Neutron measurements with ultra-thin 3D silicon sensors in a radiotherapy treatment room using a Siemens PRIMUS linac

  • Guardiola Salmerón, Consuelo
  • Gómez, Faustino
  • Fleta, Celeste
  • Rodríguez, José Antonio
  • Quirion, David
  • Pellegrini, Giulio
  • Lousa, Arturo
  • Martínez-de-Olcoz, Leyre
  • Pombar, Miguel Angel
  • Lozano Fantoba, Manuel
The accurate detection and dosimetry of neutrons in mixed and pulsed radiation fields is a demanding instrumental issue with great interest both for the industrial and medical communities. In recent studies of neutron contamination around medical linacs, there is a growing concern about the secondary cancer risk for radiotherapy patients undergoing treatment in photon modalities at energies greater than 6 MV. In this work we present a promising alternative to standard detectors with an active method to measure neutrons around a medical linac using a novel ultra-thin silicon detector with 3D electrodes adapted for neutron detection. The active volume of this planar device is only 10 µm thick, allowing a high gamma rejection, which is necessary to discriminate the neutron signal in the radiotherapy peripheral radiation field with a high gamma background. Different tests have been performed in a clinical facility using a Siemens PRIMUS linac at 6 and 15 MV. The results show a good thermal neutron detection efficiency around 2% and a high gamma rejection factor., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Ultra-thin 3D silicon sensors for neutron detection

  • Guardiola Salmerón, Consuelo
  • Fleta, Celeste
  • Pellegrini, Giulio
  • García, Francisco Alejandro
  • Quirion, David
  • Rodríguez, José Antonio
  • Lozano Fantoba, Manuel
We present a novel neutron detector based on an ultra-thin 3D silicon sensor with a sensitive volume only 10 μm thick. This ultra-thin active volume allows a high gamma-ray rejection, a key requirement in order to discriminate the signal coming from the neutrons in a mixed neutron-gamma ray environment. The device upper-side is covered with a novel boron-based compound that detects neutrons by means of the 10B(n,α)7Li nuclear reaction. The performance of test devices has been investigated first with a gamma-ray source to evaluate the gamma-ray rejection factor, and then with an 241AmBe neutron source to assess the neutron-gamma ray discrimination properties. © 2012 IOP Publishing Ltd and Sissa Medialab srl., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

First investigations of a silicon neutron detector with a carborane converter

  • Guardiola Salmerón, Consuelo
  • Fleta, Celeste
  • Quirion, D.
  • Rodríguez, José Antonio
  • Santos Lozano, M. Asunción
  • Teixidor, Francesc
  • Vĩas, Clara
  • Popescu, R.
  • Domingo, C.
  • Amgarou, Khalil
We present a new design of a slow neutron detector, based on silicon detectors with innovative materials acting as conversion layers, plus preliminary results that will be the basis for a more complete study in the near future. The sensitive element of this detector is a Schottky barrier silicon diode covered with o-carborane, a novel boron-based converter material that detects neutrons by means of the 10B(n,α)7Li reaction. This sensor has been simulated with the MCNPX Monte-Carlo software in order to find the optimal converter layer thickness that maximizes the neutron detection efficiency. The simulated maximum efficiency is 2.7% for a 20 μm converter layer of the o-carborane fabricated with pure 10B and of 0.5% for the same compound but made with natural boron material. Moreover, the performance of test devices has been investigated by means of an 241AmBe neutron source and the results have been analyzed with the help of GEANT4 simulations. © 2011 IOP Publishing Ltd and SISSA., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Geant4 and MCNPX simulations of thermal neutron detection with planar silicon detectors

  • Guardiola Salmerón, Consuelo
  • Amgarou, Khalil
  • García, Francisco Alejandro
  • Fleta, Celeste
  • Quirion, David
  • Lozano Fantoba, Manuel
We used Geant4 and MCNPX codes to evaluate the detection efficiency of planar silicon detectors coupled to different Boron-based converters with varied compositions and thicknesses that detect thermal neutrons via the 10B(n,α)7Li nuclear reaction. Few studies about the thermal neutron transport in Geant4 have been reported so far and it is becoming increasingly difficult to ignore its discrepancies with MCNPX in this neutron energy range. In the thermal energy range, Geant4 shows high discrepancies with MCNPX giving a maximum efficiency of about 3.3% in the 10B case whereas that obtained with MCNPX was 5%. Disagreements obtained between both codes in this energy range are analyzed and discussed. © 2011 IOP Publishing Ltd and SISSA., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Monte Carlo simulations of a microstructured silicon detector with high efficiency for thermal neutrons

  • Guardiola Salmerón, Consuelo
  • Fleta, Celeste
  • Amgarou, Khalil
  • Lozano Fantoba, Manuel
In this work we present a design optimization of a high efficiency neutron detector with MCNPX simulations. The detector is based on a silicon structure incorporating a boron-based converter to detect thermal neutrons by means of the 10B(n,α)7Li nuclear reaction. In order to improve the efficiency of planar detectors, limited to 5%, we have designed a perforated detector based on microstructures etched inside the silicon bulk, which would considerably increase this value. Each one of these microstructures is a micro-channel filled with the converter that provides a high surface-volume contact ratio between the converter and the sensitive silicon bulk. The main parameters optimized with the simulations are micro-channel width and depth, width of the silicon wall between micro-channels, and converter density, all comprised within technologically viable ranges. The results show that the detector could achieve up to 50% thermal neutron efficiency for a realistic prototype that can be produced with MEMS fabrication techniques. © 2012 IOP Publishing Ltd and Sissa Medialab srl., Peer reviewed