Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Characterization of scintillator materials for fast-ion loss detectors in nuclear fusion reactors

  • Jiménez-Ramos, M. C.
  • García López, J.
  • García-Muñoz, M.
  • Rodríguez-Ramos, M.
  • Carmona Gázquez, M.
  • Zurro, B.
Trabajo presentado a la: "21st International Conference on Ion Beam Analysis", celebrada en Seattle (US) del 23 al 28 de junio de 2013., In fusion plasma reactors, fast ion generated by heating systems and fusion born particles must be well confined. The presence of magnetohydrodynamic (MHD) instabilities can lead to a significant loss of these ions, which may reduce drastically the heating efficiency and may cause damage to plasma facing components in the vacuum vessel. In order to understand the physics underlying the fast ion loss mechanism, scintillator based detectors have been installed in several fusion devices. In this work we present the absolute photon yield and its degradation with ion fluence in terms of the number of photons emitted per incident ion of several scintillators thin coatings: SrGa2S 4:Eu2+ (TG-Green), Y3Al5O 12:Ce3+ (P46) and Y2O3:Eu 3+ (P56) when irradiated with light ions of different masses (deuterium ions, protons and α-particles) at energies between approximately 575 keV and 3 MeV. The photon yield will be discussed in terms of the energy deposited by the particles into the scintillator. For that, the actual composition and thickness of the thin layers were determined by Rutherford Backscattering Spectrometry (RBS). © 2014 Elsevier B.V. All rights reserved., This research was supported in part by the Spanish Ministry of Economy and Competitiveness (RYC-2011-09152 and ENE2012-31087), the Marie Curie FP7 Integration Grant, PCIG11-GA-2012-321455, within the 7th EU Framework Program and the European Fusion Development Agreement (EFDA WP11, 12 and 13)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Conceptual design of the ITER fast-ion loss detector

  • García-Muñoz, M.
  • García López, J.
  • González-Martín, Javier
  • Jiménez-Ramos, M. C.
  • Rodríguez-Ramos, M.
  • Sanchís Sánchez, Lucía
et al., A conceptual design of a reciprocating fast-ion loss detector for ITER has been developed and is presented here. Fast-ion orbit simulations in a 3D magnetic equilibrium and up-to-date first wall have been carried out to revise the measurement requirements for the lost alpha monitor in ITER. In agreement with recent observations, the simulations presented here suggest that a pitch-angle resolution of ∼5° might be necessary to identify the loss mechanisms. Synthetic measurements including realistic lost alpha-particle as well as neutron and gamma fluxes predict scintillator signal-to-noise levels measurable with standard light acquisition systems with the detector aperture at ∼11 cm outside of the diagnostic first wall. At measurement position, heat load on detector head is comparable to that in present devices., This research was supported in part by the Spanish Ministry of Economy and Competitiveness (Grant Nos. RYC2011-09152, FIS2015-69362-P, and ENE2012- 31087) and the Marie Curie FP7 Integration Grant (No. PCIG11-GA2012-321455)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Temperature response of several scintillator materials to light ions

  • Rodríguez-Ramos, M.
  • Jiménez-Ramos, M. C.
  • García-Muñoz, M.
  • García López, J.
Ion beam induced luminescence has been used to study the response of scintillator screens of YO:Eu (P56) and SrGaS:Eu (TG-Green) when irradiated with light ions (protons, deuterium and helium particles). The absolute efficiency of the samples has been studied as a function of the ion energy (with energies up to 3.5 MeV), the beam current and the operating temperature. The evolution of the scintillator yield with ion fluence has been carried out for all the scintillators to estimate radiation damage. Finally, measurements of the decay time of these materials using a system of pulsed beam accelerated particles have been done. Among the screens under study, the TG-Green is the best suited material, in terms of absolute efficiency, temporal response and degradation with ion dose, for fast-ion loss detectors in fusion devices., This research was supported in part by the Spanish Ministry of Economy and Competitiveness through the projects RYC-2011-09152, ENE2012-31087 and FIS2015-69362-P (MINECO/FEDER, UE) and the Marie Curie FP7 Integration Grant (No. PCIG11-GA-2012-321455) and the V Plan propio de la Universidad de Sevilla (VPPI-US)., Peer Reviewed