Ambient-temperature and fire performance of steel-timber composite beams with demountable shear connectors
[EN] In the construction sector, current trans-national policies promote actions aimed to obtain environmental benefits throughout the whole life cycle of buildings, such as the use of more sustainable materials or the reduction
of waste generation. In this context, the use of timber emerges as a technically viable alternative to replace other
structural materials with a significantly higher embodied carbon and associated greenhouse gas emissions. When
combined with steel in composite flooring systems, benefits at both structural and environmental level can be
found. In the case of steel-timber composite (STC) beams, recent technological developments are intended to
contribute to the transition toward a circular economy model in construction, for instance by facilitating the
disassembly of the different parts by means of the use of demountable connection systems. Nevertheless, current
knowledge on the mechanical performance of STC beams incorporating demountable shear connectors remains
limited, both under service conditions and in accidental scenarios such as fire exposure. In the present work, an
experimental research is presented, in which demountable STC beams were subjected to flexural loading at room
temperature and under standard fire conditions until failure. The STC beams consisted of cross-laminated timber
(CLT) slabs connected to a steel beam by means of two different types of demountable bolted shear connection
systems. According to the results of this investigation, it is shown that this novel structural system performs
appropriately under both loading scenarios. At room temperature, the STC beams showed high ductility and a
significant load bearing capacity. In the fire situation, owing to the ad-hoc passive fire protection system proposed in this investigation, a fire resistance rating of about 120 min was achieved without losing the partial
composite action between the timber slab and the steel beam. The outcomes of this work open new opportunities
in fostering material efficient and environmentally friendly solutions of fire-resistant structural members., The authors gratefully acknowledge the Spanish Agencia Estatal de
Investigacion for the help provided through the grants TED2021-
130580B-I00 and PID2024-161153OB-I00 along with the first author s
pre-doctoral contract PREP2024-002384, funded by MICIU/AEI/
10.13039/501100011033 and by the European Union NextGenerationEU/PRTR, FEDER and FSE+ funds. The authors are also very
grateful to the Association for the Promotion of Research and Technology of Fire Safety (AFITI) for the facilities used to conduct the tests.
Similarly, the authors would like to thank Prof. Christoph Odenbreit
from the University of Luxembourg for providing guidance during the
development of this research project.