Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

Remote electrical stimulation by means of implanted rectifiers

  • Ivorra Cano, Antoni, 1974-
Miniaturization of active implantable medical devices is currently compromised by the available means for electrically/npowering them. Most common energy supply techniques for implants – batteries and inductive couplers – comprise bulky/nparts which, in most cases, are significantly larger than the circuitry they feed. Here, for overcoming such miniaturization/nbottleneck in the case of implants for electrical stimulation, it is proposed to make those implants act as rectifiers of high/nfrequency bursts supplied by remote electrodes. In this way, low frequency currents will be generated locally around the/nimplant and these low frequency currents will perform stimulation of excitable tissues whereas the high frequency currents/nwill cause only innocuous heating. The present study numerically demonstrates that low frequency currents capable of/nstimulation can be produced by a miniature device behaving as a diode when high frequency currents, neither capable of/nthermal damage nor of stimulation, flow through the tissue where the device is implanted. Moreover, experimental/nevidence is provided by an in vivo proof of concept model consisting of an anesthetized earthworm in which a commercial/ndiode was implanted. With currently available microelectronic techniques, very thin stimulation capsules (diameter/n,500 mm) deliverable by injection are easily conceivable., This author's research is currently supported by a Ramón y Cajal fellowship from the Spanish Ministry for Science and Innovation (RYC-2009-04271) and a Marie Curie International Reintegration Grant (256376 – “TAMIVIVE”) from the European Commission. The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.
Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

Tumor growth delay by adjuvant alternating electric fields which appears non-thermally mediated

  • Castellví Fernández, Quim
  • Ginestà, Mireia M.
  • Capellá, Gabriel
  • Ivorra Cano, Antoni, 1974-
Delivery of the so-called Tumor Treatment Fields (TTFields) has been proposed as a cancer/ntherapy. These are low magnitude alternating electric fields at frequencies from 100 to 300 kHz/nwhich are applied continuously in a non-invasive manner. Electric field delivery may produce an/nincrease in temperature which cannot be neglected. We hypothesized that the reported results/nobtained by applying TTFields in vivo could be due to heat rather than to electrical forces as/npreviously suggested. Here it is presented an in vivo study in which pancreatic tumors/nsubcutaneously implanted in nude mice were treated for a week either with mild hyperthermia/n(41°C) or with TTFields (6 V/cm, 150 kHz) and tumor growth was assessed. Although the TTFields/napplied singly did not produce any significant effect, the combination with chemotherapy did show/na delay in tumor growth in comparison to animals treated only with chemotherapy (median relative/nreduction = 47%). We conclude that concomitant chemotherapy and TTFields delivery show a/nbeneficial impact on pancreatic tumor growth. Contrary to our hypothesis, this impact is nonrelated/nwith the induced temperature increase., This research was supported by project grants (AR00311 - MICINN-TEC2010-11182-E, SAF2012-/n33636, RTICCC RD12/0036/0031) from the Spanish government and in part by a Marie Curie grant/n(IRG 256376) from the European Commission and by the Generalitat de Catalunya (2009 SGR/n1356).
Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

Fast flow-through non-thermal pasteurization using constant radiofrequency electric fields

  • Ivorra Cano, Antoni, 1974-
  • González-Sosa, Jarold
  • Ruiz-Vargas, Albert
  • Arias, Guillem
Pulsed Electric Field technologies have captured the attention of researchers on food/npasteurization because of their non-thermal inactivation mechanism, which results in fresh-like/nproducts. Nevertheless, high voltage pulsing required by these technologies implies complex and costly/ngenerators. Here, as an alternative, it is proposed a method, partially inherited from research on cell/nelectroporation for gene transfection, in which the liquid to be treated flows at high speed through a/nminiature chamber where the electric field is permanently applied. In particular, it is proposed that the/nconstantly applied electric field consists of an AC signal (> 100 kHz) so that electrochemical byproducts/nare minimized. The method, while being compatible with batch processing, will allow use of/nlower voltages and will avoid the pulsation requirement. The proposal is accompanied by a numerical/nstudy and an in vitro study which demonstrate its feasibility, This work received financial support form the European Commission through the Marie Curie IRG grant/nTAMIVIVE (256376).
Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

Can electroporation previous to radiofrequency hepatic ablation enlarge thermal lesion size? A feasibility study based on theoretical modelling and in vivo experiments

  • Trujillo Guillén, Macarena
  • Castellví Fernández, Quim
  • Burdío Pinilla, Fernando
  • Ivorra Cano, Antoni, 1974-
  • Andaluz, Anna
  • Sanchez Velazquez Patricia
  • Berjano, Enrique J.
Purpose: To assess the feasibility of a hybrid ablative technique based on applying electroporation (EP) pulses just before conducting radiofrequency ablation (RFA). The rationale was that the EP-induced reduction in blood perfusion could be sufficient to reduce the thermal sink effect and hence to increase the coagulation volume in comparison to that created exclusively by RFA./nMaterials and methods: Modeling study and in vivo experimental study. A Cool-tip RF applicator was used both for EP and RFA./nResults: Overall, the results did not show any synergy effect from using the hybrid technique. Applying EP pulses prior to RFA did not increase the coagulation zone obtained and the lesions were almost identical. Additional computer simulations provided an explanation for this; the effect of reducing blood perfusion by thermal damage during RFA completely masks the effect of reducing blood perfusion by EP. This is because both thermal damage and EP affect the same zone, i.e. the tissue around the electrode./nConclusions: Our computer modeling and in vivo experimental findings suggest that the combination of EP and RFA with monopolar applicators does not provide an additional benefit over the use of RFA alone., This work received financial support from the Spanish “Plan Nacional de I+D+I del Ministerio de Ciencia e Innovación” Grants No. TEC2011-27133-C02-01,02 and TEC2010-17285, from the European Commission through the Marie Curie IRG grant TAMIVIVE (256376) and from the Universitat Politècnica de València (INNOVA11-01-5502; and PAID-06-11 Ref. 1988). The linguistic revision of this paper was funded by the Universitat Politècnica de València, Spain.
Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

Anatomically realistic simulations of liver ablation by irreversible electroporation: impact of blood vessels on ablation volumes and undertreatment

  • Ivorra Cano, Antoni, 1974-
  • Qasrawi, Radwan Fayez Hasan
  • Silve, Louis Charles Arthur
  • Burdío Pinilla, Fernando
  • Abdeen, Ziad
Irreversible electroporation is a novel tissue ablation technique which entails delivering intense electrical pulses to target tissue, hence producing fatal defects in the cell membrane. The present study numerically analyzes the potential impact of liver blood vessels on ablation by irreversible electroporation because of their influence on the electric field distribution. An anatomically realistic computer model of the liver and its vasculature within an abdominal section was employed, and blood vessels down to 0.4 mm in diameter were considered. In this model, the electric field distribution was simulated in a large series of scenarios (N = 576) corresponding to plausible percutaneous irreversible electroporation treatments by needle electrode pairs. These modeled treatments were relatively superficial (maximum penetration depth of the electrode within the liver = 26 mm) and it was ensured that the electrodes did not penetrate the vessels nor were in contact with them. In terms of total ablation volume, the maximum deviation caused by the presence of the vessels was 6%, which could be considered negligible compared to the impact by other sources of uncertainty. Sublethal field magnitudes were noticed around vessels covering volumes of up to 228 mm3. If in this model the blood was substituted by a liquid with a low electrical conductivity (0.1 S/m), the maximum volume covered by sublethal field magnitudes was 3.7 mm3 and almost no sublethal regions were observable. We conclude that undertreatment around blood vessels may occur in current liver ablation procedures by irreversible electroporation. Infusion of isotonic low conductivity liquids into the liver vasculature could prevent this risk., This work received financial support from the Spanish Government through grants TEC2010-17285, TEC2011-27133-C02, and TEC2014-52383-C3 (TEC2014-52383-C3-2) and from the European Commission through the Marie Curie IRG grant “TAMIVIVE” 256376.
Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

In vivo demonstration of addressable microstimulators powered by rectification of epidermically applied currents for miniaturized neuroprostheses

  • Becerra Fajardo, Laura
  • Ivorra Cano, Antoni, 1974-
Electrical stimulation is used in order to restore nerve mediated functions in patients with neurological disorders, but its applicability is constrained by the invasiveness of the systems required to perform it. As an alternative to implantable systems consisting of central stimulation units wired to the stimulation electrodes, networks of wireless microstimulators have been devised for fine movement restoration. Miniaturization of these microstimulators is currently hampered by the available methods for powering them. Previously, we have proposed and demonstrated a heterodox electrical stimulation method based on electronic rectification of high frequency current bursts. These bursts can be delivered through textile electrodes on the skin. This approach has the potential to result in an unprecedented level of miniaturization as no bulky parts such as coils or batteries are included in the implant. We envision microstimulators designs based on application-specific integrated circuits (ASICs) that will be flexible, thread-like (diameters <0.5 mm) and not only with controlled stimulation capabilities but also with sensing capabilities for artificial proprioception. We in vivo demonstrate that neuroprostheses composed of addressable microstimulators based on this electrical stimulation method are feasible and can perform controlled charge-balanced electrical stimulation of muscles. We developed miniature external circuit prototypes connected to two bipolar probes that were percutaneously implanted in agonist and antagonist muscles of the hindlimb of an anesthetized rabbit. The electronic implant architecture was able to/ndecode commands that were amplitude modulated on the high frequency (1 MHz) auxiliary current bursts. The devices were capable of independently stimulating the target tissues, accomplishing controlled dorsiflexion and plantarflexion joint movements. In addition, we/nnumerically show that the high frequency current bursts comply with safety standards both in terms of tissue heating and unwanted electro-stimulation. We demonstrate that addressable microstimulators powered by rectification of epidermically applied currents are feasible., This work was supported in part by the Ramón y Cajal fellowship (RYC-2009-04271) from the Spanish government and by a Marie Curie grant (IRG 256376) from the European Commission.
Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

Demonstration of 2 mm thick microcontrolled injectable stimulators based on rectification of high frequency current bursts

  • Becerra Fajardo, Laura
  • Schmidbauer, Marieluise
  • Ivorra Cano, Antoni, 1974-
Existing implantable stimulators use powering approaches that result in stiff and bulky systems or result in systems incapable of producing the current magnitudes required for neuromuscular stimulation. This hampers their use in neuroprostheses for paralysis. We previously demonstrated an electrical stimulation method based on electronic rectification of high frequency (HF) current bursts. The implants act as rectifiers of HF current that flows through the tissues by galvanic coupling, transforming this current into low frequency current capable of performing neuromuscular stimulation. Here we developed 2 mm thick, semi-rigid, injectable and addressable stimulators made of off-the-shelf components and based on this method. The devices were tested in vitro to illustrate how they are powered by galvanic coupling. In addition they were tried in an animal model to demonstrate their ability to perform controlled electrical stimulation. The implants were deployed by injection into two antagonist muscles of an anesthetized rabbit and were addressed resulting in independent isometric contractions. Low frequency currents of 2 mA were delivered by the implants. The HF currents are safe in terms of unwanted electrostimulation and tissue heating according to standards. This indicates that the proposed electrical stimulation method will allow unprecedented levels of miniaturization for neuroprostheses., LBF‘s research is supported by a PRC fellowship from the UPF. AI‘s research was supported by a Marie Curie grant (IRG 256376) from the European Commission.
Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

Irreversible electroporation shows efficacy against pancreatic carcinoma without systemic toxicity in mouse models

  • José Segarra-Martínez, Anabel
  • Sobrevals, Luciano
  • Ivorra Cano, Antoni, 1974-
  • Fillat i Fonts, Cristina
Pancreatic Ductal Adenocarcinoma (PDAC) therapies show limited success./nIrreversible electroporation (IRE) is an innovative loco-regional therapy in which highvoltage pulses are applied to induce plasma membrane defects leading to cellular death. In the present study we evaluated the feasibility of IRE against PDAC. IRE/ntreatment exhibited significant antitumor effects and prolonged survival in mice with orthotopic xenografts. Extensive tumor necrosis, reduced tumor cell proliferation and disruption of microvessels were observed at different days post-IRE. Animals had transient increases in transaminases, amylase and lipase enzymes that normalized at/n24h post-IRE. These results suggest that IRE could be an effective treatment for locally advanced pancreatic tumors., This work was supported by the Spanish/nMinistry of Science and Innovation (MICINN), BIO2008-04692-C03-02/01 and received/npartial support from the Generalitat de Catalunya SGR091527. Anabel José was a/nrecipient of a FPU fellowship from the MICINN. Fillat’s group is also partially funded by/nCIBERER and by IIS10/00014 from Instituto de Salud Carlos III. Ivorra’s research is/ncurrently supported by a Ramón y Cajal fellowship from the Spanish Ministry for/nScience and Innovation and a Marie Curie IRG grant from the European Commission.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Can electroporation previous to radiofrequency hepatic ablation enlarge thermal lesion size? A feasibility study based on theoretical modelling and in vivo experiments

  • Trujillo Guillen, Macarena|||0000-0003-4145-2188
  • Berjano, Enrique|||0000-0002-3247-2665
  • Castellvi, Quim
  • Burdío, Fernando
  • Sánchez Velázquez, Patricia
  • Ivorra, Antoni
  • Andaluz, Anna
Purpose: The aim of this study was to assess the feasibility of a hybrid ablative technique based on applying electroporation (EP) pulses just before conducting radiofrequency ablation (RFA). The rationale was that the EP-induced reduction in blood perfusion could be sufficient to reduce the thermal sink effect and hence to increase the coagulation volume in comparison to that created exclusively by RFA. Materials and methods: A modelling study and in vivo experimental study were used. A Cool-tip RF applicator was used both for EP and RFA. Results: Overall, the results did not show any synergy effect from using the hybrid technique. Applying EP pulses prior to RFA did not increase the coagulation zone obtained and the lesions were almost identical. Additional computer simulations provided an explanation for this; the effect of reducing blood perfusion by thermal damage during RFA completely masks the effect of reducing blood perfusion by EP. This is because both thermal damage and EP affect the same zone, i.e. the tissue around the electrode. Conclusions: Our computer modelling and in vivo experimental findings suggest that the combination of EP and RFA with monopolar applicators does not provide an additional benefit over the use of RFA alone., This work received financial support from the Spanish 'Plan Nacional de I + D + I del Ministerio de Ciencia e Innovacion' Grant nos. TEC2011-27133-C02-01,02 and TEC2010-17285, from the European Commission through the Marie Curie IRG grant TAMIVIVE (256376) and from the Universitat Politecnica de Valencia (INNOVA11-01-5502; and PAID-06-11 Ref. 1988). The linguistic revision of this paper was funded by the Universitat Politecnica de Valencia, Spain. The authors alone are responsible for the content and writing of the paper.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Comparison of the effects of the repetition rate between microsecond and nanosecond pulses: electropermeabilization-induced electro-desensitization?

  • Silve, Aude
  • Guimerà Brunet, Antón
  • Al-Sakere, Bassim
  • Ivorra, Antoni
  • Mir, Lluis Maria
Applications of cell electropermeabilization are rapidly growing but basic concepts are still unclear. In particular, the impact of electric pulse repetition rate in the efficiency of permeabilization has not yet been understood., Peer reviewed
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Anatomically realistic simulations of liver ablation by irreversible electroporation: impact of blood vessels on ablation volumes and undertreatment

  • Ivorra Cano, Antoni, 1974-
  • Qasrawi, Radwan Fayez Hasan
  • Silve, Louis Charles Arthur
  • Burdío Pinilla, Fernando
  • Abdeen, Ziad
Irreversible electroporation is a novel tissue ablation technique which entails delivering intense electrical pulses to target tissue, hence producing fatal defects in the cell membrane. The present study numerically analyzes the potential impact of liver blood vessels on ablation by irreversible electroporation because of their influence on the electric field distribution. An anatomically realistic computer model of the liver and its vasculature within an abdominal section was employed, and blood vessels down to 0.4 mm in diameter were considered. In this model, the electric field distribution was simulated in a large series of scenarios (N = 576) corresponding to plausible percutaneous irreversible electroporation treatments by needle electrode pairs. These modeled treatments were relatively superficial (maximum penetration depth of the electrode within the liver = 26 mm) and it was ensured that the electrodes did not penetrate the vessels nor were in contact with them. In terms of total ablation volume, the maximum deviation caused by the presence of the vessels was 6%, which could be considered negligible compared to the impact by other sources of uncertainty. Sublethal field magnitudes were noticed around vessels covering volumes of up to 228 mm3. If in this model the blood was substituted by a liquid with a low electrical conductivity (0.1 S/m), the maximum volume covered by sublethal field magnitudes was 3.7 mm3 and almost no sublethal regions were observable. We conclude that undertreatment around blood vessels may occur in current liver ablation procedures by irreversible electroporation. Infusion of isotonic low conductivity liquids into the liver vasculature could prevent this risk., This work received financial support from the Spanish Government through grants TEC2010-17285, TEC2011-27133-C02, and TEC2014-52383-C3 (TEC2014-52383-C3-2) and from the European Commission through the Marie Curie IRG grant “TAMIVIVE” 256376.
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Tumor growth delay by adjuvant alternating electric fields which appears non-thermally mediated

  • Castellví Fernández, Quim
  • Ginestà, Mireia M.
  • Capellá, Gabriel
  • Ivorra Cano, Antoni, 1974-
Delivery of the so-called Tumor Treatment Fields (TTFields) has been proposed as a cancer/ntherapy. These are low magnitude alternating electric fields at frequencies from 100 to 300 kHz/nwhich are applied continuously in a non-invasive manner. Electric field delivery may produce an/nincrease in temperature which cannot be neglected. We hypothesized that the reported results/nobtained by applying TTFields in vivo could be due to heat rather than to electrical forces as/npreviously suggested. Here it is presented an in vivo study in which pancreatic tumors/nsubcutaneously implanted in nude mice were treated for a week either with mild hyperthermia/n(41°C) or with TTFields (6 V/cm, 150 kHz) and tumor growth was assessed. Although the TTFields/napplied singly did not produce any significant effect, the combination with chemotherapy did show/na delay in tumor growth in comparison to animals treated only with chemotherapy (median relative/nreduction = 47%). We conclude that concomitant chemotherapy and TTFields delivery show a/nbeneficial impact on pancreatic tumor growth. Contrary to our hypothesis, this impact is nonrelated/nwith the induced temperature increase., This research was supported by project grants (AR00311 - MICINN-TEC2010-11182-E, SAF2012-/n33636, RTICCC RD12/0036/0031) from the Spanish government and in part by a Marie Curie grant/n(IRG 256376) from the European Commission and by the Generalitat de Catalunya (2009 SGR/n1356).
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Irreversible electroporation shows efficacy against pancreatic carcinoma without systemic toxicity in mouse models

  • José Segarra-Martínez, Anabel
  • Sobrevals, Luciano
  • Ivorra Cano, Antoni, 1974-
  • Fillat i Fonts, Cristina
Pancreatic Ductal Adenocarcinoma (PDAC) therapies show limited success./nIrreversible electroporation (IRE) is an innovative loco-regional therapy in which highvoltage pulses are applied to induce plasma membrane defects leading to cellular death. In the present study we evaluated the feasibility of IRE against PDAC. IRE/ntreatment exhibited significant antitumor effects and prolonged survival in mice with orthotopic xenografts. Extensive tumor necrosis, reduced tumor cell proliferation and disruption of microvessels were observed at different days post-IRE. Animals had transient increases in transaminases, amylase and lipase enzymes that normalized at/n24h post-IRE. These results suggest that IRE could be an effective treatment for locally advanced pancreatic tumors., This work was supported by the Spanish/nMinistry of Science and Innovation (MICINN), BIO2008-04692-C03-02/01 and received/npartial support from the Generalitat de Catalunya SGR091527. Anabel José was a/nrecipient of a FPU fellowship from the MICINN. Fillat’s group is also partially funded by/nCIBERER and by IIS10/00014 from Instituto de Salud Carlos III. Ivorra’s research is/ncurrently supported by a Ramón y Cajal fellowship from the Spanish Ministry for/nScience and Innovation and a Marie Curie IRG grant from the European Commission.
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Can electroporation previous to radiofrequency hepatic ablation enlarge thermal lesion size? A feasibility study based on theoretical modelling and in vivo experiments

  • Trujillo Guillén, Macarena
  • Castellví Fernández, Quim
  • Burdío Pinilla, Fernando
  • Ivorra Cano, Antoni, 1974-
  • Andaluz, Anna
  • Sanchez Velazquez Patricia
  • Berjano, Enrique J.
Purpose: To assess the feasibility of a hybrid ablative technique based on applying electroporation (EP) pulses just before conducting radiofrequency ablation (RFA). The rationale was that the EP-induced reduction in blood perfusion could be sufficient to reduce the thermal sink effect and hence to increase the coagulation volume in comparison to that created exclusively by RFA./nMaterials and methods: Modeling study and in vivo experimental study. A Cool-tip RF applicator was used both for EP and RFA./nResults: Overall, the results did not show any synergy effect from using the hybrid technique. Applying EP pulses prior to RFA did not increase the coagulation zone obtained and the lesions were almost identical. Additional computer simulations provided an explanation for this; the effect of reducing blood perfusion by thermal damage during RFA completely masks the effect of reducing blood perfusion by EP. This is because both thermal damage and EP affect the same zone, i.e. the tissue around the electrode./nConclusions: Our computer modeling and in vivo experimental findings suggest that the combination of EP and RFA with monopolar applicators does not provide an additional benefit over the use of RFA alone., This work received financial support from the Spanish “Plan Nacional de I+D+I del Ministerio de Ciencia e Innovación” Grants No. TEC2011-27133-C02-01,02 and TEC2010-17285, from the European Commission through the Marie Curie IRG grant TAMIVIVE (256376) and from the Universitat Politècnica de València (INNOVA11-01-5502; and PAID-06-11 Ref. 1988). The linguistic revision of this paper was funded by the Universitat Politècnica de València, Spain.
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Demonstration of 2 mm thick microcontrolled injectable stimulators based on rectification of high frequency current bursts

  • Becerra Fajardo, Laura
  • Schmidbauer, Marieluise
  • Ivorra Cano, Antoni, 1974-
Existing implantable stimulators use powering approaches that result in stiff and bulky systems or result in systems incapable of producing the current magnitudes required for neuromuscular stimulation. This hampers their use in neuroprostheses for paralysis. We previously demonstrated an electrical stimulation method based on electronic rectification of high frequency (HF) current bursts. The implants act as rectifiers of HF current that flows through the tissues by galvanic coupling, transforming this current into low frequency current capable of performing neuromuscular stimulation. Here we developed 2 mm thick, semi-rigid, injectable and addressable stimulators made of off-the-shelf components and based on this method. The devices were tested in vitro to illustrate how they are powered by galvanic coupling. In addition they were tried in an animal model to demonstrate their ability to perform controlled electrical stimulation. The implants were deployed by injection into two antagonist muscles of an anesthetized rabbit and were addressed resulting in independent isometric contractions. Low frequency currents of 2 mA were delivered by the implants. The HF currents are safe in terms of unwanted electrostimulation and tissue heating according to standards. This indicates that the proposed electrical stimulation method will allow unprecedented levels of miniaturization for neuroprostheses., LBF‘s research is supported by a PRC fellowship from the UPF. AI‘s research was supported by a Marie Curie grant (IRG 256376) from the European Commission.
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

In vivo demonstration of addressable microstimulators powered by rectification of epidermically applied currents for miniaturized neuroprostheses

  • Becerra Fajardo, Laura
  • Ivorra Cano, Antoni, 1974-
Electrical stimulation is used in order to restore nerve mediated functions in patients with neurological disorders, but its applicability is constrained by the invasiveness of the systems required to perform it. As an alternative to implantable systems consisting of central stimulation units wired to the stimulation electrodes, networks of wireless microstimulators have been devised for fine movement restoration. Miniaturization of these microstimulators is currently hampered by the available methods for powering them. Previously, we have proposed and demonstrated a heterodox electrical stimulation method based on electronic rectification of high frequency current bursts. These bursts can be delivered through textile electrodes on the skin. This approach has the potential to result in an unprecedented level of miniaturization as no bulky parts such as coils or batteries are included in the implant. We envision microstimulators designs based on application-specific integrated circuits (ASICs) that will be flexible, thread-like (diameters <0.5 mm) and not only with controlled stimulation capabilities but also with sensing capabilities for artificial proprioception. We in vivo demonstrate that neuroprostheses composed of addressable microstimulators based on this electrical stimulation method are feasible and can perform controlled charge-balanced electrical stimulation of muscles. We developed miniature external circuit prototypes connected to two bipolar probes that were percutaneously implanted in agonist and antagonist muscles of the hindlimb of an anesthetized rabbit. The electronic implant architecture was able to/ndecode commands that were amplitude modulated on the high frequency (1 MHz) auxiliary current bursts. The devices were capable of independently stimulating the target tissues, accomplishing controlled dorsiflexion and plantarflexion joint movements. In addition, we/nnumerically show that the high frequency current bursts comply with safety standards both in terms of tissue heating and unwanted electro-stimulation. We demonstrate that addressable microstimulators powered by rectification of epidermically applied currents are feasible., This work was supported in part by the Ramón y Cajal fellowship (RYC-2009-04271) from the Spanish government and by a Marie Curie grant (IRG 256376) from the European Commission.
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Remote electrical stimulation by means of implanted rectifiers

  • Ivorra Cano, Antoni, 1974-
Miniaturization of active implantable medical devices is currently compromised by the available means for electrically/npowering them. Most common energy supply techniques for implants – batteries and inductive couplers – comprise bulky/nparts which, in most cases, are significantly larger than the circuitry they feed. Here, for overcoming such miniaturization/nbottleneck in the case of implants for electrical stimulation, it is proposed to make those implants act as rectifiers of high/nfrequency bursts supplied by remote electrodes. In this way, low frequency currents will be generated locally around the/nimplant and these low frequency currents will perform stimulation of excitable tissues whereas the high frequency currents/nwill cause only innocuous heating. The present study numerically demonstrates that low frequency currents capable of/nstimulation can be produced by a miniature device behaving as a diode when high frequency currents, neither capable of/nthermal damage nor of stimulation, flow through the tissue where the device is implanted. Moreover, experimental/nevidence is provided by an in vivo proof of concept model consisting of an anesthetized earthworm in which a commercial/ndiode was implanted. With currently available microelectronic techniques, very thin stimulation capsules (diameter/n,500 mm) deliverable by injection are easily conceivable., This author's research is currently supported by a Ramón y Cajal fellowship from the Spanish Ministry for Science and Innovation (RYC-2009-04271) and a Marie Curie International Reintegration Grant (256376 – “TAMIVIVE”) from the European Commission. The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Fast flow-through non-thermal pasteurization using constant radiofrequency electric fields

  • Ivorra Cano, Antoni, 1974-
  • González-Sosa, Jarold
  • Ruiz-Vargas, Albert
  • Arias, Guillem
Pulsed Electric Field technologies have captured the attention of researchers on food/npasteurization because of their non-thermal inactivation mechanism, which results in fresh-like/nproducts. Nevertheless, high voltage pulsing required by these technologies implies complex and costly/ngenerators. Here, as an alternative, it is proposed a method, partially inherited from research on cell/nelectroporation for gene transfection, in which the liquid to be treated flows at high speed through a/nminiature chamber where the electric field is permanently applied. In particular, it is proposed that the/nconstantly applied electric field consists of an AC signal (> 100 kHz) so that electrochemical byproducts/nare minimized. The method, while being compatible with batch processing, will allow use of/nlower voltages and will avoid the pulsation requirement. The proposal is accompanied by a numerical/nstudy and an in vitro study which demonstrate its feasibility, This work received financial support form the European Commission through the Marie Curie IRG grant/nTAMIVIVE (256376).