Skip to main content

NUEVOS AVANCES EN (MICRO)EXTRACCION ECOLOGICA: DISOLVENTES EUTECTICOS PROFUNDOS MAGNETICOS

PID2021-126155OB-I00

•
Funding agency name Agencia Estatal de Investigación
Funding agency acronym AEI
Program Programa Estatal para Impulsar la Investigación Científico-Técnica y su Transferencia
Subprogram Subprograma Estatal de Generación de Conocimiento
Call Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Call year 2021
State Plan 2021-2023 Plan Estatal de Investigación Científica y Técnica y de Innovación
Beneficiary centre UNIVERSIDAD DE ALICANTE

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Characterization of diluted mixtures of an ionic liquid in a hydrophobic natural deep eutectic solvent: Physicochemical, spectroscopic and electrochemical insights for its application in electrochemically controlled micro-extraction of heavy metals

  • Marco, Andrea
  • Aguirre, Miguel Angel
  • Hidalgo, Montserrat
  • Quijada, César|||0000-0002-9965-9651
[EN] In this work, a hydrophobic natural deep eutectic solvent (NADES) was made by mixing up DL-menthol and decanoic acid in a 2:1 molar ratio, and its mixtures with a soluble ionic liquid (1-hexyl-3-methylimidazolium chloride, [HMIM][Cl]) were investigated. A number of physicochemical properties (ionic conductivity, viscosity, and density) were either measured or estimated by the predictive UNIFAC model over a range of temperatures and [HMIM][Cl] compositions. The addition of [HMIM][Cl] enhances ionic conductivity, while keeping high fluidity and low density. However, Walden plots and dissociation degrees suggest that significant ion pairing occurs. The analysis of excess molar volumes and viscosity deviations suggests that the introduction of the IL up to 50 wt% gives rise to liquid structure with reorganization of the NADES hydrogen-bonding network. Such structural perturbation was confirmed by FT-IR measurements. The more diluted NADES + [HMIM][Cl] system showed an electrochemical stability window of about 2.5 V. Additionally, ferrocene/ferrocenium exhibits a quasi-reversible electron transfer with a standard rate of (2.6 ± 0.3)10¿4 cm s¿1 and a diffusion coefficient of (6.16 ± 0.06)·10¿8 cm2 s¿1. To assess the viability of this medium in analytical applications, an electrochemically controlled liquid-liquid microextraction was conducted, employing the NADES+[HMIM][Cl] mixture as the extractant phase. This approach resulted in a notable enhancement (up to 8-fold gain vs the liquid-liquid microextraction in the absence of electric field) in the metal extraction efficiency from aqueous samples, underscoring the potential of the studied medium in both electrochemical and analytical applications., The authors are grateful for the financial support received from the Valencian Regional Government (Spain) (CIPROM/2021/062) and the Spanish Ministry of Science and Innovation PID2021-126155OB-I00). Authors also wish to thank the Spanish Network of Excellence in Sample Preparation (RED2022-134079-T), which was granted by the Spanish Ministry of Science and Innovation, and the Sample Preparation Study Group and Network, which were sponsored by the European Chemical Society s Division of Analytical Chemistry. Funding for open access charges from CRUE-Universitat Politecnica de Valencia is gratefully acknowledged.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Electrochemically controlled liquid-liquid microextraction: an innovative methodology for heavy metal extraction from tea using non-toxic menthol-based eutectic mixture

  • Marco, Andrea
  • Aguirre, Miguel Ángel
  • Hidalgo, Montserrat
  • Quijada, César|||0000-0002-9965-9651
[EN] Background A growing concern about toxic metal contamination in food has generated a need for efficient, sustainable, and non-toxic sample preparation techniques. Conventional extraction methodologies frequently entail the utilization of hazardous solvents or exhibit a lack of sensitivity. There is an increasing demand for analytical methodologies that are more environmentally friendly and capable of extracting trace metals from complex matrices, such as tea. This study aims to address the need for an efficient and environmentally friendly method for the extraction of metals from tea samples using a combination of electrochemically assisted microextraction and a eutectic mixture as extractant. Results An innovative electrochemically enhanced liquid-liquid microextraction technique has been developed, employing a green eutectic mixture composed of a menthol-based hydrophobic deep eutectic solvent (menthol:decanoic acid, 2:1) and a non-toxic ionic liquid (1-hexyl-3-methylimidazolium chloride) to enhance conductivity. The experimental conditions for the extraction procedure were optimized through the implementation of a design of experiments approach. In the context of optimal conditions (i.e., 10 g sample, 315 ¿L extractant, 5 min extraction, pH 4.66, 1 wt% 8-hydroxyquinoline, 600 rpm shaking and a single ¿0.75 V pulse vs. Ag), the method demonstrated excellent linearity, repeatability, and low limits of detection: 0.2, 0.2, 0.7, 2.8 and 0.5 ¿g kg¿1 for Cd, Cr, Ni, Pb and Zn, respectively. The recovery of real and certified tea samples approached 100 %, with negligible matrix effects. Furthermore, no analytes exceeded the maximum permissible limits established by legislation in the infused samples under study. Significance The proposed method represents a substantial advance in sustainable analytical chemistry, as it facilitates the efficient extraction of metals from tea without the use of toxic solvents. Its performance and environmental compatibility position it as a solid alternative for routine metal analysis in food safety monitoring., The authors are grateful for the financial support received from the Valencia Regional Government (Spain) (CIPROM/2021/062) and the Spanish Ministry of Science and Innovation (PID2021-126155OB-I00) . Authors also wish to thank the Spanish Network of Excellence in Sample Preparation (RED2022-134079-T) , which was granted by the Spanish Ministry of Science and Innovation, and the Sample Preparation Study Group and Network, which were sponsored by the European Chemical Society's Division of Analytical Chemistry.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Sensitive elemental analysis of edible oil samples using a hydrophilic eutectic mixture as green solvent in electrochemically controlled liquid-liquid microextraction

  • Marco, Andrea
  • Pertusa, Borja
  • Aguirre, Miguel Angel
  • Hidalgo, Montserrat
  • Quijada, César|||0000-0002-9965-9651
[EN] Background: Analyzing toxic metals in edible oils is crucial due to the associated health risks and strict regulatory limits. Traditional extraction methods are often time-consuming and require toxic solvents. Additionally, they are sometimes ineffective in complex oil matrices. Therefore, there is a strong demand for sustainable, efficient methodologies for extracting trace metals from oils. This study presents a green, effective approach to metal extraction from various edible oils using electrochemically enhanced microextraction. Results: We present a new, environmentally friendly, electrochemically enhanced liquid-liquid microextraction (EC-LLME) method that uses a choline chloride-based deep eutectic solvent (CC:EG, 1:2) to extract Cd, Cu, Fe, Ni, and Pb from various oil samples. We optimized the extraction parameters using a two-step experimental design. Under the optimal conditions of a 15 g sample, 315 ¿L of extractant, a 10 min extraction time, and a ¿ 0.75 V vs Ag pulse, the method achieved excellent linearity in the range of 5¿500 ¿g kg¿ 1 , high repeatability (CV ¿ 6 %), and low detection limits: 0.16 ¿g kg¿ 1 (Cd and Fe), 0.09 ¿g kg¿ 1 (Cu), 0.4 ¿g kg¿ 1 (Ni), and 1.5 ¿g kg¿ 1 (Pb). No analyte exceeded legal limits in the three samples studied (i.e., refined rapeseed oil, refined sunflower oil, and virgin olive oil), and recoveries in real and certified samples were nearly 100 %, confirming minimal matrix effects. Significance: The EC-LLME method is a novel, sustainable alternative for extracting and quantifying trace metals in edible oils. Its superb analytical capabilities and eco-friendly safety, achieved by steering clear of noxious solvents, make it a suitable option for the identification of trace metals in edible vegetable oil samples., The authors are grateful for the financial support received from the Valencia Regional Government (Spain) (CIPROM/2021/062) and the Spanish Ministry of Science and Innovation (PID2021-126155OB-I00). Authors also wish to thank the Spanish Network of Excellence in Sample Preparation (RED2022-134079-T), which was granted by the Spanish Ministry of Science and Innovation, and the Sample Preparation Study Group and Network, which were sponsored by the European Chemical Society s Division of Analytical Chemistry.