Feasibility study of a proton irradiation facility for fadiobiological measurements at an 18 MeV Cyclotron

  • Baratto-Roldan, Anna
  • Jiménez-Ramos, M. C.
  • Battaglia, M. C.
  • García López, J.
  • Gallardo, María Isabel
  • Cortés-Giraldo, Miguel Antonio
  • Espino, J. M.
A feasibility study of an experimental setup for the irradiation of biological samples at the cyclotron facility installed at the National Centre of Accelerators (Seville, Spain) is presented. This cyclotron, which counts on an external beam line for interdisciplinary research purposes, produces an 18 MeV proton beam, which is suitable for the irradiation of mono-layer cultures for the measurement of proton cell damages and Relative Biological Effectiveness (RBE) at energies below the beam nominal value. Measurements of this kind are of interest for proton therapy, since the variation of proton RBE at the distal edge of the Bragg curve may have implications in clinical proton therapy treatments. In the following, the characteristics of the beam line and the solutions implemented for the irradiation of biological samples are described. When dealing with the irradiation of cell cultures, low beam intensities and broad homogeneous irradiation fields are required, in order to assure that all the cells receive the same dose with a suitable dose rate. At the cyclotron, these constraints have been achieved by completely defocusing the beam, intercepting the beam path with tungsten scattering foils and varying the exit-window-to-sample distance. The properties of the proton beam thus obtained have been analysed and compared with Monte Carlo simulations. The results of this comparison, as well as the experimental measurement of the lateral dose profiles expected at the position of samples are presented. Meaningful dose rates of about 2–3 Gy/min have been obtained. Homogeneous lateral dose profiles, with maximum deviations of 5%, have been measured at a distance of approximately 50 cm in air from the exit window, placing a tungsten scattering foil of 200 µm in the beam path., This project has received funding from the European Union’s Horizon 2020 research and innovation programme under the Marie Sklodowska-Curie Grant No. 675265, OMA—Optimization of Medical Accelerators, from the Spanish Ministry of Economy and Competitiveness under Grant No. FPA2016-77689-C2-1-R, and from the Council for Innovation, Science and Commerce of the Andalusian Government under Grant No. P12-FQM-1605., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Preparation of a radiobiology beam line at the 18 MeV proton cyclotron facility at CNA

  • Baratto-Roldan, Anna
  • Jiménez-Ramos, M. C.
  • Jimeno, Sonia
  • Huertas Sánchez, Pablo
  • García López, J.
  • Gallardo, María Isabel
  • Cortés-Giraldo, Miguel Antonio
  • Espino, J. M.
Proton therapy has gained interest in recent years due to its excellent clinical outcomes. However, the lack of accurate biological data, especially in the Bragg peak region of clinical beams, makes it difficult to implement biophysically optimized treatment plans in clinical practice. In this context, low energy proton accelerator facilities provide the perfect environment to collect good radiobiological data, as they can produce high LET beams with narrow energy distributions. This study presents the radiobiology beam line that has been designed at the 18 MeV proton cyclotron facility at the National Centre of Accelerators (CNA, Seville, Spain), to perform irradiations of mono-layer cell cultures. To ensure that all the cells receive the same dose with a suitable dose rate, low beam intensities and broad and homogeneous beam profiles are necessary. To do so, at the CNA an unfocused beam has been used, broadened with a 500 μm thick aluminium scattering foil. Homogeneous dose profiles, with deviations lower than 10% have been obtained over a circular surface of 35 mm diameter for an incident average energy of 12.8 MeV. Further, a Monte Carlo simulation of the beam line has been developed with Geant4, and benchmarked towards experimental measurements, with differences generally below 1%. Once validated, the code has been used, together with an ionization chamber, for dosimetry studies, to characterize the beam and monitor the dose. Finally, cultures of Human Bone Osteosarcoma cells (U2OS) have been successfully irradiated at the radiobiology beam line, investigating the effects of radiation in terms of DNA damage induction., This project has received funding from the European Union’s Horizon 2020 research and innovation programme under the Marie Sklodowska-Curie Grant No. 675265, OMA–Optimization of Medical Accelerators; from the Spanish Plan for Scientific and Technical Research and Innovation under Grant No. FPA2016-77689-C2-1-R, Grant No. RTI2018-098117-B-C21 and Grant No. SAF2016-74855-P; and from the Council for Innovation, Science and Commerce of the Andalusian Government under Grant No. P12-FQM-1605. CABIMER is supported by the regional Government of Andalucia (Junta de Andalucía)., Peer reviewed