Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 15
Encontrada(s) 1 página(s)

Archivo Digital UPM
Publication Contribución de congreso (ConferenceOutput)

Characterisation and efficiency test of a li-ion energy storage system for PV systems

  • Makibar Puente, Aitor|||0000-0002-3536-896X
  • Narvarte Fernández, Luis|||0000-0002-6289-7605
Archivo Digital UPM
Publication Contribución de congreso (ConferenceOutput)

Energy yield estimation of a 75mw PV plant in Tafilalt (Morocco). Example of usefulness of SISIFO tool for contractual frameworks

Archivo Digital UPM
Publication Contribución de congreso (ConferenceOutput)

Modeling and sizing of large PV-diesel hybrid systems without energy storage

Archivo Digital UPM
Publication Contribución de congreso (ConferenceOutput)

SISIFO: The open-source simulation tool of PV systems developed in PVCROPS

  • Carrillo Salinas, José Manuel
  • Muñoz Cano, Javier
  • Makibar Puente, Aitor|||0000-0002-3536-896X
  • Luna, Alberto
  • Narvarte Fernández, Luis|||0000-0002-6289-7605
Archivo Digital UPM
Publication Contribución de congreso (ConferenceOutput)

Energy performance results of 240 mw x year of spanish large-scale pv plants

  • Moretón Villagrá, Rodrigo
  • Lorenzo Pigueiras, Eduardo
  • Martínez Moreno, Francisco
Archivo Digital UPM
Publication Contribución de congreso (ConferenceOutput)

Outdoors measurements of pv module efficiency and temperature coefficients

  • Martínez Moreno, Francisco|||0000-0002-8427-9445
  • Carrillo Salinas, José Manuel
  • Lorenzo Pigueiras, Eduardo
Archivo Digital UPM
Publication Contribución de congreso (ConferenceOutput)

Technical specifications and quality control procedures for reducing the Uncertainty in pv installations: results of the fp7 project pvcrops

  • Martínez Moreno, Francisco|||0000-0002-8427-9445
  • Lorenzo Pigueiras, Eduardo
  • Narvarte Fernández, Luis|||0000-0002-6289-7605
  • Moretón Villagrá, Rodrigo
  • Tyutyundzhiev, Nicolay
  • Parra, Iñigo de la
Archivo Digital UPM
Publication Contribución de congreso (ConferenceOutput)

Advanced PV modules inspection using multirotor UAV

  • Tyutyundzhiev, Nicolay
  • Lovchinov, K.
  • Martínez Moreno, Francisco|||0000-0002-8427-9445
  • Leloux, Jonathan
  • Narvarte Fernández, Luis|||0000-0002-6289-7605
Archivo Digital UPM
Publication Contribución de congreso (ConferenceOutput)

Tools for the high penetration of PV Systems in the EU electrical networks: results of PVCROPS Project

  • Narvarte Fernández, Luis|||0000-0002-6289-7605
  • Marroyo Palomo, Luis
  • Collares Pereira, Manuel
  • Tyutyundzhiev, Nicolay
  • Conlon, Michael
  • Bouzzan, N.
  • Guelbenzu Michelena, Eugenio
  • González, R.
  • Desportes, Adrien
  • Simmonds, Gary
  • Wilkin, Benjamin
Archivo Digital UPM
Publication Contribución de congreso (ConferenceOutput)

Comparative study of nonparametric and parametric PV models to forecast AC power output of PV plants

  • Almeida, Marcelo Pinho
  • Muñoz, Mikel
  • Parra, Iñigo de la
  • Perpiñan Lamigueiro, Oscar|||0000-0002-4134-7196
  • Narvarte Fernández, Luis|||0000-0002-6289-7605
Archivo Digital UPM
Publication Contribución de congreso (ConferenceOutput)

Using a nonparametric PV model to forecast AC power output of PV plants

  • Almeida, Marcelo Pinho
  • Perpiñan Lamigueiro, Oscar|||0000-0002-4134-7196
  • Narvarte Fernández, Luis|||0000-0002-6289-7605
Archivo Digital UPM
Publication Contribución de congreso (ConferenceOutput)

Use of PV plants monitoring to characterize PV arrays power

  • Carrillo Salinas, José Manuel
  • Martínez Moreno, Francisco|||0000-0002-8427-9445
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publication Contribución de congreso (ConferenceOutput)

Technical specifications and quality control procedures for reducing the uncertainty in PV installations: results of the FP7 project PVCROPS

  • Martínez Moreno, Francisco
  • Lorenzo Pigueiras, Eduardo
  • Narvarte Fernández, Luis
  • Moretón Villagra, Rodrigo
  • Tyutyundzhiev, Nicolay
  • Parra Laita, Íñigo de la
Trabajo presentado a la 31st European Photovoltaic Solar Energy Conference and Exhibition (EU PVSEC). Hamburgo, 2015., Incluye póster, PVCROPS (PhotoVoltaic Cost r€duction, Reliability, Operational performance, Prediction and Simulation) is a project within the European Framework Programme 7 whose objectives are: improving the performance, reliability and lifetime of PV systems; reducing the cost of PV systems; and enhancing the integration of PV into the grid. The main way to reduce the initial costs of a PV installation involves an optimal design and subsequent construction. As a consequence, this optimization leads to a higher performance and to a lower levelized cost of electricity from PV. PVCROPS Work Package 2 and Work Package 9 have been conceived to achieve some of these objectives by proposing both an optimization of the design, to avoid undesirable initial mistakes that can make more expensive the cost of the installation, and a quality control of PV systems, to ensure the final installation matches the one designed initially and that it is able to overcome production requirements. This paper presents one of the main results of these work packages: a document that reflects the accumulated experience in the field by the PVCROPS team about actual PV installations and which contains, first, a general proposal of technical specifications for grid-connected PV systems and, second, the corresponding quality control procedures to check if the installation fulfills the technical specifications previously established. This document has also a report about a comparison between available PV energy performance models and a proposal about how to face the hot-spot problem within commercial frameworks., This work has been cofinanced by the European Commission in the frame of Seventh Framework Programme, in the context of the PVCROPS project [5] (PhotoVoltaic Cost r€duction, Reliability, Operational performance, Prediction and Simulation), contract No. 308468
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publication Contribución de congreso (ConferenceOutput)

Comparative study of nonparametric and parametric PV models to forecast AC power output of PV plants

  • Almeida, Marcelo Pinho
  • Muñoz Escribano, Mikel
  • Parra Laita, Íñigo de la
  • Perpiñán, Óscar
  • Narvarte Fernández, Luis
Trabajo presentado a la 31st European Photovoltaic Solar Energy Conference and Exhibition (EU PVSEC). Hamburgo, 2015., Incluye póster, In this paper, a comparison between two approaches to predict the AC power output of PV systems is carried out in terms of forecast performance. Each approach uses one of the two main types of PV modeling, parametric and nonparametric, and both use as inputs several forecasts of meteorological variables from a Numerical Weather Prediction model. Furthermore, actual AC power measurements of a PV plant are used to train the nonparametric model, to adjust the parameters of the different PV components models used in the parametric approach and to assess the quality of the forecasts. The approaches presented similar behavior, although the nonparametric approach, based on Quantile Regression Forests, showed smaller biased errors due to the machine learning tool used., This work has been partially financed by the Seventh Framework Programme of the European Commission with the Project Photovoltaic Cost Reduction, Reliability, Operational Performance, Prediction and Simulation (PVCROPS—Grant Agreement No. 308468).
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publication Contribución de congreso (ConferenceOutput)

Tools for the high penetration of PV systems in the EU electrical networks: results of PVCROPS Project

  • Narvarte Fernández, Luis
  • Marroyo Palomo, Luis
  • Collares Pereira, Manuel
  • Tyutyundzhiev, Nicolay
  • Conlon, Michael
  • Bouzzan, N.
  • Guelbenzu Michelena, Eugenio
  • González Senosiain, Roberto
  • Desportes, Adrien
  • Simmonds, Gary
  • Wilkin, Benjamin
Trabajo presentado a la 31st European Photovoltaic Solar Energy Conference and Exhibition (EU PVSEC). Hamburgo, 2015., The Solar Energy Industrial Initiative established the objective of integrating PV into the grid to provide up to 12% of the EU electricity demand. The FP7 project PVCROPS has developed solutions to allow the high penetration of PV systems in EU electrical networks and to reduce its Levelized Cost (LCoE) increasing PV system performance. The solutions consist of documents like technical specifications and toolboxes for design, prediction, integration of batteries and automatic detection of performance failures. Six of them are on-line free tools and thirteen are marketable products. These tools allow reducing the LCoE up to 30%, increasing the Performance Ratio up to 9% and PV penetration of 30%. The tools developed by PVCROPS are detailed in www.pvcrops.eu., This work has been partially supported by European Commission within the project PV CROPS (Photovoltaic Cost r€duction, Reliability, Operational performance, Prediction and Simulation) under the 7th Framework Program (Grant Agreement no. 308468).