RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Automatic Quality Electrogram Assessment Improves Reentrant Activity Identification in Atrial Fibrillation

  • Costoya-Sánchez, Alejandro
  • Hernández-Romero, Ismael
  • Liberos, Alejandro
  • Fernández-Avilés, Francisco
  • Narayan, Sanjiv M.
  • Atienza, Felipe
  • Rodrigo, Miguel
  • Andreu M. Climent|||0000-0002-7260-8811
  • Guillem Sánchez, María Salud|||0000-0001-5660-3693
[EN] Location of reentrant electrical activity responsible for driving atrial fibrillation (AF) is key to ablative therapies. The aim of this work is to study the effect of the quality of the electrograms (EGMs) used for 3D phase analysis on reentrant activity identification, as well as to develop an algorithm capable of automatically identifying lowquality signals. EGMs signals from 259 episodes obtained from 29 AF patients were recorded using 64-electrode basket catheters. Low-quality EGMs were manually identified. Reentrant activity was identified in 3D phase maps and provided an area under the ROC curve (AUC) of 0.69 when compared to a 2D activation-based method. Reentries located in regions with poor-quality EGMs were then removed, increasing the AUC to 0.80. The EGM classification algorithm showed a similar performance both for low-quality EGM identification (sensitivity 0.91 and specificity 0.80) and for reentrant activity location with 3D phase analysis (AUC 0.80). Discard of reentrant activity identified in regions where EGMs showed low quality significantly improved the specificity of the 3D phase analysis. Besides, EGMs classification according to their quality proved to be possible using time and spectral domain parameters., This work was supported by the Instituto de Salud Carlos III FEDER (DTS16/00160; PI16/01123; PI17/01059; PI17/01106), the EIT-Health 19600 AFFINE and the Valencian Regional Government (AICO2018).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Non-Invasive Electrophysiological Mapping Entropy Predicts Atrial Fibrillation Ablation Efficacy Better Than Clinical Characteristics

  • De la Nava, A. S.
  • Fabregat, M. C.
  • Rodrigo, M.
  • Hernández, I.
  • Liberos, A.
  • Fernández-Avilés, F.
  • Atienza, F.
  • Guillem Sánchez, María Salud|||0000-0001-5660-3693
  • Andreu M. Climent|||0000-0002-7260-8811
[EN] Success rate of atrial fibrillation (AF) ablation remains far from satisfactory. In this study, a 6 months AF freedom predictive model based on Fuzzy Entropy of non-invasive body surface potential maps is compared with clinical predictors. The study included 29 patients referred for pulmonary vein isolated catheter ablation procedure. Non-invasive electrocardiographic mapping with 54 ECG electrodes was recorded for all patients during the ablation procedure. Six months follow up was used to evaluate the efficacy of the ablation procedure. Predictions based on non-invasive electrocardiographic mappings during adenosine infusion (accuracy: 90%, AUC: 0.93) showed a clear improvement over standard-of-care clinical parameter models (accuracy: 62.1%, AUC: 0. 54). Our results indicate that measurements of electrophysiological complexity of AF signals could improve the clinical practice by predicting the efficacy of AF ablation procedures., This work was supported by the Instituto de Salud Carlos III FEDER (DTS16/00160; PI16/01123; PI17/01059; PI17/01106; EIT-Health 19600 AFFINE)
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Temporal Stability of Dominant Frequency as Predictor of Atrial Fibrillation Recurrence

  • Costoya-Sánchez, Alejandro
  • Hernández-Romero, Ismael
  • Liberos, Alejandro
  • Fernández-Avilés, Francisco
  • Narayan, Sanjiv M.
  • Atienza, Felipe
  • Rodrigo, Miguel
  • Andreu M. Climent|||0000-0002-7260-8811
  • Guillem Sánchez, María Salud|||0000-0001-5660-3693
[EN] Catheter ablation is one of the main therapies for restoring sinus rhythm in patients with atrial fibrillation (AF), yet AF termination ratios are far from satisfactory. The goal of this work is to study if temporal stability of dominant frequencies (DFs) of electrograms (EGMs) can be used as predictor of AF recurrence. EGMs were recorded from 29 AF patients using 64- pole basket catheters during the ablation procedure. DFs before ablation were obtained for 4-second overlapping fragments of EGM recordings with a 0.4 s shift, and their temporal stability was evaluated for short-term (between 8 and 12 s) and long-term time intervals (>5 min). Patients were classified as AF (N=15) if sinus rhythm was not maintained in a 12-month post-ablation followup, and AF free otherwise (N=14). Significant differences were found in the short-term analysis between AF free and AF patients for the difference between the mode value in DFs (p=0.045), as well as for the long-term analysis for the normalized average between DFs (p=0.028) and the average between DFs (p=0.043). More stable values were found for AF free patients for all statistically significant metrics. Short- and long-term temporal stability of DF values of EGM signals were found to be associated with the 12- month success rate of ablative therapies of AF patients., This work was supported by the Instituto de Salud Carlos III FEDER (DTS16/00160; PI16/01123; PI17/01059; PI17/01106), the EIT-HEALTH 19600 AFFINE and the Valencian Regional Government (AICO2018).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Effects of Geometry in Atrial Fibrillation Markers Obtained With Electrocardiographic Imaging

  • Molero-Alabau, Rubén
  • Hernández-Romero, Ismael
  • Liberos, Alejandro
  • Fernández-Avilés, Francisco
  • Atienza, Felipe
  • Rodrigo, Miguel
  • Andreu M. Climent|||0000-0002-7260-8811
  • Guillem Sánchez, María Salud|||0000-0001-5660-3693
[EN] Electrocardiographic imaging (ECGI) can characterise cardiac pathologies such as atrial fibrillation (AF) through specific markers based on frequency or phase analysis. In this study, the effect of the geometry of patients torso and atria in the ECGI resolution is studied. A realistic 3D atrial geometry was located on 30 patient torsos and ECGI signals were calculated for 30 different AF simulations in each torso. Dominant frequency (DF) and reentrant activity analysis were calculated for each scenario. Anatomical and geometrical measurements of each torso (30-80% of variability between patients) and atria were calculated and compared with the errors in the ECGI estimation versus the departing EGM maps. Results show evidences that big chest dimensions worsen the non-invasive calculation of AF markers (p<0.05). Also, higher number of visible electrodes from each atrial region improves ECGI characterization measured as lower DF deviations (0.64±0.26 Hz vs 0.72±0.27 Hz, p<0.05) and higher reentrant activity coincidence (10.1±12.2% vs 3.4±3.4%, p<0.05). Torso and atrial geometry affect the quality of the non-invasive reconstruction of AF markers such as DF or reentrant activity. Knowing the geometrical parameters that worsen non-invasive AF maps may help to measure each detected AF driver reliability., Supported in part by: Instituto de Salud Carlos III FEDER (Fondo Europeo de Desarrollo Regional; IJCI2014-22178, DTS16/00160; PI14/00857, PI16/01123; PI17/01059; PI17/01106), Generalitat Valenciana Grants (APOSTD/2017 and APOSTD/2018) and projects (GVA/2018/103) and EIT-Health 19600 AFFINE.