Skip to main content

NUEVAS TOPOLOGIAS DE CONVERSION, CONFIGURACIONES Y ESTRATEGIAS DE CONTROL PARA LA FUTURA RED ELECTRICA BASADA EN ENERGIAS RENOVABLES

PID2019-110956RB-I00

•
Funding agency name Agencia Estatal de Investigación
Funding agency acronym AEI
Program Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Call Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Call year 2019
State Plan 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Beneficiary centre UNIVERSIDAD PUBLICA DE NAVARRA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 17
Encontrada(s) 1 página(s)

Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publication Artículo científico (JournalArticle)

Control design and stability analysis of power converters: the discrete generalized Bode criterion

  • Urtasun Erburu, Andoni
  • Samanes Pascual, Javier
  • Barrios Rípodas, Ernesto
  • Sanchis Gúrpide, Pablo
For the controller design and stability analysis of power electronic converters, the Bode stability criterion and its subsequent revisions are the most practical tools. However, even though the control of the power converter is usually implemented in a microprocessor, none of these methods is infallible when applied to a discrete system. This article therefore proposes a new stability criterion, named the Discrete Generalized Bode Criterion (DGBC). This method is based on the Nyquist criterion but developed from the open-loop Bode diagram, evaluated also at 0 Hz and at the Nyquist frequency. The proposed criterion combines the advantages of the Nyquist and Bode criteria, since it is always applicable and provides an interesting and useful tool for the controller design process. The method is applied to design an active damping control of an inverter with LCL filter, showing how the proposed criterion accurately predicts stability, in contrast to the existing Bode criteria. The theoretical analysis is validated through experimental results performed with a three-phase inverter and an LCL filter., This work was supported in part by the Agencia Estatal de Investigación (AEI) under Grant PID2019-110956RB-I00/AEI/10.13039/501100011033, and in part by the Ingeteam Power Technology.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publication Artículo científico (JournalArticle)

Power angle-frequency droop control to enhance transient stability of grid-forming inverters under voltage dips

  • Erdocia Zabala, Ioseba
  • Urtasun Erburu, Andoni
  • Marroyo Palomo, Luis
Due to the replacement of synchronous generators, grid operators are currently demanding to control grid-connected inverters in grid–forming mode to make them participate in the maintenance of the grid. To carry this out, the traditional droop controls based on the active and reactive powers are usually adopted, achieving a satisfactory performance in normal operation. Nevertheless, the power-frequency (P-ω) droop may become transiently unstable under voltage dips. This is because of the modification of the active power response caused by the inverter current limitation together with the voltage reduction. To enhance this, the power angle-frequency (δinv-ω) droop is proposed, consisting in employing an estimation of the inverter power angle as input to obtain the inverter frequency. The proposed method provides the inverter with the same performance as the P-ω droop in normal operation, while enhancing considerably the transient stability margins under current limitation. This is thanks to the higher variation of the inverter power angle with the phase difference between the inverter and the grid. Simulation results show the transient stability problems of the P-ω droop as well as the superior performance of the proposed δinv-ω droop control, which has also been verified by means of HIL results., This work has been supported by the Spanish State Research Agency (AEI) under grant PID2019-110956RB-I00 /AEI/ 10.13039/501100011033, and by the Public University of Navarre through a doctoral scholarship.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publication Artículo científico (JournalArticle)

Deadbeat voltage control for a grid-forming power converter with LCL filter

  • Samanes Pascual, Javier
  • Rosado Galparsoro, Leyre
  • Gubía Villabona, Eugenio
  • López Taberna, Jesús
  • Pérez, Marcelo A.
Grid-forming power converters are controlled as voltage sources to regulate the grid voltage and frequency. These converters can increase power system strength if they impose a voltage waveform resilient to grid transients. For this reason, in this paper, we propose a deadbeat control strategy of the capacitor voltage for high power converters with LCL filter. To damp the LCL resonant poles, an active damping strategy is developed, based on a modification of the deadbeat control law. With this purpose, a notch filter is applied to the electrical variables allowing to emulate different damping resistances for the fundamental component and the harmonics. As a result, the active damping does not introduce tracking errors of the fundamental frequency component, while it provides damping to the filter resonance. The proposed strategy does not require knowledge of the grid impedance, an interesting feature in grid-connected power converters because the grid impedance is generally unknown. Experimental results validate the proposed strategy., This work was supported in part by Spanish State Research Agency (AEI) under Grants PID2019-110956RB-I00 /AEI/ 10.13039 and TED2021-132604B-I00, in part by the Spanish Ministry of Universities through “Programa Estatal de Promoción del Talento y su Empleabilidad en I+D+i, Subprograma Estatal de Movilidad, del Plan Estatal de Investigación Científica y Técnica y de Innovación 2017-2020” Program, in part by the Advanced Center for Electrical and Electronics Engineering (AC3E) under Grant ANID/FB0008, in part by Solar Energy Research Center (SERC) under Grant ANID/FONDAP/15110019, and in part by the ANID/Fondecyt under Regular Grant 1211826.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publication Artículo científico (JournalArticle)

Robust active damping strategy for DFIG wind turbines

  • Rosado Galparsoro, Leyre
  • Samanes Pascual, Javier
  • Gubía Villabona, Eugenio
  • López Taberna, Jesús
Doubly fed induction generators (DFIGs) with an LCL filter are widely used for wind power generation. In these energy conversion systems, there is an interaction between the grid-side converter (GSC) and the rotor-side converter (RSC) control loops, the generator and the LCL filter that must be properly modeled. Such interaction between the GSC and the RSC proves to have a significant influence on the stability. Several active damping (AD) methods for grid-connected converters with an LCL filter have been proposed, nevertheless, the application of these techniques to a DFIG wind turbine is not straightforward, as revealed in this article. To achieve a robust damping irrespective of the grid inductance, this article proposes an AD strategy based on the capacitor current feedback and the adjustment of the control delays to emulate a virtual impedance, in parallel with the filter capacitor, with a dominant resistive component in the range of possible resonance frequencies. This work also proves that, by applying the AD strategy in both converters simultaneously, the damping of the system resonant poles is maximized when a specific value of the grid inductance is considered. Experimental results show the interaction between the GSC and the RSC and validate the proposed AD strategy. © 1986-2012 IEEE., This work was supported by the Spanish State Research Agency (AEI) under Grant PID2019-110956RB-I00/AEI/10.13039.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publication Artículo científico (JournalArticle)

Winding resistance measurement in power inductors - understanding the impact of the winding mutual resistance

  • Barrios Rípodas, Ernesto
  • Elizondo Martínez, David
  • Ursúa Rubio, Alfredo
  • Sanchis Gúrpide, Pablo
Inductors are cornerstone components in power electronics converters. Since winding loss is the dominant loss mechanism in these components, its accurate measurement is fundamental for the validation of the inductor's operation and design. The techniques for the winding resistance R_{w} measurement in power inductors can be classified into two groups, indirect and direct. Both techniques use coupled inductors to separate winding and core power losses. If coupled inductors with non-zero winding mutual resistances R_{w,m} are used, invalid results are obtained with these techniques. Understanding the meaning of R_{w,m} in coupled inductors is complex. In this paper, the impact of R_{w,m} on the inductor R_{w} measurement techniques is demonstrated and practical guidelines for the design of the zero R_{w,m} coupled inductors are given. Particularly, the location of the auxiliary winding for the direct technique is investigated. In order to compare the R_{w} measurement techniques and to validate the coupled inductor's R_{w,m} impact, two different inductors are built and tested. The results are compared with the values for R_{w} calculated by FEA simulation. It is found that only the direct technique with an auxiliary winding carefully designed and located following the guidelines given in this paper makes the accurate measurement of R_{w} in power inductors possible., This work was supported in part by the Spanish State Research Agency (AEI) and the FEDER-UE under Grant PID2019-110956RB-I00/AEI/10.13039/501100011033, and in part by the Ingeteam Power Technology.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publication Artículo científico (JournalArticle)

Zero-loss switching in LLC resonant converters under discontinuous conduction mode: analysis and design methodology

  • Elizondo Martínez, David
  • Barrios Rípodas, Ernesto
  • Larequi, Íñigo
  • Ursúa Rubio, Alfredo
  • Sanchis Gúrpide, Pablo
Many thriving applications where isolation is required, such as LED drivers, traction and EV fast charging, implement LLC resonant converters, particularly when voltage regulation is not required or an additional conversion stage is in charge of it. The LLC converter can be operated under discontinuous conduction mode (DCM), due to its advantages such as unregulated and sensorless operation, fixed switching frequency and voltage gain, and zero-current switching (ZCS). However, ZCS results in EMI and switching losses in the primary converter, particularly for≥1200-V devices. Alternatively, zero-loss switching (ZLS) can be accomplished by means of a proper design of the LLC converter, overcoming the drawbacks of ZCS. The focus of this paper is to perform an exhaustive research on the LLC converter under DCM-ZLS: discontinuous conduction mode with lossless switching in the primary and secondary sides. As a result of this analysis, a set of design boundaries are deduced for parameters such as the magnetizing inductance, the leakage inductance, and the gate resistance. A comprehensive, step-by-step design methodology is proposed and applied to a 18-kW, 200-kHz test bench. The designed parameters are implemented in the converter and several experiments are conducted, including a test at rated input voltage and rated power (600 V, 18 kW). The conduction states studied theoretically in the analysis of the LLC converter are identified in the experimental results, and the operation of the test bench under DCM-ZLS is verified., This work was supported by the Public University of Navarra under Grant PID2019- 110956RB-I00, funded by MCIN/AEI/10.13039/501100011033/, and in part by the under a PhD Scholarship.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publication Artículo científico (JournalArticle)

Medium-voltage cascaded sequential topology for large-scale PV plants

  • Lumbreras Magallón, David
  • Barrios Rípodas, Ernesto
  • Balda Belzunegui, Julián
  • Navarrete, Manuel
  • González Senosiain, Roberto
  • Sanchis Gúrpide, Pablo
Photovoltaic (PV) conversion systems are in continuous development due to their increasingly competitive prices. The traditional configuration of large-scale PV plants is based on high-power central inverters, which have reduced their cost by increasing their power rating. However, this cost reduction is expected to saturate in the near future, mainly due to an increase in the cost of the dc wiring. Cascaded conversion systems have appeared as potential solutions to continue reducing the PV plant cost. They consist of several conversion units whose ac outputs are connected in series. This enables the power-rating reduction of each individual conversion unit, while maintaining the power rating of the conversion structure. Thus, the conversion units are placed closer to the PV panels, reducing the dc wiring cost. In this paper, a novel three-phase topology for medium-voltage cascaded conversion systems is presented. The proposed topology is formed of several conversion units, each one with a reduced number of conversion stages, namely, dc/ac, medium-frequency isolation and ac/ac. Moreover, thanks to its sequential operation and modulation technique, zero-voltage switching and zero-current switching are achieved in all conversion stages. In this way, with respect to the configuration with central inverters, the proposed topology has the advantages of cascaded conversion systems. In comparison to previously investigated cascaded topologies, the proposed topology also presents promising characteristics, representing a potential cost reduction and efficiency increase. An experimental validation of the topology is carried out in a laboratory prototype consisting of three conversion units., This work was supported in part by the Spanish State Research Agency (AEI) under Grant PID2019-110956RB-I00 /AEI/10.13039/501100011033, and in part by the Public University of Navarre through a Ph.D. Scholarship.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publication Artículo científico (JournalArticle)

Modeling of a droop-controlled grid-connected DFIG wind turbine

  • Oraa Iribarren, Iker
  • Samanes Pascual, Javier
  • López Taberna, Jesús
  • Gubía Villabona, Eugenio
Traditionally, to characterize the response of droop-controlled systems RMS models have been used. However, as it is demonstrated in this work, when droop control is applied to doubly-fed induction generators, RMS models do not allow to predict the system stability and dynamic response. Thus, in this article, a linearized small-signal model that overcomes the limitations of RMS models is presented. The proposed model is validated by simulation in MATLAB/Simulink demonstrating that it allows to accurately analyze the stability and dynamic response of the system under study. This model is an interesting tool that can be used in future works to design and adjust grid-forming controllers for doubly-fed induction generators., This work was supported by the Spanish State Research Agency (AEI) under Grant PID2019-110956RB-I00/AEI/10.13039.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publication Artículo científico (JournalArticle)

Analytical modeling of high-frequency winding loss in round-wire toroidal inductors

  • Elizondo Martínez, David
  • Barrios Rípodas, Ernesto
  • Ursúa Rubio, Alfredo
  • Sanchis Gúrpide, Pablo
Toroidal inductors are used in many industrial applications in which they are key components regarding cost and volume. In the inductor design process, it is paramount to accurately estimate its high-frequency winding loss. Finite-element analysis (FEA) software and analytical models can be used for this purpose. However, the former employs too much time and the latter lacks accuracy when applied to toroidal windings, leading to an overestimation that can exceed 200%. As a consequence, designers would benefit from a reliable method to calculate high-frequency loss in toroidal windings. This article proposes an analytical model that considers the 2-D characteristic of the magnetic field and the geometrical particularities of toroidal windings. Furthermore, it provides an easy-to-use method, which avoids the unaffordable computational cost of FEA software. Simulations and experimental measurements are carried out for seven toroidal power inductors, from 10 Hz up to 200 kHz. Three different well-known state-of-the-art analytical models are used for comparison purposes. The results obtained with the proposed model are in good agreement with those from FEA and the experiments. The proposed model shows a maximum deviation below 20% while the overestimation of the existing analytical methods reaches values from 93% to 226%., This work is part of the project PID2019-110956RB-I00, funded by MCIN/AEI/10.13039/501100011033/, and has also been supported by the Public University of Navarra (UPNA) under a Ph.D. scholarship.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publication Artículo científico (JournalArticle)

Enhancement of the voltage control response in three-phase photovoltaic inverters with small dc capacitors

  • Urtasun Erburu, Andoni
  • Sanchis Gúrpide, Pablo
  • Marroyo Palomo, Luis
In the case of photovoltaic (PV) inverters, an adequate dc voltage regulation is fundamental to maximize or limit the power injected into the grid. However, the traditional control requires a large dc capacitance to ensure stability in the whole operating range while the existing alternatives, despite achieving a stable control with a small capacitance, become too slow in the open-circuit area. This paper proposes two control methods to improve this performance. Firstly, a new voltage control with virtual impedance emulation is presented, showing that the response becomes faster in all operating points. Secondly, the control with impedance emulation is combined with a feed-forward compensation, further improving the dynamic response. Both methods are very simple to implement and their superior performance when using a small dc capacitance is verified by means of simulation results., This work was supported by the Spanish State Research Agency (AEI) under grant PID2019-110956RB-I00/AEI/10.13039.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publication Artículo científico (JournalArticle)

Dual voltage-current control to provide grid-forming inverters with current limiting capability

  • Erdocia Zabala, Ioseba
  • Urtasun Erburu, Andoni
  • Marroyo Palomo, Luis
The rapid uptake of renewable energy sources is causing synchronous generators (SG) to be replaced by power electronic inverters meaning these inverters need to offer the characteristics traditionally associated with SG. As a result, it has been proposed that the inverters should be controlled in grid-forming mode in order to support the voltage of the microgrids. Given that these inverters are controlled as a voltage source, temporary events such as short-circuits or overloads could cause currents that are far higher than the rated current. As the semiconductors used in power electronics are highly sensitive to overcurrents, this paper proposes a dual voltage-current control that provides the grid-forming inverters with the capability to quickly limit the current under any overload or short-circuit condition. The proposed method has been validated through experimental tests in stand-alone mode., This work hasbeen supported by theSpanish State Research Agency (AEI) under grantPID2019-110956RB-I00/AEI/10.13039/501100011033, and by the Public University of Navarre through a doctoral scholarship.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publication Artículo científico (JournalArticle)

Inclusion of a supercapacitor energy storage system in DFIG and full-converter PMSG wind turbines for inertia emulation

  • Berrueta Irigoyen, Alberto
  • Sacristán Sillero, Javier
  • López Taberna, Jesús
  • Rodríguez Izal, José Luis
  • Ursúa Rubio, Alfredo
  • Sanchis Gúrpide, Pablo
The energy transition towards renewables must be accelerated to achieve climate targets. To do so, renewable power plants, such as wind power plants (WPPs) must replace conventional power plants (CPPs). Transmission System Operators require this replacement to be made without weakening the frequency response of power systems, so it must be ensured that WPPs match the response of CPPs to grid frequency variations. CPPs consist of grid-tied synchronous generators that inherently react to frequency variations by modifying their stored kinetic energy and their output power, thereby contributing to grid stability. Such response is known as inertial response. By contrast, wind turbines (WTs) are mostly based on either doubly-fed induction generators (DFIG) or permanent magnet synchronous generators (PMSG). Their power electronics interface decouples the electromechanical behavior of the generator from the power grid, leading to a negligible inertial response. Therefore, in order to replace CPPs with WPPs, WTs must be able to react to frequency variations by changing their output power, i.e., emulating an inertial response. Currently implemented inertia emulation strategies in WTs rely on pitch control and stored kinetic energy variation. This paper proposes an alternative strategy, using the energy stored in a supercapacitor directly connected to the back-to-back converter DC link to emulate inertia. Its performance is validated by means of simulation for both DFIG and PMSG. Compared to state-of-the-art techniques, it allows a more accurate emulation of grid-tied synchronous generators, favoring the replacement of these generators by WTs., This work was supported in part by Siemens Gamesa Renewable Energy, in part by the Spanish State Research Agency, AEI/10.13039/501100011033 under Grants PID2019- 111262RB-I00 and PID2019-110956RB-I00, and in part by the Government of Navarre under Grant 0011-1411-2022-000049 through EnVeNA Project.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publication Artículo científico (JournalArticle)

Novel two-stage three-level converter with inherently-balanced dc voltage for EV fast-charging applications

  • Elizondo Martínez, David
  • Barrios Rípodas, Ernesto
  • Galdeano Bujanda, Mikel
  • Ursúa Rubio, Alfredo
  • Sanchis Gúrpide, Pablo
The design of EV fast chargers faces a new challenge due to the boost in the battery voltage of electric cars and heavyduty electric vehicles. Two-stage converters, that consist of an isolated dc-dc stage and an extra regulated dc-dc converter, are attracting an increasing attention thanks to their outstanding performance. The potential benefits of multilevel converters, such as lower power losses and more compact filters, can be incorporated to two-stage architectures at the expense of simplicity due to the need of a voltage balancing method. In this article, a novel dc-dc two-stage three-level (2S3L) architecture is presented, which guarantees that the multilevel input dc voltages are balanced without any specific balancing technique or extra components. Moreover, it accomplishes lossless switching in the isolated dc-dc stage, enabling a high efficiency. A 15 kW test bench is built in order to experimentally verify the inherentlybalanced voltages. The experimental tests demonstrate that the dc-link voltages are inherently-balanced (no control needed) in both transient and steady states, and that it is robust against tolerances and faulty operation. The test bench is able to provide a wide output voltage, from 200 to 900 V, and reaches a high peak efficiency of 98.2% at rated power., This work is part of the projects PID2019-110956RB-I00 and TED2021-132604B-I00, funded by MCIN/AEI/10.13039/501100011033 and by the European Union NextGenerationEU/PRTR. It was also been supported by the Public University of Navarre (UPNA) under a postdoctoral scholarship.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publication Artículo científico (JournalArticle)

Conductance-frequency droop control to ensure transient stability of inverter-based stand-alone microgrids

  • Erdocia Zabala, Ioseba
  • Urtasun Erburu, Andoni
  • Marroyo Palomo, Luis
Currently, inverter-based stand-alone microgrids are gaining interest due to the advantages of obtaining energy from renewable sources. To manage the operation, these microgrids include storage systems connected in par- allel to the PCC through electronic inverters that are controlled as voltage sources in order to support the fre- quency and voltage at the PCC. For the purpose of ensuring P and Q sharing among inverters and also the synchronization stability of the microgrid, droop control is widely used, achieving a satisfactory performance in normal operation. Nevertheless, in the presence of overloads or short-circuits, the inverters must limit the current for self-protection, thereby modifying the performance of the system that then becomes prone to suffer transient stability problems. In this paper, first the performance of the inverter-based stand-alone microgrids with the conventional P-f and Iact-f droops is analyzed, obtaining the stability boundaries during current limitation. In order to always ensure the synchronization stability of the system, this paper then proposes the G-f droop that consists in employing the equivalent conductance seen by each inverter for its frequency droop control. Furthermore, as this variable always correctly represents the inverter power angle, the system dynamics are not affected by the operating conditions. The theoretical results have been validated by means of simulation and Hardware-In-the-Loop results, showing the superior performance of the proposed G-f droop, This work has been supported by the Spanish State Research Agency (AEI) under grant PID2019-110956RB-I00/AEI/ 10.13039/501100011033, and by the Public University of Navarre through a PhD scholarship. Open access funding provided by Public University of Navarre.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publication Artículo científico (JournalArticle)

Selective harmonic mitigation: limitations of classical control strategies and benefits of model predictive control

  • Rosado Galparsoro, Leyre
  • Samanes Pascual, Javier
  • Gubía Villabona, Eugenio
  • López Taberna, Jesús
Selective harmonic mitigation pulsewidth modulation (SHMPWM) combined with model predictive control (MPC) is a promising approach for grid-connected power converters. SHMPWM can guarantee grid code compliance in steady state, e.g. grid harmonic injection, with a reduced output converter filter, while MPC improves dynamic response and allows grid code compliance in the event of grid transients. This paper presents a survey of the MPC strategies already published in the literature developed for their use with SHMPWM. The existing strategies fall into two categories: direct model predictive control with an implicit selective harmonic mitigation modulator, and direct model predictive control based on finite control set (FCS-MPC). One representative control strategy of each group is compared to each other and to the performance of classical proportional- integral (PI) controllers combined with SHMPWM. The goal is to identify the potential benefits of MPC for grid-connected power converters, and determine the main advantages and limitations of the two selected state-of-the-art control strategies. Their performance is assessed through Hardware-in-the-Loop (HIL) experimental results in terms of real-time implementation, harmonic content grid code compliance, dynamic response and performance under grid transients., This work is part of the projects PID2019-110956RB-I00 and TED2021- 132604B-I00, funded by MCIN/AEI/10.13039/501100011033 and by the European Union NextGenerationEU/PRTR. It has also been partially supported by Ingeteam Power Technology and the Public University of Navarre.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publication Artículo científico (JournalArticle)

Sub-synchronous resonance damping control strategy for DFIG wind turbines

  • Samanes Pascual, Javier
  • Gubía Villabona, Eugenio
  • López Taberna, Jesús
  • Burgos, Rolando
Doubly-fed induction generator (DFIG) wind turbines connected to capacitive series-compensated transmission lines are prone to exhibit oscillatory behavior. The phenomena is called sub-synchronous resonances (SSRs), as these oscillations occur at frequencies below the fundamental component. This paper first develops a modeling methodology for DFIG wind turbines, based on impedance matrices, that is applied to model a real wind farm where SSRs were reported. The stability analysis performed shows how the interaction between the grid-side converter and the rotor-side converter contribute to the instability of DFIG wind energy conversion systems connected to series compensated grids. With this model, we propose a simple sub-synchronous resonance control strategy based on an orthogonal proportional action applied to the rotor currents, and a variable gain in the PI controller adjusted as a function of the DFIG rotational speed. This control strategy depends only on the rotor currents, which are local and already measured variables in any DFIG wind turbine, and is implemented in the rotor side converter, so it does not imply an additional cost at wind farm or wind turbine level and can be applied to any DFIG wind energy conversion system (WECS). Additionally, it proves to be robust for any line impedance series compensation level, and it does not need real-time information concerning the grid at which the wind turbine is connected, or its parameters. A real case study is considered, where the sub-synchronous resonance damping strategy presented in this work is able to stabilize the system for every possible line impedance compensation level., This work was supported by the Agencia Estatal de Investigacion (AEI) (Spanish State Research Agency) under Grant PID2019-110956RB-I00/AEI/10.13039 and Grant DPI-2016-80641-R.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publication Artículo científico (JournalArticle)

Single-loop droop control strategy for a grid-connected DFIG wind turbine

  • Oraa Iribarren, Iker
  • Samanes Pascual, Javier
  • López Taberna, Jesús
  • Gubía Villabona, Eugenio
When grid-forming droop control strategies are implemented in grid-connected power converters, two control strategies are widely used: the single-loop and multiloop droop controls. However, only multiloop droop control strategies with inner control loops have been implemented in doubly fed induction generator (DFIG)-based wind turbines so far. This article proposes the application of a single-loop droop control strategy to a DFIG wind turbine, which has not been previously explored or implemented. As shown in the article, the application of the conventional droop control without inner control loops to DFIG-based wind power systems does not ensure a stable response. After modeling the system dynamics and evaluating its stability, two causes of instability have been identified: a resonance at the rotor electrical frequency relevant at high slips and a phase margin reduction at low slips. To solve these instability issues two control solutions are proposed: the emulation of a virtual resistor and a phase rotation. The proposed control strategy allows stabilizing the system and achieving a fast and damped dynamic response. The effectiveness of the proposed control strategy is validated by experimental results., This work was supported by the Spanish State Research Agency under Grant PID2019-110956RB-I00/AEI/10.13039.