Skip to main content

ANALISIS DE LA PELIGROSIDAD DE INUNDACION CONSIDERANDO VEHICULOS Y OTROS FLOTANTES EN ZONA URBANA

PID2019-110965RB-I00

•
Funding agency name Agencia Estatal de Investigación
Funding agency acronym AEI
Program Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Call Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Call year 2019
State Plan 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Beneficiary centre UNIVERSITAT POLITECNICA DE CATALUNYA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 10
Encontrada(s) 1 página(s)

UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

Flood-related hazard criteria during the human evacuation of underground spaces through stairs: a state-of-the-art review

  • Aparicio Uribe, Carlos Humberto
  • Russo, Beniamino|||0000-0001-9437-0085
  • Tellez Alvarez, Jackson David|||0000-0003-1428-9872
  • Martínez Gomariz, Eduardo|||0000-0002-0189-0725
Due to the increasing urbanisation trend and more recurrent flood events worldwide that are affecting exposed habitable areas like underground spaces. This state-of-the-art review presents a comprehensive analysis of the available literature that focuses on defining instability criteria for hazard assessment during human evacuation of underground flooded stairs. The studies are outlined in three main groups: theoretical, experimental campaigns and numerical approaches. Several methods for defining specific criteria were found, most of these criteria were described as a function of water depth (D) alone or in combination with velocity (V) highlighting the importance of these two water-related parameters for flood-related hazard evaluation. Succinctly, the most relevant findings and limitations of these studies are discussed and summarised in tables. A comparison with other flood-related hazard criteria in plain and mild-slope areas is presented. Finally, potential future investigation lines are proposed. Thus, this state-of-the-art review could offer a comprehensive overview of the topic and stimulate new exploratory studies in this research field yielding valuable insights that can be easily transmitted to stakeholders or non-experts and foster urban resilience during floods., Open Access funding provided thanks to the CRUE-CSIC agreement with Springer Nature. This work was supported by the Spanish national research project PID2019-110965RB-I00 “Analysis of flood hazard considering vehicles and other floating elements”., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

Influence of pedestrian grouping on evacuation efficiency in underground flooded stairs: a 3D numerical assessment

  • Aparicio Uribe, Carlos Humberto
  • Russo, Beniamino|||0000-0001-9437-0085
  • Tellez Alvarez, Jackson David|||0000-0003-1428-9872
  • Martínez Gomariz, Eduardo|||0000-0002-0189-0725
Urban floods increasingly threaten underground spaces and their users. Often essential for evacuation, stairs pose unique challenges as they also serve as the main path for the incoming water. While prior studies typically examine individual behaviour, the role of groups on flooded stairs remains underexplored. This study addresses that gap through a 3D numerical analysis evaluating how different pedestrian arrangements affect evacuation efficiency and safety. Using realistic human body dummies on real-scale stairs under a water discharge of 0.423 m3/s, the analysis calculates hydrodynamic forces alongside Momentum of Flow MF and Specific Force Per Unit Width (SFPUW) M0 to assess hazardous conditions. Scenarios include individuals alone, in tandem, and side-by-side. Results show that group configurations significantly influence water-dragging forces. Side-by-side arrangements increased the force on both neighbouring and downstream pedestrians, while tandem formations reduced drag on trailing individuals. Greater separation distances between individuals reduced force influences. These findings reveal how group positioning affects safety during evacuation and highlight potential bottlenecks. The study offers valuable insights for improving evacuation strategies and safety protocols in underground infrastructure during floods, ultimately contributing to urban resilience and effective flood risk mitigation., This work was sponsored by the Spanish Ministry of Science and Innovation - project FAVOUR: PID2019-110965RB-I00 “Analysis of flood hazard considering vehicles and other floating elements”. Special recognition to the support offered by the FLUMEN laboratory team at the UPC in the construction and operation of the facility, the FLOW-3D technical team for the assistance during the development of the numerical models and Transports Metropolitans de Barcelona (TMB) for providing the information needed to replicate the stairs in the laboratory., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

Preliminary pluvial flood hazard assessment for underground access stairs in Barcelona metropolitan area metro stations

  • Cruz Coronas, Àlex de la
  • Aparicio Uribe, Carlos Humberto
  • Téllez Álvarez, Jackson
  • Martínez Gomariz, Eduardo|||0000-0002-0189-0725
  • Granés Puig, Joan
  • Russo, Beniamino|||0000-0001-9437-0085
Urban underground infrastructures are highly vulnerable to intense rainfall events, particularly access stairs, where preferential runoff paths and the most probable evacuation routes can conflict. This study presents a pluvial flood hazard assessment for underground access stairs in the Barcelona Metropolitan Area Metro network. It integrates the EU ICARIA project modeling framework and the hazard assessment criteria based on hydraulic parameters identified by the Spanish national research project FAVOUR. Both current and future climate change rainfall scenarios are considered. The results showed that out of 415 underground access points, 27 face a high risk of floods, while 35 more have potentially high-risk conditions. These figures could rise to 38 (40% increase) and 47 (74% increase) respectively by the end of the century since climate change is projected to increase rainfall intensity and frequency. By quantifying hazard levels across the network, this study allows the identification of points of the infrastructure where hazard conditions can be more critical. Furthermore, the results presented could potentially support targeted adaptation strategies such as entrance retrofitting, improved drainage design, and emergency planning to develop resilient and sustainable cities. The proposed methodology demonstrates how ICARIA’s modeling framework can effectively evaluate and anticipate flood hazards in complex urban environments at the asset level., This publication has been supported by The ICARIA project (Improving Climate Resilience of Critical Assets) funded by the European Commission through the Horizon Europe Program, grant number 101093806 (https://cordis.europa.eu/project/id/101093806 (accessed on 1 February 2026)) and the program “Pla de Doctorats Industrials” (Generalitat de Catalunya) provided by the Agència de Gestió d’Ajuts Universitaris i de Recerca (https://agaur.gencat.cat/en/ (accessed on 1 February 2026)) through the Industrial Doctorate Plan of the Secretariat for Universities and Research Department of Business and Knowledge of the Government of Catalonia, under the Grant DI 0030-2023. On the other hand, this work integrates and findings from the FAVOUR project (Flood hazard analysis considering vehicles and other floating elements) funded by the Spanish Ministry of Science and Innovation under project PID2019-110965RB-I00., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

Influence of pedestrian grouping on evacuation efficiency in underground flooded stairs: a 3D numerical assessment

  • Aparicio Uribe, Carlos Humberto
  • Russo, Beniamino|||0000-0001-9437-0085
  • Tellez Alvarez, Jackson David|||0000-0003-1428-9872
  • Martínez Gomariz, Eduardo|||0000-0002-0189-0725
Urban floods increasingly threaten underground spaces and their users. Often essential for evacuation, stairs pose unique challenges as they also serve as the main path for the incoming water. While prior studies typically examine individual behaviour, the role of groups on flooded stairs remains underexplored. This study addresses that gap through a 3D numerical analysis evaluating how different pedestrian arrangements affect evacuation efficiency and safety. Using realistic human body dummies on real-scale stairs under a water discharge of 0.423 m3/s, the analysis calculates hydrodynamic forces alongside Momentum of Flow MF and Specific Force Per Unit Width (SFPUW) M0 to assess hazardous conditions. Scenarios include individuals alone, in tandem, and side-byside. Results show that group configurations significantly influence water-dragging forces. Side-by-side arrangements increased the force on both neighbouring and downstream pedestrians, while tandem formations reduced drag on trailing individuals. Greater separation distances between individuals reduced force influences. These findings reveal how group positioning affects safety during evacuation and highlight potential bottlenecks. The study offers valuable insights for improving evacuation strategies and safety protocols in underground infrastructure during floods, ultimately contributing to urban resilience and effective flood risk mitigation., This work was sponsored by the Spanish Ministry of Science and Innovation - project FAVOUR: PID2019-110965RB-I00 “Analysis of flood hazard considering vehicles and other floating elements”. Special recognition to the support offered by the FLUMEN laboratory team at the UPC in the construction and operation of the facility, the FLOW-3D technical team for the assistance during the development of the numerical models and Transports Metropolitans de Barcelona (TMB) for providing the information needed to replicate the stairs in the laboratory., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

Hydraulic modelling and pedestrian hazard assessment on underground access stairs: The paral·lel metro station case study in Barcelona

  • Aparicio Uribe, Carlos Humberto
  • Russo, Beniamino|||0000-0001-9437-0085
  • Téllez Álvarez, Jackson
  • Martínez Gomariz, Eduardo|||0000-0002-0189-0725
Given the increasing flooding incidents in metro stations globally, underground space infrastructures must guarantee users' safety. This manuscript characterises the hydraulic behaviour of a flood-prone access stairs of the Paral·lel Metro station in Barcelona. Using a real-scale stairs model at the Technical University of Catalonia (UPC) and the Computational Fluid Dynamics (CFD) software FLOW-3D. Hydraulic parameters; water velocity, and depth were analysed under different discharges. Human instability criteria, Momentum of Flow (MF) and Specific Force Per Unit Width ‘SFPUW’ (M0) indicated that the most hazardous zone was the lower part of the stairs. Sectorised analyses showed that specific locations like the walls and proximities to risers presented lower safety criteria values compared to the centre of the stairs and steps' borders. Also, the numerical model closely mirrored the aerated flow experimentally observed. These findings provide useful information for future research campaigns aiming to improve urban resilience to face underground evacuation of flooded stairs., This work was sponsored by the Spanish Ministry of Science and Innovation—project PID2019-110965RB-I00 ‘Analysis of flood hazard considering vehicles and other floating elements’. Special recognition to the support offered by the FLUMEN laboratory team at the UPC in the construction and operation of the facility, theFLOW-3D technical team for the assistance during the development of the numerical models, and Transports Metropolitans de Barcelona (TMB) for providing the information needed to replicate the stairs in the laboratory. This work was supported by the Spanish Ministry of Science, Innovation and Universities (PID2019-110965RB-I00)., Peer Reviewed
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Influence of pedestrian grouping on evacuation efficiency in underground flooded stairs: a 3D numerical assessment

  • Aparicio Uribe, Carlos Humberto
  • Russo, Beniamino
  • Tellez Alvarez, Jackson David
  • Martínez Gomariz, Eduardo
Urban floods increasingly threaten underground spaces and their users. Often essential for evacuation, stairs pose unique challenges as they also serve as the main path for the incoming water. While prior studies typically examine individual behaviour, the role of groups on flooded stairs remains underexplored. This study addresses that gap through a 3D numerical analysis evaluating how different pedestrian arrangements affect evacuation efficiency and safety. Using realistic human body dummies on real-scale stairs under a water discharge of 0.423 m3/s, the analysis calculates hydrodynamic forces alongside Momentum of Flow MF and Specific Force Per Unit Width (SFPUW) M0 to assess hazardous conditions. Scenarios include individuals alone, in tandem, and side-byside. Results show that group configurations significantly influence water-dragging forces. Side-by-side arrangements increased the force on both neighbouring and downstream pedestrians, while tandem formations reduced drag on trailing individuals. Greater separation distances between individuals reduced force influences. These findings reveal how group positioning affects safety during evacuation and highlight potential bottlenecks. The study offers valuable insights for improving evacuation strategies and safety protocols in underground infrastructure during floods, ultimately contributing to urban resilience and effective flood risk mitigation., This work was sponsored by the Spanish Ministry of Science and Innovation - project FAVOUR: PID2019-110965RB-I00 “Analysis of flood hazard considering vehicles and other floating elements”. Special recognition to the support offered by the FLUMEN laboratory team at the UPC in the construction and operation of the facility, the FLOW-3D technical team for the assistance during the development of the numerical models and Transports Metropolitans de Barcelona (TMB) for providing the information needed to replicate the stairs in the laboratory., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Preliminary pluvial flood hazard assessment for underground access stairs in Barcelona metropolitan area metro stations

  • Cruz Coronas, Àlex de la
  • Aparicio Uribe, Carlos Humberto
  • Téllez Álvarez, Jackson
  • Martínez Gomariz, Eduardo
  • Granés Puig, Joan
  • Russo, Beniamino
Urban underground infrastructures are highly vulnerable to intense rainfall events, particularly access stairs, where preferential runoff paths and the most probable evacuation routes can conflict. This study presents a pluvial flood hazard assessment for underground access stairs in the Barcelona Metropolitan Area Metro network. It integrates the EU ICARIA project modeling framework and the hazard assessment criteria based on hydraulic parameters identified by the Spanish national research project FAVOUR. Both current and future climate change rainfall scenarios are considered. The results showed that out of 415 underground access points, 27 face a high risk of floods, while 35 more have potentially high-risk conditions. These figures could rise to 38 (40% increase) and 47 (74% increase) respectively by the end of the century since climate change is projected to increase rainfall intensity and frequency. By quantifying hazard levels across the network, this study allows the identification of points of the infrastructure where hazard conditions can be more critical. Furthermore, the results presented could potentially support targeted adaptation strategies such as entrance retrofitting, improved drainage design, and emergency planning to develop resilient and sustainable cities. The proposed methodology demonstrates how ICARIA’s modeling framework can effectively evaluate and anticipate flood hazards in complex urban environments at the asset level., This publication has been supported by The ICARIA project (Improving Climate Resilience of Critical Assets) funded by the European Commission through the Horizon Europe Program, grant number 101093806 (https://cordis.europa.eu/project/id/101093806 (accessed on 1 February 2026)) and the program “Pla de Doctorats Industrials” (Generalitat de Catalunya) provided by the Agència de Gestió d’Ajuts Universitaris i de Recerca (https://agaur.gencat.cat/en/ (accessed on 1 February 2026)) through the Industrial Doctorate Plan of the Secretariat for Universities and Research Department of Business and Knowledge of the Government of Catalonia, under the Grant DI 0030-2023. On the other hand, this work integrates and findings from the FAVOUR project (Flood hazard analysis considering vehicles and other floating elements) funded by the Spanish Ministry of Science and Innovation under project PID2019-110965RB-I00., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Hydraulic modelling and pedestrian hazard assessment on underground access stairs: The paral·lel metro station case study in Barcelona

  • Aparicio Uribe, Carlos Humberto
  • Russo, Beniamino
  • Téllez Álvarez, Jackson
  • Martínez Gomariz, Eduardo
Given the increasing flooding incidents in metro stations globally, underground space infrastructures must guarantee users' safety. This manuscript characterises the hydraulic behaviour of a flood-prone access stairs of the Paral·lel Metro station in Barcelona. Using a real-scale stairs model at the Technical University of Catalonia (UPC) and the Computational Fluid Dynamics (CFD) software FLOW-3D. Hydraulic parameters; water velocity, and depth were analysed under different discharges. Human instability criteria, Momentum of Flow (MF) and Specific Force Per Unit Width ‘SFPUW’ (M0) indicated that the most hazardous zone was the lower part of the stairs. Sectorised analyses showed that specific locations like the walls and proximities to risers presented lower safety criteria values compared to the centre of the stairs and steps' borders. Also, the numerical model closely mirrored the aerated flow experimentally observed. These findings provide useful information for future research campaigns aiming to improve urban resilience to face underground evacuation of flooded stairs., This work was sponsored by the Spanish Ministry of Science and Innovation—project PID2019-110965RB-I00 ‘Analysis of flood hazard considering vehicles and other floating elements’. Special recognition to the support offered by the FLUMEN laboratory team at the UPC in the construction and operation of the facility, theFLOW-3D technical team for the assistance during the development of the numerical models, and Transports Metropolitans de Barcelona (TMB) for providing the information needed to replicate the stairs in the laboratory. This work was supported by the Spanish Ministry of Science, Innovation and Universities (PID2019-110965RB-I00)., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Influence of pedestrian grouping on evacuation efficiency in underground flooded stairs: a 3D numerical assessment

  • Aparicio Uribe, Carlos Humberto
  • Russo, Beniamino
  • Tellez Alvarez, Jackson David
  • Martínez Gomariz, Eduardo
Urban floods increasingly threaten underground spaces and their users. Often essential for evacuation, stairs pose unique challenges as they also serve as the main path for the incoming water. While prior studies typically examine individual behaviour, the role of groups on flooded stairs remains underexplored. This study addresses that gap through a 3D numerical analysis evaluating how different pedestrian arrangements affect evacuation efficiency and safety. Using realistic human body dummies on real-scale stairs under a water discharge of 0.423 m3/s, the analysis calculates hydrodynamic forces alongside Momentum of Flow MF and Specific Force Per Unit Width (SFPUW) M0 to assess hazardous conditions. Scenarios include individuals alone, in tandem, and side-by-side. Results show that group configurations significantly influence water-dragging forces. Side-by-side arrangements increased the force on both neighbouring and downstream pedestrians, while tandem formations reduced drag on trailing individuals. Greater separation distances between individuals reduced force influences. These findings reveal how group positioning affects safety during evacuation and highlight potential bottlenecks. The study offers valuable insights for improving evacuation strategies and safety protocols in underground infrastructure during floods, ultimately contributing to urban resilience and effective flood risk mitigation., This work was sponsored by the Spanish Ministry of Science and Innovation - project FAVOUR: PID2019-110965RB-I00 “Analysis of flood hazard considering vehicles and other floating elements”. Special recognition to the support offered by the FLUMEN laboratory team at the UPC in the construction and operation of the facility, the FLOW-3D technical team for the assistance during the development of the numerical models and Transports Metropolitans de Barcelona (TMB) for providing the information needed to replicate the stairs in the laboratory., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Flood-related hazard criteria during the human evacuation of underground spaces through stairs: a state-of-the-art review

  • Aparicio Uribe, Carlos Humberto
  • Russo, Beniamino
  • Tellez Alvarez, Jackson David
  • Martínez Gomariz, Eduardo
Due to the increasing urbanisation trend and more recurrent flood events worldwide that are affecting exposed habitable areas like underground spaces. This state-of-the-art review presents a comprehensive analysis of the available literature that focuses on defining instability criteria for hazard assessment during human evacuation of underground flooded stairs. The studies are outlined in three main groups: theoretical, experimental campaigns and numerical approaches. Several methods for defining specific criteria were found, most of these criteria were described as a function of water depth (D) alone or in combination with velocity (V) highlighting the importance of these two water-related parameters for flood-related hazard evaluation. Succinctly, the most relevant findings and limitations of these studies are discussed and summarised in tables. A comparison with other flood-related hazard criteria in plain and mild-slope areas is presented. Finally, potential future investigation lines are proposed. Thus, this state-of-the-art review could offer a comprehensive overview of the topic and stimulate new exploratory studies in this research field yielding valuable insights that can be easily transmitted to stakeholders or non-experts and foster urban resilience during floods., Open Access funding provided thanks to the CRUE-CSIC agreement with Springer Nature. This work was supported by the Spanish national research project PID2019-110965RB-I00 “Analysis of flood hazard considering vehicles and other floating elements”., Peer Reviewed, Postprint (published version)