Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 7
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Real-time 3D reconstruction of non-rigid shapes with a single moving camera

  • Agudo Martínez, Antonio
  • Moreno-Noguer, Francesc
  • Calvo, Begoña
  • Montiel, J. M. M.
This paper describes a real-time sequential method to simultaneously recover the camera motion and the 3D shape of deformable objects from a calibrated monocular video. For this purpose, we consider the Navier-Cauchy equations used in 3D linear elasticity and solved by finite elements, to model the time-varying shape per frame. These equations are embedded in an extended Kalman filter, resulting in sequential Bayesian estimation approach. We represent the shape, with unknown material properties, as a combination of elastic elements whose nodal points correspond to salient points in the image. The global rigidity of the shape is encoded by a stiffness matrix, computed after assembling each of these elements. With this piecewise model, we can linearly relate the 3D displacements with the 3D acting forces that cause the object deformation, assumed to be normally distributed. While standard finite-element-method techniques require imposing boundary conditions to solve the resulting linear system, in this work we eliminate this requirement by modeling the compliance matrix with a generalized pseudoinverse that enforces a pre-fixed rank. Our framework also ensures surface continuity without the need for a post-processing step to stitch all the piecewise reconstructions into a global smooth shape. We present experimental results using both synthetic and real videos for different scenarios ranging from isometric to elastic deformations. We also show the consistency of the estimation with respect to 3D ground truth data, include several experiments assessing robustness against artifacts and finally, provide an experimental validation of our performance in real time at frame rate for small maps., This work has been partially supported by the Spanish Ministry of Science and Innovation under projects RT-SLAM DPI2015-67275-P, RobInstruct TIN2014-58178-R and Keratocono DPI2014-54981-R; by the FP7-SME-2013 606634 PopCorn project from the European Union FP7; by the ERA-net CHISTERA project VISEN PCIN-2013-047 and I-DRESS PCIN-2015-147; and by a scholarship FPU12/04886 awarded by the Spanish MECD., Peer reviewed
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

Real-time 3D reconstruction of non-rigid shapes with a single moving camera

  • Agudo Martínez, Antonio|||0000-0001-6845-4998
  • Moreno-Noguer, Francesc
  • Calvo, Begoña
  • Martinez Montiel, José Maria
© <year>. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/, This paper describes a real-time sequential method to simultaneously recover the camera motion and the 3D shape of deformable objects from a calibrated monocular video. For this purpose, we consider the Navier-Cauchy equations used in 3D linear elasticity and solved by finite elements, to model the time-varying shape per frame. These equations are embedded in an extended Kalman filter, resulting in sequential Bayesian estimation approach. We represent the shape, with unknown material properties, as a combination of elastic elements whose nodal points correspond to salient points in the image. The global rigidity of the shape is encoded by a stiffness matrix, computed after assembling each of these elements. With this piecewise model, we can linearly relate the 3D displacements with the 3D acting forces that cause the object deformation, assumed to be normally distributed. While standard finite-element-method techniques require imposing boundary conditions to solve the resulting linear system, in this work we eliminate this requirement by modeling the compliance matrix with a generalized pseudoinverse that enforces a pre-fixed rank. Our framework also ensures surface continuity without the need for a post-processing step to stitch all the piecewise reconstructions into a global smooth shape. We present experimental results using both synthetic and real videos for different scenarios ranging from isometric to elastic deformations. We also show the consistency of the estimation with respect to 3D ground truth data, include several experiments assessing robustness against artifacts and finally, provide an experimental validation of our performance in real time at frame rate for small maps, Peer Reviewed
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Coupled Biomechanical Response of the Cornea Assessed by Non-Contact Tonometry. A Simulation Study

  • Ariza-Gracia, Miguel A.
  • Zurita, Jesus F.
  • Piñero, David P.
  • Rodriguez Matas, Jose F.
  • Calvo, Begoña
The mechanical response of the cornea subjected to a non-contact air-jet tonometry diagnostic test represents an interplay between its geometry, the corneal material behavior and the loading. The objective is to study this interplay to better understand and interpret the results obtained with a non-contact tonometry test. A patient-specific finite element model of a healthy eye, accounting for the load free configuration, was used. The corneal tissue was modeled as an anisotropic hyperelastic material with two preferential directions. Three different sets of parameters within the human experimental range obtained from inflation tests were considered. The influence of the IOP was studied by considering four pressure levels (10–28 mmHg) whereas the influence of corneal thickness was studied by inducing a uniform variation (300–600 microns). A Computer Fluid Dynamics (CFD) air-jet simulation de- termined pressure loading exerted on the anterior corneal surface. The maximum apex displacement showed a linear variation with IOP for all materials examined. On the contrary, the maximum apex displacement followed a cubic relation with corneal thickness. In addition, a significant sensitivity of the apical displacement to the corneal stiffness was also obtained. Explanation to this behavior was found in the fact that the cornea experiences bending when subjected to an air-puff loading, causing the anterior surface to work in compression whereas the posterior surface works in tension. Hence, collagen fibers located at the anterior surface do not contribute to load bearing. Non-contact tonometry devices give useful information that could be misleading since the corneal deformation is the result of the interaction between the mechanical properties, IOP, and geometry. Therefore, a non- contact tonometry test is not sufficient to evaluate their individual contribution and a complete in-vivo characterization would require more than one test to independently determine the membrane and bending corneal behavior.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Use of 2% hydroxypropyl methylcellulose to prevent the corneal swelling during the in vitro mechanical characterization

  • Ortilles, A.
  • Lanchares, E.
  • Cristóbal, J.A.
  • Calvo, B.
The aim of this study was to assess the use of 2% HPMC during in vitro uniaxial tensile tests, with corneal strips immediately obtained or after storing the eyes for 24¿h in 0.9% NaCl solution at 4¿¿. The purpose was to establish a standardized procedure to prevent phenomena which can modify the mechanical properties of the tissue. Rabbit eyes were divided into four groups. Group A had seven eyes that were preserved in NaCl solution for 24¿h before testing. Group B had seven eyes that were immediately tested. In both groups, to prevent both swelling and dehydration, 2% hydroxypropyl methylcellulose (2% HPMC) was applied. Group C had seven eyes that were preserved in NaCl solution for 24¿h before testing. Group D had seven eyes that were immediately tested. In both groups, HPMC was not applied. Regarding the mechanical response, groups with HPMC showed similar Cauchy stress–stretch curves and there were no statistically significant differences at 5%, 10% and 15% strain between them, which mean that both showed similar mechanical behavior. The same result was obtained between groups without HPMC. However, for coupled groups with and without HPMC, statistically significant differences at 10% and 15% strain were observed. On the other hand, when grouped by storage time, statistically significant differences were found between groups that had eyes preserved for 24¿h with and without HPMC, respectively, as well as between groups immediately tested with and without HPMC, respectively, at 15% strain. Nevertheless, if coupled groups were considered, between groups that were preserved for 24¿h in NaCl before testing and groups that were immediately tested, no statistically significant differences were obtained. In addition, the Cauchy stress–stretch curves of groups without HPMC showed a decreasing slope of the linear part (strain¿>¿8%) of the graph during the experiment. In summary, the use of HPMC during the handling of the tissue from excision to testing seems to prevent both swelling and dehydration.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Automatized patient-specific methodology for numerical determination of biomechanical corneal response

  • Ariza-Gracia, M.Á.
  • Zurita, J.
  • Piñero, D.P.
  • Calvo, B.
  • Rodríguez-Matas, J.F.
This work presents a novel methodology for building a three-dimensional patient-specific eyeball model suitable for performing a fully automatic finite element (FE) analysis of the corneal biomechanics. The reconstruction algorithm fits and smooths the patient’s corneal surfaces obtained in clinic with corneal topographers and creates an FE mesh for the simulation. The patient’s corneal elevation and pachymetry data is kept where available, to account for all corneal geometric features (central corneal thickness–CCT and curvature). Subsequently, an iterative free-stress algorithm including a fiber’s pull-back is applied to incorporate the pre-stress field to the model. A convergence analysis of the mesh and a sensitivity analysis of the parameters involved in the numerical response is also addressed to determine the most influential features of the FE model. As a final step, the methodology is applied on the simulation of a general non-commercial non-contact tonometry diagnostic test over a large set of 130 patients—53 healthy, 63 keratoconic (KTC) and 14 post-LASIK surgery eyes. Results show the influence of the CCT, intraocular pressure (IOP) and fibers (87%) on the numerical corneal displacement (Formula presented.) the good agreement of the (Formula presented.) with clinical results, and the importance of considering the corneal pre-stress in the FE analysis. The potential and flexibility of the methodology can help improve understanding of the eye biomechanics, to help to plan surgeries, or to interpret the results of new diagnosis tools (i.e., non-contact tonometers).
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Real-time 3D reconstruction of non-rigid shapes with a single moving camera

  • Agudo Martínez, Antonio
  • Moreno-Noguer, Francesc
  • Calvo, Begoña
  • Martinez Montiel, José Maria
© <year>. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/, This paper describes a real-time sequential method to simultaneously recover the camera motion and the 3D shape of deformable objects from a calibrated monocular video. For this purpose, we consider the Navier-Cauchy equations used in 3D linear elasticity and solved by finite elements, to model the time-varying shape per frame. These equations are embedded in an extended Kalman filter, resulting in sequential Bayesian estimation approach. We represent the shape, with unknown material properties, as a combination of elastic elements whose nodal points correspond to salient points in the image. The global rigidity of the shape is encoded by a stiffness matrix, computed after assembling each of these elements. With this piecewise model, we can linearly relate the 3D displacements with the 3D acting forces that cause the object deformation, assumed to be normally distributed. While standard finite-element-method techniques require imposing boundary conditions to solve the resulting linear system, in this work we eliminate this requirement by modeling the compliance matrix with a generalized pseudoinverse that enforces a pre-fixed rank. Our framework also ensures surface continuity without the need for a post-processing step to stitch all the piecewise reconstructions into a global smooth shape. We present experimental results using both synthetic and real videos for different scenarios ranging from isometric to elastic deformations. We also show the consistency of the estimation with respect to 3D ground truth data, include several experiments assessing robustness against artifacts and finally, provide an experimental validation of our performance in real time at frame rate for small maps, Peer Reviewed, Postprint (author's final draft)
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publication Artículo científico (JournalArticle)

Coupled biomechanical response of the cornea assessed by non-contact tonometry. A simulation study

  • Ariza Gracia, Miguel A.
  • Zurita Gabasa, Jesús
  • Piñero, David P.
  • Rodríguez Matas, José F.
  • Calvo, Begoña
The mechanical response of the cornea subjected to a non-contact air-jet tonometry diagnostic test represents an interplay between its geometry, the corneal material behavior and the loading. The objective is to study this interplay to better understand and interpret the results obtained with a non-contact tonometry test. A patient-specific finite element model of a healthy eye, accounting for the load free configuration, was used. The corneal tissue was modeled as an anisotropic hyperelastic material with two preferential directions. Three different sets of parameters within the human experimental range obtained from inflation tests were considered. The influence of the IOP was studied by considering four pressure levels (10–28 mmHg) whereas the influence of corneal thickness was studied by inducing a uniform variation (300–600 microns). A Computer Fluid Dynamics (CFD) air-jet simulation determined pressure loading exerted on the anterior corneal surface. The maximum apex displacement showed a linear variation with IOP for all materials examined. On the contrary, the maximum apex displacement followed a cubic relation with corneal thickness. In addition, a significant sensitivity of the apical displacement to the corneal stiffness was also obtained. Explanation to this behavior was found in the fact that the cornea experiences bending when subjected to an air-puff loading, causing the anterior surface to work in compression whereas the posterior surface works in tension. Hence, collagen fibers located at the anterior surface do not contribute to load bearing. Non-contact tonometry devices give useful information that could be misleading since the corneal deformation is the result of the interaction between the mechanical properties, IOP, and geometry. Therefore, a noncontact tonometry test is not sufficient to evaluate their individual contribution and a complete in-vivo characterization would require more than one test to independently determine the membrane and bending corneal behavior., The research leading these results has received funding from the European Union’s Seven Framework Program managed by REA Research Executive agency under Grant Agreement n° FP7-SME-2013 606634 and the Spanish Ministry of Economy and Competitiveness (DPI2011-27939-C02-01).