Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 14
Encontrada(s) 1 página(s)

Archivo Digital UPM
Publication Artículo científico (JournalArticle)

PV power forecast using a nonparametric PV model

  • Almeida, Marcelo Pinho
  • Perpiñan Lamigueiro, Oscar|||0000-0002-4134-7196
  • Narvarte Fernández, Luis|||0000-0002-6289-7605
Archivo Digital UPM
Publication Artículo científico (JournalArticle)

Storage requirements for PV power ramp-rate control

  • Marcos Álvarez, Javier
  • Storkël, O.
  • Marroyo, Luis
  • García Solano, Miguel
  • Lorenzo Pigueiras, Eduardo
Archivo Digital UPM
Publication Artículo científico (JournalArticle)

Experimental observations on hot-spots and derived

  • Moretón Villagrá, Rodrigo
  • Lorenzo Pigueiras, Eduardo
  • Narvarte Fernández, Luis|||0000-0002-6289-7605
Archivo Digital UPM
Publication Artículo científico (JournalArticle)

A bankable method of assessing the performance of a CPV plant

  • Leloux, Jonathan
  • Lorenzo Pigueiras, Eduardo
  • García Domingo, Beatriz
  • Aguilera Tejero, Jorge
  • Gueymard, Christian A.
Archivo Digital UPM
Publication Artículo científico (JournalArticle)

Solar irradiation and PV module temperature dispersion at a large-scale PV plant

  • García, Miguel
  • Marroyo, Luis
  • Lorenzo Pigueiras, Eduardo
  • Marcos Álvarez, Javier
  • Pérez, Miguel
Archivo Digital UPM
Publication Artículo científico (JournalArticle)

Implementation and validation of a self-consumption maximization energy management strategy in a Vanadium Redox Flow BIPV demonstrator

  • Fialho, Luis
  • Fartaria, Tomás
  • Narvarte Fernández, Luis|||0000-0002-6289-7605
  • Collares Pereira, Manuel
Archivo Digital UPM
Publication Artículo científico (JournalArticle)

On the relation between battery size and PV power ramp rate limitation

  • Makibar Puente, Aitor|||0000-0002-3536-896X
  • Narvarte Fernández, Luis|||0000-0002-6289-7605
  • Lorenzo Pigueiras, Eduardo|||0000-0001-7449-1824
Archivo Digital UPM
Publication Artículo científico (JournalArticle)

Uncertainties on the outdoor characterization of PV modules and the calibration of reference modules

  • Carrillo Salinas, José Manuel
  • Martínez Moreno, Francisco|||0000-0002-8427-9445
  • Lorenzo Navarro, Celena|||0000-0003-1608-3245
  • Lorenzo Pigueiras, Eduardo|||0000-0001-7449-1824
Archivo Digital UPM
Publication Artículo científico (JournalArticle)

A simple model for the prediction of yearly energy yields for grid-connected PV systems starting from monthly meteorological data

  • Muñoz Cano, Javier
  • Perpiñan Lamigueiro, Oscar|||0000-0002-4134-7196
Archivo Digital UPM
Publication Artículo científico (JournalArticle)

In-the-field PID related experiences

  • Martínez Moreno, Francisco|||0000-0002-8427-9445
  • Figueiredo, Gilberto
  • Lorenzo Pigueiras, Eduardo|||0000-0001-7449-1824
Archivo Digital UPM
Publication Artículo científico (JournalArticle)

Comparative study of PV power forecast using parametric and nonparametric PV models

  • Almeida, Marcelo Pinho
  • Muñoz, Mikel
  • Parra, Iñigo de la
  • Perpiñan Lamigueiro, Oscar|||0000-0002-4134-7196
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publication Artículo científico (JournalArticle)

Control strategies to smooth short-term power fluctuations in large photovoltaic plants using battery storage systems

  • Marcos Álvarez, Javier
  • Parra Laita, Íñigo de la
  • García Solano, Miguel
  • Marroyo Palomo, Luis
The variations in irradiance produced by changes in cloud cover can cause rapid fluctuations in the power generated by large photovoltaic (PV) plants. As the PV power share in the grid increases, such fluctuations may adversely affect power quality and reliability. Thus, energy storage systems (ESS) are necessary in order to smooth power fluctuations below the maximum allowable. This article first proposes a new control strategy (step-control), to improve the results in relation to two state-of-the-art strategies, ramp-rate control and moving average. It also presents a method to quantify the storage capacity requirements according to the three different smoothing strategies and for different PV plant sizes. Finally, simulations shows that, although the moving-average (MA) strategy requires the smallest capacity, it presents more losses (2–3 times more) and produces a much higher number of cycles over the ESS (around 10 times more), making it unsuitable with storage technologies as lithium-ion. The step-control shown as a better option in scenery with exigent ramp restrictions (around 2%/min) and distributed generation against the ramp-rate control in all ESS key aspects: 20% less of capacity, up to 30% less of losses and a 40% less of ageing. All the simulations were based on real PV production data, taken every 5 s in the course of one year (2012) from a number of systems with power outputs ranging from 550 kW to 40 MW., This work has been financed by the Seventh Framework Programme of the European Commission with the Project Photovoltaic Cost Reduction, Reliability, Operational Performance, Prediction and Simulation (PVCROPS—Grant Agreement No. 308468).
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publication Artículo científico (JournalArticle)

Fuzzy logic-based energy management system design for residential grid-connected microgrids

  • Arcos Avilés, Diego
  • Pascual Miqueleiz, Julio María
  • Marroyo Palomo, Luis
  • Sanchis Gúrpide, Pablo
  • Guinjoan Gispert, Francesc
This paper presents the design of a low complexity fuzzy logic controller of only 25-rules to be embedded in an energy management system for a residential grid-connected microgrid including renewable energy sources and storage capability. The system assumes that neither the renewable generation nor the load demand is controllable. The main goal of the design is to minimize the grid power profile fluctuations while keeping the battery state of charge within secure limits. Instead of using forecasting-based methods, the proposed approach use both the microgrid energy rate-of-change and the battery state of charge to increase, decrease, or maintain the power delivered/absorbed by the mains. The controller design parameters (membership functions and rule-base) are adjusted to optimize a pre-defined set of quality criteria of the microgrid behavior. A comparison with other proposals seeking the same goal is presented at simulation level, whereas the features of the proposed design are experimentally tested on a real residential microgrid implemented at the Public University of Navarre., This work was supported in part by the Secretaría Nacional de Educación Superior, Ciencia, Tecnología e Innovación SENESCYT and the Instituto de Fomento al Talento Humano del Ecuador under Grant 2013-AR2Q4081; in part by the Government of Navarra and the European Regional Development Fund under the Microgrids in Navarra: Design, Development, and Implementation Project; in part by the Spanish Ministry of Economy and Competitiveness under Grant DPI2013-42853-R; in part by the European Union under Project FP7-308468; in part by PVCROPS—Photovoltaic Cost Reduction, Reliability, Operational Performance, Prediction, and Simulation under Grant RUE CSD2009-00046; in part by the Consolider-Ingenio 2010 Programme; in part by the Spanish Ministry of Science and Innovation; and in part by the Spanish Ministry of Economy and Knowledge under Grant DPI2013-41224-P and Grant DPI2012-31580. Paper no. TSG-00712-2015.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publication Artículo científico (JournalArticle)

Implementation and control of a residential electrothermal microgrid based on renewable energies, a hybrid storage system and demand side management

  • Pascual Miqueleiz, Julio María
  • Sanchis Gúrpide, Pablo
  • Marroyo Palomo, Luis
This paper proposes an energy management strategy for a residential electrothermal microgrid, based on renewable energy sources. While grid connected, it makes use of a hybrid electrothermal storage system, formed by a battery and a hot water tank along with an electrical water heater as a controllable load, which make possible the energy management within the microgrid. The microgrid emulates the operation of a single family home with domestic hot water (DHW) consumption, a heating, ventilation and air conditioning (HVAC) system as well as the typical electric loads. An energy management strategy has been designed which optimizes the power exchanged with the grid profile in terms of peaks and fluctuations, in applications with high penetration levels of renewables. The proposed energy management strategy has been evaluated and validated experimentally in a full scale residential microgrid built in our Renewable Energy Laboratory, by means of continuous operation under real conditions. The results show that the combination of electric and thermal storage systems with controllable loads is a promising technology that could maximize the penetration level of renewable energies in the electric system., This work was partially funded by the Government of Navarra and the FEDER funds under project “Microgrids in Navarra: design, development and implementation” and by the Spanish Ministry of Economy and Competitiveness under grant DPI2010-21671-C02-01, as well as by the European Union under the project FP7-308468, “PVCROPS-Photovoltaic Cost reduction, reliability, operational performance, prediction and simulation”.