near-infrared (NIR) detector. Experimental results from proton and neutron irradiation, and fault injection campaigns, show that the RRR hardening technique can effectively mitigate errors with reduced overheads., This work was supported in part by the Spanish Agencia Estatal de Investigacion (AEI) under Project PID2019-106455GB-C21 and Project AEI/10.13039/501100011033 and in part by the European Union's Horizon 2020 Research and Innovation Program through the Framework of the European Union (EU) Project RADiation facility Network for the EXploration of Effects for indusTry and research (RADNEXT) under Grant 101008126.
e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publication Artículo científico (JournalArticle)

Hybrid Hardening Approach for a Fault-Tolerant RISC-V System-On-Chip

  • Santos, Douglas A.
  • Avilés Delgado, Pablo Miguel
  • Mattos, André M. P.
  • García Valderas, Mario
  • Entrena Arrontes, Luis
  • Lindoso Muñoz, Almudena
The New Space era has driven a wide array of applications in novel space missions with an increasing demand for processors with high computational capabilities while simultaneously maintaining low power consumption, flexibility, and reliability. Soft-core processors based on commercial off-the-shelf (COTS) technologies have emerged as a viable alternative that can meet these requirements but need to be hardened to operate in harsh environments. In this work, we propose and apply fault tolerance strategies based on software recovery using checkpoint and rollback operations to extend the capabilities of a hardened soft-core RISC-V-based system-on-chip. The proposed strategy relies on the fault awareness provided by the system-on-chip hardening to trigger the software recovery without the addition of dedicated structures or processor cores. Notably, we investigate the effectiveness of this multilayer hardening strategy, which combines software recoverability and hardware redundancy. For that, a neutron irradiation campaign was performed. The results show the effectiveness of the proposed approach, achieving 45.09% of effective software recovery operations with low overhead for performance and resource utilization., European Union’s Horizon 2020 Research and Innovation Program (Grant Number: 101008126) Region d’Occitanie and the École Doctorale I2S through the University of Montpellier (Grant Number: 20007368/ALDOCT- 000932) 10.13039/501100004837-Ministerio de Ciencia e Innovación (MCIN)/Agencia Estatal de Investigación (Grant Number: (AEI)/10.13039/501100011033) “European Regional Development Fund (ERDF) A way of making Europe” (Grant Number: PID2022-138696OB-C21)
e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publication Artículo científico (JournalArticle)

Reliability assessment of AMD MicroBlaze-V TMR architecture using fault injection and proton irradiation

  • Cano Páez, Jorge
  • Entrena Arrontes, Luis Alfonso
  • Lindoso Muñoz, Almudena
This work analyses the robustness of the recent AMD RISC-V processor: MicroBlaze-V. We study the TMR fault tolerant version of the MicroBlaze-V architecture, implemented in an SRAM-based FPGA. The architecture has been evaluated with fault injection and irradiation campaigns using 15 and 230 MeV proton beams. Experimental results show that AMD TMR MicroBlaze-V architecture offers a fast and flexible design process with good error mitigation of faults in the configuration memory. The results obtained show a good correlation between fault injection and proton irradiation campaigns, which may be used for error-rate estimations and precise error mitigation strategies. Overall, AMD TMR MicroBlaze-V has an error detection rate of around 99.84%. Approximately 1% of failures are not warned beforehand, although experimental data show that these errors are related to the memory, which is triplicated. It is calculated that, under the evaluated conditions, the mean time for a system failure is twice the mean time for a non-fatal error to happen. The cross-section is estimated to be 47 and 65 times better for failures with a previous warning compared to failures without warning in experiments with protons of 15 MeV and 230 MeV respectively., This work has been supported in part by the Community of Madrid, under grant PIPF-2024/TEC-34925, by project PID2022–138696OB- C21 funded by MCIN/AEI/10.13039/501,100,011,033 and by “ERDF A way of making Europe”, and in part by the European Union’s Horizon 2020 Research and Innovation Program through the Framework of the European Union (EU) Project RADiation facility Network for the Exploration of Effects for indusTry and research (RADNEXT) under Grant 101008126.
e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publication Artículo científico (JournalArticle)

Evaluation of a Robust System for Hyperspectral Data Compression Under Neutron and Proton Effects

  • Entrena Arrontes, Luis Alfonso
  • Sánchez Clemente, Antonio José
  • García Valderas, Mario
  • Barrios, Yubal
  • Sarmiento, Roberto
  • Lindoso Muñoz, Almudena
The use of hyperspectral sensors in space missions is steadily increasing. These sensors generate large volumes of data in the form of hyperspectral cubes (images captured in hundreds of different wavelengths) which require the adoption of data compression solutions onboard. In this work we evaluate error mitigation for CCSDS-123 hyperspectral data loss less compression IP. Realizing that a data compressor has to be used with some data interfaces and possibly a processor, the evaluation is performed for entire systems built around the SHyLoC CCSDS-123 IP core. To this purpose, we designed hardened systems that include redundant IP cores, input and output data stream interfaces, and processors. The hardened systems were implemented in a commercial SoC device and tested with atmospheric neutrons and protons. Experimental results are presented and discussed for two architectures using dual and triple IP core redundancy, respectively., The authors would like to acknowledge ISIS (UK) for providing the neutron beam time and to Centro Nacional de Aceleradores (Spain) for the access to the proton beam. We would like to thank Chris Frost, Carlo Cazzaniga and Maria Kastriotou for their help with the neutron experiment, and Yolanda Morilla, Amor Romero and Pedro Martín-Holgado for their help with the proton experiment.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Mixed-Field Radiation Monitoring and Beam Characterization Through Silicon Diode Detectors

  • Bilko, Kacper
  • García Alía, Rubén
  • Sacristán Barbero, Mario
  • Girard, Sylvain
  • Aguiar, Ygor Q.
  • Cecchetto, Matteo
  • Belanger-Champagne, Camille
  • Danzeca, Salvatore
  • Hajdas, Wojtek
  • Hands, Alex
  • Martín Holgado, Pedro
  • Morilla, Yolanda
  • Romero-Maestre, Amor
  • Prelipcean, Daniel
  • Ravotti, Federico
  • Sebban, Marc
We present a calibration of a commercial silicon diode with proton and alpha beams and gamma rays. The diode together with a fast acquisition chain can be exploited for both direct and indirect (through the secondary radiation field) beam characterization. Within this work, we demonstrate the detector capabilities of resolving single-energy-deposition events and independently measuring dose rate and beam flux. Profiting from the mixed radiation field in CERN's high-energy accelerator mixed field facility (CHARM) we show how the silicon detector can be exploited to characterize the mixed radiation field present in it, which in turn is used for validating the radiation tolerance of components and systems to be installed in the European Organization for Nuclear Research (CERN) accelerator complex., European Union’s Horizon 2020 Research and Innovation Program (Grant Number: 101008126). European Union’s 2020 Research and Innovation Program, corresponding to the RADNEXT project, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Ultra-Large Silicon Diode for Characterizing Low-Intensity Radiation Environments

  • Bilko, Kacper
  • García Alía, Rubén
  • Girard, Sylvain
  • Sacristán Barbero, Mario
  • Cecchetto, Matteo
  • Belanger-Champagne, Camille
  • Brucoli, Matteo
  • Danzeca, Salvatore
  • Hands, Alex
  • Martín Holgado, Pedro
  • Morilla, Yolanda
  • Romero-Maestre, Amor
  • Sebban, Marc
  • Widorski, Markus
We present applications of a large commercial silicon diode (50 cm^2× 500μ m ) for monitoring low-intensity radiation fields, together with benchmarks via Monte Carlo simulations. After energy calibration with monoenergetic proton and alpha beams in the 2-8-MeV range, we show that the detector is capable of measuring atmospheric radiation at the ground level, not only in terms of a total number of events but also through their energy deposition distribution. Focusing on the atmospheric-like neutron spectrum, we prove that the diode detection cross Section is more than five orders of magnitude larger with respect to static random access memory (SRAM)-based solutions and highlight the potential use cases in the accelerator's radiation environment., European Union’s Horizon 2020 Research and Innovation Program (Grant Number: 101008126), Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Optical Fiber-Based Sensors for Real-Time Monitoring for Low-Energy Proton Beams

  • Fricano, Fiammetta
  • Weninger, Luca
  • Morana, Adriana
  • Romero-Maestre, Amor
  • Martín Holgado, Pedro
  • Martín Hernández, José de
  • Morilla, Yolanda
  • Lambert, Damien
  • Paillet, Philippe
  • El Hamzaoui, Hicham
  • Capoen, Bruno
  • Bouazaoui, Mohamed
  • Marin, Emmanuel
  • Ouerdane, Youcef
  • Boukenter, Aziz
  • Girard, Sylvain
This work presents the first results from our investigation regarding the potential use of radioluminescent Ce3+-doped silica-based optical fibers as sensors capable of monitoring the flux of low-energy (≤ 15 MeV) protons. This technology is shown as a promising candidate for dosimetry at the Centro Nacional de Aceleradores (CNA), offering improved precision and real-time radiation monitoring during radiation test campaigns on microelectronics or photonics components and devices. Two proton beam lines have been used to characterize the fiber dosimeters in two different CNA facilities, using a 18/9 Cyclotron and a Tandem 3 MV accelerators. The calibration of the sensor for monitoring the proton flux at 15 MeV is currently reliable within a 24% margin, due to the presence of significant beam fluctuations that prevent a unique correlation between radioluminescence levels and the associated flux values. However, this result can be improved through additional tests aimed at refining the calibration process. When using 3 MeV protons, the signal exhibits an enhanced radioluminescence, confirming the high sensitivity of optical fibers to low-energy protons. Physically relevant insights are obtained, as the compact geometry of the optical fiber makes it sufficiently embedded to detect the 3 MeV proton Bragg peak within its sensitive core region. Nevertheless, further investigations are needed to fully understand the radioluminescence mechanism, especially under the high-dose rate conditions involved., This study was supported by European Union's Horizon 2020 research and innovation program (101008126); RADNEXT project., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Performance of a CeBr3 scintillator coupled to a photomultiplier tube with an active voltage divider under high bremsstrahlung fluences

  • García Rivas, I.
  • Fernández Prieto, A.
  • Vázquez Regueiro, P.
  • García Fernández, D.
  • Kögler, T.
  • Römer, K.
  • Hueso-González, F.
Proton therapy lacks a standard method to verify the proton range during the treatments in the clinical routine. In this context, the monitoring of prompt γ-rays in a coaxial geometry using a compact detector based on a CeBr3 scintillator coupled to a commercial photomultiplier tube (PMT) could lead to the identification of proton range deviations. Such detection system could be easily integrated in every treatment room. Although measuring in this geometry profits from an advantageous solid angle, the detector is also exposed to an extreme γ-ray rate, of up to 10 Mcps. In this work, we present the first experimental performance evaluation for the proposed detector by irradiating it at very high bremsstrahlung rates at the γELBE facility. Using a customized active voltage divider to supply voltage to the PMT, the detection system was able to sustain a photon rate higher than 12 Mcps without dead time while keeping gain drifts below 15 % in the best configuration, and to achieve a sub-nanosecond time resolution. © 2025 The Author(s), This work has been supported by Xunta de Galicia, Spain, under the Industrial Doctorates Program 2022 (Galician Innovation Agency) and under grant number ED431C/3, by Ministerio de Ciencia e Innovación, Spain, under project PID2022-140591NB-I00 and by Generalitat Valenciana, Spain, (Conselleria de Educación, Investigación, Cultura y Deporte) under grant number CDEIGENT/2019/011. This work has also received funds from the Particle Therapy Cooperative Group (PTCOG) under project funding 2024 and from the European Union’s 2020 research and innovation program under grant 101008126, corresponding to RADNEXT project. IGFAE is supported by the María de Maeztu grant CEX2023-001318-M and IFIC by the Severo Ochoa Center of Excellence grant CEX2023-001292-S, both funded by MCIU/AEI., Peer reviewed