DESARROLLO DEL DETECTOR PET/RM PARA DIAGNOSTICO DE ENFERMEDADES NEURODEGENERATIVAS.

FIS2010-21216-C02-01

•
Funding agency name Ministerio de Ciencia e Innovación
Funding agency acronym MICINN
Program Programa Nacional de Proyectos de Investigación Fundamental
Subprogram Subprograma de Proyectos de Investigación Fundamental no Orientada
Call Proyectos I+D
Call year 2010
State Plan 2008-2011 Plan Nacional de Investigación Científica, Desarrollo e Innovación Tecnológica
Management unit Subdirección General de Proyectos de Investigación
Beneficiary centre AGENCIA ESTATAL CONSEJO SUPERIOR DE INVESTIGACIONES CIENTIFICAS (CSIC)

Resultados relacionados

Resultados totales (Incluyendo duplicados): 12
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Simulation study of resistor networks applied to an array of 256 SiPMs

  • González Martínez, Antonio Javier
  • Moreno, Manuel
  • Barberá, Julio
  • Conde Castellanos, Pablo Eloy
  • Hernández Hernández, Liczandro
  • Moliner Martínez, Laura
  • Orero Palomares, Abel
  • Peiró Cloquell, Antonio
  • Polo Collado, Ramiro
  • Ros García, Ana
  • Sánchez Martínez, Filomeno
  • Soriano Asensi, Antonio
  • Vidal San Sebastián, Luis Fernando
  • Monzó Ferrer, José María|||0000-0001-6554-3231
  • Rodríguez-Álvarez, M.J.|||0000-0001-8333-8792
  • Benlloch Baviera, Jose María|||0000-0001-6073-1436
[EN] In this work we describe a procedure to reduce the number of signals detected by an array of 256 Silicon Photo-multipliers (SiPMs) using a resistor network to divide the signal charge into few readout channels. Several configurations were modeled, and the pulsed signal at the readout contacts were simulated. These simulation results were experimentally tested on a specifically designed and manufactured set of printed circuit boards. Three network configurations were modeled. The modeling provided encouraging results for all three configurations. The measurements on the prototypes constructed for this study, however, provided useful position-sensitivity for only one of the network configurations. The lack of input signal amplification into the networks, the SiPM dark current, as well as the complexity of an eight layers board with parasitic capacitances, could have caused the degradation of resolving the impact photon position. This is hard to overcome with external printed circuit boards and components., This work was supported by the Spanish Plan Nacional de Investigación Científica, Desarrollo e Innovación Tecnológica (I+D+I) under Grant FIS2010-21216-CO2-01, the Valencian Local Government under Grant PROMETEO 2008/114 and through the JAE-Predoc grant from CSIC (BOE 29/01/2010).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Design and evaluation of the MAMMI dedicated breast PET

  • Moliner Martínez, Laura
  • González Martínez, Antonio Javier
  • F Sánchez
  • Vidal San Sebastian, Luis Fernando|||0000-0001-8852-8560
  • Seimetz, Michael
  • Benlloch Baviera, Jose María|||0000-0001-6073-1436
  • Soriano Asensi, Antonio
  • Correcher Salvador, Carlos
  • Orero Palomares, Abel
  • Carles Fariña, Montserrat
  • Barberá Ballester, Julio
  • Caballero Ontanaya, Luis
  • Vazquez Barreiros, Carlos
Purpose: A breast dedicated positron emission tomography (PET) scanner has been developed based on monolithic LYSO crystals coupled to position sensitive photomultiplier tubes (PSPMTs). In this study, we describe the design of the PET system and report on its performance evaluation. Methods: MAMMI is a breast PET scanner based on monolithic LYSO crystals. It consists of 12 compact modules with a transaxial field of view (FOV) of 170 mm in diameter and 40 mm axial FOV that translates to cover up to 170 mm. The patient lies down in a prone position that facilitates maximum breast elongation. Quantitative performance analysis of the calculated method for the attenuation correction specifically developed for MAMMI, and based on PET image segmentation, has also been conducted in this evaluation. In order to fully determine the MAMMI prototype’s performance, we have adapted the measurements suggested for National Electrical Manufacturers Association (NEMA) NU 2-2007 and NU 4-2008 protocol tests, as they are defined for whole-body and small animal PET scanners, respectively. Results: Spatial resolutions of 1.6, 1.8, and 1.9 mm were measured in the axial, radial, and tangential directions, respectively. A scatter fraction of 20.8% was obtained and the maximum NEC was determined to be 25 kcps at 44 MBq. The average sensitivity of the system was observed to be 1% for an energy window of (250 keV–750 keV) and a maximum absolute sensitivity of 1.8% was measured at the FOV center. Conclusions: The overall performance of the MAMMI reported on this evaluation quantifies its ability to produce high quality PET images. Spatial resolution values below 3 mm were measured in most of the FOV. Only the radial component of spatial resolution exceeds the 3 mm at radial positions larger than 60 mm. This study emphasizes the need for standardized testing methodologies for dedicated breast PET systems similar to NEMA standards for whole-body and small animal PET scanners, This work was supported by the Spanish Plan Nacional de Investigacion Cientifica, Desarrollo e Innovacion Tecnologica (I+D+I) under Grant No. FIS2010-21216-CO2-01 and Valencian Local Government under Grant Nos. PROMETEO 2008/114 and APOSTD 2010/012. The authors would like to thank Teodor Dima and Brennan Holt for checking and correcting the text.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Small animal PET scanner based on monolithic LYSO crystals: Performance evaluation

  • Sánchez Martínez, Filomeno
  • Moliner Martínez, Laura
  • Correcher, C.
  • González Martínez, Antonio Javier
  • Orero Palomares, Abel
  • Carles Fariña, Montserrat
  • Soriano Asensi, Antonio
  • Medina, L.A
  • Rodríguez-Álvarez, M.J.|||0000-0001-8333-8792
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Benlloch Baviera, Jose María|||0000-0001-6073-1436
Purpose: The authors have developed a small animal Positron emission tomography(PET)scanner based on monolithic LYSO crystals coupled to multi-anode photomultiplier tubes (MA-PMTs). In this study, the authors report on the design, calibration procedure, and performance evaluation of a PET system that the authors have developed using this innovative nonpixelated detector design. Methods : The scanner is made up of eight compact modules forming an octagon with an axial field of view (FOV) of 40 mm and a transaxial FOV of 80 mm diameter. In order to fully determine its performance, a recently issued National Electrical Manufacturers Association (NEMA) NU-4 protocol, specifically developed for small animal PETscanners, has been followed. By measuring the width of light distribution collected in the MA-PMT the authors are able to determine depth of interaction (DOI), thus making the proper identification of lines of response (LORs) with large incidence angles possible. PET performances are compared with those obtained with currently commercially available small animal PETscanners. Results : At axial center when the point-like source is located at 5 mm from the radial center, the spatial resolution measured was 1.65, 1.80, and 1.86 mm full width at half maximum (FWHM) for radial, tangential, and axial image profiles, respectively. A system scatter fraction of 7.5% (mouse-like phantom) and 13% (rat-like phantom) was obtained, while the maximum noise equivalent count rate (NECR) was 16.9 kcps at 12.7 MBq (0.37 MBq/ml) for mouse-like phantom and 12.8 kcps at 12.4 MBq (0.042 MBq/ml) for rat-like phantom The peak absolute sensitivity in the center of the FOV is 2% for a 30% peak energy window. Several animal images are also presented. Conclusions: The overall performance of our small animal PET is comparable to that obtained with much more complex crystal pixelated PET systems. Moreover, the new proposed PET produces high-quality images suitable for studies with small animals., This work was supported by the Spanish Plan Nacional de Investigacion Cientifica, Desarrollo e Innovacion Tecnologica (I+D+I) under Grant No. FIS2010-21216-CO2-01 and Valencian Local Government under Grant No. PROMETEO 2008/114. The authors would like to thank Andrew Duncan for checking and correcting the text.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Results of a combined monolithic crystal and an array of ASICs controlled SiPMs

  • Conde Castellanos, Pablo Eloy
  • González Martínez, Antonio Javier
  • Hernández Hernández, Liczandro
  • Bellido, P.
  • Iborra Carreres, Amadeo
  • Crespo Navarro, Efren
  • Moliner Martínez, Laura
  • Rigla, JP.
  • Sánchez, F.
  • Seimetz, Michael
  • Soriano Asensi, Antonio
  • Vidal San Sebastián, Luis Fernando
  • Rodríguez-Álvarez, M.J.|||0000-0001-8333-8792
  • Benlloch Baviera, Jose María|||0000-0001-6073-1436
[EN] In this work we present the energy and spatial resolutions we have obtained for a γ ray detector based on a monolithic LYSO crystal coupled to an array of 256 SiPMs. Two crystal configurations of the same trapezoidal shape have been tried. In one approach all surfaces were black painted but the exit one facing the photosensor array which was polished. The other approach included a retroreflector (RR) layer coupled to the entrance face of the crystal powering the amount of transmitted light to the photosensors. Two coupling media between the scintillator and the SiPM array were used, namely direct coupling by means of optical grease and coupling through an array of light guides. Since the same operational voltage was supplied to the entire array, it was needed to equalize their gains before feeding their signals to the Data Acquisition system. Such a job was performed by means of 4 scalable Application Specific Circuits (ASICs). An energy resolution of about 24.4% has been achieved for the direct coupling with the RR layer together with a spatial resolution of approximately 2.9 mm at the detector center. With the light guides coupling the effects of image compression at the edges are significantly minimized, but worsening the energy resolution to about 33.1% with a spatial resolution nearing 4 mm at the detector center. & 2013 Elsevier B.V. All rights reserved., cknowledgments This work was supported by the Centre for Industrial Technological Development co-funded by FEDER through the Technology Fund (DREAM Project, IDI-20110718), the Spanish Plan Nacional de Investigación Científica, Desarrollo e Innovación Tecnológica (IþDþI) under Grant no. FIS2010-21216-CO2-01 and the Valencian Local Government under Grant PROMETEO 2008/114
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Analysis of the Statistical Moments of the Scintillation Light Distribution With dSiPMs

  • Conde Castellanos, Pablo Eloy
  • Gonzalez, A.
  • Hernández Hernández, Liczandro
  • Bellido, P.
  • Crespo Navarro, Efren
  • Iborra Carreres, Amadeo
  • Rigla Pérez, Juan Pablo
  • Sanchez, F.
  • Soriano Asensi, Antonio
  • González Martínez, Antonio Javier
  • Moliner Martínez, Laura
  • Rodríguez-Álvarez, M.J.|||0000-0001-8333-8792
  • Seimetz, Michael
  • Vidal San Sebastian, Luis Fernando|||0000-0001-8852-8560
  • Benlloch Baviera, Jose María|||0000-0001-6073-1436
In gamma-ray detectors, monolithic scintillation crystals offer the possibility of preserving the scintillation light distribution especially when painted black. The statistical moments of this distribution provide accurate information on the three photon impact coordinates, including their depth of interaction (DOI). Digital SiPMs (dSiPMs) return digital information based on pixels about the collected light distribution, since the signal is a digital sum of the trigger bins. In this work we present, for the first time, an accurate analysis of the statistical moments of the light distribution using monolithic painted black crystals and state-of-the-art dSiPMs. Two 32.6 x 32.6 mm(2) monolithic LYSO crystals covering the entire photodetectors area have been used in coincidence with 10 mm in thickness. The photosensor tiles were kept at a stable temperature of T = 20 degrees C. Energy resolution of about 18% was reached in relation to the zeroth moment. The first moment, related to the impact position, determined a spatial resolution of about 3 mm near the crystal center, but quadratically degrading towards the crystal borders. The DOI resolution, measured by means of the second moment, was found to be nearing 4 mm in the crystal center region. The third order moment, the so-called skewness, is related to the degree of truncation and once calibrated minimizes the compression effects. A corrected spatial resolution of about 3 mm was then measured for the entire crystal surface. DOI resolution improved at the crystal's center, reaching 3.5 mm, but a degradation towards the borders remained due to truncation of the scintillation light distribution., This work was supported in part by the Spanish Plan Nacional de Investigacion Cientifica, Desarrollo e Innovacion Tecnologica (I+D+I) under Grant FIS2010-21216-CO2-01 and in part by the Valencian Local Government under Grants PROMETEOII/2013/010 and ISIC 2011/013.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

ALBIRA: A small animal PET/SPECT/CT imaging system

  • Sánchez Martínez, Filomeno
  • Orero Palomares, Abel
  • Soriano Asensi, Antonio
  • Correcher Salvador, Carlos
  • Conde Castellanos, Pablo Eloy
  • González Martínez, Antonio Javier
  • Hernández Hernández, Liczandro
  • Moliner Martínez, Laura
  • Vidal San Sebastián, Luis Fernando
  • Chapman, S.E.
  • Rodríguez-Álvarez, M.J.|||0000-0001-8333-8792
  • Benlloch Baviera, Jose María|||0000-0001-6073-1436
  • Leevy, W.M.
Purpose: The authors have developed a trimodal PET/SPECT/CT scanner for small animal imaging. The gamma ray subsystems are based on monolithic crystals coupled to multianode photomultiplier tubes (MA-PMTs), while computed tomography (CT) comprises a commercially available microfocus x-ray tube and a CsI scintillator 2D pixelated flat panel x-ray detector. In this study the authors will report on the design and performance evaluation of the multimodal system. Methods: X-ray transmission measurements are performed based on cone-beam geometry. Individual projections were acquired by rotating the x-ray tube and the 2D flat panel detector, thus making possible a transaxial field of view (FOV) of roughly 80 mm in diameter and an axial FOV of 65 mm for the CT system. The single photon emission computed tomography (SPECT) component has a dual head detector geometry mounted on a rotating gantry. The distance between the SPECT module detectors can be varied in order to optimize specific user requirements, including variable FOV. The positron emission tomography (PET) system is made up of eight compact modules forming an octagon with an axial FOV of 40 mm and a transaxial FOV of 80 mm in diameter. The main CT image quality parameters (spatial resolution and uniformity) have been determined. In the case of the SPECT, the tomographic spatial resolution and system sensitivity have been evaluated with a99mTc solution using single-pinhole and multi-pinhole collimators. PET and SPECT images were reconstructed using three-dimensional (3D) maximum likelihood and ordered subset expectation maximization (MLEM and OSEM) algorithms developed by the authors, whereas the CT images were obtained using a 3D based FBP algorithm. Results: CT spatial resolution was 85μm while a uniformity of 2.7% was obtained for a water filled phantom at 45 kV. The SPECT spatial resolution was better than 0.8 mm measured with a Derenzo-like phantom for a FOV of 20 mm using a 1-mm pinhole aperture collimator. The full width at half-maximum PET radial spatial resolution at the center of the field of view was 1.55 mm. The SPECT system sensitivity for a FOV of 20 mm and 15% energy window was 700 cps/MBq (7.8 × 10−2%) using a multi-pinhole equipped with five apertures 1 mm in diameter, whereas the PET absolute sensitivity was 2% for a 350–650 keV energy window and a 5 ns timing window. Several animal images are also presented. Conclusions: The new small animal PET/SPECT/CT proposed here exhibits high performance, producing high-quality images suitable for studies with small animals. Monolithic design for PET and SPECT scintillator crystals reduces cost and complexity without significant performance degradation., This study was supported by the Spanish Plan Nacional de Investigacion Cientifica, Desarrollo e Innovacion Tecnologica (I+D+I) under Grant No. FIS2010-21216-CO2-01 and Valencian Local Government under Grant PROMETEO 2008/114. The authors also thank Brennan Holt for checking and correcting the text.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Minimization of parallax error in dedicated breast PET

  • Soriano Asensi, Antonio
  • González Martínez, Antonio Javier
  • Sánchez Martínez, Filomeno
  • Conde, Pablo
  • Moliner Martínez, Laura
  • Orero Palomares, Abel
  • Vidal, Luis F.
  • Rodríguez-Álvarez, M.J.|||0000-0001-8333-8792
  • Benlloch Baviera, Jose María|||0000-0001-6073-1436
[EN] The increase of the detector thickness and the incidence angle of impinging photons permits an enhancement of sensitivity in positron emission tomography (PET) scanners. But also increases the parallax error and leads to a worsening of spatial resolution. Instead of introducing hardware modifications in the readout electronics or in the detector, we propose in this work to model the photon penetration depth in the detector material and to account for this effect during the image reconstruction. The validation of the model was based on experimental measurements with the MAMMI breast dedicated PET. It consists of twelve detector modules of monolithic LYSO scintillators. A point-like source was acquired at several radial positions across the field of view. The performance of the model was analyzed in terms of position accuracy and spatial resolution. Full width at half maximum (FWHM) average improvement values of 1.0 mm (radial), 0.4 mm (tangential), and 0.3 mm (axial) have been measured when the photon penetration depth was taken into account. The use of the model proposed in this work allows us to design PET detectors with improved sensitivity while maintaining the spatial resolution of the scanner., This work was supported by the Spanish Plan Nacional de Investigación Científica, Desarrollo e Innovación Tecnológica (I+D+I) under Grant FIS2010-21216-CO2-01 and Valencian Local Government under Grants PROMETEO 2008/114 and APOSTD 2010/012.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

EM tomographic image reconstruction using polarvoxels

  • Soriano Asensi, Antonio
  • Iborra Carreres, Amadeo
  • Carles Fariña, Montserrat
  • Conde Castellanos, Pablo Eloy
  • Hernández Hernández, Liczandro
  • Orero Palomares, Abel
  • Rodríguez-Álvarez, M.J.|||0000-0001-8333-8792
  • F Sánchez
  • González Martínez, Antonio Javier
  • Moliner Martínez, Laura
  • Vidal San Sebastian, Luis Fernando|||0000-0001-8852-8560
  • Benlloch Baviera, Jose María|||0000-0001-6073-1436
[EN] The splitting of the field of view (FOV) in polar voxels is proposed in this work in order to obtain an efficient description of a cone-beam computed tomography (CT) scanner. The proposed symmetric-polar pixelation makes it possible to deal with the 3D iterative reconstruction considering a number of projections and voxel sizes typical in CT preclinical imaging. The performance comparison, between the filtered backprojection (FBP) and 3D maximum likelihood expectation maximization (MLEM) reconstruction algorithm for CT, is presented. It is feasible to achieve the hardware spatial resolution limit with the considered pixelation. The image quality achieved with MLEM and FBP have been analyzed. The results obtained with both algorithms in clinical images have been compared too. Although the polar-symmetric pixelation is presented in the context of CT imaging, it can be applied to any other tomographic technique as long as the scan comprises the measurement of an object under several projection angles., This work was supported by the Spanish Plan Nacional de Investigaci´on Cient´ıfica, Desarrollo e Innovaci´on Tecnol´ogica (I+D+I) under Grant No. FIS2010-21216-CO2-01 and Valencian Local Government under Grants PROMETEO/2008/114, ISIC/2012/013 and APOSTD/2010/012.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Design of the PET–MR system for head imaging of the DREAM Project

  • González Martínez, Antonio Javier
  • Conde, P.
  • Hernández Hernández, Liczandro
  • Moliner Martínez, Laura
  • Orero Palomares, Abel
  • Peiró Cloquell, Antonio
  • Rodríguez-Alvarez, M.J.
  • Ros García, Ana
  • Sánchez Martínez, Filomeno
  • Soriano Asensi, Antonio
  • Vidal San Sebastián, Luis Fernando
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Monzó Ferrer, José María|||0000-0001-6554-3231
  • Benlloch Baviera, Jose María|||0000-0001-6073-1436
In this paper we describe the overall design of a PET–MR system for head imaging within the framework of the DREAM Project as well as the first detector module tests. The PET system design consists of 4 rings of 16 detector modules each and it is expected to be integrated in a head dedicated radio frequency coil of an MR scanner. The PET modules are based on monolithic LYSO crystals coupled by means of optical devices to an array of 256 Silicon Photomultipliers. These types of crystals allow to preserve the scintillation light distribution and, thus, to recover the exact photon impact position with the proper characterization of such a distribution. Every module contains 4 Application Specific Integrated Circuits (ASICs) which return detailed information of several light statistical momenta. The preliminary tests carried out on this design and controlled by means of ASICs have shown promising results towards the suitability of hybrid PET–MR systems., This work was supported by the Centre for Industrial Technological Development co-funded by FEDER through the Technology Fund (DREAM Project, IDI-20110718), the Spanish Plan Nacional de Investigacion Cientifica, Desarrollo e Innovacion Tecnologica (I + D + I) under Grant no. FIS2010-21216-CO2-01 and the Valencian Local Government under Grant PROMETEO 2008/114.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Expectation maximization (EM) algorithms using polar symmetriesfor computed tomography(CT) image reconstruction

  • Rodríguez-Álvarez, M.J.|||0000-0001-8333-8792
  • Benlloch Baviera, Jose María|||0000-0001-6073-1436
  • Soriano Asensi, Antonio
  • Iborra Carreres, Amadeo
  • Sánchez Martínez, Filomeno
  • González Martínez, Antonio Javier
  • Conde, P.
  • Hernández Hernández, Liczandro
  • Moliner Martínez, Laura
  • Orero Palomares, Abel
  • Vidal San Sebastián, Luis Fernando
We suggest a symmetric-polar pixellation scheme which makes possible a reduction of the computational cost for expectation maximization (EM) iterative algorithms. The proposed symmetric-polar pixellation allows us to deal with 3D images as a whole problem without dividing the 3D problem into 2D slices approach. Performance evaluation of each approach in terms of stability and image quality is presented. Exhaustive comparisons between all approaches were conducted in a 2D based image reconstruction model. From these 2D approaches, that showing the best performances were finally implemented and evaluated in a 3D based image reconstruction model. Comparison to 3D images reconstructed with FBP is also presented. Although the algorithm is presented in the context of computed tomography (CT) image reconstruction, it can be applied to any other tomographic technique as well, due to the fact that the only requirement is a scanning geometry involving measurements of an object under different projection angles. Real data have been acquired with a small animal (CT) scanner to verify the proposed mathematical description of the CT system., This work was supported by the Spanish Plan Nacional de Investigacion Cientifica, Desarrollo e Innovacion Tecnologica (I+D+I) under Grant, FIS2010-21216-CO2-01, Valencian Local Government under Grant Nos. PROMETEO 2008/114 and APOSTD/2010/012. The authors would like to thank Brennan Holt for checking and correcting the text.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Monolithic crystals for PET devices: optical coupling optimization

  • González Martínez, Antonio Javier
  • Peiró, A.
  • Conde, P.
  • Hernández Hernández, Liczandro
  • Moliner Martínez, Laura
  • Orero Palomares, Abel
  • Rodríguez-Álvarez, M.J.
  • Sánchez Martínez, Filomeno
  • Soriano Asensi, Antonio
  • Vidal San Sebastián, Luis Fernando
  • Benlloch Baviera, Jose María|||0000-0001-6073-1436
[EN] In this work we present a method to efficiently collect scintillation light when using monolithic scintillator crystals. The acceptance angle of the scintillation light has been reduced by means of optical devices reducing the border effect which typically affects continuous crystals. We have applied this procedure on gamma detectors for PET systems using both position sensitive PMTs and arrays of SiPMs. In the case of using SiPMs, this approach also helps to reduce the photosensor active area. We evaluated the method using PMTs with a variety of different crystals with thicknesses ranging from 10 to 24 mm. We found that our design allows the use of crystal blocks with a thickness of up to 18 mm without degrading the spatial resolution caused by edge effects and without a significant detriment to the energy resolution. These results were compared with simulated data. The first results of monolithic LYSO crystals coupled to an array of 256 SiPMs by means of individual optical light guides are also presented., This work was supported by the Centre for Industrial Technological Development co-funded by FEDER through the Technology Fund (DREAM Project, IDI-20110718), the Spanish Plan Nacional de Investigación Científica, Desarrollo e Innovación Tecnológica (I+D +I) under Grant no. FIS2010-21216-CO2-01 and the Valencian Local Government under Grant PROMETEO 2008/114.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Implementation and analysis of list mode algorithm using tubes of response on a dedicated brain and breast PET

  • Moliner Martínez, Laura
  • González Martínez, Antonio Javier
  • Rodríguez-Álvarez, M.J.|||0000-0001-8333-8792
  • F Sánchez
  • Vidal San Sebastian, Luis Fernando|||0000-0001-8852-8560
  • Benlloch Baviera, Jose María|||0000-0001-6073-1436
  • Correcher, Carlos
  • Conde Castellanos, Pablo Eloy
  • Hernández Hernández, Liczandro
  • Orero Palomares, Abel
  • Soriano Asensi, Antonio
In this work we present an innovative algorithm for the reconstruction of PET images based on the List-Mode (LM) technique which improves their spatial resolution compared to results obtained with current MLEM algorithms. This study appears as a part of a large project with the aim of improving diagnosis in early Alzheimer disease stages by means of a newly developed hybrid PET-MR insert. At the present, Alzheimer is the most relevant neurodegenerative disease and the best way to apply an effective treatment is its early diagnosis. The PET device will consist of several monolithic LYSO crystals coupled to SiPM detectors. Monolithic crystals can reduce scanner costs with the advantage to enable implementation of very small virtual pixels in their geometry. This is especially useful for LM reconstruction algorithms, since they do not need a pre-calculated system matrix. We have developed an LM algorithm which has been initially tested with a large aperture (186 mm) breast PET system. Such an algorithm instead of using the common lines of response, incorporates a novel calculation of tubes of response. The new approach improves the volumetric spatial resolution about a factor 2 at the border of the field of view when compared with traditionally used MLEM algorithm. Moreover, it has also shown to decrease the image noise, thus increasing the image quality. © 2012 Elsevier B.V. All rights reserved., This work was supported by the Centre for Industrial Technological Development co-funded by FEDER through the Technology Fund (DREAM Project, IDI-20110718), by the Spanish Plan Nacional de Investigacion Cientifica, Desarrollo e Innovacion Tecnologica (I+D+I) under Grant. No. FIS2010-21216-CO2-01TEO 2008/114.