Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 13
Encontrada(s) 1 página(s)

Biblos-e Archivo. Repositorio Institucional de la UAM
Publication Artículo científico (JournalArticle)

Polarization-sensitive optical projection tomography for muscle fiber imaging

  • Fang, Mengjie
  • Dong, Di
  • Zeng, Chaoting
  • Liang, Xiao
  • Yang, Xin
  • Arranz, Alicia
  • Ripoll, Jorge
  • Hui, Hui
  • Tian, Jie
Optical projection tomography (OPT) is a tool used for three-dimensional imaging of millimeter-scale biological samples, with the advantage of exhibiting isotropic resolution typically in the micron range. OPT can be divided into two types: transmission OPT (tOPT) and emission OPT (eOPT). Compared with eOPT, tOPT discriminates different tissues based on their absorption coefficient, either intrinsic or after specific staining. However, it fails to distinguish muscle fibers whose absorption coefficients are similar to surrounding tissues. To circumvent this problem, in this article we demonstrate a polarization sensitive OPT system which improves the detection and 3D imaging of muscle fibers by using polarized light. We also developed image acquisition and processing protocols that, together with the system, enable the clear visualization of muscles. Experimental results show that the muscle fibers of diaphragm and stomach, difficult to be distinguished in regular tOPT, were clearly displayed in our system, proving its potential use. Moreover, polarization sensitive OPT was fused with tOPT to investigate the stomach tissue comprehensively. Future applications of polarization sensitive OPT could be imaging other fiberlike structures such as myocardium or other tissues presenting high optical anisotropy, This work is supported by the National Basic Research Program of China (973 Program) under Grant 2011CB707700, the National Natural Science Foundation of China under Grant No. 81227901, 61231004, 81501616, 81301346, 81527805 the Chinese Academy of Sciences Fellowship for Young Foreign Scientists under Grant No. 2010Y2GA03, 2013Y1GA0004, the Chinese Academy of Sciences Visiting Professorship for Senior International Scientists under Grant No. 2012T1G0036, 2013T1G0013,the Instrument Developing Project of the Chinese Academy of Sciences under Grant No. YZ201502, YZ201457 and the Strategic Priority Research Program (B) of Chinese Academy of Sciences (XDB02060010). A. Arranz acknowledges support from the Marie Curie Intra-European Fellowship program IEF-2010-275137. J.R. acknowledges support from EC FP7 IMI project PREDICT-TB, the EC FP7 CIG grant HIGH-THROUGHPUT TOMO, and the Spanish MINECO project grant FIS2013-41802-R MESO-IMAGING
e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publication Artículo científico (JournalArticle)

Unsupervised CT lung image segmentation of a mycobacterium tuberculosis infection model

  • Macías Gordaliza, Pedro
  • Muñoz Barrutia, María Arrate
  • Abella García, Mónica
  • Desco Menéndez, Manuel
  • Sharpe, Sally
  • Vaquero López, Juan José
Tuberculosis (TB) is an infectious disease caused by Mycobacterium tuberculosis that produces pulmonary damage. Radiological imaging is the preferred technique for the assessment of TB longitudinal course. Computer-assisted identification of biomarkers eases the work of the radiologist by providing a quantitative assessment of disease. Lung segmentation is the step before biomarker extraction. In this study, we present an automatic procedure that enables robust segmentation of damaged lungs that have lesions attached to the parenchyma and are affected by respiratory movement artifacts in a Mycobacterium Tuberculosis infection model. Its main steps are the extraction of the healthy lung tissue and the airway tree followed by elimination of the fuzzy boundaries. Its performance was compared with respect to a segmentation obtained using: (1) a semi-automatic tool and (2) an approach based on fuzzy connectedness. A consensus segmentation resulting from the majority voting of three experts' annotations was considered our ground truth. The proposed approach improves the overlap indicators (Dice similarity coefficient, 94% ± 4%) and the surface similarity coefficients (Hausdorff distance, 8.64 mm ± 7.36 mm) in the majority of the most difficult-to-segment slices. Results indicate that the refined lung segmentations generated could facilitate the extraction of meaningful quantitative data on disease burden., The research leading to these results received funding from the Innovative Medicines Initiative (www.imi.europa.eu) Joint Undertaking under grant agreement no. 115337, whose resources comprise funding from the European Union’s Seventh Framework Programme (FP7/2007–2013) and EFPIA companies’ in kind contribution. This work was partially funded by projects TEC2013-48552-C2-1-R, RTC-2015-3772-1, TEC2015-73064-EXP and TEC2016-78052-R from the Spanish Ministerio de Economía, Industria y Competitividad, TOPUS S2013/MIT-3024 project from the regional government of Madrid and by the Department of Health, UK.
e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publication Artículo científico (JournalArticle)

Investigation of different sparsity transforms for the PICCS algorithm in small-animal respiratory gated CT

  • Pérez-Juste Abascal, Juan Felipe
  • Abella García, Mónica
  • Sisniega Crespo, Alejandro
  • Vaquero López, Juan José
  • Desco Menéndez, Manuel
Respiratory gating helps to overcome the problem of breathing motion in cardiothoracic small-animal imaging by acquiring multiple images for each projection angle and then assigning projections to different phases. When this approach is used with a dose similar to that of a static acquisition, a low number of noisy projections are available for the reconstruction of each respiratory phase, thus leading to streak artifacts in the reconstructed images. This problem can be alleviated using a prior image constrained compressed sensing (PICCS) algorithm, which enables accurate reconstruction of highly undersampled data when a prior image is available. We compared variants of the PICCS algorithm with different transforms in the prior penalty function: gradient, unitary, and wavelet transform. In all cases the problem was solved using the Split Bregman approach, which is efficient for convex constrained optimization. The algorithms were evaluated using simulations generated from data previously acquired on a micro-CT scanner following a high-dose protocol (four times the dose of a standard static protocol). The resulting data were used to simulate scenarios with different dose levels and numbers of projections. All compressed sensing methods performed very similarly in terms of noise, spatiotemporal resolution, and streak reduction, and filtered back-projection was greatly improved. Nevertheless, the wavelet domain was found to be less prone to patchy cartoon-like artifacts than the commonly used gradient domain., This work was partially funded by the RICRETIC network (RD12/0042/0057) from the Ministerio de Economía y Competitividad (www.mineco.gob.es/) and projects TEC2010-21619-C04-01 and PI11/00616 from Ministerio de Ciencia e Innovación (www.micinn.es/). The research leading to these results was supported by funding from the Innovative Medicines Initiative (www.imi.europa.eu) Joint Undertaking under grant agreement n°115337, the resources of which comprise financial contributions.
e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publication Artículo científico (JournalArticle)

Improving PET Quantification of Small Animal [Ga-68]DOTA-Labeled PET/CT Studies by Using a CT-Based Positron Range Correction

  • Cal González, Jacobo
  • Vaquero López, Juan José
  • Herraiz, Joaquín L.
  • Pérez Liva, Mailyn
  • Soto Montenegro, Mª Luisa
  • Peña Zalbidea, Santiago
  • Desco Menéndez, Manuel
  • Udías Moinelo, José Manuel
Image quality of positron emission tomography (PET) tracers that emits high-energy positrons, such as Ga-68, Rb-82, or I-124, is significantly affected by positron range (PR) effects. PR effects are especially important in small animal PET studies, since they can limit spatial resolution and quantitative accuracy of the images. Since generators accessibility has made Ga-68 tracers wide available, the aim of this study is to show how the quantitative results of [Ga-68]DOTA-labeled PET/X-ray computed tomography (CT) imaging of neuroendocrine tumors in mice can be improved using positron range correction (PRC)., This work was partially funded by the projects RTC-2015-3772-1, TEC2014-56600-R, and TEC2016-78052-R from the Spanish Ministry of Science and Innovation, Spanish Government, Spanish Ministry of Economy and Competitiveness grants (FIS PI11/00616, FIS PI14/00860, CP08/00017, and CPII14/00005) co-financed by European Regional Development Fund (ERDF), Alicia Koplowitz Foundation and TOPUS S2013/MIT-3024 project from the regional government of Madrid. The research leading to these results has received funding from the Innovative Medicines Initiative (www.imi.europa.eu) Joint Undertaking under grant agreement n°115337, resources of which are composed of financial contribution from the European Union’s Seventh Framework Programme (FP7/2007-2013) and EFPIA companies’ in kind contribution. Part of the calculations were performed in the “Clúster de Cálculo de Alta Capacidad para Técnicas Físicas” funded by UCM and by UE under the FEDER programme.
e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publication Artículo científico (JournalArticle)

Vertically scanned laser sheet microscopy

  • Dong, Di
  • Arranz, Alicia
  • Zhu, Shouping
  • Yang, Yujie
  • Wang, Jun
  • Shen, Chen
  • Tian, Jie
  • Ripoll Lorenzo, Jorge
Laser sheet microscopy is a widely used imaging technique for imaging the three-dimensional distribution of a fluorescence signal in fixed tissue or small organisms. In laser sheet microscopy, the stripe artifacts caused by high absorption or high scattering structures are very common, greatly affecting image quality. To solve this problem, we report here a two-step procedure which consists of continuously acquiring laser sheet images while vertically displacing the sample, and then using the variational stationary noise remover (VSNR) method to further reduce the remaining stripes. Images from a cleared murine colon acquired with a vertical scan are compared with common stitching procedures demonstrating that vertically scanned light sheet microscopy greatly improves the performance of current light sheet microscopy approaches without the need for complex changes to the imaging setup and allows imaging of elongated samples, extending the field of view in the vertical direction., This work was supported in part by the Bill and Melinda Gates Foundation, the National Basic Research Program of China (973 Program) under Grant No. 2011CB707700, the National Natural Science Foundation of China under Grant No. 81227901, 81027002, 61231004, and 81101095, the Fellowship for Young International Scientists of the Chinese Academy of Sciences under Grant No. 2010Y2GA03, and the Instrument Developing Project of the Chinese Academy of Sciences under Grant No. YZ201164. A. Arranz acknowledges support from the Marie Curie Intra-European Fellowship program IEF-2010-275137. J.R. acknowledges support from EC FP7 IMI project PREDICT-TB, the EC FP7 CIG grant HIGHTHROUGHPUT TOMO, and the Spanish MINECO project grant FIS2013-41802-R MESO-IMAGING.
e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publication Artículo científico (JournalArticle)

Computed tomography-based biomarker for longitudinal assessment of disease Burden in pulmonary tuberculosis

  • Macías Gordaliza, Pedro
  • Muñoz Barrutia, María Arrate
  • Via, L.E.
  • Sharpe, Sally
  • Desco Menéndez, Manuel
  • Vaquero López, Juan José
Purpose: Computed tomography (CT) images enable capturing specific manifestations of tuberculosis (TB) that are undetectable using common diagnostic tests, which suffer from limited specificity. In this study, we aimed to automatically quantify the burden of Mycobacterium tuberculosis (Mtb) using biomarkers extracted from x-ray CT images. Procedures: Nine macaques were aerosol-infected with Mtb and treated with various antibiotic cocktails. Chest CT scans were acquired in all animals at specific times independently of disease progression. First, a fully automatic segmentation of the healthy lungs from the acquired chest CT volumes was performed and air-like structures were extracted. Next, unsegmented pulmonary regions corresponding to damaged parenchymal tissue and TB lesions were included. CT biomarkers were extracted by classification of the probability distribution of the intensity of the segmented images into three tissue types: (1) Healthy tissue, parenchyma free from infection; (2) soft diseased tissue, and (3) hard diseased tissue. The probability distribution of tissue intensities was assumed to follow a Gaussian mixture model. The thresholds identifying each region were automatically computed using an expectation-maximization algorithm. Results: The estimated longitudinal course of TB infection shows that subjects that have followed the same antibiotic treatment present a similar response (relative change in the diseased volume) with respect to baseline. More interestingly, the correlation between the diseased volume (soft tissue + hard tissue), which was manually delineated by an expert, and the automatically extracted volume with the proposed method was very strong (R2 ≈ 0.8)., The research leading to these results received funding from the Innovative Medicines Initiative (www.imi.europa.eu) Joint Undertaking under grant agreement no. 115337, whose resources comprise funding from EU FP7/2007-2013 and EFPIA companies in-kind contribution. This study was partially funded by projects TEC2013-48552-C2-1-R, RTC-2015-3772-1, TEC2015-73064-EXP and TEC2016-78052-R from the Spanish Ministry of Economy, Industry and Competitiveness (MEIC), TOPUS S2013/MIT-3024 project from the regional government of Madrid and by the Department of Health, UK. LEV is funded by the Intramural Research Program of NIAID, NIH. The CNIC is supported by the MEIC and the Pro CNIC Foundation and is a Severo Ochoa Center of Excellence (SEV-2015-0505)
e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publication Artículo científico (JournalArticle)

Helical Optical Projection Tomography

  • Arranz, Alicia
  • Dong, Di
  • Zhu, Shouping
  • Rudin, Markus
  • Tsatsanis, Christos
  • Tian, Jie
  • Ripoll Lorenzo, Jorge
A new technique termed Helical Optical Projection Tomography (hOPT) has been developed with the aim to overcome some of the limitations of current 3D optical imaging techniques. hOPT is based on Optical Projection Tomography (OPT) with the major difference that there is a translation of the sample in the vertical direction during the image acquisition process, requiring a new approach to image reconstruction. Contrary to OPT, hOPT makes possible to obtain 3D-optical images of intact long samples without imposing limits on the sample length. This has been tested using hOPT to image long murine tissue samples such as spinal cords and large intestines. Moreover, 3D-reconstructed images of the colon of DSS-treated mice, a model for Inflammatory Bowel Disease, allowed the identification of the structural alterations. Finally, the geometry of the hOPT device facilitates the addition of a Selective Plane Illumination Microscopy (SPIM) arm, providing the possibility of delivering high resolution images of selected areas together with complete volumetric information, This work was partially supported by EC FP7 collaborative grant FMT-XCT and the Bill and Melinda Gates foundation. A.A. wishes to acknowledge support from Marie Curie IEF-2010-275137. J.R. wishes to acknowledge support from EC FP7 IMI project PREDICT-TB, and the EC FP7 CIG grant HIGH-THROUGHPUT TOMO. D.D., S.Z. and J.T. acknowledge support from the National Basic Research Program of China (973 Program) under Grant 2011CB707700, the Fellowship for Young International Scientists of the Chinese Academy of Sciences under Grant 2010Y2GA03, the National Natural Science Foundation of China under Grant 81101084 and Instrument Developing Project of the Chinese Academy of Sciences under Grant No. YZ201164, Publicado
e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publication Artículo científico (JournalArticle)

A Novel Prior- and Motion-Based Compressed Sensing Method for Small-Animal Respiratory Gated CT

  • Pérez-Juste Abascal, Juan Felipe
  • Abella García, Mónica
  • Marinetto Carrillo, Eugenio Daniel
  • Pascau González-Garzón, Javier
  • Desco Menéndez, Manuel
Low-dose protocols for respiratory gating in cardiothoracic small-animal imaging lead to streak artifacts in the images reconstructed with a Feldkamp-Davis-Kress (FDK) method. We propose a novel prior-and motion-based reconstruction (PRIMOR) method, which improves prior-based reconstruction (PBR) by adding a penalty function that includes a model of motion. The prior image is generated as the average of all the respiratory gates, reconstructed with FDK. Motion between respiratory gates is estimated using a nonrigid registration method based on hierarchical B-splines. We compare PRIMOR with an equivalent PBR method without motion estimation using as reference the reconstruction of high dose data. From these data acquired with a micro-CT scanner, different scenarios were simulated by changing photon flux and number of projections. Methods were evaluated in terms of contrast-to-noise-ratio (CNR), mean square error (MSE), streak artefact indicator (SAI), solution error norm (SEN), and correction of respiratory motion. Also, to evaluate the effect of each method on lung studies quantification, we have computed the Jaccard similarity index of the mask obtained from segmenting each image as compared to those obtained from the high dose reconstruction. Both iterative methods greatly improved FDK reconstruction in all cases. PBR was prone to streak artifacts and presented blurring effects in bone and lung tissues when using both a low number of projections and low dose. Adopting PBR as a reference, PRIMOR increased CNR up to 33% and decreased MSE, SAI and SEN up to 20%, 4% and 13%, respectively. PRIMOR also presented better compensation for respiratory motion and higher Jaccard similarity index. In conclusion, the new method proposed for low-dose respiratory gating in small-animal scanners shows an improvement in image quality and allows a reduction of dose or a reduction of the number of projections between two and three times with respect to previous PBR approaches., This work was funded by the Spanish Ministerio de Economía y Competitividad (www.mineco.gob.es/) with projects IDI-20130301, TEC2013-47270-R, IPT-2012-0401-300000, RTC-2014-3028-1, and RD12/0042/0057. Also, the research leading to these results has received funding from the Innovative Medicines Initiative (www.imi.europa.eu) Joint Undertaking under grant agreement n°115337, resources of which are composed of financial contribution from the European Union's Seventh Framework Programme (FP7/2007-2013) and EFPIA companies' in kind contribution. The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript., Publicado
e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publication Artículo científico (JournalArticle)

Population pharmacokinetics, optimised design and sample size determination for rifampicin, isoniazid, ethambutol and pyrazinamide in the mouse

  • Chen, Chunli
  • Ortega, Fátima
  • Alameda, Laura
  • Ferrer Bazaga, Santiago
  • Simonsson, Ulrika S. H.
The current first-line therapy for drug-susceptible tuberculosis consists of rifampicin (RIF), isoniazid (INH), pyrazinamide (PZA) and ethambutol (EMB). In this study, we determined the population pharmacokinetics (PopPK) of RIF, INH, EMB and PZA using original experimental sampling designs for single-dose intravenous (IV) and single- and multiple-dose oral administration studies in the mouse model, and used these PopPK models to develop and evaluate new, more informative sampling designs with the aim of reducing the number of animals required for each drug. The RIF, INH, EMB and PZA blood concentrations after single oral and IV doses and multiple-dose oral administrations based on the original designs were used in the PopPK analysis using NONMEM software. The final PopPK models described the data well. Stochastic simulation and estimation were used to optimise the designs. The relative bias and relative imprecision of each pharmacokinetic parameter for each drug were derived and assessed to choose the final designs. The final single-dose IV and oral designs included up to eight samples per mouse with a total of 24 mice required for RIF and EMB and 33 mice for INH and PZA. In the new multiple-dose (zipper) oral designs, the mice were divided into two groups of three per dose, and four samples were taken from each mouse to cover all seven or eight sampling time points. The final number of mice required for the multiple-dose oral designs was 30 for RIF, INH and EMB, 36 for PZA. The number of mice required in the new designs for RIF, INH and EMB was decreased by up to 7-fold and the relative bias and relative imprecision in the parameter estimates were at least similar to those in the original designs., The research was funded by the Swedish Research Council, the Innovative Medicines Initiative Joint Undertaking (www.imi.europa.eu) under grant agreement n°115337, resources of which are composed of financial contribution from the European Union's Seventh Framework Programme (FP7/2007–2013) and EFPIA companies' in kind contribution and the Chinese Scholarship Council. The funding parties were not involved in the study design, the analysis or interpretation of data or the writing of this article. The experimental work was financed by GlaxoSmithKline.
e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publication Artículo científico (JournalArticle)

Chemoenzymatic radiosynthesis of 2-deoxy-2-[F-18]fluoro-D-trehalose ([F-18]-2-FDTre): a PET radioprobe for in vivo tracing of trehalose metabolism

  • Peña Zalbidea, Santiago
  • Huang, Ashley Y-T
  • Kavunja, Herbert W.
  • Salinas Rodríguez, Beatriz
  • Desco Menéndez, Manuel
  • Drake, Christopher
  • Woodruff, Peter J.
  • Vaquero López, Juan José
  • Swarts, Benjamin M.
Trehalose analogues bearing fluorescent and click chemistry tags have been developed as probes of bacterial trehalose metabolism, but these tools have limitations with respect to in vivo imaging applications. Here, we report the radiosynthesis of the F-18-modified trehalose analogue 2-deoxy-2-[F-18]fluoro-D-trehalose ([F-18]-2-FDTre), which in principle can be used in conjunction with positron emission tomography (PET) imaging to allow in vivo imaging of trehalose metabolism in various contexts. A chemoenzymatic method employing the thermophilic TreT enzyme from Thermoproteus tenax was used to rapidly (15-20 min), efficiently (70% radiochemical yield; >= 95% radiochemical purity), and reproducibly convert the commercially available radiotracer 2-deoxy-2-[F-18]fluoro-D-glucose ([F-18]-2-FDG) into the target radioprobe [F-18]-2-FDTre in a single step; both manual and automated syntheses were performed with similar results. Cellular uptake experiments showed that radiosynthetic [F-18]-2-FDTre was metabolized by Mycobacterium smegmatis but not by various mammalian cell lines, pointing to the potential future use of this radioprobe for selective PET imaging of infections caused by trehalose-metabolizing bacterial pathogens such as M. tuberculosis., This work was funded by a grant from the National Institutes of Health, United States (R15 AI117670) to B.M.S. and P.J.W., as well as a Henry Dreyfus Teacher-Scholar Award from The Camille & Henry Dreyfus Foundation to B.M.S. (TH-17-034). A.Y.-T.H was supported by the Mount Holyoke College Lynk program. Dr. Wenyan Xu is thanked for assistance with kinetic analysis. The research leading to these results received funding from the Innovative Medicines Initiative, European Union (www.imi.europa.eu) Joint Undertaking under grant agreement no. 115337, whose resources comprise funding from EU FP7/2007-2013 and EFPIA, European Union companies in-kind contribution. This work was partially supported by the Ministry of Economy and Competitiveness, Spain TEC2015-73064-EXP and TEC2016-78052-R, ISCIII-FIS grants PI16/02037, co-financed by ERDF, European Union (FEDER) Funds from the European Commission, European Union, "A way of making Europe".
e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publication Artículo científico (JournalArticle)

Polarization-sensitive optical projection tomography for muscle fiber imaging

  • Fang, Mengjie
  • Dong, Di
  • Zeng, Chaoting
  • Liang, Xiao
  • Yang, Xin
  • Arranz de Miguel, Alicia
  • Ripoll Lorenzo, Jorge
  • Hui, Hui
  • Tian, Jie
Optical projection tomography (OPT) is a tool used for three-dimensional imaging of millimeter-scale biological samples, with the advantage of exhibiting isotropic resolution typically in the micron range. OPT can be divided into two types: transmission OPT (tOPT) and emission OPT (eOPT). Compared with eOPT, tOPT discriminates different tissues based on their absorption coefficient, either intrinsic or after specific staining. However, it fails to distinguish muscle fibers whose absorption coefficients are similar to surrounding tissues. To circumvent this problem, in this article we demonstrate a polarization sensitive OPT system which improves the detection and 3D imaging of muscle fibers by using polarized light. We also developed image acquisition and processing protocols that, together with the system, enable the clear visualization of muscles. Experimental results show that the muscle fibers of diaphragm and stomach, difficult to be distinguished in regular tOPT, were clearly displayed in our system, proving its potential use. Moreover, polarization sensitive OPT was fused with tOPT to investigate the stomach tissue comprehensively. Future applications of polarization sensitive OPT could be imaging other fiberlike structures such as myocardium or other tissues presenting high optical anisotropy., This work is supported by the National Basic Research Program of China (973 Program) under Grant 2011CB707700, the National Natural Science Foundation of China under Grant No. 81227901, 61231004, 81501616, 81301346, 81527805 the Chinese Academy of Sciences Fellowship for Young Foreign Scientists under Grant No. 2010Y2GA03, 2013Y1GA0004, the Chinese Academy of Sciences Visiting Professorship for Senior International Scientists under Grant No. 2012T1G0036, 2013T1G0013, the Instrument Developing Project of the Chinese Academy of Sciences under Grant No. YZ201502, YZ201457 and the Strategic Priority Research Program (B) of Chinese Academy of Sciences (XDB02060010). A. Arranz acknowledges support from the Marie Curie Intra-European Fellowship program IEF-2010-275137. J.R. acknowledges support from EC FP7 IMI project PREDICT-TB, the EC FP7 CIG grant HIGH-THROUGHPUT TOMO, and the Spanish MINECO project grant FIS2013-41802-R MESO-IMAGING.
e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publication Artículo científico (JournalArticle)

X-ray-based virtual slicing of TB-infected lungs

  • Ortega Gil, Ana
  • Vaquero López, Juan José
  • González Arjona, Mario
  • Rullas, Joaquín
  • Muñoz Barrutia, María Arrate
Hollow organs such as the lungs pose a considerable challenge for post-mortem imaging in preclinical research owing to their extremely low contrast and high structural complexity. The aim of our study was to enhance the contrast of tuberculosis lesions for their stratification by 3D x-ray&-based virtual slicing. Organ samples were taken from five control and five tuberculosis-infected mice. Micro-Computed Tomography (CT) scans of the subjects were acquired in vivo (without contrast agent) and post-mortem (with contrast agent). The proposed contrast-enhancing technique consists of x-ray contrast agent uptake (silver nitrate and iodine) by immersion. To create the histology ground-truth, the CT scan of the paraffin block guided the sectioning towards specific planes of interest. The digitalized histological slides reveal the presence, extent, and appearance of the contrast agents in lung structures and organized aggregates of immune cells. These findings correlate with the contrast-enhanced micro-CT slice. The abnormal densities in the lungs due to tuberculosis disease are concentrated in the right tail of the lung intensity histograms. The increase in the width of the right tail (~376%) indicates a contrast enhancement of the details of the abnormal densities. Postmortem contrast agents enhance the x-ray attenuation in tuberculosis lesions to allow 3D visualization by polychromatic x-ray CT, providing an advantageous tool for virtual slicing of whole lungs. The proposed contrast-enhancing technique combined with computational methods and the diverse micro-CT modalities will open the doors to the stratification of lesion types associated with infectious diseases., The research leading to these results received funding from the Innovative Medicines Initiative (www.imi.europa.eu) Joint Undertaking under grant agreement no. 115337, whose resources comprise funding from the European Union Seventh Framework Programme (FP7/2007–2013) and EFPIA companies in kind contribution. This work was partially funded by projects RTC-2015-3772-1, TEC2015-73064-EXP and TEC2016-78052-R from the Spanish Ministry of Economy, TOPUS S2013/MIT-3024 project from the regional government of Madrid and by the Department of Health, UK. This study (was supported by the Instituto de Salud Carlos III (Plan Estatal de I + D + i 2013–2016) and co-financed by the European Social Fund (ESF) “ESF investing in your future”. The authors thank Dr.Guembe from CIMA-Universidad de Navarra for preparing and staining the tissue sections, and to Dr. Guerrero-Aspizua and Prof. Conti of the Department of Bioengineering, Universidad Carlos III de Madrid for the pathology evaluation.
Repisalud
Publication Artículo científico (JournalArticle)

Improving PET Quantification of Small Animal [Ga-68]DOTA-Labeled PET/CT Studies by Using a CT-Based Positron Range Correction

  • Cal-Gonzalez, Jacobo
  • Vaquero, Juan Jose
  • Herraiz, Joaquin L.
  • Perez-Liva, Mailyn
  • Soto-Montenegro, Maria Luisa
  • Pena-Zalbidea, Santiago
  • Desco, Manuel
  • Udias, Jose Manuel
Image quality of positron emission tomography (PET) tracers that emits high-energy positrons, such as Ga-68, Rb-82, or I-124, is significantly affected by positron range (PR) effects. PR effects are especially important in small animal PET studies, since they can limit spatial resolution and quantitative accuracy of the images. Since generators accessibility has made Ga-68 tracers wide available, the aim of this study is to show how the quantitative results of [Ga-68]DOTA-labeled PET/X-ray computed tomography (CT) imaging of neuroendocrine tumors in mice can be improved using positron range correction (PRC). Eighteen scans in 12 mice were evaluated, with three different models of tumors: PC12, AR42J, and meningiomas. In addition, three different [Ga-68]DOTA-labeled radiotracers were used to evaluate the PRC with different tracer distributions: [Ga-68]DOTANOC, [Ga-68]DOTATOC, and [Ga-68]DOTATATE. Two PRC methods were evaluated: a tissue-dependent (TD-PRC) and a tissue-dependent spatially-variant correction (TDSV-PRC). Taking a region in the liver as reference, the tissue-to-liver ratio values for tumor tissue (TLRtumor), lung (TLRlung), and necrotic areas within the tumors (TLRnecrotic) and their respective relative variations (Delta TLR) were evaluated. All TLR values in the PRC images were significantly different (p < 0.05) than the ones from non-PRC images. The relative differences of the tumor TLR values, respect to the case with no PRC, were Delta TLRtumor 87 +/- 41 \% (TD-PRC) and 85 +/- 46 \% (TDSV-PRC). TLRlung decreased when applying PRC, being this effect more remarkable for the TDSV-PRC method, with relative differences respect to no PRC: Delta TLRlung = - 45 +/- 24 (TD-PRC), - 55 +/- 18 (TDSV-PRC). TLRnecrotic values also decreased when using PRC, with more noticeable differences for TD-PRC: Delta TLRnecrotic = - 52 +/- 6 (TD-PRC), - 48 +/- 8 (TDSV-PRC). The PRC methods proposed provide a significant quantitative improvement in [Ga-68]DOTA-labeled PET/CT imaging of mice with neuroendocrine tumors, hence demonstrating that these techniques could also ameliorate the deleterious effect of the positron range in clinical PET imaging.