Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 17
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Characterization of diluted mixtures of an ionic liquid in a hydrophobic natural deep eutectic solvent: Physicochemical, spectroscopic and electrochemical insights for its application in electrochemically controlled micro-extraction of heavy metals

  • Marco, Andrea
  • Aguirre, Miguel Angel
  • Hidalgo, Montserrat
  • Quijada, César|||0000-0002-9965-9651
[EN] In this work, a hydrophobic natural deep eutectic solvent (NADES) was made by mixing up DL-menthol and decanoic acid in a 2:1 molar ratio, and its mixtures with a soluble ionic liquid (1-hexyl-3-methylimidazolium chloride, [HMIM][Cl]) were investigated. A number of physicochemical properties (ionic conductivity, viscosity, and density) were either measured or estimated by the predictive UNIFAC model over a range of temperatures and [HMIM][Cl] compositions. The addition of [HMIM][Cl] enhances ionic conductivity, while keeping high fluidity and low density. However, Walden plots and dissociation degrees suggest that significant ion pairing occurs. The analysis of excess molar volumes and viscosity deviations suggests that the introduction of the IL up to 50 wt% gives rise to liquid structure with reorganization of the NADES hydrogen-bonding network. Such structural perturbation was confirmed by FT-IR measurements. The more diluted NADES + [HMIM][Cl] system showed an electrochemical stability window of about 2.5 V. Additionally, ferrocene/ferrocenium exhibits a quasi-reversible electron transfer with a standard rate of (2.6 ± 0.3)10¿4 cm s¿1 and a diffusion coefficient of (6.16 ± 0.06)·10¿8 cm2 s¿1. To assess the viability of this medium in analytical applications, an electrochemically controlled liquid-liquid microextraction was conducted, employing the NADES+[HMIM][Cl] mixture as the extractant phase. This approach resulted in a notable enhancement (up to 8-fold gain vs the liquid-liquid microextraction in the absence of electric field) in the metal extraction efficiency from aqueous samples, underscoring the potential of the studied medium in both electrochemical and analytical applications., The authors are grateful for the financial support received from the Valencian Regional Government (Spain) (CIPROM/2021/062) and the Spanish Ministry of Science and Innovation PID2021-126155OB-I00). Authors also wish to thank the Spanish Network of Excellence in Sample Preparation (RED2022-134079-T), which was granted by the Spanish Ministry of Science and Innovation, and the Sample Preparation Study Group and Network, which were sponsored by the European Chemical Society s Division of Analytical Chemistry. Funding for open access charges from CRUE-Universitat Politecnica de Valencia is gratefully acknowledged.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

In-house metal-organic framework material for stir-bar sorptive extraction of acidic pharmaceutical compounds from environmental water samples

  • Trullàs, Abril
  • Martínez-Pérez-Cejuela, Héctor
  • Borrull, Francesc
  • Herrero Martínez, José Manuel
  • Marcé, Rosa Maria
  • Fontanals, Núria
  • Catalá-Icardo, Mónica|||0000-0001-5897-8501
[EN] Pharmaceutical residues are emerging contaminants in aquatic environments due to widespread use, improper disposal and incomplete removal in wastewater treatment plants. Although usually present at trace levels, they can pose ecological risks because of their bioaccumulation potential and biological activity. This study develops and evaluates a low-cost in-house hybrid coating for stir-bar sorptive extraction (SBSE) designed to improve the recovery of polar acidic pharmaceuticals. The coating is based on an amine-functionalized metal-organic framework providing weak anion exchange interactions, attached to a glycidyl methacrylate monolith (GMA@NH2-UiO-66(Zr)), with an estimated cost below 5 EUR per unit. The method was optimized and coupled to liquid chromatography tandem mass spectrometry (LC-MS/MS) for analysis of environmental waters. In river water, the approach achieved limits of detection around 2 ng/L, recoveries of 22 to 41 percent, matrix effects between plus 9 and minus 2 percent, and precision with relative standard deviation below 25 percent. After validation, the method was applied to real samples, detecting acidic pharmaceuticals at ng/L levels. The new SBSE material showed improved retention of polar compounds, good mechanical stability, and reproducibility, supporting its use for routine monitoring of pharmaceutical contaminants in environmental waters., These results are part of the project PID2023-148939NB-I00, PID2021-125459OB-I00, and grant RED2022-134079-T funded by MICIU/AEI/10.13039/501100011033 and "ERDF/EU". They were possible thanks to the support of the Joan Oro predoctoral grant program from the Department of Research and Universities of the Government of Catalonia and co-financing by the European Social Fund Plus (2024FISDU00309).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Electrochemically controlled liquid-liquid microextraction: an innovative methodology for heavy metal extraction from tea using non-toxic menthol-based eutectic mixture

  • Marco, Andrea
  • Aguirre, Miguel Ángel
  • Hidalgo, Montserrat
  • Quijada, César|||0000-0002-9965-9651
[EN] Background A growing concern about toxic metal contamination in food has generated a need for efficient, sustainable, and non-toxic sample preparation techniques. Conventional extraction methodologies frequently entail the utilization of hazardous solvents or exhibit a lack of sensitivity. There is an increasing demand for analytical methodologies that are more environmentally friendly and capable of extracting trace metals from complex matrices, such as tea. This study aims to address the need for an efficient and environmentally friendly method for the extraction of metals from tea samples using a combination of electrochemically assisted microextraction and a eutectic mixture as extractant. Results An innovative electrochemically enhanced liquid-liquid microextraction technique has been developed, employing a green eutectic mixture composed of a menthol-based hydrophobic deep eutectic solvent (menthol:decanoic acid, 2:1) and a non-toxic ionic liquid (1-hexyl-3-methylimidazolium chloride) to enhance conductivity. The experimental conditions for the extraction procedure were optimized through the implementation of a design of experiments approach. In the context of optimal conditions (i.e., 10 g sample, 315 ¿L extractant, 5 min extraction, pH 4.66, 1 wt% 8-hydroxyquinoline, 600 rpm shaking and a single ¿0.75 V pulse vs. Ag), the method demonstrated excellent linearity, repeatability, and low limits of detection: 0.2, 0.2, 0.7, 2.8 and 0.5 ¿g kg¿1 for Cd, Cr, Ni, Pb and Zn, respectively. The recovery of real and certified tea samples approached 100 %, with negligible matrix effects. Furthermore, no analytes exceeded the maximum permissible limits established by legislation in the infused samples under study. Significance The proposed method represents a substantial advance in sustainable analytical chemistry, as it facilitates the efficient extraction of metals from tea without the use of toxic solvents. Its performance and environmental compatibility position it as a solid alternative for routine metal analysis in food safety monitoring., The authors are grateful for the financial support received from the Valencia Regional Government (Spain) (CIPROM/2021/062) and the Spanish Ministry of Science and Innovation (PID2021-126155OB-I00) . Authors also wish to thank the Spanish Network of Excellence in Sample Preparation (RED2022-134079-T) , which was granted by the Spanish Ministry of Science and Innovation, and the Sample Preparation Study Group and Network, which were sponsored by the European Chemical Society's Division of Analytical Chemistry.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Sensitive elemental analysis of edible oil samples using a hydrophilic eutectic mixture as green solvent in electrochemically controlled liquid-liquid microextraction

  • Marco, Andrea
  • Pertusa, Borja
  • Aguirre, Miguel Angel
  • Hidalgo, Montserrat
  • Quijada, César|||0000-0002-9965-9651
[EN] Background: Analyzing toxic metals in edible oils is crucial due to the associated health risks and strict regulatory limits. Traditional extraction methods are often time-consuming and require toxic solvents. Additionally, they are sometimes ineffective in complex oil matrices. Therefore, there is a strong demand for sustainable, efficient methodologies for extracting trace metals from oils. This study presents a green, effective approach to metal extraction from various edible oils using electrochemically enhanced microextraction. Results: We present a new, environmentally friendly, electrochemically enhanced liquid-liquid microextraction (EC-LLME) method that uses a choline chloride-based deep eutectic solvent (CC:EG, 1:2) to extract Cd, Cu, Fe, Ni, and Pb from various oil samples. We optimized the extraction parameters using a two-step experimental design. Under the optimal conditions of a 15 g sample, 315 ¿L of extractant, a 10 min extraction time, and a ¿ 0.75 V vs Ag pulse, the method achieved excellent linearity in the range of 5¿500 ¿g kg¿ 1 , high repeatability (CV ¿ 6 %), and low detection limits: 0.16 ¿g kg¿ 1 (Cd and Fe), 0.09 ¿g kg¿ 1 (Cu), 0.4 ¿g kg¿ 1 (Ni), and 1.5 ¿g kg¿ 1 (Pb). No analyte exceeded legal limits in the three samples studied (i.e., refined rapeseed oil, refined sunflower oil, and virgin olive oil), and recoveries in real and certified samples were nearly 100 %, confirming minimal matrix effects. Significance: The EC-LLME method is a novel, sustainable alternative for extracting and quantifying trace metals in edible oils. Its superb analytical capabilities and eco-friendly safety, achieved by steering clear of noxious solvents, make it a suitable option for the identification of trace metals in edible vegetable oil samples., The authors are grateful for the financial support received from the Valencia Regional Government (Spain) (CIPROM/2021/062) and the Spanish Ministry of Science and Innovation (PID2021-126155OB-I00). Authors also wish to thank the Spanish Network of Excellence in Sample Preparation (RED2022-134079-T), which was granted by the Spanish Ministry of Science and Innovation, and the Sample Preparation Study Group and Network, which were sponsored by the European Chemical Society s Division of Analytical Chemistry.
Repositori Institucional UIB
Publication Artículo científico (JournalArticle)

Electromembrane Extraction in Suspect Screening of Polar Organic Xenobiotics and their Metabolites in Human Urine: A New Approach to Enhance Compound Annotation?

  • Musatadi, Mikel
  • Sahragard, Ali
  • Anakabe, Eneritz
  • Etxebarria, Nestor
  • Olivares, Maitane
  • Zuloaga, Olatz
  • Miró, Manuel
[eng] Suspect and nontarget screening (SNTS) methodologies using human urine are invaluable strategies for understanding the human exposome. However, very polar organic compounds are often overlooked in those methods due to challenges in sample preparation and chromatographic analysis. Although “dilute-and-shoot” (DS) followed by mixed-mode liquid chromatography–high-resolution mass spectrometry (MMLC-HRMS) might be deemed suitable, complementary strategies are needed to enhance SNTS and expand compound identification. In this context, the potential of nonsupported microelectromembrane extraction (μ-EME) is thoroughly studied as a supplement to DS-MMLC-HRMS. It was demonstrated that μ-EME-MMLC-HRMS enables the refinement of suspect screening results from a 24 h pooled human urine sample. The selective extraction capability of μ-EME for charged analytes, compared to DS, allowed the identification of 24 false positives and 4 false negatives. The confidence level of 6 suspects was also enhanced through μ-EME interpretation. Moreover, nine suspects were identified exclusively in μ-EME experiments due to the urine cleanup provided by that technique. Notably, suspects containing carboxylic acid groups (phase II metabolites) and amines were particularly well-annotated by μ-EME employing selective extraction conditions for acids and bases, respectively. Thus, μ-EME proves to be a confirmatory dimension in MMLC-based SNTS approaches.
Repositori Institucional UIB
Publication Artículo científico (JournalArticle)

Suspect screening boosts bioaccessibility assays of phenolic compounds in food commodities: A proof of concept

  • Alonso-Salces, Rosa María
  • Ayala Cabrera, Juan Francisco
  • Miró, Manuel
  • Musatadi, Mikel
  • Olivares, Maitane
  • Prieto, Ailette
  • Sahragard, Ali
  • Zuloaga, Olatz
[eng] The knowledge of the actual oral bioaccessibility of phenolic compounds through food intake in the human gut is a key factor for assessing their potential health benefits. To this end, there is a quest to develop advanced analytical methodologies that are able to expand the chemical space offered by targeted methods. In fact, suspect screening workflows using high-resolution mass spectrometry might shed light on the vast diversity of phenolic compounds in food commodities that might be released in the gut fluids. Herein, targeted and suspect screening assays of phenolic substances in gastric extracts were performed to investigate the relative bioaccessibility of these compounds in the crushed solid fruit as compared to the fruit juice intake. The analytical method was validated for 30 phenolic compounds using a targeted workflow in both positive and negative modes, with dynamic linear ranges spanning from 1.0 to 4000 ng/mL and repeatability values ranging from 0.3 to 13.6% under matrix-matched calibration. Validation was performed in a pH-adjusted gastric extract, with the negative mode offering the most sensitive detection for subsequent real sample analysis. Thereafter, suspect screening workflows of the phenolic compounds and their plant metabolites were conducted in juiced and crushed fruits after the gastric extraction process. The workflow resulted in the confirmation of 8 features with pure standards (level 1), and 24 additional tentative annotations in levels 2–4. The results demonstrated that 59.4% of phenolic compounds annotated in the gastric extracts have higher relative acid bioaccessibility from the solid fruit, 34.4% higher from the juiced samples, and 6.2% equally distributed. Additionally, the targeted and suspect results indicated that there was a significant correlation between the number of phenolic hydroxyls on the relative bioaccessibility of the compounds. However, the relevance of the type of phenolic compounds, e.g., being flavonoid or non-flavonoid, was not statistically significant. This study aims to provide a holistic perspective on how the form of food intake (juice versus whole fruit) can be strategically selected according to specific phenolic compounds to achieve bespoke nutritional and food industry benefits.
Minerva. Repositorio Institucional de la Universidad de Santiago de Compostela
Publication Artículo científico (JournalArticle)

Occurrence of twelve UV filters and evidence of cis-octinoxate formation in Adriatic coastal waters: Environmental implications

  • Zulfiqar, Hira
  • Llompart Vizoso, María del Pilar
  • Castiñeira Landeira, Ana
  • Coralli, Irene
  • Vassura, Ivano
  • Fabbri, Daniele
UV filters used in personal care products are increasingly recognised as emerging contaminants due to their persistence and ecological risks. Detected in aquatic systems at concentrations from ng L−1 to μg L−1, their monitoring is essential for environmental risk assessment but challenging because of their diverse physicochemical properties, requiring sensitive analytical methods. This study optimised a solid-phase extraction gas chromatography–tandem mass spectrometry (SPE-GC–MS/MS) method for the simultaneous determination of twelve UV filters in marine waters. The method showed suitable linearity, precision, and recoveries, with detection limits below 1 ng L−1. Seawater samples collected along the Adriatic coast (Rimini and Riccione, Italy) during peak recreational activity were analysed. All twelve UV filters were detected, with octocrylene (up to 23,100 ng L−1), homosalate (up to 16,400 ng L−1), and ethylhexyl salicylate (up to 10,900 ng L−1) being most abundant. Trans-2-Ethylhexyl methoxycinnamate (E-EHMC, the trans isomer of octinoxate, 13–1474 ng L−1) occurred consistently with its isomer Z-EHMC (cis-octinoxate), contributing 18–64 % of total (E + Z)-EHMC, suggesting in situ photochemical conversion, since the cis form is negligible in cosmetic products. Benzophenone, ethylhexyl dimethyl PABA, 4-methylbenzylidene camphor, benzyl salicylate, and isoamyl methoxycinnamate were found at lower yet relevant concentrations. UV filters banned under European regulations, such as menthyl anthranilate and etocrylene, were absent or barely detected. This work provides the first data on sunscreen UV filters in Adriatic coastal waters and the first quantitative evidence of Z-EHMC in environmental waters, highlighting its in situ formation and contributing to understanding their environmental fate and risks.
Minerva. Repositorio Institucional de la Universidad de Santiago de Compostela
Publication Artículo científico (JournalArticle)

Multiresidue microextraction–GC-MS/MS for emerging tire rubber contaminants in urban waters

  • Duque Villaverde, Andrés
  • Dagnac, Thierry
  • Llompart Vizoso, María del Pilar
Tire rubber contains many chemicals that can enter aquatic ecosystems through tire wear particles or leachates from crumb rubber surfaces. The antiozonant N-(1,3-dimethylbutyl)-N′-phenyl-p-phenylenediamine (6PPD) and its transformation product, 6PPD-quinone, are of particular concern due to their toxicity associated with aquatic species mortality. Other relevant compounds from the PPD family are DPPD and IPPD. Vulcanizing and crosslinking agents, including benzothiazole, 2-mercaptobenzothiazole, N-cyclohexylbenzothiazole-2-sulfenamide (CBS) and hexamethoxymethylmelamine (HMMM), together with alkyl organophosphate esters and alkyldimethylamines are also of great interest. This work aimed to develop an analytical method for detecting and quantifying 11 emerging tire rubber contaminants in urban waters. The method is based on solid-phase microextraction (SPME) using commercial fibers followed by gas chromatography coupled to tandem mass spectrometry (GC-MS/MS). SPME parameters were optimized via multivariate design to efficiently extract all analytes. The method was successfully validated for linearity, precision, and accuracy, with mean recoveries of 84–105%. In all the urban water samples analyzed, 6PPD and 6PPDQ were detected. To our knowledge, this is the first time that GC–MS/MS has been applied to the analysis of most of these compounds, including PPDs, as well as the first proposal of SPME for the extraction and analysis of many of these compounds. This is also the first investigation of these substances in real water samples originating from recycled tire rubber surfaces as a potential source of contamination. Due to its simplicity, this multiresidue method, which includes antiozonants, vulcanizing, and crosslinking agents, can be easily implemented in any routine laboratory.
Helvia. Repositorio Institucional de la Universidad de Córdoba
Publication Artículo científico (JournalArticle)

Coupling Miniaturized Stir Bar Sorptive Dispersive Microextraction to Needle-Based Electrospray Ionization Emitters for Mass Spectrometry: Determination of Tetrahydrocannabinol in Human Saliva as a Proof of Concept

  • López-Juan, Andreu L.
  • Millán-Santiago, Jaime
  • Benedé, Juan L.
  • Chisvert, Alberto
  • Lucena, Rafael
  • Cárdenas, Soledad
Direct coupling of sample preparation with mass spectrometry (MS) can speed up analysis, enabling faster decision-making. In such combinations, where the analysis time is mainly defined by the extraction procedure, magnetic dispersive solid-phase extraction emerges as a relevant technique because of its rapid workflow. The dispersion and retrieval of the magnetic sorbent are typically uncoupled stages, thus reducing the potential simplicity. Stir bar sorptive dispersive microextraction (SBSDME) is a novel technique that integrates both stages into a single device. Its miniaturization (mSBSDME) makes it more portable and compatible with low-availability samples. This article reports the direct combination of mSBSDME and MS using a needle-based electrospray ionization (NESI) emitter as the interface. This combination is applied to determine tetrahydrocannabinol in saliva samples, a relevant societal problem if the global consumption rates of cannabis are considered. The coupling requires only the transference of the magnet (containing the sorbent and the isolated analyte) from the mSBSDME to the hub of a hypodermic needle, where the online elution occurs. The application of 5 kV on the needle forms an electrospray on its tip, transferring the ionized analyte to the MS inlet. The excellent performance of mSBSDME-NESI-MS/MS relies on the sensitivity (limits of detection as low as 2.25 ng mL–1), the precision (relative standard deviation lower than 15%), and the accuracy (relative recoveries ranged from 87 to 127%) obtained. According to the results, the mSBSDME-NESI-MS/MS technique promises faster and more efficient chemical analysis in MS-based applications.
Helvia. Repositorio Institucional de la Universidad de Córdoba
Publication Artículo científico (JournalArticle)

Silica microparticles as guiding substrates for the fabrication of polyamide-coated stainless-steel sheets by dip-coating technique: Application to the determination of opioids in saliva samples by direct infusion mass spectrometry

  • Pedraza-Soto, Ana M.
  • Lucena, Rafael
  • Cárdenas, Soledad
Background Dip-coating is a simple and cost-effective technique for synthesizing thin film sorptive phases in microextraction. The success of the coating (amount and homogeneity) relies dramatically on the wettability of the substrate, thus making the covering of smooth-surface substrates challenging. In these cases, prior to the slurry (particles and binder) deposition, the smooth-surface substrate typically requires an aggressive etching step (e.g., treating the surface with strong acids or bases) to increase the roughness of the metallic substrate. This strategy has a clear environmental and operational safety impact and increases the associated costs. Results In this article, we explored the use of amorphous silica gel particles as a cost-effective guiding substrate to improve the wettability and increase the superficial area of the final coating. For this purpose, a double-sided adhesive tape is used to immobilize the silica particles over stainless-steel sheets, thus creating a porous substrate where a thin layer of polymer is finally deposited by dip-coating. The resulting nylon-silica gel sheets (NSG-sheet) have been evaluated for the extraction of some opioids (codeine, methadone, oxycodone, and tramadol) from saliva samples and their direct infusion mass spectrometry analysis. The developed method allows the determination of the analytes at the low μg L−1 range with levels with intra- and inter-day precision, expressed as relative standard deviation, better than 9.5 and 13.7 %, respectively. Significance and novelty This research deepens the potential of adhesive tapes for designing novel sorptive phases. It also provides a straightforward approach to synthesizing thin film microextraction devices using affordable and sustainable materials and procedures. The resulting analytical method has been thoroughly validated, and it has been demonstrated to be competitive with existing methods. Also, the potential of the devices in on-site extraction procedures has been preliminarily explored.
Helvia. Repositorio Institucional de la Universidad de Córdoba
Publication Artículo científico (JournalArticle)

Quantitative determination of drug residues in surfaces, analyzing cotton-swabs by on/off thermal desorption-plasma based ionization-mass spectrometry

  • Cárdenas, Soledad
  • Calero-Cañuelo, Carlos
  • Lucena, Rafael
  • Cárdenas, Soledad
Background The determination of drug residues in surfaces is a relevant analytical problem in forensic sciences. Ambient ionization mass spectrometry (AIMS) has revolutionized this field, providing high sensitivity and selectivity levels at shorter analysis times, thus permitting quick decision-making. Those surfaces that cannot be directly measured require their previous sampling with an appropriate swab that can finally be analyzed by AIMS. In this field, dielectric barrier discharge ionization is a great alternative for analyzing swabs after surface sampling in a quick and easy way. Results In this work, we propose sampling the surface with a cotton swab wet with an internal standard (IS) for better precision and easier quantification. After sampling, the swab is placed in a dedicated interface where an on/off thermal desorption takes place in front of the low-temperature plasma ionization source. The method was applied to the determination of three drugs in different surfaces, providing limits of detections as low as 0.01 ng/cm2. The intra-day and inter-day precision at the limit of quantification, expressed as relative standard deviation, were better than 10.8 and 15.2 %, respectively. The accuracy, expressed as relative recovery, was in the range of 81.6–124.5 %. Finally, the effect of the swab type on the analytical performance was evaluated. The use of a commercial swab is highly recommended. Significance and novelty This research succeeded in developing a simple methodology for the analysis of drugs on surfaces using cotton swabs. For this purpose, a methanolic solution containing the ISs facilitated sample collection and allowed the quantitative analysis. Also, a rapid analysis of the samples was carried out in an interface built with simple elements, making the whole process affordable and simple. The approach can be considered almost solventless (20 μL per sample), thus reducing the environmental impact.
Helvia. Repositorio Institucional de la Universidad de Córdoba
Publication Artículo científico (JournalArticle)

Microbeads from recycled polystyrene yogurt cups for the in-syringe micro solid-phase extraction of four opioids from environmental and biological sample

  • Antonelli, Lorenzo
  • López-Lorente, A.I.
  • Gentili, Alessandra
  • Lucena, Rafael
  • Cárdenas, Soledad
A novel procedure for the extraction and determination of four opioids from environmental and biological fluids is presented. The main goal of this study is to introduce an innovative method for recycling plastic waste (i.e., polystyrene), aiming to achieve a consistent and dependable microstructure. Polystyrene microbeads, deposited on a rounded piece of paper, have been used as a sorbent material in an in-syringe extraction device. For the preparation of the polymeric sorbent, an emulsion solidification technique was optimized, achieving a regular micro material, obtained from second-hand regenerated polystyrene polymer from yogurt cups. This work presents, for the first time, the use of recycled polystyrene as micro-sorbent integrated into a paper-based support, combining waste valorization with effective analyte extraction. Under the optimum conditions, methadone, tramadol, codeine, and morphine were determined by direct injection mass spectrometry in environmental water as well as biofluids as saliva and urine. Limits of detection lower than 8 μg L−1 and precision better than 14.9 % have been obtained for all the analytes in saliva and environmental water samples. The interference of the endogenous compounds of urine prevents the determination of morphine and codeine in this matrix. The trueness, expressed as relative recovery (RR), ranged from 85 % to 114 %. The extraction device has proved to be a valid and sustainable alternative to traditional sorbents, offering good analytical standards and being transversal for the application to different matrices. The simplicity and environmental friendliness of this approach make it highly adaptable across various research and industrial domains.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Hydrophobic natural deep eutectic solvents based on L-menthol as supported liquid membrane for hollow fiber liquid-phase microextraction of triazines from water and urine samples

  • Díaz-Álvarez, Myriam
  • Turiel Trujillo, Esther
  • Martín Esteban, Antonio
This work proposes the use of a hydrophobic natural deep eutectic solvent (NADES) as a supported liquid membrane (SLM) for hollow fiber liquid phase microextraction (HF-LPME) of triazines. NADES were prepared using L-menthol as hydrogen bond acceptor combined with different hydrogen bond donors of natural origin: carboxlylic acids, alcohols and amines. Studies were carried out to determine whether the prepared NADES met the necessary requirements to be used as a SLM, such as stability in the HF and compatibility with HPLC. Then, the ability of each prepared NADES to extract 6 triazine herbicides by HF-LPME from aqueous samples was evaluated. Among them, the mixture L-menthol: formic acid (molar ratio 1:2) provided better extraction results and was selected as SLM. The influence the different parameters on extraction efficiency such as pH of both sample and acceptor solution, salting-out effect, extraction time and stirring rate on the extraction efficiency was carefully studied and optimized. The optimized HF-LPME procedure was applied to the analysis of aqueous samples such as artificial water containing humic acids, tap water, river water and urine, with excellent clean-up ability for all samples analyzed. Relative recoveries ranged from 68 to 128 %, and the LODs and LOQs obtained for the 6 triazines were 0.75–3.1 µg/L and 2.5–10.3 µg/L, respectively, depending on the analyte and the kind of sample. Additionally, according to the AGREEprep tool assessment, the proposed method appears as a greener approach compared to other microextraction methods reported in the literature for the analysis of triazines in water samples., The Grant PID2021-122327OB-I00 funded by MCIN/AEI/ 10.13039/501100011033 and by “ERDF A way of making Europe” is gratefully acknowledged. This article is based upon work from the National Thematic Network on Sustainable Sample Treatment (RED2022-134079-T) funded by the Spanish Ministry of Science and Innovation, and the Sample Preparation Study Group and Network, supported by the Division of Analytical Chemistry of the European Chemical Society., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Natural deep eutectic solvents as sustainable alternative for the Ultrasound-Assisted extraction of triazines from agricultural soils

  • Turiel Trujillo, Esther
  • Díaz-Álvarez, Myriam
  • Martín Esteban, Antonio
9 Pág., Natural deep eutectic solvents (NADES) have gained much attention as a viable and sustainable alternative to traditional organic solvents in multiple areas of analytical chemistry, including extraction of contaminants from samples of environmental concern. In this work, a total of 68 potential NADES have been assayed and further evaluated as sustainable solvents in the development of an ultrasound (US)-assisted extraction method for triazinic herbicides from agricultural soil samples and final determination by HPLC-UV. Choline chloride (ChCl) was used as hydrogen bond acceptor (HBA), and different carboxylic acids, alcohols and amines were tested as hydrogen bond donors (HBDs) in different molar ratios in order to find the optimum combination able to form appropriated NADES for the extraction of triazines. Among the different ChCl:carboxylic acids mixtures tested, those consisting of ChCl:formic acid and ChCl:acetic acid, both in a molar ratio 1:2, presented the better physico-chemical properties (pH, stability at room temperature, water miscibility, etc.). Concerning amines, NADES could not be obtained at any of the combination assayed whereas, among the alcohols tested, 2,3-butanediol was found to be the most appropriated for NADES formation. A three-level factorial design was then used to further evaluate the effect of time and temperature on the ability of these selected optimum NADES for the US-assisted extraction of triazines from agricultural soil samples. Under optimal conditions, the developed US-assisted extraction method provided quantitative recoveries (from 87 to 104 %) with good reproducibility (RSDs lower than 12 %) and limits of detection (LODs) lower than 0.05 μg g−1 for all target triazines., The Grant PID2021-122327OB-I00 funded by MCIN/AEI/ 10.13039/501100011033 and by “ERDF A way of making Europe” is gratefully acknowledged. This article is based upon work from the National Thematic Network on Sustainable Sample Treatment (RED2022-134079-T) funded by the Spanish Ministry of Science and Innovation, and the Sample Preparation Study Group and Network, supported by the Division of Analytical Chemistry of the European Chemical Society. Authors wish thank Mar Albarrán for supplying soil samples., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Evaluation of deep eutectic solvents in the synthesis of molecularly imprinted fibers for the solid-phase microextraction of triazines in soil samples

  • Monnier, Alexia
  • Díaz-Álvarez, Myriam
  • Turiel Trujillo, Esther
  • Martín Esteban, Antonio
11 Pág., Nowadays, molecularly imprinted polymers (MIPs) are well established and are considered excellent materials for performing selective extractions. However, with the progressive implementation of the principles of green chemistry, it is necessary to find greener alternatives for both the synthesis and further use of MIPs in sample preparation. Accordingly, in the present work, different deep eutectic solvents (DES, both hydrophilic and hydrophobic), as an alternative to conventional organic solvents (i.e., toluene), were evaluated as porogens for the synthesis of imprinted fibers (monoliths), using fused silica capillaries as molds, for solid-phase microextraction (SPME). From this study, the polymer prepared with propazine (dummy template), methacrylic acid (monomer), ethylene glycol dimethacrylate (cross-linker), and a formic acid:L-menthol (1:1) DES (porogen) showed the best performance for selective rebinding of triazines. After optimization of the different variables involved in SPME, the new imprinted fibers were successfully applied to the extraction of target analytes (desisopropylatrazine, desethylatrazine, simazine, and atrazine) from soil sample extracts, providing relative recoveries ranging from 75.7 to 120.1%, reaching limits of detection within the range of 6.2-15.7 ng g-1, depending upon the analyte., The Grant PID2021-122327OB-I00 funded by MCIN/AEI/ 10.13039/501100011033 and by “ERDF A way of making Europe” is gratefully acknowledged. This article is based upon work from the National Thematic Network on Sustainable Sample Treatment (RED2022-134079-T) funded by the Spanish Ministry of Science and Innovation, and the Sample Preparation Study Group and Network, supported by the Division of Analytical Chemistry of the European Chemical Society., Open Access funding provided thanks to the CRUE-CSIC agreement with Springer Nature., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Ultrasound-assisted extraction of sulfonamides from soil samples using natural deep eutectic solvents and their determination by liquid chromatography tandem mass spectrometry

  • García Valcárcel, Ana Isabel
  • Martín Esteban, Antonio
8 Pág., In this work, several potential natural deep eutectic solvents (NADES) were evaluated as sustainable solvents in the development of an ultrasound (US)-assisted extraction method for sulfonamides from soil samples and final determination by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Choline chloride (ChCl) was used as hydrogen bond acceptor (HBA), and different carboxylic acids and alcohols were tested as hydrogen bond donors (HBDs) in different molar ratios in order to find the optimum combination able to form appropriated NADES for the extraction of sulfonamides. Among the different mixtures tested, the one consisting of ChCl:1,3-propanediol in a molar ratio of 1:4 showed the better physico-chemical properties and was selected for the US-assisted extraction of sulfonamides. Under optimum conditions, no matrix effect was observed and quantitative recoveries, ranging from 81.9 % to 103.9 % with relative standard deviations (RSDs) lower than 8 % were obtained, reaching limits of quantification within the range 8.5–31 µg Kg−1, depending upon the analyte. In addition, after evaluation by AGREEprep, Sample Preparation Metric of Sustainability (SPMS) and Blue Applicability Grade Index (BAGI) metrics tools, the proposed method was found to be superior to other published methods in terms of safety and environmental impact with good applicability potential., The Grant PID2021-122327OB-I00 funded by MCIN/AEI/ 10.13039/501100011033 and by “ERDF A way of making Europe” is gratefully acknowledged. This article is based upon work from the National Thematic Network on Sustainable Sample Treatment (RED2022-134079-T) funded by the Spanish Ministry of Science and Innovation, and the Sample Preparation Study Group and Network, supported by the Division of Analytical Chemistry of the European Chemical Society. Authors wish to thanks Jennifer Ayala and Esther Turiel for their collaboration in the experimental work and for fruitful comments and discussions during the development of the present work., Peer reviewed
Investigo. Repositorio Institucional de la Universidade de Vigo
Publication Artículo científico (JournalArticle)

A perspective on current and future metric tools

  • Pena Pereira, Francisco Javier
  • Benedé, Juan L.
Assessment tools have attracted immense interest in the analytical field in recent years, and remarkable developments have been described toward increasing levels of refinement. However, substantial improvements of metric tools are still needed to obtain highly relevant information about analytical systems in an efficient manner while maintaining or increasing their user friendliness, minimizing their potential subjectivity, and ensuring a high reliability and comparability. The present perspective identifies areas of improvement of currently available metric tools and highlights potential initiatives to be tackled toward advanced metric tools, Agencia Estatal de Investigación | Ref. PID2022-136337OB-I00, Agencia Estatal de Investigación | Ref. RED-2022-134079-T, Universidade de Vigo/CISUG