Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 4
Encontrada(s) 1 página(s)

Minerva. Repositorio Institucional de la Universidad de Santiago de Compostela
Publication Artículo científico (JournalArticle)

Photosensitive control and network synchronization of chemical oscillators

  • Carballosa Calleja, Alejandro
  • Gómez Varela, Ana Isabel
  • Bao Varela, María del Carmen
  • Flores Arias, María Teresa
  • Pérez Muñuzuri, Alberto
The Belousov-Zhabotinsky (BZ) reaction has long been a paradigmatic system for studying chemical oscillations. Here, we experimentally studied the synchronization control within photochemically coupled star networks of BZ oscillators. Experiments were carried out in wells performed in soda-lime glass constructed using novel laser technologies. Utilizing the inherent oscillatory nature of the BZ reaction, we engineered a star network of oscillators interconnected through photochemical inhibitory coupling. Furthermore, the experimental setup presented here could be extrapolated to more complex network architectures with both excitatory and inhibitory couplings, contributing to the fundamental understanding of synchronization in complex systems.
Minerva. Repositorio Institucional de la Universidad de Santiago de Compostela
Publication Artículo científico (JournalArticle)

Biocompatibility testing of UV-curable polydimethylsiloxane for human umbilical vein endothelial cell culture on-a-chip

  • Gómez Varela, Ana Isabel
  • Viña, Antonio
  • Bao Varela, María del Carmen
  • Flores Arias, María Teresa
  • Carnero Groba, Bastián
  • González Peteiro, María Mercedes
  • González Juanatey, José Ramón
  • Álvarez Castro, Ezequiel
Polydimethylsiloxane (PDMS) is extensively used to fabricate biocompatible microfluidic systems due to its favorable properties for cell culture. Recently, ultraviolet-curable PDMS (UV-PDMS) has shown potential for enhancing manufacturing processes and final optical quality while retaining the benefits of traditional thermally cured PDMS. This study investigates the biocompatibility of UV-PDMS under static and flow conditions using human umbilical vein endothelial cells (HUVECs). UV-PDMS samples were treated with oxygen plasma and boiling deionized water to assess potential improvements in cell behavior compared with untreated samples. We evaluated HUVECs adhesion, growth, morphology, and viability in static cultures and microchannels fabricated with UV-PDMS to test their resistance to flow conditions. Our results confirmed the biocompatibility of UV-PDMS for HUVECs culture. Moreover, plasma-oxygen-treated UV-PDMS substrates exhibited superior cell growth and adhesion compared to untreated UV-PDMS. This enhancement enabled HUVECs to maintain their morphology and viability under flow conditions in UV-PDMS microchannels. Additionally, UV-PDMS demonstrated improved optical quality and more efficient handling and processing, characterized by shorter curing times and simplified procedures utilizing UV light compared to traditional PDMS.
Minerva. Repositorio Institucional de la Universidad de Santiago de Compostela
Publication Artículo científico (JournalArticle)

Systematic standardization of organ-on-a-chip under controlled flow conditions: Use case with Caki-1 and A549 cell lines

  • Balsa Díaz, Andrea
  • Vázquez Vázquez, Laura
  • Ferreiro Vila, Elías
  • Rivas Meizoso, Lois
  • Martínez Rodríguez, Antón Leandro
  • Brea Floriani, José Manuel
  • Loza García, María Isabel
  • Pérez Rodríguez, Santiago
  • Sinde Stompel, Esteban
  • Álvarez Castro, Ezequiel
  • Rodiño Janeiro, Bruno K.
New in vitro models are urgently needed to improve the preclinical development of new drugs. Current standardised cellular models are mainly based on 2D cell culture, which lacks physiological flow conditions and often involves limited or simplified co-culture settings. • Organ-on-a-chip (OoC) systems use microchips incorporating extracellular matrices, surface coatings and cell cultures to mimic physiological conditions, enabling the formation of 3D structures, co-culture systems and dynamic flow. However, to perform reproducible and controlled experiments using OoC systems, it is necessary to systematically standardise cell culture conditions within the microfluidic channels. • The selection of the extracellular matrix (ECM) coating of the chip must be tailored and optimised for each specific cell type used in OoC systems. It is essential to establish the appropriate biological microenvironment following cell adhesion to the chip, including the time required for cell adhesion and maturation, as well as the appropriate flow conditions. • This protocol standardises flow and ECM coating conditions in OoC with kidney (Caki-1) and lung (A549) cell lines, facilitating reproducible experiments and enabling broader application across different OoC models
RUC. Repositorio da Universidade da Coruña
Publication Artículo científico (JournalArticle)

Polymer Coating Adhesion Drives Functional and Biological Outcomes in Meniscus Implants

  • Blanco, Alfonso F.
  • Rubio Prego, Inés
  • Bao-Varela, Carmen
  • Bouza, Rebeca
  • Núñez Bernal, Paulina
  • Levato, Riccardo
  • Malda, Jos
  • Kon, Elizaveta
  • Crecente-Campo, José
  • Alonso, M. J.
[Abstract]: Achieving stable integration of drug-releasing polymer coatings with load-bearing meniscus implants remains a challenge in biomaterials engineering. In this study, four surface modification strategies, femtosecond-pulsed laser treatment, oxygen plasma, polydopamine, and an ethyl-2-cyanoacrylate (ECA) interlayer, were evaluated for the integration of a dexamethasone (DEX)- and celecoxib (CLX)-releasing bilayer coating with a polycarbonate urethane (PCU) meniscus implant. The selected construct comprised an ECA interlayer applied from a 40% (w/v) solution, a CLX-loaded PLLA/PCL layer prepared at 100 mg/mL and a 53/47 (w/w) polymer ratio with 16.6% CLX loading, and an outer DEX-loaded PLGA layer prepared at 200 mg/mL with 2.44% DEX loading. At 37 °C, compared with uncoated PCU, ECA-containing constructs showed significantly higher storage modulus, loss modulus, and elastic modulus (p < 0.05), while tan δ remained unchanged, indicating preservation of the elastic-dominant viscoelastic response of the complete construct. The ECA-containing coating was subsequently adapted to the geometry of a sheep meniscus implant using an optimized dip-coating procedure. During a 21-day bioreactor study, repeated compression and shear increased cumulative DEX release from 59 to 67% and CLX release from 25 to 40% relative to static controls, while no visible coating delamination was observed. Ethylene oxide sterilization preserved drug loading and release behavior. In an exploratory threemonth sheep study, the fiber-fixed coated implants remained in position, and the coating remained macroscopically associated with the retrieved prostheses. These findings support the use of an ECA interlayer to integrate a bilayer drug-releasing coating with a PCU meniscus implant while preserving construct-level mechanical behavior and drug release under the conditions evaluated., This project has received funding from the European Union’s Horizon 2020 research and innovation program under Grant Agreement No. 814444 (MEFISTO). Alfonso F. Blanco has received research support through a predoctoral grant from Xunta de Galicia, Grant No. ED481A 2022/066. Inés RubioPrego acknowledges a grant (IFI23/00035) from Instituto de Salud Carlos III “Contratos i-PFIS: Doctorados IIS-empresa en Ciencias y Tecnologías de la Salud”. Carmen Bao-Varela acknowledges financial support under grant PID2022- 138322OB-100 funded by MCIN/ AEI/ 10.13039/ 501100011033 and by “ERDF A way of making Europe” and the support of Xunta under grant ED431B 2023/07. The graphical artwork was created by the authors. BioRender (www.biorender.com) was used as a graphical design tool for the figures indicated in the corresponding captions., Xunta de Galicia; ED481A 2022/066, Xunta de Galicia; ED431B 2023/07