Skip to main content

NUEVAS HERRAMIENTAS QUIMIOMETRICAS CON VARIABLES LATENTES PARA LA TOMA DE DECISIONES EN TECNOLOGIA ANALITICA DE PROCESOS Y EN CONTEXTOS REGULADOS DE SEGURIDAD ALIMENTARIA

CTQ2017-88894-R

•
Funding agency name Agencia Estatal de Investigación
Funding agency acronym AEI
Program Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Call Proyectos I+D+i Retos de Investigación
Call year 2017
State Plan 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Beneficiary centre UNIVERSIDAD DE BURGOS

Resultados relacionados

Resultados totales (Incluyendo duplicados): 4
Encontrada(s) 1 página(s)

Repositorio Institucional de la Universidad de Burgos (RIUBU)
Publication Artículo científico (JournalArticle)

A new approach based on inversion of a partial least squares model searching for a preset analytical target profile. Application to the determination of five bisphenols by liquid chromatography with diode array detector

  • Arce Antón, Mar
  • Ruiz Miguel, Santiago
  • Sanllorente Méndez, Silvia
  • Ortiz Fernández, Mª Cruz
  • Sarabia Peinador, Luis Antonio
  • Sánchez Pastor, Mª Sagrario
The paper shows a procedure for selecting the control method parameters (factors) to obtain a preset ‘analytical target profile’ when a liquid chromatographic technique is going to be carried out for the simultaneous determination of five bisphenols (bisphenol-A, bisphenol-S, bisphenol-F, bisphenol-Z and bisphenol-AF), some of them regulated by the European Union. The procedure has three steps. The first consists of building a D-optimal combined design (mixture-process design) for the control method parameters, which are the composition of the ternary mobile phase and its flow rate. The second step is to fit a PLS2 model to predict six analytical responses (namely, the resolution between each pair of consecutive peaks, and the initial and final chromatographic time) as a function of the control method parameters. The third final step is the inversion of the PLS2 model to obtain the conditions needed for attaining a preset analytical target profile. The computational inversion of the PLS2 prediction model looking for the Pareto front of these six responses provides a set of experimental conditions to conduct the chromatographic determination, specifically 22% of water, mixed with 58% methanol and 20% of acetonitrile, keeping the flow rate at 0.66 mL min−1. These conditions give a chromatogram with retention times of 2.180, 2.452, 2.764, 3.249 and 3.775 min for BPS, BPF, BPA, BPAF and BPZ, respectively, and excellent resolution among all the chromatographic peaks. Finally, the analytical method is validated under the selected experimental conditions, in terms of trueness and precision. In addition, the detection capability for the five bisphenols were: 596, 334, 424, 458 and 1156 μg L−1, with probabilities of false positive and of false negative equal to 0.05., Spanish MINECO (AEI/FEDER, UE) and Consejería de Educación de la JCyL through projects CTQ2017-88894-R and BU052P20, co-financed with European Regional Development Funds
Repositorio Institucional de la Universidad de Burgos (RIUBU)
Publication Artículo científico (JournalArticle)

A modified entropy-based performance criterion for class-modelling with multiple classes

  • Valencia García, Olga
  • Ortiz Fernández, Mª Cruz
  • Sánchez Pastor, Mª Sagrario
  • Sarabia Peinador, Luis Antonio
The paper presents a new proposal for a single overall measure, the diagonal modified confusion entropy (DMCEN), to assess the performance of class-models jointly computed for several classes, a versatile index regarding sensitivity and specificity, and that supports class weighting. The characteristics of the proposed figure of merit are illustrated as against other usual performance measures and show how the index is more sensitive to the variations in the class-models than similar published indexes. Besides, a benchmark value representing a random modelling is also defined for DMCEN to be used as initial level to assess the quality of the built class-models. Furthermore, systematic comparisons have been conducted by using the degree of consistency C and the degree of discriminancy D when comparing the proposed DMCEN to the usual total efficiency (a geometric mean between sensitivity and specificity). Simulations show that, for a hundred thousand sensitivity/specificity matrices with four categories, C is almost 0.7 on average, well above the needed 0.5, and there is more than 62% probability that DMCEN detects differences when the total efficiency does not. Illustration of the application of the index is shown with an experimental data set with four categories., Spanish Ministerio de Ciencia, Innovaci on y Universidades (AEI) and Consejería de Educación de la Junta de Castilla y León through projects CTQ2017-88894-R and BU052P20 respectively (both co-financed with European Regional Development Funds)
Repositorio Institucional de la Universidad de Burgos (RIUBU)
Publication Artículo científico (JournalArticle)

Method operable design region obtained with a partial least squares model inversion in the determination of ten polycyclic aromatic hydrocarbons by liquid chromatography with fluorescence detection

  • Arce Antón, Mar
  • Sanllorente Méndez, Silvia
  • Ruiz Miguel, Santiago
  • Sánchez Pastor, Mª Sagrario
  • Sarabia Peinador, Luis Antonio
  • Ortiz Fernández, Mª Cruz
A chromatographic method with the Analytical Quality by Design (AQbD) methodology is developed for the simultaneous determination by HPLC-FLD of ten PAHs (naphthalene, phenanthrene, anthracene, flu- oranthene, pyrene, chrysene, benzo[a]anthracene, perylene, benzo[b]fluoranthene, and benzo[a]pyrene), widely spread in the environment. The construction of the Method Operable Design Region (MODR) is conducted, for the first time, via the inversion of a multiresponse Partial Least Squares (PLS2) model, which is needed to maintain the correlations among the Critical Method Parameters (CMP), among the Critical Quality Attributes (CQA), and the covariance between one another. The five CMP considered were the composition of the mobile phase (water, methanol, acetonitrile), flow rate, and column temperature. The eight CQA were linked to resolution between peaks recorded in the same emission wavelength (greater than 1.4) and the total time (less than 15 minutes). By systematic use of experimental design and parallel coordinates plots to explore the Pareto optimal front obtained with the PLS2 model inversion, the computed MODR is formed by convex combinations of eight specific settings of Critical Method Parameters that have a mobile phase with percentages of water between 37 and 38 %, of methanol from 13 and 22 %, and of acetonitrile between 41 and 49 %, together with a flow rate between 1.47 and 1.50 mL min −1 , and column temperature between 41.9 and 44.0 °C in their adequate combinations. All the chromatographic peaks are well resolved, with total time varying between 12.96 and 15.66 min inside the estimated MODR and the analytical method is accurate with CC βbetween 0.9 and 7.0 μg L −1 with probability of both false positive and false negative equal to 0.05., Research projects CTQ2017-88894-R and BU052P20, financed by the Spanish Ministerio de Ciencia, Innovación y Universidades (AEI/FEDER, UE) and Consejería de Educación de la Junta de Castilla y León, both cofinanced with European Development Funds. M.M. Arce wishes to thank Junta de Castilla y León for her postdoctoral contract through BU052P20 project.
Repositorio Institucional de la Universidad de Burgos (RIUBU)
Publication Artículo científico (JournalArticle)

Determination of polymer additive residues that migrate from coffee capsules by means of stir bar sorptive extraction-gas chromatography-mass spectrometry and PARAFAC decomposition

  • Valverde Som, Lucía
  • Reguera Alonso, Celia
  • Herrero Gutiérrez, Ana
  • Sarabia Peinador, Luis Antonio
  • Ortiz Fernández, Mª Cruz
This paper reports on the difficulties encountered when developing an analytical method for ultra-trace determination, in a complex matrix, of plastic additive residues which are ubiquitous in the laboratory. The simultaneous qualitative and quantitative determination of an antioxidant (2,6-di-tert-butyl-4-methyl-phenol, BHT), an UV stabilizer (benzophenone, BP), and a plasticizer (diisobutyl phthalate, DiBP), released from plastic capsules is carried out in coffee by means of GC–MS and parallel factor analysis decomposition. Stir bar sorptive extraction is used to extract and concentrate the analytes. Coffee samples are prepared with Milli-Q water, which contains residues of the target compounds, which can be significant for ultra-trace analysis and should be subtracted. In addition, matrix effect exits in coffee, so standard addition method is used. The residue concentrations released from the coffee capsules into the solid coffee are around 3, 1, and 12 μg kg−1 of BHT, BP and DiBP, respectively., Spanish MINECO (AEI/FEDER, UE) through project CTQ2017-88894-R and by Consejería de la Junta de Castilla y León through project BU052P20 (both co-financed with European FEDER funds). L. Valverde-Som thanks JCyL for her postdoctoral contract through BU052P20 project.