Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 20
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

HEV Occurrence in Waste and Drinking Water Treatment Plants

  • Cuevas-Ferrando, Enric
  • Randazzo, Walter
  • Pérez-Cataluña, Alba
  • Sánchez, Gloria
[EN] Hepatitis E virus (HEV), particularly zoonotic genotype 3, is present in environmental waters worldwide, especially in industrialized countries. Thus, monitoring the presence of HEV in wastewater treatment plants (WWTPs) is an emerging topic due to the importance of reusing water on a global level. Given the limited data, this study aimed to monitor the occurrence of HEV in influent and effluent water in waste- and drinking-water treatment plants (WWTPs and DWTPs). To this end, different procedures to concentrate HEV in influent and effluent water from WWTPs and DWTPs were initially evaluated. The evaluated procedures resulted in average HEV recoveries of 15.2, 19.9, and 16.9% in influent, effluent, and drinking water samples, respectively, with detection limits ranging from 103 to 104 international units (IU)/L. Then, a one-year pilot study was performed to evaluate the performance of the selected concentration method coupled with three RT-qPCR assays in influent and effluent water samples from four different WWTPs. HEV prevalence in influent water varied based on both the RT-qPCR assay and WWTP, while HEV was not detected in effluent water samples. In addition, HEV prevalence using only RT-qPCR3 was evaluated in influent (n = 62) and effluent samples (n = 52) from four WWTPs as well as influent (n = 28) and effluent (n = 28) waters from two DWTPs. The present study demonstrated that HEV circulated in the Valencian region at around 30.65% with average concentrations of 6.3 × 103 IU/L. HEV was only detected in influent wastewater samples, effluent samples from WWTPs and influent and effluent samples from DWTPs were negative. However, given that the infective dose in waterborne epidemics settings is not yet known and the low sensibility of the assay, unfortunately, no direct conclusion could be achieved on the risk assessment of environmental contamination., This work was financially supported by the projects GV/2019/156 funded by Generalitat Valenciana and the VIRIDIANA project AGL2017-82909 (AEI/FEDER, UE) supported by Spanish Ministry of Science, Innovation and Universities (MICINN). WR was supported by a postdoctoral fellowship (APOSTD/2018/150) and EC-F by an APOTI grant (APOTIP/2018/007) both funded by the Generalitat Valenciana. EC-F is recipient of a predoctoral contract from the MICINN, Call 2018. The authors acknowledge support of the publication fee by the CSIC Open Access Publication Support Initiative through its Unit of Information Resources for Research (URICI).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Discrimination of non-infectious SARS-CoV-2 particles from fomites by viability RT-qPCR

  • Cuevas-Ferrando, Enric
  • Girón-Guzmán, Inés
  • Falcó, Irene
  • Pérez-Cataluña, Alba
  • Díaz-Reolid, Azahara
  • Aznar, Rosa
  • Randazzo, Walter
  • Sánchez, Gloria
[EN] The ongoing coronavirus 2019 (COVID-19) pandemic constitutes a concerning global threat to public health and economy. In the midst of this pandemic scenario, the role of environment-to-human COVID-19 spread is still a matter of debate because mixed results have been reported concerning SARS-CoV-2 stability on high-touch surfaces in real-life scenarios. Up to now, no alternative and accessible procedures for cell culture have been applied to evaluate SARS-CoV-2 infectivity on fomites. Several strategies based on viral capsid integrity have latterly been developed using viability markers to selectively remove false-positive qPCR signals resulting from free nucleic acids and damaged viruses. These have finally allowed an estimation of viral infectivity. The present study aims to provide a rapid molecular-based protocol for detection and quantification of viable SARS-CoV-2 from fomites based on the discrimination of non-infectious SARS-CoV-2 particles by platinum chloride (IV) (PtCl4) viability RT-qPCR. An initial assessment compared two different swabbing procedures to recover inactivated SARS-CoV-2 particles from fomites coupled with two RNA extraction methods. Procedures were validated with human (E229) and porcine (PEDV) coronavirus surrogates, and compared with inactivated SARS-CoV-2 suspensions on glass, steel and plastic surfaces. The viability RT-qPCR efficiently removed the PCR amplification signals from heat and gamma-irradiated inactivated SARS-CoV-2 suspensions that had been collected from specified surfaces. This study proposes a rapid viability RT-qPCR that discriminates non-infectious SARS-CoV-2 particles on surfaces thus helping researchers to better understand the risk of contracting COVID-19 through contact with fomites and to develop more efficient epidemiological measures., The study was supported by EIT-Food (COVID-19 BAEMitup) , CSIC (202070E101) , Generalitat Valenciana (Covid_19-SCI) , MICINN co-founded by AEI/FEDER, UE (AGL2017-82909) , and MICINN/AEI (PID2019-105509RJ-I00) . EC-F is recipient of a predoctoral contract from the MICINN, Call 2018. IGG is recipient of a Collaboration Grant 2020-2021 from the MEFP.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Spatial and temporal distribution of SARS-CoV-2 diversity circulating in wastewater.

  • Pérez-Cataluña, Alba
  • Chiner-Oms, Álvaro
  • Cuevas-Ferrando, Enric
  • Díaz-Reolid, Azahara
  • Falcó, Irene
  • Randazzo, Walter
  • Girón-Guzmán, Inés
  • Allende, Ana
  • Bracho, María A.
  • Comas, Iñaki
  • Sánchez, Gloria
[EN] Wastewater-based epidemiology (WBE) has proven to be an effective tool for epidemiological surveillance of SARS-CoV-2 during the current COVID-19 pandemic. Furthermore, combining WBE together with highthroughput sequencing techniques can be useful for the analysis of SARS-CoV-2 viral diversity present in a given sample. The present study focuses on the genomic analysis of SARS-CoV-2 in 76 sewage samples collected during the three epidemiological waves that occurred in Spain from 14 wastewater treatment plants distributed throughout the country. The results obtained demonstrate that the metagenomic analysis of SARS-CoV-2 in wastewater allows the detection of mutations that define the B.1.1.7 lineage and the ability of the technique to anticipate the detection of certain mutations before they are detected in clinical samples. The study proves the usefulness of sewage sequencing to track Variants of Concern that can complement clinical testing to help in decision-making and in the analysis of the evolution of the pandemic., This study was supported by projects "VIRIDIANA" (AGL2017-82909/AEI/FEDER, UE) and MCEC-WATER (PID2020-116789RB-C42/AEI/FEDER, UE) funded by Spanish Ministry of Science, Innovation and Universities; CSIC (202070E101), Generalitat Valenciana (Covid_19-SCI), the European Union Next Generation EU (SGL2103034), the COVID-19 wastewater surveillance project (VATar COVID19), funded by the Spanish Ministry for the Ecological Transition and the Demographic Challenge and the Spanish Ministry of Health, the Instituto de Salud Carlos III (Ref COV20/00140), ERC TB-RECONNECT 101001038 funded by The European Union Next Generation EU and the Lagoon project (PROMETEO/2021/044). EC-F is recipient of a predoctoral contract from the MICINN, Call 2018 and AP-C was supported by a postdoctoral fellowship (APOSTD/21/292). We acknowledge NILSA, FACSA, and MITECO for authorizing the sampling. The authors thank Agustin Garrido Fern ' andez, and Andrea Lopez de Mota for their technical support.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Monitoring Human Viral Pathogens Reveals Potential Hazard for Treated Wastewater Discharge or Reuse

  • Cuevas-Ferrando, Enric
  • Pérez-Cataluña, Alba
  • Falcó, Irene
  • Randazzo, Walter
  • Sánchez, Gloria
[EN] Wastewater discharge to the environment or its reuse after sanitization poses a concern for public health given the risk of transmission of human viral diseases. However, estimating the viral infectivity along the wastewater cycle presents technical challenges and still remains underexplored. Recently, human-associated crAssphage has been investigated to serve as viral pathogen indicator to monitor fecal impacted water bodies, even though its assessment as biomarker for infectious enteric viruses has not been explored yet. To this end, the occurrence of potentially infectious norovirus genogroup I (GI), norovirus GII, hepatitis A virus (HAV), rotavirus A (RV), and human astrovirus (HAstV) along with crAssphage was investigated in influent and effluent water sampled in four wastewater treatment plants (WWTPs) over 1 year by a PMAxx-based capsid integrity RT-qPCR assay. Moreover, influent and effluent samples of a selected WWTP were additionally assayed by an in situ capture RT-qPCR assay (ISC-RT-qPCR) as estimate for viral infectivity in alternative to PMAxx-RT-qPCR. Overall, our results showed lower viral occurrence and concentration assessed by ISC-RT-qPCR than PMAxx-RT-qPCR. Occurrence of potentially infectious enteric virus was estimated by PMAxx-RT-qPCR as 88-94% in influent and 46-67% in effluent wastewaters with mean titers ranging from 4.77 to 5.89, and from 3.86 to 4.97 log10 GC/L, with the exception of HAV that was sporadically detected. All samples tested positive for crAssphage at concentration ranging from 7.41 to 9.99 log10 GC/L in influent and from 4.56 to 6.96 log10 GC/L in effluent wastewater, showing higher mean concentration than targeted enteric viruses. Data obtained by PMAxx-RT-qPCR showed that crAssphage strongly correlated with norovirus GII (¿ = 0.67, p < 0.05) and weakly with HAstV and RV (¿ = 0.25-0.30, p < 0.05) in influent samples. In effluent wastewater, weak (¿ = 0.27-0.38, p < 0.05) to moderate (¿ = 0.47-0.48, p < 0.05) correlations between crAssphage and targeted viruses were observed. Overall, these results corroborate crAssphage as an indicator for fecal contamination in wastewater but a poor marker for either viral occurrence and viral integrity/infectivity. Despite the viral load reductions detected in effluent compared to influent wastewaters, the estimates of viral infectivity based on viability molecular methods might pose a concern for (re)-using of treated water., This research was supported by the VIRIDIANA (AGL2017-82909, AEI/FEDER, UE) and PREVISION (PID2019-105509RJ-I00, AEI/FEDER, UE) projects funded by the Spanish Ministry of Science, Innovation and Universities, and the 2018CPS10 project funded by the Center for Produce Safety. AP-C was recipient of a postdoctoral grant from Generalitat Valenciana (APOSTD/2021/292). EC-F was recipient of a predoctoral contract from the MICINN, Call 2018. The funding sources had no rule in the study design, data collection, analysis of data, writing, or in the decision to publish.
Minerva. Repositorio Institucional de la Universidad de Santiago de Compostela
Publication Artículo científico (JournalArticle)

Monitoring Emergence of the SARS-CoV‑2 B.1.1.7 Variant through the Spanish National SARS-CoV‑2 Wastewater Surveillance System (VATar COVID-19)

  • Carcereny, Albert
  • López Romalde, Jesús
  • Lois, Marta
  • Polo Montero, David
  • Guix, Susana
Since its first identification in the United Kingdom in late 2020, the highly transmissible B.1.1.7 variant of SARS-CoV- 2 has become dominant in several countries raising great concern. We developed a duplex real-time RT-qPCR assay to detect, discriminate, and quantitate SARS-CoV-2 variants containing one of its mutation signatures, the ΔHV69/70 deletion, and used it to trace the community circulation of the B.1.1.7 variant in Spain through the Spanish National SARS-CoV-2 Wastewater Surveillance System (VATar COVID-19). The B.1.1.7 variant was detected earlier than clinical epidemiological reporting by the local authorities, first in the southern city of Máĺaga (Andalucía) in week 20_52 (year_week), and multiple introductions during Christmas holidays were inferred in different parts of the country. Wastewater-based B.1.1.7 tracking showed a good correlation with clinical data and provided information at the local level. Data from wastewater treatment plants, which reached B.1.1.7 prevalences higher than 90% for ≥2 consecutive weeks showed that 8.1 ± 2.0 weeks were required for B.1.1.7 to become dominant. The study highlights the applicability of RT-qPCR-based strategies to track specific mutations of variants of concern as soon as they are identified by clinical sequencing and their integration into existing wastewater surveillance programs, as a cost-effective approach to complement clinical testing during the COVID-19 pandemic.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Viability RT-qPCR to distinguish between HEV and HAV with intact and altered capsids

  • Randazzo, Walter
  • Vasquez García, A.
  • Aznar, Rosa
  • Sánchez Moragas, Gloria
The hepatitis E virus (HEV) is an emerging pathogen showing a considerable increase in the number of reported cases in Europe mainly related to the ingestion of contaminated food. As with other relevant viral foodborne pathogens, real-time reverse transcriptase polymerase chain reaction (RT-qPCR) is the gold standard for HEV detection in clinical, food, and environmental samples, but these procedures cannot discriminate between inactivated and potentially infectious viruses. Thus, the aim of this study was to develop a viability PCR method to discriminate between native, heat-, and high-pressure processing (HPP)-treated HEV using the hepatitis A virus (HAV) as a cultivable surrogate. To this end, different concentrations of viability markers (PMAxx and platinum chloride, PtCl) were screened firstly on purified viral RNA using different RT-qPCR assays. Reductions of HEV RNA signals of > 17.5, > 15.0, and > 15.5 quantification cycles (Cq) were reported for PtCl and 1.6, 2.9, and 8.4 Cq for PMAxx, clearly indicating a better performance of PtCl than PMAxx irrespective of the RT-qPCR assay used. The most efficient viability pretreatment (500 μM PtCl incubated at 5°C for 30 min) was then assessed on native, heat-, and HPP-treated HEV suspension. The optimized viability RT-qPCR discriminated successfully between native, heat-, and HPP-treated HEV, to different extents depending on the experimental conditions. In particular, approximately 2-log10 reduction was reported by PtCl-RT-qPCR at both 72 and 95°C compared to the control. Additionally, both viability pretreatments were tested for HPP-treated HAV without success, while PtCl-RT-qPCR completely eliminated (> 5.6-log10 reduction) the RT-qPCR signals of HPP-treated HEV. Although this viability procedure may still overestimate infectivity, the PtCl pretreatment represents progress to better interpreting the quantification of intact HEV, and it could be included in molecular procedures used to quantify enteric viruses in food and environmental samples., This work was supported by the Spanish Ministry of Economy and Competitiveness (MINECO) (AGL2017-82909) and the Spanish National Institute for Agriculture and Food Research and Technology (INIA) co-financed by the European Social Fund (Project RTA2014-00024-C03). Financial support has been co-sponsored by the European Regional Development Fund (FEDER). This work was carried out during a scholarship supported by the Doctoral Program Sandwich Exterior (PDSE), process number 88881.132189/2016-01, financed by CAPES - Brazilian Federal Agency for Postgraduate Support and Evaluation at the Brazilian Ministry of Education., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Epidemiological Surveillance of Norovirus and Rotavirus in Sewage (2016–2017) in Valencia (Spain)

  • Santiso-Bellón, Cristina
  • Randazzo, Walter
  • Pérez-Cataluña, Alba
  • Vila-Vicent, Susana
  • Gozalbo-Rovira, Roberto
  • Muñoz, Carlos
  • Buesa, Javier
  • Sánchez Moragas, Gloria
  • Rodríguez Díaz, Jesús
© 2020 by the authors., The aim of the present study was to perform the molecular epidemiology of rotaviruses and noroviruses detected in sewage samples from a large wastewater facility from the city of Valencia, Spain. A total of 46 sewage samples were collected over a one-year period (September 2016 to September 2017). Norovirus and rotavirus were detected and quantified by RT-qPCR, genotyped by semi-nested RT-PCR and further characterized by sequencing and phylogenetic analyses. Noroviruses and rotaviruses were widely distributed in sewage samples (69.6% for norovirus GI, 76.0% norovirus GII, and 71.7% rotaviruses) and viral loads varied from 4.33 to 5.75 log PCRU/L for norovirus GI, 4.69 to 6.95 log PCRU/L for norovirus GII, and 4.08 to 6.92 log PCRU/L for rotavirus. Overall, 87.5% (28/32) of GI noroviruses could not be genotyped, 6.25% (2/32) of the samples contained GI.2 genotype, and another 6.25% (2/32) were positive for GI.4 genotype. The most common genotype of GII noroviruses was GII.2 (40%, 14/35), followed by GII.6 (8.6%, 3/35) and GII.17 (5.7%, 2/35) while the remaining GII strains could not be typed (45.7%, 16/35). Rotavirus VP4 genotype P[8] was the only one found in 19 out of 33 rotavirus-positive samples (57.7%). G2 was the most prevalent rotavirus VP7 genotype (15.2%, 5/33) followed by G3, G9, and G12, with two positive samples for each genotype (6.1%, 2/33). In one sample both G1 and G2 genotypes were detected simultaneously (3%). The results presented here show that the surveillance of noroviruses and rotaviruses in sewage is useful for the study of their transmission in the population and their molecular epidemiology., This work was supported by Spanish Government (Ministerio de Economía y Competitividad) grants AGL2017-84165-C2-2-R, RYC-2013-12442, and AGL2017-82909-R (AEI/FEDER, UE) funded by Spanish Ministry of Science, Innovation and Universities. This work was also founded by the Generalitat Valenciana and the UE FEDER program IDIFER/2018/056. CSB is the recipient of a predoctoral grant FPI from the Spanish Government RE2018-083315. RGR and WR are supported by postdoctoral fellowships from Valencian Government (APOST/2017/037 and APOSTD/2018/150)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

SARS-CoV-2 RNA in wastewater anticipated COVID-19 occurrence in a low prevalence area

  • Randazzo, Walter
  • Truchado, Pilar
  • Cuevas Ferrando, Enric
  • Simón Andreu, Pedro J.
  • Allende, Ana
  • Sánchez Moragas, Gloria
Preprint disponible en http://hdl.handle.net/10261/209125, Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has caused more than 200,000 reported COVID-19 cases in Spain resulting in more than 20,800 deaths as of April 21, 2020. Faecal shedding of SARS-CoV-2 RNA from COVID-19 patients has extensively been reported. Therefore, we investigated the occurrence of SARS-CoV-2 RNA in six wastewater treatments plants (WWTPs) serving the major municipalities within the Region of Murcia (Spain), the area with the lowest COVID-19 prevalence within Iberian Peninsula. Firstly, an aluminum hydroxide adsorption-precipitation concentration method was validated using a porcine coronavirus (Porcine Epidemic Diarrhea Virus, PEDV) and mengovirus (MgV). The procedure resulted in average recoveries of 10 ± 3.5% and 10 ± 2.1% in influent water (n = 2) and 3.3 ± 1.6% and 6.2 ± 1.0% in effluent water (n = 2) samples for PEDV and MgV, respectively. Then, the method was used to monitor the occurrence of SARS-CoV-2 from March 12 to April 14, 2020 in influent, secondary and tertiary effluent water samples. By using the real-time RT-PCR (RT-qPCR) Diagnostic Panel validated by US CDC that targets three regions of the virus nucleocapsid (N) gene, we estimated quantification of SARS-CoV-2 RNA titers in untreated wastewater waters of 5.4 ± 0.2 log10 genomic copies/L on average. Two secondary water samples resulted positive (2 out of 18) and all tertiary water samples tested as negative (0 out 12). This environmental surveillance data were compared to declared COVID-19 cases at municipality level, revealing that members of the community were shedding SARS-CoV-2 RNA in their stool even before the first cases were reported by local or national authorities in many of the cities where wastewaters have been sampled. The detection of SARS-CoV-2 in wastewater in early stages of the spread of COVID-19 highlights the relevance of this strategy as an early indicator of the infection within a specific population. At this point, this environmental surveillance could be implemented by municipalities right away as a tool, designed to help authorities to coordinate the exit strategy to gradually lift its coronavirus lockdown., The study was funded by the projects 20180705 of ESAMUR, 202070E101 of CSIC and “VIRIDIANA” AGL2017-82909 (AEI/FEDER, UE) of MICIU. WR is supported by APOSTD/2018/150 postdoctoral fellowship of Generalitat Valenciana. EC-F is recipient of a predoctoral contract from the MICINN, Call 2018. PT is holder of the RYC2018- 025510-I Ramón y Cajal contract from the MICIU., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Assessment of ISO Method 15216 to Quantify Hepatitis E Virus in Bottled Water

  • Cuevas Ferrando, Enric
  • Martínez-Murcia, Antonio
  • Pérez-Cataluña, Alba
  • Sánchez Moragas, Gloria
  • Randazzo, Walter
© 2020 by the authors., Hepatitis E virus (HEV) is one of the causative agents of water-borne human viral hepatitis and considered in Europe an emerging zoonotic pathogen. Analysis of bottled water through a standard method validated for HEV can contribute towards the risk management of this hazard. Putting some recent reports by the European Food Safety Authority in place, this study aimed to assess the performance of the concentration and extraction procedures described in ISO 15216-1:2017 for norovirus and hepatitis A virus on HEV detection. Following the ISO recommendation, the bottled water samples were spiked using serially diluted HEV fecal suspensions together with mengovirus as process control and concentrated by filtration via positively charged nylon membranes. In order to extract viral RNA from the resulting concentrates, two different methods were compared in this study: The one recommended in the ISO norm, NucliSens® MiniMag® system (NS), and an alternative commercially available kit NucleoSpin®RNA virus kit (MN). Finally, three reverse transcription quantitative PCR (RT-qPCR) assays were used to quantify HEV titers. The evaluated procedures resulted in average HEV recoveries of 14.08 ± 4.90% and 3.58 ± 0.30% for the MN and NS methods, respectively. The limit of detection (LoD95%) was 1.25 × 104 IU/L for both extraction methods combined with the three RT-qPCR assays tested, with the exception of NS extraction coupled with RT-qPCR1 that showed a LoD95% of 4.26 × 103 IU/L. The method characteristics generated in this study support the limited suitability of the ISO 15216-1:2017 concentration procedure coupled with the evaluated RT-qPCR assays for detecting HEV in bottled water., This research was funded by Generalitat Valenciana, project number GV/2019/156, and by Spanish Ministry of Science, Innovation and Universities (MICINN), project number AGL2017-82909. WR was supported by APOSTD/2018/150 postdoctoral grant and ECF by MICINN, Call 2018 predoctoral contract., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Metropolitan wastewater analysis for COVID-19 epidemiological surveillance

  • Randazzo, Walter
  • Cuevas Ferrando, Enric
  • Sanjuán, Rafael
  • Domingo-Calap, Pilar
  • Sánchez Moragas, Gloria
The COVID-19 disease, caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), is a rapidly emerging pandemic which has enforced extreme containment measures worldwide. In the absence of a vaccine or efficient treatment, cost-effective epidemiological surveillance strategies are urgently needed. Here, we have used RT-qPCR for SARS-CoV-2 detection in a series of longitudinal metropolitan wastewaters samples collected from February to April 2020, during the earliest stages of the epidemic in the Region of Valencia, Spain. We were able to consistently detect SARS-CoV-2 RNA in samples taken in late February, when communicated cases in that region were only incipient. We also find that the wastewater viral RNA context increased rapidly and anticipated the subsequent ascent in the number of declared cases. Our results strongly suggest that the virus was undergoing community transmission earlier than previously believed, and suggest that wastewater analysis could be sensitive and cost-effective strategy for COVID-19 epidemiological surveillance. Routine implementation of this surveillance tool would significantly improve our preparedness against new or re-occurring viral outbreaks., This research was funded by CSIC 202070E101 grant, 210152 project of Valencian Innovation Agency/GV, and AGL2017-82909 (AEI/FEDER, UE) funded by Spanish Ministry of Science, Innovation and Universities to G.S., ERC Consolidator Grant 724519-Vis-à-Vis to R.S. and FONDO-COVID19 COV20/00210 funded by Instituto de Salud Carlos III to P.D-C. W.R. was supported by APOSTD/2018/150 postdoctoral fellowship, and E.C–F. was supported by a predoctoral contract from the MICINN, Call 2018., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Recovering coronavirus from large volumes of water

  • Cuevas Ferrando, Enric
  • Pérez-Cataluña, Alba
  • Allende, Ana
  • Guix, Susana
  • Randazzo, Walter
  • Sánchez Moragas, Gloria
The need for monitoring tools to better control the ongoing coronavirus disease (COVID-19) pandemic is extremely urgent and the contamination of water resources by excreted viral particles poses alarming questions to be answered. As a first step to overcome technical limitations in monitoring SARS-CoV-2 along the water cycle, we assessed the analytical performance of a dead end hollow fiber ultrafiltration coupled to different options for secondary concentrations to concentrate viral particles from large volume of spiked tap water, seawater and surface water together with two quantitative RT-qPCR detection kits. Spiking the porcine epidemic diarrhea virus (PEDV), an enveloped virus surrogate for SARS-CoV-2, together with the mengovirus, we demonstrated that PEG-precipitation and SENS-kit better recovered PEDV (13.10 ± 0.66%) from tap water, while centrifugal filtration resulted the best option to recover mengovirus regardless of the detection kit used. No statistical significant differences were found when comparing high (10,000 ×g) and low (3500 ×g) centrifugation speeds for the secondary PEG- based concentration of spiked seawater, while considerable inhibition was observed for both viruses detected by NoInh-kit assay. Similarly, the co-concentration of PCR inhibitors and viral particles was observed in surface waters detected with either SENS-kit or NoInh-kit and RNA dilution was needed to achieve acceptable recoveries at the expenses of the overall sensitivity of the method. These methodologies represent suitable options to investigate SARS-CoV-2 occurrence in different water resources and allow to conduct on site sampling of large volume of water., The study was funded by grants from CSIC (202070E101), Generalitat Valenciana (Covid_19-SCI), and MICIU co-founded by AEI/FEDER, UE (AGL2017-82909). EC-F is recipient of a predoctoral contract from the MICINN, Call 2018. WR is holder of the APOSTD/2018/150 postdoctoral contract from Generalitat Valenciana., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Comparing analytical methods to detect SARS-CoV-2 in wastewater

  • Pérez-Cataluña, Alba
  • Cuevas Ferrando, Enric
  • Randazzo, Walter
  • Falcó, Irene
  • Allende, Ana
  • Sánchez Moragas, Gloria
Wastewater based epidemiology (WBE) has emerged as a reliable strategy to assess the coronavirus disease 2019 (COVID-19) pandemic. Recent publications suggest that SARS-CoV-2 detection in wastewater is technically feasible; however, many different protocols are available and most of the methods applied have not been properly validated. To this end, different procedures to concentrate and extract inactivated SARS-CoV-2 and surrogates were initially evaluated. Urban wastewater seeded with gamma-irradiated SARS-CoV-2, porcine epidemic diarrhea virus (PEDV), and mengovirus (MgV) was used to test the concentration efficiency of an aluminum-based adsorption-precipitation method and a polyethylene glycol (PEG) precipitation protocol. Moreover, two different RNA extraction methods were compared in this study: a commercial manual spin column centrifugation kit and an automated protocol based on magnetic silica beads. Overall, the evaluated concentration methods did not impact the recovery of gamma-irradiated SARS-CoV-2 nor MgV, while extraction methods showed significant differences for PEDV. Mean recovery rates of 42.9 ± 9.5%, 27.5 ± 14.3% and 9.0 ± 2.2% were obtained for gamma-irradiated SARS-CoV-2, PEDV and MgV, respectively. Limits of detection (LoD95%) for five genomic SARS-CoV-2 targets (N1, N2, gene E, IP2 and IP4) ranged from 1.56 log genome equivalents (ge)/mL (N1) to 2.22 log ge/mL (IP4) when automated system was used; while values ranging between 2.08 (N1) and 2.34 (E) log ge/mL were observed when using column-based extraction method. Different targets were also evaluated in naturally contaminated wastewater samples with 91.2%, 85.3%, 70.6%, 79.4% and 73.5% positivity, for N1, N2, E, IP2 and IP4, respectively. Our benchmarked comparison study suggests that the aluminum precipitation method coupled with the automated nucleic extraction represents a method of acceptable sensitivity to provide readily results of interest for SARS-CoV-2 WBE surveillance., The study was funded by grants from CSIC (202070E101), Generalitat Valenciana (Covid_19-SCI), MICINN co-founded by AEI/FEDER, UE (AGL2017-82909), and MICINN/AEI (PID2019-105509RJ-I00). EC-F is recipient of a predoctoral contract from the MICINN, Call 2018. WR is holder of the APOSTD/2018/150 postdoctoral contract from Generalitat Valenciana., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Bias of library preparation for virome characterization in untreated and treated wastewaters

  • Pérez-Cataluña, Alba
  • Cuevas Ferrando, Enric
  • Randazzo, Walter
  • Sánchez Moragas, Gloria
The use of metagenomics for virome characterization and its implementation for wastewater analyses, including wastewater-based epidemiology, has increased in the last years. However, the lack of standardized methods can led to highly different results. The aim of this work was to analyze virome profiles in upstream and downstream wastewater samples collected from four wastewater treatment plants (WWTPs) using two different library preparation kits. Viral particles were enriched from wastewater concentrates using a filtration and nuclease digestion procedure prior to total nucleic acid (NA) extraction. Sequencing was performed using the ScriptSeq v2 RNA-Seq (LS) and the NEBNext Ultra II RNA (NB) library preparation kits. Cleaned reads and contigs were annotated using a curated in-house database composed by reads assigned to viruses at NCBI. Significant differences in viral families and in the ratio of detection were shown between the two library kits used. The use of LS library showed Virgaviridae, Microviridae and Siphoviridae as the most abundant families; while Ackermannviridae and Helleviridae were highly represented within the NB library. Additionally, the two sequencing libraries produced outcomes that differed in the detection of viral indicators. These results highlighted the importance of library selection for studying viruses in untreated and treated wastewater. Our results underline the need for further studies to elucidate the influence of sequencing procedures in virome profiles in wastewater matrices in order to improve the knowledge of the virome in the water environment., This study was supported by the “VIRIDIANA” project AGL2017-82909 (AEI/FEDER, UE) funded by Spanish Ministry of Science, Innovation and Universities, CPS project 2018CPS10 from the Center for Produce Safety Grant Agreement, and the APOTI grant (APOTIP/2018/007) from the Generalitat Valenciana. WR was supported by a postdoctoral fellowship from Generalitat Valenciana (APOSTD/2018/150). EC-F is recipient of a predoctoral contract from the MICINN, Call 2018., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Monitoring Emergence of the SARS-CoV-2 B.1.1.7 Variant through the Spanish National SARS-CoV-2 Wastewater Surveillance System (VATar COVID-19)

  • Carcereny, Albert
  • Martínez-Velázquez, Adán
  • Bosch, Albert
  • Allende, Ana
  • Truchado, Pilar
  • Cascales, Jenifer
  • Romalde, Jesús L.
  • Lois, Marta
  • Polo, David
  • Sánchez Moragas, Gloria
  • Pérez-Cataluña, Alba
  • Díaz-Reolid, Azahara
  • Antón, Andrés
  • Gregori, Josep
  • García-Cehic, Damir
  • Quer, Josep
  • Palau, Margarita
  • González Ruano, Cristina
  • Pintó, Rosa María
  • Guix, Susana
Since its first identification in the United Kingdom in late 2020, the highly transmissible B.1.1.7 variant of SARS-CoV-2 has become dominant in several countries raising great concern. We developed a duplex real-time RT-qPCR assay to detect, discriminate, and quantitate SARS-CoV-2 variants containing one of its mutation signatures, the ΔHV69/70 deletion, and used it to trace the community circulation of the B.1.1.7 variant in Spain through the Spanish National SARS-CoV-2 Wastewater Surveillance System (VATar COVID-19). The B.1.1.7 variant was detected earlier than clinical epidemiological reporting by the local authorities, first in the southern city of Málaga (Andalucía) in week 20_52 (year_week), and multiple introductions during Christmas holidays were inferred in different parts of the country. Wastewater-based B.1.1.7 tracking showed a good correlation with clinical data and provided information at the local level. Data from wastewater treatment plants, which reached B.1.1.7 prevalences higher than 90% for ≥2 consecutive weeks showed that 8.1 ± 2.0 weeks were required for B.1.1.7 to become dominant. The study highlights the applicability of RT-qPCR-based strategies to track specific mutations of variants of concern as soon as they are identified by clinical sequencing and their integration into existing wastewater surveillance programs, as a cost-effective approach to complement clinical testing during the COVID-19 pandemic., This work was partially supported by the COVID-19 wastewater surveillance project (VATar COVID19), funded by the Spanish Ministry for the Ecological Transition and the Demographic Challenge and the Spanish Ministry of Health, grants from CSIC (202070E101) and MICINN cofounded by AEI FEDER, UE (AGL2017-82909), grant ED431C 2018/18 from the Consellería de Educación, Universidade e Formación Profesional, Xunta de Galicia (Spain), Direcció General de Recerca i Innovació en Salut (DGRIS) Catalan Health Ministry Generalitat de Catalunya through Vall d’Hebron Research Institute (VHIR), and Centro para el Desarrollo Tecnológico Industrial (CDTI) from the Spanish Ministry of Economy and Business, grant number IDI-20200297. P.T. is holding a Ramón y Cajal contract from the Ministerio de Ciencia e Innovación. A.M. is holding a predoctoral fellowship FI_SDUR from Generalitat de Catalunya. We gratefully acknowledge all the staff involved in the VATar COVID-19 project, working with sample collection and logistics. The authors are grateful to Promega Corporation (Madison, US) for technical advice and thank Andrea Lopez de Mota for her technical support., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Platinum chloride-based viability RT-qPCR for SARS-CoV-2 detection in complex samples

  • Cuevas Ferrando, Enric
  • Randazzo, Walter
  • Pérez-Cataluña, Alba
  • Falcó, Irene
  • Navarro, David
  • Martin-Latin, Sandra
  • Díaz-Reolid, Azahara
  • Girón-Guzmán, Inés
  • Allende, Ana
  • Sánchez Moragas, Gloria
Isolation, contact tracing and restrictions on social movement are being globally implemented to prevent and control onward spread of SARS-CoV-2, even though the infection risk modelled on RNA detection by RT-qPCR remains biased as viral shedding and infectivity are not discerned. Thus, we aimed to develop a rapid viability RT-qPCR procedure to infer SARS-CoV-2 infectivity in clinical specimens and environmental samples. We screened monoazide dyes and platinum compounds as viability molecular markers on five SARS-CoV-2 RNA targets. A platinum chloride-based viability RT-qPCR was then optimized using genomic RNA, and inactivated SARS-CoV-2 particles inoculated in buffer, stool, and urine. Our results were finally validated in nasopharyngeal swabs from persons who tested positive for COVID-19 and in wastewater samples positive for SARS-CoV-2 RNA. We established a rapid viability RT-qPCR that selectively detects potentially infectious SARS-CoV-2 particles in complex matrices. In particular, the confirmed positivity of nasopharyngeal swabs following the viability procedure suggests their potential infectivity, while the complete prevention of amplification in wastewater indicated either non-infectious particles or free RNA. The viability RT-qPCR approach provides a more accurate ascertainment of the infectious viruses detection and it may complement analyses to foster risk-based investigations for the prevention and control of new or re-occurring outbreaks with a broad application spectrum., The study was supported by CSIC (202070E101), Generalitat Valenciana (Covid_19-SCI), MICINN co-founded by AEI/FEDER, UE (AGL2017-82909), and MICINN/AEI (PID2019-105509RJ-I00). EC-F is recipient of a predoctoral contract from the MICINN, Call 2018. We thank Agustin Garrido Fernández and Andrea Lopez de Mota at IATA-CSIC for providing support in sample processing. We acknowledge Global Omnium S.L., NILSA, Aguas de Malaga, ESAMUR and FACSA for coordinating and managing wastewater sampling., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Spatial and temporal distribution of SARS-CoV-2 diversity circulating in wastewater

  • Pérez-Cataluña, Alba
  • Chiner-Oms, Álvaro
  • Cuevas Ferrando, Enric
  • Díaz-Reolid, Azahara
  • Falcó, Irene
  • Randazzo, Walter
  • Girón-Guzmán, Inés
  • Allende, Ana
  • Bracho, María Alma
  • Comas, Iñaki
  • Sánchez Moragas, Gloria
Wastewater-based epidemiology (WBE) has proven to be an effective tool for epidemiological surveillance of SARS-CoV-2 during the current COVID-19 pandemic. Furthermore, combining WBE together with high-throughput sequencing techniques can be useful for the analysis of SARS-CoV-2 viral diversity present in a given sample. The present study focuses on the genomic analysis of SARS-CoV-2 in 76 sewage samples collected during the three epidemiological waves that occurred in Spain from 14 wastewater treatment plants distributed throughout the country. The results obtained demonstrate that the metagenomic analysis of SARS-CoV-2 in wastewater allows the detection of mutations that define the B.1.1.7 lineage and the ability of the technique to anticipate the detection of certain mutations before they are detected in clinical samples. The study proves the usefulness of sewage sequencing to track Variants of Concern that can complement clinical testing to help in decision-making and in the analysis of the evolution of the pandemic., This study was supported by projects “VIRIDIANA” (AGL2017–82909/ AEI/FEDER, UE) and MCEC-WATER (PID2020–116789RB-C42/ AEI/FEDER, UE) funded by Spanish Ministry of Science, Innovation and Universities; CSIC (202070E101), Generalitat Valenciana (Covid_19-SCI), the European Union – NextGenerationEU (SGL2103034), the COVID-19 wastewater surveillance project (VATar COVID19), funded by the Spanish Ministry for the Ecological Transition and the Demographic Challenge and the Spanish Ministry of Health, the Instituto de Salud Carlos III (Ref COV20/00140), ERC TB-RECONNECT 101001038 funded by The European Union – NextGenerationEU and the Lagoon project (PROMETEO/2021/044). EC-F is recipient of a predoctoral contract from the MICINN, Call 2018 and AP-C was supported by a postdoctoral fellowship (APOSTD/21/292). We acknowledge NILSA, FACSA, and MITECO for authorizing the sampling. The authors thank Agustin Garrido Fernández, and Andrea Lopez de Mota for their technical support., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Monitoring Human Viral Pathogens Reveals Potential Hazard for Treated Wastewater Discharge or Reuse

  • Cuevas Ferrando, Enric
  • Pérez-Cataluña, Alba
  • Falcó, Irene
  • Randazzo, Walter
  • Sánchez Moragas, Gloria
Wastewater discharge to the environment or its reuse after sanitization poses a concern for public health given the risk of transmission of human viral diseases. However, estimating the viral infectivity along the wastewater cycle presents technical challenges and still remains underexplored. Recently, human-associated crAssphage has been investigated to serve as viral pathogen indicator to monitor fecal impacted water bodies, even though its assessment as biomarker for infectious enteric viruses has not been explored yet. To this end, the occurrence of potentially infectious norovirus genogroup I (GI), norovirus GII, hepatitis A virus (HAV), rotavirus A (RV), and human astrovirus (HAstV) along with crAssphage was investigated in influent and effluent water sampled in four wastewater treatment plants (WWTPs) over 1 year by a PMAxx-based capsid integrity RT-qPCR assay. Moreover, influent and effluent samples of a selected WWTP were additionally assayed by an in situ capture RT-qPCR assay (ISC-RT-qPCR) as estimate for viral infectivity in alternative to PMAxx-RT-qPCR. Overall, our results showed lower viral occurrence and concentration assessed by ISC-RT-qPCR than PMAxx-RT-qPCR. Occurrence of potentially infectious enteric virus was estimated by PMAxx-RT-qPCR as 88–94% in influent and 46–67% in effluent wastewaters with mean titers ranging from 4.77 to 5.89, and from 3.86 to 4.97 log10 GC/L, with the exception of HAV that was sporadically detected. All samples tested positive for crAssphage at concentration ranging from 7.41 to 9.99 log10 GC/L in influent and from 4.56 to 6.96 log10 GC/L in effluent wastewater, showing higher mean concentration than targeted enteric viruses. Data obtained by PMAxx-RT-qPCR showed that crAssphage strongly correlated with norovirus GII (ρ = 0.67, p < 0.05) and weakly with HAstV and RV (ρ = 0.25–0.30, p < 0.05) in influent samples. In effluent wastewater, weak (ρ = 0.27–0.38, p < 0.05) to moderate (ρ = 0.47–0.48, p < 0.05) correlations between crAssphage and targeted viruses were observed. Overall, these results corroborate crAssphage as an indicator for fecal contamination in wastewater but a poor marker for either viral occurrence and viral integrity/infectivity. Despite the viral load reductions detected in effluent compared to influent wastewaters, the estimates of viral infectivity based on viability molecular methods might pose a concern for (re)-using of treated water., This research was supported by the “VIRIDIANA” (AGL2017-82909, AEI/FEDER, UE) and “PREVISION” (PID2019-105509RJ-I00, AEI/FEDER, UE) projects funded by the Spanish Ministry of Science, Innovation and Universities, and the 2018CPS10 project funded by the Center for Produce Safety. AP-C was recipient of a postdoctoral grant from Generalitat Valenciana (APOSTD/2021/292). EC-F was recipient of a predoctoral contract from the MICINN, Call 2018., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Sample and library preparation approaches for the analysis of the virome of irrigation water

  • Pérez-Cataluña, Alba
  • Randazzo, Walter
  • Martínez-Blanch, Juan F.
  • Codoñer, Francisco M.
  • Sánchez Moragas, Gloria
The virome (i.e. community of mainly RNA and DNA eukaryotic viruses and bacteriophages) of waters is yet to be extensively explored. In particular, the virome of waters used for irrigation could therefore potentially carry viral pathogens that can contaminate fresh produce. One problem in obtaining viral sequences from irrigation waters is the relatively low amount of virus particles, as well as the presence of human, bacterial and protozoan cells. The present aimed study was to compare different processing, amplification, and sequencing approaches for virome characterization in irrigation waters., This study was supported by the ‘VIRIDIANA’ project AGL2017-82909 (AEI/FEDER, UE) funded by Spanish Ministry of Science, Innovation and Universities; the ‘MAGIC’ project from the Center of Produce Safety (CPS, no. 2018CPS10); and the APOTI grant (APOTIP/2018/007) from the Generalitat Valenciana. IATA-CSIC is a Centre of Excellence Severo Ochoa (CEX2021-001189-S MCIN/AEI/10.13039/501100011033). AP-C is recipient of a postdoctoral grant from the Generalitat Valenciana (APOSTD/2021/292)., With funding from the Spanish government through the ‘Severo Ochoa Centre of Excellence’ accreditation (CEX2021-001189-S)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

An Evaluation of Hepatitis E Virus Molecular Typing Methods

  • Baylis, Sally A
  • Adlhoch, Cornelia
  • Childs, Liam
  • HEV Sequencing Study Group
Hepatitis E virus (HEV) is a major cause of acute viral hepatitis. Better understanding of HEV subtypes involved in hepatitis E infections is essential. Investigation of sources and routes of transmission and the identification of potential clusters/outbreaks rely upon molecular typing of viral strains. A study was carried out to evaluate the ability of laboratories to undertake molecular typing with genotype and subtype determination., This work was supported by a service contract ECD.9621 from European Centre for Disease Prevention and Control. N. Nasheri and J. Harlow, Health Canada internal funds: Internal funding was used to perform viral detection and genotyping. K. Schilling-Loeffler, R. Johne, and V.M. Corman, grant of the German Federal Ministry of Health with regard to a decision of the German Bundestag by the Federal Government (CHED project grant no. ZMVI1-2518FSB705) to institution; G. La Rosa and E. Suffredini, Italian Ministry of Health; I.L.A. Boxman, R.A.M. Dirks, Dutch Food and Consumer Safety Authority; B. Hogema, Sanquin; A. Avellon, Diasorin Iberica, Abbott; G. Sanchez and E.C. Ferrando, MICIU project AGL2017-82909. The study was funded by ECDC with PEI receiving these funds to cover sample preparation, pre-testing and transport costs., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Exploring plant virus diversity in wastewater and reclaimed water through metagenomic analysis

  • Cuevas Ferrando, Enric
  • Sánchez Moragas, Gloria
  • Pérez-Cataluña, Alba
The use of reclaimed water for agricultural activities is being widely employed to address drought and water scarcity. Nevertheless, the disinfection processes do not consistently facilitate the complete removal of all eukaryotic viruses within these reclaimed waters. Consequently, it may pose a risk not only to humans but also to irrigated plants. We analyzed 48 influent and 48 effluent samples from 4 different wastewater treatment plants (WWTPs) by high-throughput sequencing (HTS) to characterize plant-associated virome over a one-year period. Our results showed high levels of plant viruses in both influent and effluent waters. The predominant family identified was Virgaviridae, recognized for its high environmental persistence. Notably, the identification of Tomato Brown Rugose Fruit virus (ToBRFV), classified as a harmful organism by the European Union and subject to strict containment measures to control its spread, highlights the importance of monitoring reclaimed water to mitigate the spread of such viruses into the environment. These findings underscore the need of analyzing reclaimed water from a One Health perspective, ensuring its safety for humans, animals, plants, and the environment alike., This study was supported by the “VIRIDIANA” project AGL2017-82909 (AEI/FEDER, UE) and the IMAGE project PID2020-116789RB-C42, both funded by Spanish Ministry of Science, Innovation and Universities, CPS project 2018CPS10 from the Center for Produce Safety Grant Agreement, and the APOTI grant (APOTIP/2018/007) from the Generalitat Valenciana. EC-F is recipient of a predoctoral contract from the MICINN (PRE2018-083753), Call 2018. AP-C is recipient of the contract Juan de la Cierva – Incorporación (IJC2020-045382-I) which is financed by MCIN/AEI/10.13039/501100011033 and the European Union “NextGenerationEU/PRTR". Finally, authors acknowledge the award of the Spanish government MCIN/AEI to the IATA-CSIC as Center of Excellence Accreditation Severo Ochoa (CEX2021-001189-S/ MCIN/AEI / 10.13039/501100011033)., With funding from the Spanish government through the ‘Severo Ochoa Centre of Excellence’ accreditation (CEX2021-001189-S), Peer reviewed