Skip to main content

ESTUDIO EXPERIMENTAL DE LA APLICACION DE LA TECNOLOGIA DE MEMBRANAS PARA POTENCIAR LA RECUPERACION DE RECURSOS EN LAS EDAR ACTUALES.

CTM2017-86751-C2-1-R

•
Funding agency name Agencia Estatal de Investigación
Funding agency acronym AEI
Program Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Call Proyectos I+D+i Retos de Investigación
Call year 2017
State Plan 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Beneficiary centre UNIVERSITAT DE VALÈNCIA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 14
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Evaluating the Feasibility of Employing Dynamic Membranes for the Direct Filtration of Municipal Wastewater

  • Sanchis-Perucho, Pau
  • Aguado García, Daniel|||0000-0002-6417-366X
  • FERRER, J.
  • Seco, Aurora
  • Robles, Ángel
[EN] The aim of this study was to assess the feasibility of using dynamic membranes for direct filtration of municipal wastewater. The influence of different alternative supporting materials (one or two layers of flat open monofilament woven polyamide meshes with 1 or 5 mu m of pore size) was studied. A stable short-term self-forming DM was achieved (from some hours to 3 days) regardless of the supporting material used, producing relatively similar permeate qualities (total suspended solids, chemical oxygen demand, total nitrogen, total phosphorous and turbidity of 67-88 mg L-1, 155-186 mg L-1, 48.7-50.4 mg L-1, 4.7-4.9 mg L-1, and 167-174 NTU, respectively). A DM permeability loss rate of from 5.21 to 10.03 LMH bar(-1) day(-1) was obtained, which depended on the supporting material used. Unfortunately, the preliminary energy, carbon footprint, and economic evaluations performed showed that although DMs obtain higher pollutant captures than conventional treatments (primary settler), the benefits are not enough to justify their use for treating average municipal wastewater. However, this alternative scheme could be suitable for treating higher-loaded MWW with a higher fraction of organic matter in the non-settleable solids., This research work was supported by the Ministerio de Economia, Industria y Competitividad via the fellowship PRE2018-083726. This research work was also possible thanks to the financial aid received from the Ministerio de Economia, Industria y Competitividad during the implementation of the Project "AplicaciOn de la tecnologia de membranas para potenciar la transformaciOn de las EDAR actuales en estaciones de recuperaciOn de recursos." (CTM2017-86751-C1 and CTM2017-86751-C2).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Energy Optimisation and Performance Enhancement in Nutrient Concentration from AnMBR Effluent via Electrodialysis for Resource Recovery

  • Hernández Cuenca, Silvia
  • Serralta Sevilla, Joaquín|||0000-0001-5015-0689
  • Barat, Ramón|||0000-0003-0484-3614
  • Carrillo-Abad, J.
  • Bouzas, A.
[EN] Optimising energy consumption in electrodialysis systems treating real wastewater effluents remains a challenge, which is essential to be feasible and applicable. In this sense, long-term experiments were conducted under varying currents and applied voltages (0.1A, 7.5V and 10V), aiming to determine the best operating conditions. Subsequently, long-term experiments were performed regarding operational mode in one-stage and two-stage, number of cell pairs, relaxation stages and different influent nutrient concentration to determine the most suitable configuration of an electrodialysis stack treating free-sulphide Anaerobic Membrane Bioreactor effluent. All experiments performed successfully in terms of efficiencies, achieving 88.8±3.1% and 79.6±5.1% nitrogen and phosphorus removal, with 80.2±7.7% and 73.6±11.3% recovery, respectively. Approximately 100% of total current efficiency resulted in experiments, confirming good performance, although only a tiny fraction of current is used by the ions of interest. The best one-stage performance occurred at 7.5V, improved when operating in two stages and when increasing number of cell pairs. Indeed, two-stages operation with 20 cell pairs represented the most favourable condition, enabling compliance with DIRECTIVE (EU) 2024/3019 while maintaining low energy demand (0.17 kWh/m3, 29.92 kWh/kg P recovered, and 4.05 kWh/kg N recovered). Relaxation stages provided no further improvements, whereas higher influent nutrient concentration enhance nutrient recovery., This research work has been supported by the Spanish Ministry of Science and Innovation by "RECREATE" (PID2020-114315RB-C21/22) and "MEM4REC" (CTM2017-86751-C2-1/2-R) projects, jointly with the European Regional Development Fund (ERDF) , which are gratefully acknowledged. Authors would also like to thank the Vice-Rectorate for Research at the Universitat Politecnica de Valencia (PAID-11-24 and PAID-01-23) and the Vice-Rectorate for Research at the Universitat de Valencia (UV-INV-AE-3673218) for their support.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Building a simple multivariable filtration model to predict irreversible fouling when directly filtering municipal wastewater

  • Sanchis-Perucho, Pau
  • Aguado García, Daniel|||0000-0002-6417-366X
  • Harmand, Jerome
  • Feddaoui-papin, Aida
  • Robles Martínez, Ángel
[EN] This paper describes a simple generic model designed to predict membrane fouling in municipal wastewater (MWW) treatment. The work was conducted using data from a direct membrane filtration demo-system (middle/ long-term filtration periods of about 35 - 124 days) to calibrate the model. Two influents were treated by the demo-system: raw pre-treated MWW and primary settler supernatant from a full-scale MWW treatment plant. A resistance-in-series mathematical model structure was proposed considering fouling due to two different mechanisms: persistent cake layer formation (from suspended material) and pore blocking (from soluble and colloidal compounds). The proposed model represented transmembrane pressure dynamics at different operating solids concentrations (around 1, 2.6, 6 and 11 gL-1) using 7 model parameters, achieving 7-28 mbar differences between the experimental data and model predictions in all cases (calculated as the root mean square error). The model was also able to match the results from two different influents (raw MWW and primary settler supernatant) by modifying 3 of the 7 parameters while low uncertainties were obtained in long-term filtrations, demonstrating its robustness. This model thus provides a good potential to generate reasonable membrane fouling predictions while its simple and open structure makes it easy to implement with complementary materials. Further research will be carried out to enhance the model's precision and validate its potential for optimizing filtration and fouling control processes., This research work was supported by the Ministerio de Economia, Industria y Competitividad via Grant N degrees PRE2018-083726. It was also made possible thanks to the financial support received from the above Ministry during the implementation of the Project " Aplicacion de la tecnologia de membranas para potenciar la transformacion de las EDAR actuales en estaciones de recuperacion de recursos ." (CTM2017-86751-C1 and CTM2017-86751-C2) .
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Assessing and modeling nitrite inhibition in microalgae-bacteria consortia for wastewater treatment by means of photo-respirometric and chlorophyll fluorescence techniques

  • Aparicio, Stéphanie
  • Robles, Ángel
  • FERRER, J.
  • Seco, Aurora
  • Borrás Falomir, Luis
[EN] Total nitrite (TNO2 = HNO2 + NO2-) accumulation due to the activity of ammonia-oxidizing bacteria (AOB) was monitored in microalgae-bacteria consortia, and the inhibitory effect of nitrite/free nitrous acid (NO2-N/FNA) on microalgae photosynthesis and inhibition mechanism was studied. A culture of Scenedesmus was used to run two sets of batch reactors at different pH and TNO2 concentrations to evaluate the toxic potential of NOrN and FNA. Photo-respirometric tests showed that NO2-N accumulation has a negative impact on net oxygen production rate (OPRNET). Chlorophyll a fluorescence analysis was used to examine the biochemical effects of NO2-N stress and the mechanism of NO2-N inhibition. The electron transport rate (ETR), non-photochemical quenching (NPQ), and JIP-test revealed that the electron transport chain between Photosystems II and I (PS II and PS I) was hindered at NO2-N concentrations above 25 g N m(-3). Electron acceptor Q(A) was not able to rcoxidize and could not transfer electrons to the next electron acceptor, Q(B), accumulating P-680(+) (excited PS II reaction center) and limiting oxygen production. A semi-continuous reactor containing a Scenedesmus culture was monitored by photo-respiromeiry tests and Chlorophyll a fluorescence to calibrate NO2-N inhibition (5-35 g N m(-3)). Non-competitive inhibition and Hill-type models were compared to select the best-fitting inhibition equations. Inhibition was correctly modeled by the Hill-type model and a half inhibition constant (K-L) for OPRNET, NPQ, maximum photosynthetic rate (EERMAX) and the performance index PIABS s was 23.7 +/- 1.2, 26.36 +/- 1.10, 39 +/- 2 and 26.5 +/- 0.4, respectively., This research work was supported by the Spanish Ministry of Economy and Competitiveness (MINECO, Projects CTM2014-54980-C2-1-R, CTM2014-54980-C2-2-R, CTM2017-86751-C2-1-R and CTM2017-86751-C2-2-R) jointly with the European Regional Development Fund (ERDF) , both of which are gratefully acknowledged. It was also supported by the Spanish Ministry of Education, Culture and Sport via a pre-doctoral FPU fel-lowship to author Stephanie Aparicio (FPU/15/02595) .
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Nitrogen recovery using a membrane contactor: Modelling nitrogen and pH evolution

  • Noriega-Hevia, Guillermo
  • Borrás, L.
  • Seco, A.
  • FERRER, J.
  • Serralta Sevilla, Joaquín|||0000-0001-5015-0689
[EN] A hollow fibre membrane contactor has been applied for nitrogen recovery from anaerobic digestion supernatant at different operating conditions obtaining nitrogen recovery efficiencies over 99 %. A mathematical model able to represent the time evolution of pH and nitrogen concentration during the recovery process is presented in this paper. The developed model accurately reproduced the results obtained in 26 experiments carried out at different pH values (from 9 to 11), temperatures (from 25 to 35 degrees C), membrane surfaces (from 1.2 to 2.4 m(2)) and feed flow rates (from 0.33 x 10(-5) to 5.83 x 10(-5) m(3)/s) predicting the variations in nitrogen recovery rates measured at the different operating conditions evaluated. Furthermore, due to the combination of nitrogen and pH modelling, the model is able to predict the variations in OH-concentration (alkali addition) required to increase and maintain the pH during the process. Thus, this model is a useful tool for process design and optimisation since it can predict nitrogen recovery rates and reagents consumption at different operational conditions such as flow rate, pH, membrane surface and temperature., This research was financially supported by the Spanish Ministry of Economy and Competitiveness (MINECO projects CTM2014-54980-C21/2-R and CTM2017-86751-C2-1/2-R) with the European Regional Development Fund (ERDF) as well as the Universitat Politecnica de Valencia via a pre-doctoral FPI fellowship to the first author.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Dynamic Membranes for Enhancing Resources Recovery from Municipal Wastewater

  • Sanchis-Perucho, Pau
  • Aguado García, Daniel|||0000-0002-6417-366X
  • FERRER, J.
  • Seco, Aurora
  • Robles, Ángel
[EN] This paper studied the feasibility of using dynamic membranes (DMs) to treat municipal wastewater (MWW). Effluent from the primary settler of a full-scale wastewater treatment plant was treated using a flat 1 mu m pore size open monofilament polyamide woven mesh as supporting material. Two supporting material layers were required to self-form a DM in the short-term (17 days of operation). Different strategies (increasing the filtration flux, increasing the concentration of operating solids and coagulant dosing) were used to enhance the required forming time and pollutant capture efficiency. Higher permeate flux and increased solids were shown to be ineffective while coagulant dosing showed improvements in both the required DM forming time and permeate quality. When coagulant was dosed (10 mg L-1) a DM forming time of 7 days and a permeate quality of total suspended solids, chemical oxygen demand, total nitrogen, total phosphorous and turbidity of 24 mg L-1, 58 mg L-1, 38.1 mg L-1, 1.2 mg L-1 and 22 NTU, respectively, was achieved. Preliminary energy and economic balances determined that energy recoveries from 0.032 to 0.121 kWh per m(3) of treated water at a cost between euro0.002 to euro0.003 per m(3) of treated water can be obtained from the particulate material recovered in the DM., This research work was supported by Ministerio de Economia, Industria y Competitividad via the fellowship PRE2018-083726. This research work was also possible thanks to the financial received from Ministerio de Economia, Industria y Competitividad during the implementation of the Project ¿Aplicación de la tecnología de membranas para potenciar la transformación de las EDAR actuales en estaciones de recuperación de recursos.¿ (CTM2017-86751-C1 and CTM2017-86751-C2).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Electrodialysis Parameter Optimisation following Aeration Strategy of Anaerobic Membrane Bioreactor effluent to Enhance Water Quality and Nutrient Recovery

  • Hernández Cuenca, Silvia
  • Serralta Sevilla, Joaquín|||0000-0001-5015-0689
  • Barat, Ramón|||0000-0003-0484-3614
  • Carrillo-Abad, J.
  • Bouzas, A.
[EN] Considering scaling and membrane adsorption limiting phosphorus recovery in previous studies, this work proposes integrating Anaerobic Membrane Bioreactor effluent aeration with Electrodialysis, improving treatment performance. The objective is to produce two streams: a nutrient-rich stream suitable for recovery, and a diluted stream meeting discharge regulations. Short-term experiments were conducted under varying currents and applied voltages, aiming to determine the best operating conditions. Subsequently, long-term experiments were conducted to assess operational stability, and overall system performance. Results indicated that 0.1A and 7.5V were the best values for galvanostatic and potentiostatic mode. Moreover, long-term tests demonstrated that electrodialysis effectively concentrated nitrogen and phosphorus, enabling their recovery, while reducing pollutant load in the effluent. Specifically, in the concentrate up to 952.35 mg NH4-N/L and 72.44 mg PO4-P/L at 0.1A and 856.04 mg NH4-N/L and 70.05 mg PO4-P/L at 7.5V resulted. Diluted stream meets regulations for nitrogen, obtaining 4.7±0.9 and 3.6±0.5 mg/L at galvanostatic and potentiostatic mode. These findings highlight electrodialysis as a promising and sustainable strategy for nutrient recovery and effluent management in advanced wastewater treatment, although strategies such as multi-stage ED, increasing membrane area, anti-scaling coatings or cleaning protocols are necessary to improve phosphorus removal and ensure compliance with regulatory standards., This research work has been supported by the Spanish Ministry of Science and Innovation by "RECREATE" (PID2020-114315RB-C21/22) and "MEM4REC" (CTM2017-86751-C2-1/2-R) projects, jointly with the European Regional Development Fund (ERDF) , which are gratefully acknowledged. Authors would also like to thank the Vice-Rectorate for Research at the Universitat Politecnica de Valencia (PAID-11-24 and PAID-01-23) and the Vice-Rectorate for Research at the Universitat de Valencia (UV-INV-AE-3673218) for their support.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Modeling the anaerobic treatment of sulfate rich urban wastewater. Application to AnMBR technology

  • Durán, Freddy
  • Robles Martínez, Ángel
  • Giménez, Juan Bautista
  • FERRER, J.
  • Ribes, Josep
  • Serralta Sevilla, Joaquín|||0000-0001-5015-0689
[EN] Although anaerobic membrane bioreactors (AnMBR) are a core technology in the transition of urban wastewater (UWW) treatment towards a circular economy, the transition is being held back by a number of bottlenecks. The dissolved methane released from the effluent, the need to remove nutrients (ideally by recovery), or the energy lost by the competition between methanogenic and sulfate-reducing bacteria (SRB) for the biodegradable COD have been identified as the main issues to be addressed before AnMBR becomes widespread. Mathematical modeling of this technology can be used to obtain further insights into these bottlenecks plus other valuable information for design, simulation and control purposes. This paper therefore proposes an AnMBR anaerobic digestion model to simulate the crucial SRB-related process since these bacteria degrade more than 40% of the organic matter. The proposed model, which is included in the BNRM2 collection model, has a reduced but all-inclusive structure, including hydrolysis, acidogenesis, acetogenesis, methanogenesis and other SRB-related processes. It was calibrated and validated using data from an AnMBR pilot plant treating sulfate-rich UWW, including parameter values obtained in off-line experiments and optimization methods. Despite the complex operating dynamics and influent composition, it was able to reproduce the process performance. In fact, it was able to simulate the AD of sulfate-rich UWW considering only two groups of SRB: heterotrophic SRB growing on both VFA (propionate) and acetate, and autotrophic SRB growing on hydrogen. Besides the above-mentioned constraints, the model reproduced the dynamics of the mixed liquor solids concentration, which helped to integrate biochemical and filtration models. It also reproduced the alkalinity and pH dynamics in the mixed liquor required for assessing the effect of chemical precipitation on membrane scaling., This research work was supported by the Spanish Ministry of Economy and Competitiveness [Grants CTM2011-28595-C02-01/02, CTM2017-86751-C2-1-R and CTM2017-86751-C2-2-R]; Co-funded by the European Regional Development Fund [Grant CTM2011-28595-C02-01/02].
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Long-term electrodialysis nutrient concentration from anaerobic membrane bioreactor effluents: Challenges for calcium sulfate precipitation

  • Ruiz-Barriga, Patricia
  • Bouzas, A.
  • Carrillo-Abad, J.
  • Hernández Cuenca, Silvia
  • Serralta Sevilla, Joaquín|||0000-0001-5015-0689
  • Barat, Ramón|||0000-0003-0484-3614
[EN] Fertilizer requirements keep rising while phosphorus reserves diminish, and Haber-Bosch process contributes significantly to the greenhouse effect. In this sense, transforming conventional Wastewater Treatment Plants (WWTP) into resource recovery facilities (RRF) seems an attractive option. Electrodialysis enables the separation of ions from solution, generating dilute and concentrated effluents. Hard waters with high sulfate concentrations, such as Spanish Mediterranean basins, generate gypsum during the process, hindering nutrient concentration. Therefore, different long-term approaches were tested with AnMBR effluent to address this challenge. Although gypsum precipitation could not be avoided, pH control in the concentrated stream with HCl delayed the phenomenon. However, approximately 500 mg·L¿1 NH4-N and 60 mg·L¿1 PO4-P were obtained in the concentrate when bulk precipitation was observed. In contrast, using softened water yielded concentrations above 1500 mg·L¿1 NH4-N and 135 mg·L¿1 PO4-P, corresponding to 24.3- and 39.5-fold increases over their initial values and confirming that ED is suitable for soft AnMBR effluents. Energy consumption ranged from 0.2 to 0.6 kWh·m¿3, requiring further reduction to facilitate the process scale-up. Nonetheless, nitrogen production showed similar values (7.2 to 17.6 kWh·kgN¿1) to those of the Haber-Bosch industrial process (8.9¿19.3 kWh·kgN¿1). Regarding the effluent, all the hard water experiments met the least restrictive requirements of DIRECTIVE (EU) 2024/3019 of 10 mg·L¿1 NH4-N and 0.7 mg·L¿1 PO4-P. Therefore, ED appears an interesting option for transforming WWTP into RRF., This research work has been supported by the Spanish Ministry of Science and Innovation by "RECREATE" (PID2020-114315RB-C21/22) and "MEM4REC" (CTM2017-86751-C2-1/2-R) projects, jointly with the European Regional Development Fund (ERDF) and the Vice-Rectorate for Research at the Universitat de Valencia (UV-INV-AE-3673218) for their support, which are gratefully acknowledged.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Using machine learning techniques to predict ammonium concentration in membrane contactors for nitrogen recovery as a valuable resource

  • Aguado García, Daniel|||0000-0002-6417-366X
  • Serralta Sevilla, Joaquín|||0000-0001-5015-0689
  • Noriega-Hevia, G.
  • Seco, A.
[EN] The availability of real-time measurements of primary quality water variables is one of the key challenges in the wastewater treatment industry. However, due to the cost and maintenance requirements of sensors and probes for on-line measurement of primary quality variables, the prediction of these variables via data-driven approaches using as inputs easy-to-measure process variables has attracted research interest. In this paper, different machine learning techniques: feed-forward artificial neural network, random forest, support vector machine, gaussian process regression and partial least squares were used to predict in real-time the total ammonium nitrogen concentration during the operation of a hollow fibre membrane contactor. This recently developed technology allows the recovery of nitrogen from nitrogen rich streams (i.e. supernatant of anaerobic digesters in wastewater treatment plants) as ammonium sulphate (a marketable fertilizer). These contactors are usually operated in batch mode, pumping the high nitrogen concentration feed from the storage tank, where the total ammonium nitrogen concentration decreases progressively as the fertilizer is produced. Knowing the real-time concentration of total ammonium nitrogen in the storage tank would enable the optimization of the process operation, avoiding its operation with conservative fixed-time batch duration. The pH is an easy-to-measure process variable usually available in wastewater treatment plants that was used as input of the tested datadriven models, together with two extracted features from this variable (its derivative and increments after each reagent dosing). The number of total ammonium nitrogen measurements in the collected database is 2350 data points (corresponding to 8 complete batches, which were divided into 6 for training the data-driven models and 2 for testing them), ranging from 987 to 2.5 mg NH4+-N/L which covers almost the complete range of total ammonium nitrogen concentration values in the membrane contactor. The predictive ability of the developed predictive models was evaluated on the test data set by four indices, namely: the root-mean-square error, the slope and the intercept of the linear fit between the measured and predicted concentrations and the determination coefficient. The results showed a strong predictive ability of the fitted ANN that outperformed the other approaches exhibiting a determination coefficient of 0.99 and the lowest root-mean-square error (19.87 mg/L) in the test set. Permutation variable importance demonstrated that all machine learning techniques depended mainly on the two variables extracted from the pH: its derivative and increments, which resulted to be more important than the pH itself to predict the total ammonium nitrogen concentration., This research was financially supported by the Spanish Ministry of Economy and Competitiveness (MINECO projects CTM2014-54980-C2-1/2-R and CTM2017-86751-C2-1/2-R) with the European Regional Development Fund (ERDF) as well as the Universitat Politecnica de Valencia via a predoctoral FPI fellowship to Guillermo Noriega. We would also like to thank the anonymous reviewers for their suggestions that have contributed to improving this work.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Evaluating resource recovery potential and process feasibility of direct membrane ultrafiltration of municipal wastewater at demonstration scale

  • Sanchis-Perucho, Pau
  • Aguado García, Daniel|||0000-0002-6417-366X
  • Ferrer, J.
  • Seco Torrecillas, Aurora
  • Robles Martínez, Ángel
[EN] The aim of this work was to assess the feasibility of applying ultrafiltration membranes for the direct filtration of municipal wastewater. The effect of different influents (raw wastewater and the primary settler effluent of a municipal wastewater treatment plant) and operating solids concentration (about 1, 2.6, 6 and 11 g L¿1) was evaluated. Increasing the operating solids concentration sharply reduced membrane fouling, achieving a minimum of about 0.55 mbar per day when operating above 6 g L¿1. Filtering raw municipal wastewater also had a beneficial effect on the filtration performance, although only when operating at a low solids concentration (under 2.6 g L¿1). High quality permeates were obtained regardless of operating conditions, meeting European discharge requirements for no sensible environments. High resource recoveries were achieved thanks to the direct filtration of wastewater, capturing about 80-85 and 20%¿40% of the influent COD and nutrients, respectively. The energy and carbon footprint balances showed promising results, achieving energy recoveries and carbon footprints of about 0.46-0.40 kWh per m3 of influent municipal wastewater and -[0.19-0.16] kg CO2-eq per m3 of influent municipal wastewater when considering the process energy demands and potential energy recovery. Additionally, profits can be obtained from MWW treatment by this alternative, achieving about €0.035¿0.021 per m3 of influent MWW when operating at a flux of 10 LMH which entail a payback period for the initial membrane acquisition of 12.3¿20.1 years., This research work was supported by the Spanish Ministerio de Economia, Industria y Competitividad via Fellowship PRE2018-083726. It was also possible thanks to the finance received from the Ministerio de Economia, Industria y Competitividad, Spain during the implementation of the Project "Aplicacion de la tecnologia de membranas para potenciar la transformacion de las EDAR actuales en estaciones de recuperacion de recursos" (CTM2017-86751-C1 and CTM2017- 86751-C2) . The EPSAR (Entidad Publica de Saneamiento de Aguas de la Comunitat Valenciana) , Spain is gratefully acknowledged for its support for this work.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Direct Membrane Filtration of MunicipalWastewater: Studying the Most Suitable Conditions for Minimizing Fouling Rate in Commercial Porous Membranes at Demonstration Scale

  • Sanchis-Perucho, Pau
  • Aguado García, Daniel|||0000-0002-6417-366X
  • FERRER, J.
  • Seco, Aurora
  • Robles, Ángel
[EN] This study aimed to evaluate the feasibility of applying a commercial porous membrane to direct filtration of municipal wastewater. The effects of membrane pore size (MF and UF), treated influent (raw wastewater and the primary settler effluent of a municipal wastewater treatment plant) and operating solids concentration (about 1 and 2.6 g L-1) were evaluated on a demonstration plant. Filtration periods of 2-8 h were achieved when using the MF membrane, while these increased to 34-69 days with the UF membrane. This wide difference was due to severe fouling when operating the MF membrane, which was dramatically reduced by the UF membrane. Use of raw wastewater and higher solids concentration showed a significant benefit in the filtration performance when using the UF module. The physical fouling control strategies tested (air sparging and backwashing) proved to be ineffective in controlling UF membrane fouling, although these strategies had a significant impact on MF membrane fouling, extending the operating period from some hours to 5-6 days. The fouling evaluation showed that a cake layer seemed to be the predominant reversible fouling mechanism during each independent filtration cycle. However, as continuous filtration advanced, a large accumulation of irreversible fouling appeared, which could have been related to intermediate/complete pore blocking in the case of the MF membrane, while it could have been produced by standard pore blocking in the case of the UF membrane. Organic matter represented more than 70% of this irreversible fouling in all the experimental conditions evaluated., This research work was supported by the Spanish Ministerio de Economia, Industria y Competitividad via Fellowship PRE2018-083726 and was also possible thanks to the funding received from Ministerio de Economia, Industria y Competitividad during the implementation of the Project "Aplicacion de la tecnologia de membranas para potenciar la transformacion de las EDAR actuales en estaciones de recuperacion de recursos." (CTM2017-86751-C1 and CTM2017-86751-C2).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Global sensitivity and uncertainty analysis of a microalgae model for wastewater treatment

  • Aparicio, Stéphanie
  • Serna-García, Rebecca
  • Seco, Aurora
  • FERRER, J.
  • Borrás Falomir, Luis
  • Robles, Ángel
[EN] The results of a global sensitivity and uncertainty analysis of a microalgae model applied to a Membrane Photobioreactor (MPBR) pilot plant were assessed. The main goals of this study were: (I) to identify the sensitivity factors of the model through the Morris screening method, i.e. the most influential factors; (II) to calibrate the influential factors online or offline; and (III) to assess the model's uncertainty. Four experimental periods were evaluated, which encompassed a wide range of environmental and operational conditions. Eleven influential factors (e.g. maximum specific growth rate, light intensity and maximum temperature) were identified in the model from a set of 34 kinetic parameters (input factors). These influential factors were preferably calibrated offline and alternatively online. Offline/online calibration provided a unique set of model factor values that were used to match the model results with experimental data for the four experimental periods. A dynamic optimization of these influential factors was conducted, resulting in an enhanced set of values for each period. Model uncertainty was assessed using the uncertainty bands and three uncertainty indices: p-factor, r-factor and ARIL. Uncertainty was dependent on both the number of influential factors identified in each period and the model output analyzed (i.e. biomass, ammonium and phosphate concentration). The uncertainty results revealed a need to apply offline calibration methods to improve model performance., This research work was supported by the Spanish Ministry of Economy and Competitiveness (MINECO, Projects CTM2014-54980-C2-1-R, CTM2014-54980-C2-2-R, CTM2017-86751-C2-1-R and CTM2017-86751-C2-2-R) jointly with the European Regional Development Fund (ERDF) , both of which are gratefully acknowledged. It was also supported by the Spanish Ministry of Education, Culture and Sport via a pre-doctoral FPU fellowship to author Stephanie Aparicio (FPU/15/02595) .
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Boosting nutrient recovery from AnMBR effluent by means of electrodialysis technology: Operating parameters assessing

  • Ruiz-Barriga, Patricia
  • Bouzas, A.
  • Carrillo-Abad, Jordi
  • Serralta Sevilla, Joaquín|||0000-0001-5015-0689
[EN] This work describes a comprehensive assessment of operating parameters of a bench-scale electrodialysis (ED) plant for nutrient concentration from an Anaerobic Membrane BioReactor (AnMBR) effluent. The ED bench-scale plant serves a dual purpose. Firstly, to generate a concentrated stream with a high nutrient content, and secondly, to produce high-quality reclaimed water in the diluted stream, both sourced from real wastewater coming from the effluent of an AnMBR. Two sets of experiments were conducted: 1) short-term experiments to study the effect of some parameters such as the applied current and the type of anionic exchange membrane (AEM), among others, and 2) a long-term experiment to verify the feasibility of the process using the selected parameters. The results showed that ED produced concentrated ammonium and phosphate streams using a 10-cell pair stack with 64 cm(2) of unitary effective membrane area, working in galvanostatic mode at 0.24 A, and operating with an Acid-100-OT anionic exchange membrane. Concentrations up to 740 mg/L and 50 mg/L for NH4-N and PO4-P, respectively, were achieved in the concentrated stream along with removal efficiencies of 70% for ammonium and 60% for phosphate in the diluted stream. The average energy consumption was around 0.47 kWh.m(-3)., This research work has been supported by the Spanish Ministry of Science and Innovation by "RECREATE" (PID2020-114315RB-C21/22) and "MEM4REC" (CTM2017-86751-C2-1/2-R) projects, jointly with the European Regional Development Fund (ERDF) , which are gratefully acknowledged.