Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 4
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Application of the Tikhonov unfolding method for reconstruction of primary X-ray spectra from X-ray equipments

  • Querol, A.
  • Gallardo Bermell, Sergio|||0000-0002-3703-9983
  • Ródenas Diago, José|||0000-0003-3283-9188
  • Verdú Martín, Gumersindo Jesús|||0000-0001-5098-080X
This work has been partially supported by the V alencian Region Govermnent under project Grant GVPRE/2008/136, and the Universidad Politécnica de Valencia under project PAID-06-07-3300.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Application of the Monte Carlo codes PENELOPE and MCNP5 to unfold X-ray spectra in the diagnostic energy range

  • Gallardo Bermell, Sergio|||0000-0002-3703-9983
  • Verdú Martín, Gumersindo Jesús|||0000-0001-5098-080X
  • Ródenas Diago, José|||0000-0003-3283-9188
  • Querol Vives, Andrea
  • Pozuelo Navarro, Fausto
Obtaining primary X-ray spectra is a complex task mainly due to the high fluence of X-rays. In order to avoid the pile up effect in the detector, an indirect method based on the Compton scattering interactions in a low density rod material can be successfully applied in the diagnostic energy range. In this work, the Monte Carlo codes PENELOPE and MCNP5 have been used to simulate the indirect method based on a simplified Compton spectrometry technique. Both models include the X-ray focus, a poly(mehtylmethacrylate) (PMMA) rod and an HPGe detector. Because the probability that primary photons scattered in the PMMA will be emitted towards the detector is small, it is necessary to consider appropriate values for cut-offs and other simulation parameters. With these models, a response function can be determined, relating the response of the detector to the primary X-ray spectrum. This function can be normally expressed as a matrix, which can be calculated by simulating the response detector to several monochromatic X-ray beams. The main goal of this work is to test the capability of the Monte Carlo codes PENELOPE and MCNP5 together with unfolding methods to estimate the primary spectrum when the response matrix and the response of the detector for a given conditions are known. The reliability of unfolded X-ray spectra is studied by comparing them with theoretical spectra obtained from the IPEM 78 catalogue and calculating the Root Mean Squared (RMS) and Quality parameters., This work was partially supported by the Grant-in-Aid for Scientific Research of Ministry of Education, Spain. Grant number: AP2009-2600, Project leader: Professor Gumersindo Verdu, Universidad Politecnica de Valencia.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Parametric study of the X-ray primary spectra obtained with the MTSVD unfolding method

  • Querol Vives, Andrea
  • Gallardo Bermell, Sergio|||0000-0002-3703-9983
  • Ródenas Diago, José|||0000-0003-3283-9188
  • Verdú Martín, Gumersindo Jesús|||0000-0001-5098-080X
The Modified Truncated Singular Value Decomposition (MTSVD) unfolding method is applied to obtain primary spectra for X-ray tubes in radiodiagnostic. Three parameters - voltage, anode angle and filter thickness- of the tube are tested. Unfolded spectra are compared with theoretical extracted from IPEM-78 catalogue. A 2σ error criterion is applied to assess the minimum variations in tested parameters that permits distinguishing between close spectra., This work has been partially supported by the Valencian Region Government under project Grant GVPRE/2008/136 and the Universidad Politecnica de Valencia under project PAID 06-07-3300.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Application of the MTSVD unfolding method for reconstruction of primary X-ray spectra using semiconductor detectors

  • Gallardo Bermell, Sergio|||0000-0002-3703-9983
  • Ródenas Diago, José|||0000-0003-3283-9188
  • Verdú Martín, Gumersindo Jesús|||0000-0001-5098-080X
  • Querol Vives, Andrea
[EN] A thorough knowledge of the primary spectrum is very important to perform a quality control (QC) of X-ray tubes. In previous works, a methodology to assess primary spectrum using a Compton spectrometer and applying the Monte Carlo (MC) method has been analyzed. By means of a Monte Carlo model, a response matrix can be built, relating the Pulse Height Distribution (PHD) recorded in the detector to the primary X-ray spectrum. Subsequently, an unfolding method based on the application of a Modified Truncated Singular Value Decomposition (MTSVD) is applied to the response matrix to assess the primary spectrum. Germanium (Ge), Silicon (Si) and Cadmium-Telluride (CdTe) detectors are considered in this work. The main goal of the paper is to determine whether the MTSVD unfolding method is adequate to provide an acceptable reproduction of spectra for these detectors., This work has been partially supported by Valencian Region Government under project Grant GVPRE/2008/136, and Universidad Politécnica de Valencia under project PAID-06-07-3300.