GPU-based fast iterative reconstruction of fully 3-D PET sinograms

  • Herraiz, J. L.
  • España, Samuel
  • Cabido, R.
  • Montemayor, A. S.
  • Desco Menéndez, Manuel
  • Vaquero López, Juan José
  • Udías, José Manuel
This work presents a graphics processing unit (GPU)-based implementation of a fully 3-D PET iterative reconstruction code, FIRST (Fast Iterative Reconstruction Software for [PET] Tomography), which was developed by our group. We describe the main steps followed to convert the FIRST code (which can run on several CPUs using the message passing interface [MPI] protocol) into a code where the main time-consuming parts of the reconstruction process (forward and backward projection) are massively parallelized on a GPU. Our objective was to obtain significant acceleration of the reconstruction without compromising the image quality or the flexibility of the CPU implementation. Therefore, we implemented a GPU version using an abstraction layer for the GPU, namely, CUDA C. The code reconstructs images from sinogram data, and with the same System Response Matrix obtained from Monte Carlo simulations than the CPU version. The use of memory was optimized to ensure good performance in the GPU. The code was adapted for the VrPET small-animal PET scanner. The CUDA version is more than 70 times faster than the original code running in a single core of a high-end CPU, with no loss of accuracy., This work was supported in part by AMIT Project funded by CDTI (CENIT Programme), UCM (Grupos UCM, 910059), CPAN (Consolider-Ingenio 2010, CSPD-2007-00042), RECAVA- RETIC network, Comunidad de Madrid (ARTEMIS S2009/DPI-1802), Ministerio de Ciencia e Innovación, Spanish Government (ENTEPRASE grant, PSE-300000-2009-5 and TEC2007-64731/TCM), and European Regional funds., Publicado
e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publication Artículo científico (JournalArticle)

Automatic Cardiac Self-Gating of Small-Animal PET Data

  • Herraiz, J. L.
  • Herranz, Elena
  • Cal González, Jacobo
  • Vaquero López, Juan José
  • Desco Menéndez, Manuel
  • Cusso Mula, Lorena
  • Udías, José Manuel
Purpose: The cardiac gating signal (CGS) in positron emission tomography (PET) studies is usually obtained from an electrocardiography (ECG) monitor. In this work, we propose a method to obtain the CGS in small-animal PET using the acquired list-mode data without using any hardware or end-user input. Procedures: The CGS was obtained from the number of coincidences over time acquired in the lines-of-response connected with the cardiac region. This region is identified in the image as its value changes with frequencies in the range of 3 to 12 Hz. The procedure was tested in a study with 29 Wistar rats and 6 mice injected with 2-deoxy-2-[18F]fluoro-D-glucose, which underwent a 45-min single-bed list-mode PET scan of the heart syncronized with an ECG. The estimated signals and the reconstructed images using eight-gated frames were compared with the ones obtained using the ECG signal from the monitor. Results: The differences of the PET-based CGS with respect to the ECG relative to the duration of the heartbeats were 5.6 % in rats and 11.0 % in mice. The reconstructed gated images obtained from the proposed method do not differ qualitatively with respect to the ones obtained with the ECG. The quantitative analysis of both set of images were performed measuring the volume of the left ventricle (LV) of the rats in the end-of-systole and end-of-diastole phase. The differences found in these parameters between both methods were below 12.1 % in the ESV and 9.3 % in the EDV with a 95 % confidence interval, which are comparable to the accuracy (7 %) of the method used for segmenting the LV. Conclusion: The proposed method is able to provide a valid and accurate CGS in small-animal PET list-mode data. the ones obtained using the ECG signal from the monitor., This work was supported in part by Consejería de Educación, Juventud y Deporte de la Comunidad de Madrid (Spain) through the Madrid-MIT M+Visión Consortium, Comunidad de Madrid (S2013/MIT-3024 TOPUS-CM), UCM (Grupos UCM, 910059), CPAN (Consolider-Ingenio 2010, CSPD-2007-00042), RIC-RETIC network, Spanish MINECO (RD12/0042/0057),Ministerio de Ciencia e Innovación, Spanish Government (ENTEPRASE grant, PSE-300000-2009-5 and TEC2007-64731/TCM), and European Regional funds.