Skip to main content

GESTION EFICIENTE DE LA ENERGIA EN MICRORREDES INDUSTRIALES CON ALTA PENETRACION DE TECNOLOGIA PV

PCIN-2015-001

•
Funding agency name Ministerio de Economía y Competitividad
Funding agency acronym MINECO
Program Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Call Proyectos Programación Conjunta Internacional
Call year 2015
State Plan 2013-2016 Plan Estatal de Investigación Científica y Técnica y de Innovación
Management unit Subdirección General de Proyectos Internacionales
Beneficiary centre UNIVERSITAT POLITECNICA DE CATALUNYA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 14
Encontrada(s) 1 página(s)

UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

Analysis of the effect of clock drifts on frequency regulation and power sharing in inverter-based islanded microgrids

  • Martí Colom, Pau|||0000-0002-5189-0782
  • Torres Martínez, Javier
  • Rosero Chandi, Carlos Xavier
  • Velasco García, Manel|||0000-0002-0764-3063
  • Miret Tomàs, Jaume|||0000-0003-1175-4900
  • Castilla Fernández, Miguel|||0000-0002-3284-860X
© 2018 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes,creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works., Local hardware clocks in physically distributed computation devices hardly ever agree because clocks drift apart and the drift can be different for each device. This paper analyses the effect that local clock drifts have in the parallel operation of voltage source inverters (VSIs) in islanded microgrids (MG). The state-of-the-art control policies for frequency regulation and active power sharing in VSIs-based MGs are reviewed and selected prototype policies are then re-formulated in terms of clock drifts. Next, steady-state properties for these policies are analyzed. For each of the policies, analytical expressions are developed to provide an exact quantification of the impact that drifts have on frequency and active power equilibrium points. In addition, a closed-loop model that accommodates all the policies is derived, and the stability of the equilibrium points is characterized in terms of the clock drifts. Finally, the implementation of the analyzed policies in a laboratory MG provides experimental results that confirm the theoretical analysis., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

Receding-horizon model predictive control for a three-phase VSI with an LCL filter

  • Guzmán Solà, Ramon|||0000-0002-4386-5800
  • García de Vicuña Muñoz de la Nava, José Luis|||0000-0003-2947-849X
  • Camacho Santiago, Antonio|||0000-0002-0673-6452
  • Miret Tomàs, Jaume|||0000-0003-1175-4900
  • Rey, Juan M
© 2018 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works., This paper presents a Continuous Control Set Model Predictive Control with receding horizon for a threephase voltage source inverter with LCL filter, using a reduced model of the converter. The main advantages of using this reduced model is that an active damping can be achieved while the computational burden is reduced. Besides, in order to eliminate the model uncertainties, and also to achieve a zero steady state error, the proposed converter model includes an embedded integrator. Regarding the control scheme, a Kalman filter is used in order to estimate the three-phase currents without oscillation. The objective is to find the control signals vector that minimizes the error between the current and its reference. It is important to remark that the control signals obtained fromthe cost function can be used directly in a space vector modulator, without the use of additional controllers such as proportionalintegral or proportional-resonant. Compared with the Finite Control Set Model Predictive Control, the proposedmethod operates at fixed switching frequency without using any restriction in the cost function. Simulation and experimental results show that this proposalworks correctly even in case of grid harmonics and voltage sags., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

Robust and fast sliding-mode control for a DC-DC current-source parallel-resonant converter

  • Moradi Ghahderijani, Mohammad
  • Castilla Fernández, Miguel|||0000-0002-3284-860X
  • Momeneh, Arash
  • Miret Tomàs, Jaume|||0000-0003-1175-4900
  • García de Vicuña Muñoz de la Nava, José Luis|||0000-0003-2947-849X
Modern DC-DC resonant converters are normally built around a voltage-source series-resonant converter. This study aims to facilitate the practical use of current-source parallel-resonant converters due to their outstanding properties. To this end, this study presents a sliding-mode control scheme, which provides the following features to the closed-loop system: (i) high robustness to external disturbances and parameter variations and (ii) fast transient response during large and abrupt load changes. In addition, a design procedure for determining the values of the control parameters is presented. The theoretical contributions of this study are experimentally validated by selected tests on a laboratory prototype., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

Voltage support experimental analysis of a low-voltage ride-through strategy applied to grid-connected distributed inverters

  • Garnica López, Miguel Andrés
  • García de Vicuña Muñoz de la Nava, José Luis|||0000-0003-2947-849X
  • Miret Tomàs, Jaume|||0000-0003-1175-4900
  • Camacho Santiago, Antonio|||0000-0002-0673-6452
  • Guzmán Solà, Ramon|||0000-0002-4386-5800
In recent decades, different control strategies have been designed for the increasing integration of distributed generation systems. These systems, most of them based on renewable energies, use electronic converters to exchange power with the grid. Capabilities such as low-voltage ride-through and reactive current injection have been experimentally explored and reported in many research papers with a single inverter; however, these capabilities have not been examined in depth in a scenario with multiple inverters connected to the grid. Only few simulation works that include certain methods of reactive power control to solve overvoltage issues in low voltage grids can be found in the literature. Therefore, the overall objective of the work presented in this paper is to provide an experimental analysis of a low-voltage ride-through strategy applied to distributed power generation systems to help support the grid during voltage sags. The amount of reactive power will depend on the capability of each inverter and the amount of generated active power. The obtained experimental results demonstrate that, depending on the configuration of distributed generation, diverse inverters could have different control strategies. In the same way, the discussion of these results shows that the present object of study is of great interest for future research., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

Model-based control for a three-phase shunt active power filter

  • Guzmán Solà, Ramon|||0000-0002-4386-5800
  • García de Vicuña Muñoz de la Nava, José Luis|||0000-0003-2947-849X
  • Morales López, Javier|||0000-0002-3629-3787
  • Castilla Fernández, Miguel|||0000-0002-3284-860X
  • Miret Tomàs, Jaume|||0000-0003-1175-4900
This paper presents a robust model-based control in natural frame for a three-phase shunt active power filter. For the proposed control method a linear converter model is deduced. Then, this model is used in a Kalman filter in order to estimate the system state-space variables. Even though the states estimation do not match the variables of the real system, it has allowed to design three sliding mode controllers providing the following features to the closed loop system: a) robustness due to the fact that control specifications are met independently of any variation in the system parameters; b) noise immunity, since a Kalman filter is applied; c) a lower THD of the current delivered by the grid compared with the standard solution using measured variables; d) the fundamental component of the voltage at point of common coupling is estimated even in the case of a distorted grid; and e) a reduction in the number of sensors. Thanks to this solution the sliding surfaces for each controller are independent. This decoupling property of the three controllers allows using a fixed switching frequency algorithm that ensures a perfect current control. Finally, experimental results validate the propos
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

Performance evaluation of secondary control policies with respect to digital communications properties in inverter-based islanded microgrids

  • Martí Colom, Pau|||0000-0002-5189-0782
  • Velasco García, Manel|||0000-0002-0764-3063
  • Martín Rull, Enric Xavier|||0000-0002-6775-5470
  • García de Vicuña Muñoz de la Nava, José Luis|||0000-0003-2947-849X
  • Miret Tomàs, Jaume|||0000-0003-1175-4900
  • Castilla Fernández, Miguel|||0000-0002-3284-860X
A key challenge for inverted-based microgrids working in islanded mode is to maintain their own frequency and voltage to a certain reference values while regulating the active and reactive power among distributed generators and loads. The implementation of frequency and voltage restoration control policies often requires the use of a digital communication network for real-time data exchange (tertiary control covers the coordi- nated operation of the microgrid and the host grid). Whenever a digital network is placed within the loop, the operation of the secondary control may be affected by the inherent properties of the communication technology. This paper analyses the effect that properties like transmission intervals and message dropouts have for four existing representative approaches to secondary control in a scalable islanded microgrid. The simulated results reveals pros and cons for each approach, and identifies threats that properly avoided or handled in advance can prevent failures that otherwise would occur. Selected experimental results on a low- scale laboratory microgrid corroborate the conclusions extracted from the simulation study., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

Control strategy for grid-connected three-phase inverters during voltage sags to meet grid codes and to maximize power delivery capability

  • Garnica López, Miguel Andrés
  • García de Vicuña Muñoz de la Nava, José Luis|||0000-0003-2947-849X
  • Miret Tomàs, Jaume|||0000-0003-1175-4900
  • Castilla Fernández, Miguel|||0000-0002-3284-860X
  • Guzmán Solà, Ramon|||0000-0002-4386-5800
Inverter-based distributed generation plays a vital role in the stability and reliability of new power systems. Under voltage sags, these systems must remain connected to the electrical network according to the stringent requirements of grid codes. Low-voltage ride-through control strategies are becoming a common trend in power electronics research. However, previous studies of these control strategies have not dealt with the different possible scenarios presented by new grid codes, and many of them focus on a very limited number of control objectives. In this study, an algorithm to maximize the converter capabilities was developed and subjected to experimental tests during different voltage sags. In this research, based on unbalanced voltage drops of several severity levels, six different cases of current injection are identified while taking into consideration the restrictions imposed by grid codes. The research results represent a further step towards the development of flexible controllers adaptable to the environments of intelligent electricity grids with high integration of distributed generation., Peer Reviewed
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Performance evaluation of secondary control policies with respect to digital communications properties in inverter-based islanded microgrids

  • Martí Colom, Pau
  • Velasco García, Manel
  • Martín Rull, Enric Xavier
  • García de Vicuña Muñoz de la Nava, José Luis
  • Miret Tomàs, Jaume
  • Castilla Fernández, Miguel
A key challenge for inverted-based microgrids working in islanded mode is to maintain their own frequency and voltage to a certain reference values while regulating the active and reactive power among distributed generators and loads. The implementation of frequency and voltage restoration control policies often requires the use of a digital communication network for real-time data exchange (tertiary control covers the coordi- nated operation of the microgrid and the host grid). Whenever a digital network is placed within the loop, the operation of the secondary control may be affected by the inherent properties of the communication technology. This paper analyses the effect that properties like transmission intervals and message dropouts have for four existing representative approaches to secondary control in a scalable islanded microgrid. The simulated results reveals pros and cons for each approach, and identifies threats that properly avoided or handled in advance can prevent failures that otherwise would occur. Selected experimental results on a low- scale laboratory microgrid corroborate the conclusions extracted from the simulation study., Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Analysis of the effect of clock drifts on frequency regulation and power sharing in inverter-based islanded microgrids

  • Martí Colom, Pau
  • Torres Martínez, Javier
  • Rosero Chandi, Carlos Xavier
  • Velasco García, Manel
  • Miret Tomàs, Jaume
  • Castilla Fernández, Miguel
© 2018 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes,creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works., Local hardware clocks in physically distributed computation devices hardly ever agree because clocks drift apart and the drift can be different for each device. This paper analyses the effect that local clock drifts have in the parallel operation of voltage source inverters (VSIs) in islanded microgrids (MG). The state-of-the-art control policies for frequency regulation and active power sharing in VSIs-based MGs are reviewed and selected prototype policies are then re-formulated in terms of clock drifts. Next, steady-state properties for these policies are analyzed. For each of the policies, analytical expressions are developed to provide an exact quantification of the impact that drifts have on frequency and active power equilibrium points. In addition, a closed-loop model that accommodates all the policies is derived, and the stability of the equilibrium points is characterized in terms of the clock drifts. Finally, the implementation of the analyzed policies in a laboratory MG provides experimental results that confirm the theoretical analysis., Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Voltage support experimental analysis of a low-voltage ride-through strategy applied to grid-connected distributed inverters

  • Garnica López, Miguel Andrés
  • García de Vicuña Muñoz de la Nava, José Luis
  • Miret Tomàs, Jaume
  • Camacho Santiago, Antonio
  • Guzmán Solà, Ramon
In recent decades, different control strategies have been designed for the increasing integration of distributed generation systems. These systems, most of them based on renewable energies, use electronic converters to exchange power with the grid. Capabilities such as low-voltage ride-through and reactive current injection have been experimentally explored and reported in many research papers with a single inverter; however, these capabilities have not been examined in depth in a scenario with multiple inverters connected to the grid. Only few simulation works that include certain methods of reactive power control to solve overvoltage issues in low voltage grids can be found in the literature. Therefore, the overall objective of the work presented in this paper is to provide an experimental analysis of a low-voltage ride-through strategy applied to distributed power generation systems to help support the grid during voltage sags. The amount of reactive power will depend on the capability of each inverter and the amount of generated active power. The obtained experimental results demonstrate that, depending on the configuration of distributed generation, diverse inverters could have different control strategies. In the same way, the discussion of these results shows that the present object of study is of great interest for future research., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Receding-horizon model predictive control for a three-phase VSI with an LCL filter

  • Guzmán Solà, Ramon
  • García de Vicuña Muñoz de la Nava, José Luis
  • Camacho Santiago, Antonio
  • Miret Tomàs, Jaume
  • Rey, Juan M
© 2018 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works., This paper presents a Continuous Control Set Model Predictive Control with receding horizon for a threephase voltage source inverter with LCL filter, using a reduced model of the converter. The main advantages of using this reduced model is that an active damping can be achieved while the computational burden is reduced. Besides, in order to eliminate the model uncertainties, and also to achieve a zero steady state error, the proposed converter model includes an embedded integrator. Regarding the control scheme, a Kalman filter is used in order to estimate the three-phase currents without oscillation. The objective is to find the control signals vector that minimizes the error between the current and its reference. It is important to remark that the control signals obtained fromthe cost function can be used directly in a space vector modulator, without the use of additional controllers such as proportionalintegral or proportional-resonant. Compared with the Finite Control Set Model Predictive Control, the proposedmethod operates at fixed switching frequency without using any restriction in the cost function. Simulation and experimental results show that this proposalworks correctly even in case of grid harmonics and voltage sags., Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Robust and fast sliding-mode control for a DC-DC current-source parallel-resonant converter

  • Moradi Ghahderijani, Mohammad
  • Castilla Fernández, Miguel
  • Momeneh, Arash
  • Miret Tomàs, Jaume
  • García de Vicuña Muñoz de la Nava, José Luis
Modern DC-DC resonant converters are normally built around a voltage-source series-resonant converter. This study aims to facilitate the practical use of current-source parallel-resonant converters due to their outstanding properties. To this end, this study presents a sliding-mode control scheme, which provides the following features to the closed-loop system: (i) high robustness to external disturbances and parameter variations and (ii) fast transient response during large and abrupt load changes. In addition, a design procedure for determining the values of the control parameters is presented. The theoretical contributions of this study are experimentally validated by selected tests on a laboratory prototype., Peer Reviewed, Preprint
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Model-based control for a three-phase shunt active power filter

  • Guzmán Solà, Ramon
  • García de Vicuña Muñoz de la Nava, José Luis
  • Morales López, Javier
  • Castilla Fernández, Miguel
  • Miret Tomàs, Jaume
This paper presents a robust model-based control in natural frame for a three-phase shunt active power filter. For the proposed control method a linear converter model is deduced. Then, this model is used in a Kalman filter in order to estimate the system state-space variables. Even though the states estimation do not match the variables of the real system, it has allowed to design three sliding mode controllers providing the following features to the closed loop system: a) robustness due to the fact that control specifications are met independently of any variation in the system parameters; b) noise immunity, since a Kalman filter is applied; c) a lower THD of the current delivered by the grid compared with the standard solution using measured variables; d) the fundamental component of the voltage at point of common coupling is estimated even in the case of a distorted grid; and e) a reduction in the number of sensors. Thanks to this solution the sliding surfaces for each controller are independent. This decoupling property of the three controllers allows using a fixed switching frequency algorithm that ensures a perfect current control. Finally, experimental results validate the propos, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Control strategy for grid-connected three-phase inverters during voltage sags to meet grid codes and to maximize power delivery capability

  • Garnica López, Miguel Andrés
  • García de Vicuña Muñoz de la Nava, José Luis
  • Miret Tomàs, Jaume
  • Castilla Fernández, Miguel
  • Guzmán Solà, Ramon
Inverter-based distributed generation plays a vital role in the stability and reliability of new power systems. Under voltage sags, these systems must remain connected to the electrical network according to the stringent requirements of grid codes. Low-voltage ride-through control strategies are becoming a common trend in power electronics research. However, previous studies of these control strategies have not dealt with the different possible scenarios presented by new grid codes, and many of them focus on a very limited number of control objectives. In this study, an algorithm to maximize the converter capabilities was developed and subjected to experimental tests during different voltage sags. In this research, based on unbalanced voltage drops of several severity levels, six different cases of current injection are identified while taking into consideration the restrictions imposed by grid codes. The research results represent a further step towards the development of flexible controllers adaptable to the environments of intelligent electricity grids with high integration of distributed generation., Peer Reviewed, Postprint (published version)