Skip to main content

DISEÑO DE UNA PLATAFORMA BASADA EN MATRICES DE SENSORES DE CUARZO DE ALTA RESOLUCION PARA HTS (HIGH-THROUGHPUT SCREENING) DE RESIDUOS EN MIELES

AGL2013-48646-R

•
Funding agency name Ministerio de Economía y Competitividad
Funding agency acronym MINECO
Program Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Call Proyectos I+D+i Retos de Investigación
Call year 2013
State Plan 2013-2016 Plan Estatal de Investigación Científica y Técnica y de Innovación
Management unit Secretaría de Estado de Educación, Formación Profesional y Universidades
Beneficiary centre UNIVERSITAT POLITÈCNICA DE VALÈNCIA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 7
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Routine quality control in honey packaging companies as a key to guarantee consumer safety. The case of the presence of sulfonamides analyzed with LC-MS-MS

  • Juan-Borras, María del Sol|||0000-0003-4774-9484
  • Doménech Antich, Eva Mª|||0000-0003-3560-6355
  • Escriche Roberto, Mª Isabel|||0000-0003-0180-0360
  • Periche Santamaría, Angela
[EN] One of the main challenges in the Horizon 2020 framework is to ensure sufficient food and feed, while monitoring safety throughout the food chain. In this context, the objective of this paper was to evaluate the efficacy of the routine quality control that honey companies carry out on raw batches (before entering the industrial packaging process) considering the presence of sulfonamides. A total of 279 honey samples were analyzed in this study: 178 raw honey samples were taken on reception in different companies, and 101 samples (from the same industries) were purchased locally. The validation of the methodology applied (LCeMS/MS) before analyzing the samples, confirm the reliability of the results obtained. All the purchased samples were found to be negative for sulfonamides, however, in 9 raw samples sulfathiazole (6 samples) and sulfadiazine (3 samples) were found, which represents 3.4% and 1.7% of the 178 raw samples analyzed, respectively. Therefore, if monitoring is carried out routinely at reception, risk can be decreased to a negligible level. The results confirm that using a suitable analytical methodology and implementing an appropriate routine quality control on reception is totally effective to avoid the presence of sulfonamides in the commercialized product, thereby ensuring consumer safety. © 2014 Elsevier Ltd. All rights reserved., This study forms part of a project funded by the Ministerio de Educacion y Ciencia of Spain (Programa Estatal de Investigacion, Desarrollo e Innovacion Orientada a los retos de la sociedad; project number AGL2013-48646-R), for which the authors are grateful.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

High Fundamental Frequency (HFF) Monolithic Quartz Crystal Microbalance with Dissipation Array for the Simultaneous Detection of Pesticides and Antibiotics in Complex Food

  • Calero-Alcarria, María Del Señor
  • García, María
  • Montoya, Ángel
  • FERNÁNDEZ DÍAZ, ROMÁN|||0000-0002-8883-4653
  • Juan-Borras, María del Sol|||0000-0003-4774-9484
  • Escriche Roberto, Mª Isabel|||0000-0003-0180-0360
  • Arnau Vives, Antonio|||0000-0002-5709-1690
  • Jiménez Jiménez, Yolanda|||0000-0003-4835-9007
[EN] As in the case of the food industry in general, there is a global concern about safety and quality in complex food matrices, such as honey, which is driving the demand for fast, sensitive and affordable analytical techniques across the honey-packaging industry. Although excellent techniques such as liquid chromatography-tandem mass spectrometry (LC-MS/MS) are available, these are located in centralized laboratories and are still lacking in speed, simplicity and cost-effectiveness. Here, a new approach is presented where a competitive immunoassay is combined with a novel High Fundamental Frequency Quartz Crystal Microbalance with Dissipation (HFF-QCMD) array biosensor for the simultaneous detection of antibiotics and pesticides in honey. Concretely, thiabendazole and sulfathiazole residues were monitored in spiked honey samples. Results revealed that HFF-QCMD arrays provide a complementary and reliable tool to LC-MS/MS for the analysis of contaminants in these kinds of complex matrices, while avoiding elaborate sample pre-treatment. The good sensitivity achieved (I50 values in the 70¿720 µg/kg range) and the short analysis time (60 min for 24 individual assays), together with the ability for multiple analyte detection (24 sensor array) and its cost-effectiveness, pave the way for the implementation of a fast on-line, in situ routine control of potentially hazardous chemical residues in honey., This work was supported by Ministerio de Economía, Industria y Competitividad de España-Agencia Estatal de Investigación with FEDER (Fondo Europeo de Desarrollo Regional) funds under Grants AGL2016-77702-R and AGL2013-48646-R. M. Calero is the recipient of the doctoral fellowship BES-2017-080246 from the Ministerio de Economía, Industria y Competitividad de España.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Mixture-risk-assessment of pesticide residues in retail polyfloral honey

  • Juan-Borras, María del Sol|||0000-0003-4774-9484
  • Doménech Antich, Eva Mª|||0000-0003-3560-6355
  • Escriche Roberto, Mª Isabel|||0000-0003-0180-0360
[EN] The presence of even tiny quantities of pesticide residues in honey, a traditional healthy product, is a matter of concern for producers, packers and consumers. This paper aims to quantify pesticides in retail brands of polyfloral honey, and to calculate the mixture risk assessment of honey for consumers according to the results obtained from the analyzed samples. A LC-MS/MS multi-residue method was developed and validated for 13 compounds: 11 pesticides (chlorfenvinphos, coumaphos, tau-fluvalinate, amitraz, which are very common in veterinary treatments, and imidacloprid, acetamiprid, simazine, cyproconazole, tebuconazole, chlorpiryphos-methyl, chlorpiryphos, widely used in agricultural practices), and 2 metabolites of amitraz (2,4-DMA and 2,4-DMF). Results showed that the samples contained pesticide residues at different concentrations; however, the MRL in honey for each of the 11 pesticides was never exceeded. The most common were amitraz (from 1 to 50 ¿Ýg/kg) present in 100% of the samples, and coumaphos (up to 14 ¿Ýg/kg) in 63%. The hazard index (HI) for adults was less than 0.002 in all cases, a long way from 1, the value established as the limit of acceptability. Therefore, commercial honey does not represent any significant risk to health. However, considering that residue levels should be present ¡§as low as reasonably achievable¡¿ it is deemed necessary to make an effort to reduce their presence by appropriate agricultural and, above all, beekeeping practices due to acaridae treatments., This study forms part of a project funded by the Ministerio de Economia y Competitividad of Spain (Programa Estatal de Investigacion Desarrollo e Innovacion Orientada a los retos de la sociedad; Project number AGL2013-48646-R), for which the authors are grateful.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

A novel bismuth-based lead-free piezoelectric transducer immunosensor for carbaryl quantification

  • Fernández-Benavides, D.A.
  • Arias de Fuentes, O.
  • Montoya, Ángel
  • Muñoz-Saldaña, J.
  • Cervera-Chiner, Lourdes|||0000-0002-6895-4957
  • Jiménez Jiménez, Yolanda|||0000-0003-4835-9007
[EN] A novel BNT-BKT-BT piezoelectric ceramic immunosensor, tested for quantification of the pesticide carbaryl is here presented. The measuring format was based on a competitive immunoassay of immobilized conjugate using monoclonal antibodies (MAbs) as specific immunoreagent. The immunosensor is able to detect concentrations of the analyte from one and up to three orders of magnitude below the reported values of high- and low- frequency quartz crystal commercial resonators (HFF-QCM and QCM), respectively. Furthermore, the minimum content of quantified carbaryl is 0.11 ¿g L-1, which is clearly lower than reported values of any commercial quartz-based biosensors. Such measurement characteristics are only possible due to the high electromechanical coupling factor (kt) of the Bi-based piezoelectric ceramic, approaching the commercial QCM, HFF-QCM and ELISA techniques and strongly enhancing the sensitivity of the immunoassay., This project received support from CONACYT (Grants Nr. CB-220734, FC 2015-2-896, LN 292686 and 293429). This work has been carried out at CENAPROT and LIDTRA national laboratories as well as at Center for Research and Innovation in Bioengineering (Ci2B) of Universitat Politecnica de Valencia.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

High Fundamental Frequency Quartz Crystal Microbalance (HFF-QCMD) Immunosensor for detection of sulfathiazole in honey

  • Cervera-Chiner, Lourdes|||0000-0002-6895-4957
  • Jiménez Jiménez, Yolanda|||0000-0003-4835-9007
  • Juan-Borras, María del Sol|||0000-0003-4774-9484
  • Arnau Vives, Antonio|||0000-0002-5709-1690
  • Escriche Roberto, Mª Isabel|||0000-0003-0180-0360
  • Montoya, Ángel
  • Pascual, Nuria
[EN] In this study, a piezoelectric immunosensor based on High Fundamental Frequency Quartz Crystal Microbalance (HFF-QCMD) technology was developed for detection of sulfathiazole in honey. The biorecognition was based on a competitive immunoassay in the conjugate-coated format, using monoclonal antibodies as specific im-munoreagents. The quantification of sulfathiazole was performed by building the corresponding calibration standard curve in diluted honey (1/140). Due to the competitive nature of the immunoassay, the standard curve showed a sigmoidal pattern with limits of detection (LOD) and quantification (LOQ) of 0.10 ¿g/kg and 2 ¿g/kg honey, respectively. The LOD reached by this immunosensor is 40¿50 times lower than those reported by other techniques for antibiotic detection. Moreover, this method requires minimum honey pre-treatment, making it faster and simpler than other methods. This immunosensor meets the precision and accuracy requirements established by SANCO guidelines, when sulfathiazole concentration in honey is not lower than 10 ¿g/kg. These findings could be the basis for reaching enough reliability for lower concentrations. Therefore, HFF-QCMD immunosensors can be considered a feasible alternative to current techniques for rapid and highly sensitive determination of sulfathiazole in honey with minimum sample preparation., The Spanish Ministry of Economy and Competitiveness, with FEDER-funds, has financially supported this work through the AGL 2013-48646-R project. Furthermore, authors are grateful for financial support from the European Social Fund and the Generalitat Valenciana for the PhD grant (Ayudas para la contratación de personal investigador en formación de carácter predoctoral) to Lourdes Cervera Chiner (ACIF/2016/132). The authors would also like to thank the Universitat Politècnica de València for the support provided for contracting Marisol Juan Borrás in the frame of PAID-10-17 (Ayuda para la contratación de acceso al Sistema Español de Ciencia, Tecnología e Innovación en Estructuras de Investigación).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Detection of DDT and carbaryl pesticides in honey by means of immunosensors based on high fundamental frequency quartz crystal microbalance (HFF-QCM)

  • Cervera-Chiner, Lourdes|||0000-0002-6895-4957
  • Arnau Vives, Antonio|||0000-0002-5709-1690
  • Jiménez Jiménez, Yolanda|||0000-0003-4835-9007
  • March, Carmen
  • Montoya, Ángel
[EN] BACKGROUND: In recent years there has been a concern about the presence of pesticides in honey because residues of DDT and carbaryl were found in honey samples. Traditional techniques, such as chromatography, reach the required limits of detection (LOD) but are not suitable for in situ implementation in the honey-packaging industry due to their high cost and the need for highly quali¿ed staff for routine operation. Biosensors offer simplicity, low cost, and easy handling for analytical purposes in food applications. RESULTS: Piezoelectric immunosensors based on high fundamental frequency quartz crystal microbalance (HFF-QCM) have been developed for the detection of carbaryl and DDT in honey. Biorecognition was based on competitive immunoassays in the conjugate-coated format, using monoclonal antibodies as speci¿c immunoreagents. The assay LODs attained by the HFF-QCM immunosensors were 0.05 ~gL¿1 for carbaryl and 0.24 ~gL¿1 for DDT, reaching a similar level of detectability to that of the usual reference techniques. The practical LODs in honey samples were 8 ~gkg¿1 for carbaryl and 24 ~gkg¿1 for DDT. The immunosensors¿ analytical performance allow the detection of these pesticides in honey at EU regulatory levels with good accuracy (recovery percentages ranging from 94% to 130% within the working range of each pesticide standard curve) and precision (coef¿cients of variation in the 9¿36% range). CONCLUSION: The proposed immunosensor is a promising analytical tool that could be implemented for quality control in the honey packaging industry, to simplify and to reduce the cost of the routine pesticide analysis in this appreciated natural food., This research was funded by the Spanish Ministry of Economy and Competitiveness with FEDER funds (AGL Project 2013-48646-R). L.C.C. was the recipient of a PhD fellowship from the European Social Fund and the Generalitat Valenciana (ACIF / 2016/132)
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

High Fundamental Frequency Quartz Crystal Microbalance (HFF-QCM) immunosensor for pesticide detection in honey

  • Cervera-Chiner, Lourdes|||0000-0002-6895-4957
  • Juan-Borras, María del Sol|||0000-0003-4774-9484
  • Arnau Vives, Antonio|||0000-0002-5709-1690
  • Escriche Roberto, Mª Isabel|||0000-0003-0180-0360
  • Jiménez Jiménez, Yolanda|||0000-0003-4835-9007
  • March, Carmen
  • Montoya, Ángel
[EN] Quantification of chemical residues in honey is a market requirement to ensure consumer safety. The most common method used to analyze these compounds is the LC/MS/MS methodology, which requires highly qualified technicians and a tedious pre-treatment of the sample. The honey-packaging industry needs cheaper and faster alternatives for routine control. HFF-QCM (High Fundamental Frequency Quartz Crystal Microbalance) sensors are becoming a good option due to their high sensitivity, fast detection and low cost, while avoiding complex sample pre-treatment. The HFF-QCM technology is based on piezoelectric sensors with frequencies in the range from several tenths of MHz to hundreds of MHz. In this work a 100 MHz HFF-QCM sensor was used in a monoclonal antibody-based competitive immunoassay for specific bio-recognition of carbaryl pesticide as testing contaminant. The work intends to validate the use of HFF-QCM technology, in comparison with liquid chromatography-tandem mass spectrometry (LC-MS/MS) technique, for the detection of contaminants in honey. For this purpose, the validation criteria required by SANCO 12571/2013 guidance document were considered. The precision and accuracy (recovery) of both methods were determined by comparison of 5 replicates at 4 different concentrations (from 0 to 100 ¿g/kg) using the same honey matrix. HFF-QCM technology showed good accuracy, with recovery percentages always between 110 and 120%. As regards to precision, HFF-QCM coefficients of variation (CV) were around 10% higher than those recommended by GC SANCO 12571/2013. HFF-QCM limits of detection (LOD) and quantification (LOQ) were in the same order of magnitude as those for LC-MS/MS, which allows the analysis of carbaryl residues in honey under the established maximum residue limits (MRL), without sample pre-treatment. These results show that biosensors based on HFF-QCM technology has become a serious alternative to the traditional analytical techniques for food quality and safety applications., The authors are grateful for financial support from the Ministry of Economy and Competitiveness of Spain under the project AGL2013-48646-R. We also want to thank “Generalitat Valenciana” for the financial support to hire research personnel through the grant “Ayudas para la contratación de personal investigador en formación de carácter predoctoral” to carry out this research (DOC Num.7615/15.09.2015).