Mixed Reality Guidance Improves Acetabular Component Positioning Accuracy During Simulated Total Hip Arthroplasty: A Prospective Pilot Study

  • Hernandez-Balada, Javier
  • Mifsut, Damian
  • Valverde-Navarro, Alfonso Amador
  • Juan, M. Carmen|||0000-0002-8764-1470
[EN] Background: Accurate acetabular component positioning is critical to the success of total hip arthroplasty (THA). Mixed reality (MR)-based simulation offers a novel approach to surgical training by providing real-time feedback within immersive learning environments. This study evaluated the impact of an MR-based simulation on technical performance, as well as its usability and user experience. Methods: A prospective pre-post pilot educational study was conducted in a controlled simulation laboratory using a physical anatomical model. Forty-six final-year medical students with no prior experience in MR technology participated. Participants performed acetabular component positioning tasks before and after MR-assisted training. Technical accuracy was assessed by measuring deviations in inclination and anteversion. Usability, workload, presence, and cybersickness were evaluated using validated questionnaires. Results: MR-assisted training significantly improved technical accuracy. Median absolute deviation in inclination decreased from 1.0 degrees (interquartile range [IQR], 1.0-3.5) to 0.5 degrees (IQR, 0.0-2.0) (p = 0.0008, r = 0.56), while anteversion deviation decreased from 4.5 degrees (IQR, 2.0-7.0) to 2.0 degrees (IQR, 1.0-4.0) (p < 0.0001, r = 0.66). User experience scores ranked the application among top-performing systems in benchmark comparisons. Participants reported high levels of presence and usability, low workload (all NASA-TLX domains <36/100), and minimal cybersickness (mean Simulator Sickness Questionnaire score = 0.26). Conclusions: MR-assisted simulation significantly improved short-term technical performance in novice trainees and was associated with high user acceptance and minimal adverse effects. These findings support the use of MR as a promising adjunct in early surgical training, enabling integration of cognitive and psychomotor skills through real-time feedback. Further studies are warranted to evaluate skill retention and transfer to clinical practice., This research was funded by the FISABIO (Fundacio per al Foment de la Investigacio Sanitaria i Biomedica de la Comunitat Valenciana) POLISABIO 2023-PI2 RMArthro.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

A mixed reality application for total hip arthroplasty

  • Juan, M. Carmen|||0000-0002-8764-1470
  • Hidalgo, Cora
  • Mifsut, Damián
[EN] Total hip arthroplasty (or total hip replacement) is the current surgical solution for the treatment of advanced coxarthrosis, with the objective of providing mobility and pain relief to patients. For this purpose, surgery can be planned using preoperative images acquired from the patient and navigation systems can also be used during the intervention. Robots have also been used to assist in interventions. In this work, we propose a new mixed reality application for total hip arthroplasty. The surgeon only has to wear HoloLens 2. The application does not require acquiring preoperative or intraoperative images of the patient and uses hand interaction. Interaction is natural and intuitive. The application helps the surgeon place a virtual acetabular cup onto the patient's acetabulum as well as define its diameter. Similarly, a guide for drilling and implant placement is defined, establishing the abduction and anteversion angles. The surgeon has a direct view of the operating field at all times. For validation, the values of the abduction and anteversion angles offered by the application in 20 acetabular cup placements have been compared with real values (ground-truth). From the results, the mean (standard deviation) is 0.375 (0.483) degrees for the error in the anteversion angle and 0.1 (0.308) degrees for the abduction angle, with maximum discrepancies of 1 degree. A study was also carried out on a cadaver, in which a surgeon verified that the application is suitable to be transferred to routine clinical practice, helping in the guidance process for the implantation of a total hip prosthesis., Open Access funding provided thanks to the CRUE-CSIC agreement with Springer Nature. Open Access funding provided thanks to the CRUE Universitat Politècnica de València agreement with Springer Nature.