Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 2
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Characterization of new silicon carbide neutron detectors with thermal and fast neutrons

  • Pérez, Martín
  • Zamorano, Felipe
  • Fleta, Celeste
  • Fernández, Begoña
  • Guerrero, C.
  • Godignon, Philippe
  • Pellegrini, Giulio
  • Pérez-Maroto, Pablo
  • Guardiola Salmerón, Consuelo
The aim of this work is to present a characterization of a new silicon carbide (SiC) neutron detector fabricated at the Institute of Microelectronics of Barcelona (IMB-CNM-CSIC). The device is based on a 50μm thick p-n diode built in a 4H-SiC wafer. Performance studies were carried out under different neutron energy spectra, including thermal and quasi-monoenergetic fast neutrons at the CNA HiSPANoS facility. We implemented a method for the fabrication of enriched LiF conversion layers to use for the detection of thermal neutrons. The detector was proven to be capable of being used for thermal neutron detection with conversion layers of 10B and LiF. A detection efficiency of 6 ± 1% was achieved with a 25μm thick LiF conversion layer. It was also confirmed that the device can be employed for the detection of recoil nuclei and protons produced by fast neutrons. The spectra obtained experimentally were compared with PHITS simulations. This work represents the first step towards the design and fabrication of new SiC neutron detectors in the IMB-CNM-CSIC clean room with potential applications in various scientific and technological fields., This project has received funding from the European Union Horizon2022 research and innovation programme under the Marie Sklodowska-Curie grant agreement N◦101106191. This work has also been funded by the Consejo de Seguridad Nuclear (CSN) under the project Sub-venciones 2022 SUB-08. In addition, it has also received funding bySpanish Ministry of Science, Innovation and Universities grant num-ber CEX2023-001397-M, and by the European Union’s ERDF program(MCIN/AEI/10.13039/501100011033/) ‘‘A way of making Europe’’under grant references RTC-2017-6369-3 (FEDER/EU), and PID2021-124660OB-C22. The authors would like to thank Javier Bravo, IvánLopez Paz, Xavier Ayesta, and Esteve Cot for their technical assistance,and also the staff of IMB-CNM-CSIC and CNA., With funding from the Spanish goverment through th "Severo Ochoa Centre of Excellence" accreditation (CEX2023-001397-M), Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Out-of-field thermal neutron characterization with thin 3D-silicon detectors in Varian TrueBeam and Elekta Synergy LINACs, Replication data for Out-of-field thermal neutron characterization with thin 3D-silicon detectors in Varian TrueBeam and Elekta Synergy LINACs

  • Zamorano, Felipe
  • Pérez, Martín
  • Fleta, Celeste
  • Muñoz-Montplet, Carles
  • Jurado-Bruggeman, Diego
  • Bianchini, Sebastián
  • Blostein, Juan Jerónimo
  • Lipovetzky, José
  • Guardiola Salmerón, Consuelo
Neutron contamination near medical linear accelerators (LINACs) has raised increasing concerns regarding secondary risks for patients undergoing photon-based radiotherapy (RT) at energies above 6 MV.Objective.In this work the aim was to evaluate in real-time the secondary neutron fluence to compare the neutron production between two widely used LINACs (Varian TrueBeam and Elekta Synergy) operating at 15 MV. Thermal neutron contributions were measured in the treatment rooms using a 10 × 10 cm2field size, flattening filter, and doses ranging from 100 to 1000 monitor units (MU) and dose rates from 100 to 600 MU min-1.Approach.An ultra-thin (20μm) silicon detector with 3D electrodes, paired with a (45 ± 5)μm thick10B-enriched conversion layer was used to quantify the thermal neutron field in both LINAC treatment rooms. The thin active volume of 20μm thick offers a high gamma rejection factor (>10-8), which is crucial for effectively isolating neutron signals in high-gamma RT environments. A customized readout electronics was developed for online measurements. The detector responses were compared with those obtained with PHITS Monte Carlo simulations using an extended model of the TrueBeam LINAC head operating at 15 MV. This model, which includes detailed head shielding for the first time, was validated with percentage depth dose data.Main results.The findings demonstrated the ability of the sensors to characterize the thermal neutron field, achieving a detection efficiency of (1.53 ± 0.02)% at a 660 keV energy threshold and operating without interference from the high intense photon background. The results show that the secondary neutron field produced by the Varian TrueBeam was approximately four times higher than that of the Elekta Synergy.Significance.These findings highlight significant differences in neutron contamination between LINAC models, thus with implications for patient safety and shielding design in RT facilities., This project has been funded by the Spanish Nuclear Safety Council (CSN) under the Subvenciones 2022 SUB-08 programme and the CSIC PIE Incorporación CT (2024ICT157). Additional funding was provided by the European Union’s Horizon 2022 research and innovation programme under the Marie Skłodowska-Curie Grant Agreement N. 101106191. The project also received support from the Spanish government through the ‘María de Maeztu Unit of Excellence’ accreditation (CEX2023-001397-M/AEI/ 10.13039/501100011033). This work was carried out within the framework of the Doctoral Program in Physics at the Autonomous University of Barcelona, Peer reviewed