Two-port networks to model galvanic coupling for intrabody communications and power transfer to implants

  • Ivorra Cano, Antoni, 1974-
  • Becerra Fajardo, Laura
  • Tudela Pi, Marc
  • Ivorra Cano, Antoni, 1974-
Comunicació presentada a: BioCAS 2018, celebrada a Cleveland, Ohio, Estats Units d'Amèrica, del 17 al 19 d'octubre de 2018., Galvanic coupling, or more precisely, volume conduction, can be used to communicate with and to transfer power to electronic implants. Since no bulky components for power, such as coils or batteries, are required within the implants, this strategy can yield very thin devices suitable for implantation by injection. To design the circuitry of both the implants and the external systems, it is desirable to possess a model that encompasses the behavior of these circuits and also the volume conduction phenomenon. Here we propose to model volume conduction with a two-port network so that the whole system can be studied in circuit simulators. The two-port network consists only of three impedances whose values can be obtained through simple measurements or through numerical methods. We report a validation of this modeling approach in a geometrically simple in vitro setup that allowed us to determine the impedances of the two-port network not only by performing measurements or through a finite element method study but also through an analytical solution., Research Council (ERC) under the European Union’s Horizon 2020 research and innovation programme (grant agreement No 724244).
Repositorio Digital de la UPF
Publication Contribución de congreso (ConferenceOutput)

Injectable temperature sensors based on passive rectification of volume-conducted currents

  • Becerra Fajardo, Laura
  • García-Moreno, Aracelys
  • Alvarez de Eulate Llano, Nerea
  • Ivorra Cano, Antoni, 1974-
Comunicació presentada a: 2021 IEEE Biomedical Circuits and Systems Conference (BioCAS), celebrat del 6 al 9 d'octubre de 2021 virtualment, In situ monitoring of biomedical parameters with implantable sensors can provide information to trigger interventional or therapeutic actions. However, these sensors require bulky components for power or for interrogation that hinder miniaturization. We have proposed a wireless sensing method based in passive rectification of high frequency current bursts that flow through the tissues by volume conduction. Here we report the evaluation of a 0.98 mm-thick, passive, and flexible temperature sensor based on this method. The injectable microsensor obtained an accuracy of ±2.1%. This opens the possibility of continuous and in situ temperature sensing with minimal invasiveness., This project has received funding from the European Research Council (ERC) under the European Union’s Horizon 2020 research and innovation programme (grant agreements No 724244 (eAXON) and 963955 (SENSO-eAXON)), and the UPF INNOValora programme, which is co-financed by the Generalitat de Catalunya and the European Regional Development Fund. Antoni Ivorra gratefully acknowledges the financial support by ICREA under the ICREA Academia programme.
Repositorio Digital de la UPF
Publication Contribución de congreso (ConferenceOutput)

Powering implants by Galvanic coupling: a validated analytical model predicts powers above 1 mW in injectable implants

  • Tudela Pi, Marc
  • Becerra Fajardo, Laura
  • Ivorra Cano, Antoni, 1974-
Comunicació presentada a: World Congress on Medical Physics and Biomedical Engineering 2018, celebrat del 3 al 8 de juny de 2018 a Praga, República Txeca., While galvanic coupling for intrabody communications has been proposed lately by different research groups, its use for powering active im-plantable medical devices remains almost non-existent. Here it is presented a simple analytical model able to estimate the attainable power by galvanic cou-pling based on the delivery of high frequency (> 1MHz) electric fields applied as short bursts. The results obtained with the analytical model, which is in vitro validated in the present study, indicate that time-averaged powers above 1 mW can be readily obtained in very thin (diameter < 1 mm) and short (length < 20 mm) elongated implants when fields which comply with safety standards (SAR < 10 W/kg) are present in the tissues where the implants are located. Re-markably, the model indicates that, for a given SAR, the attainable power is in-dependent of the tissue conductivity and of the duration and repetition frequen-cy of the bursts. This study reveals that galvanic coupling is a safe option to power very thin active implants, avoiding bulky components such as coils and batteries., This project has received funding from the European Research Council (ERC) under the European Union’s Horizon 2020 research and innovation programme (grant agreement No 724244).
Repositorio Digital de la UPF
Publication Contribución de congreso (ConferenceOutput)

Networks of injectable microdevices powered and digitally linked by volume conduction for neuroprosthetics: a proof-of-concept

  • Becerra Fajardo, Laura
  • Minguillon, Jesus
  • Comerma-Montells, Albert
  • Ivorra Cano, Antoni, 1974-
Comunicació presentada a 11th International IEEE/EMBS Conference on Neural Engineering (NER 2023), celebrada del 24 al 27 d'abril de 2023 a Baltimore, Estats Units., Wireless power transfer (WPT) methods such as inductive coupling and ultrasounds are used as an alternative to electrochemical batteries to energize active implantable medical devices. However, existing WPT methods require the use of bulky components (e.g., coils) that hinder miniaturization. To avoid this, we proposed the use of volume conduction of high frequency (HF) current bursts to power and bidirectionally communicate with threadlike implants that can be used for electrical stimulation and sensing (e.g., electromyography acquisition). Here, we in vitro demonstrate that several wireless devices can be powered and digitally linked by volume conduction. Eleven devices were randomly placed in a saline medium and were enclosed by two electrodes connected to an external system. The system interrogated the devices, and the waveforms obtained by the external system's demodulator were digitally processed to decode the information sent by the devices through the same HF current bursts. Data was successfully decoded from the devices, independently of the power that each single device obtained. The WPT efficiency of volume conduction boosts when a massive number of devices are powered with a single external system, creating a network of microdevices for neuroprosthetics. This will allow to accomplish closed-loop control for neural interphases using highly miniaturized injectable devices., This work has received funding from the European Research Council (ERC) - European Union’s Horizon 2020 research and innovation programme under grant agreement No. 724244 (eAXON) and from the European Union’s Horizon 2020 research and innovation programme under grant agreement No. 779982 (Project EXTEND - Bidirectional Hyper-Connected Neural System). AI gratefully acknowledges the financial support by ICREA under the ICREA Academia programme.
Repositorio Digital de la UPF
Publication Contribución de congreso (ConferenceOutput)

First steps towards an implantable electromyography (EMG) sensor powered and controlled by Galvanic coupling

  • Becerra Fajardo, Laura
  • Ivorra Cano, Antoni, 1974-
Comunicació presentada a: World Congress on Medical Physics and Biomedical Engineering 2018, celebrat del 3 al 8 de juny de 2018 a Praga, República Txeca., In the past it has been proposed to use implanted electromyography (EMG) sensors for myoelectric control. In contrast to surface systems, these implanted sensors provide signals with low cross-talk. To achieve this, minia-ture implantable devices that acquire and transmit real-time EMG signals are necessary. We have recently in vivo demonstrated electronic implants for elec-trical stimulation which can be safely powered and independently addressed by means of galvanic coupling. Since these implants lack bulky components as coils and batteries, we anticipate it will be possible to accomplish very thin im-plants to be massively deployed in tissues. We have also shown that these de-vices can have bidirectional communication. The aim of this work is to demon-strate a circuit architecture for embedding EMG sensing capabilities in our gal-vanically powered implants. The circuit was simulated using intramuscular EMG signals obtained from an analytical infinite volume conductor model that used a similar implant configuration. The simulations showed that the proposed analog front-end is compatible with the galvanic powering scheme and does not affect the implant’s ability to perform electrical stimulation. The system has a bandwidth of 958 Hz, an amplification gain of 45 dB, and an output-referred noise of 160 μVrms. The proposed embedded EMG sensing capabilities will boost the use of these galvanically powered implants for diagnosis, and closed-loop control., This project has received funding from the European Research Council (ERC) under the European Union’s Horizon 2020 research and innovation programme (grant agreement No 724244).
Recercat. Dipósit de la Recerca de Catalunya
Publication Contribución de congreso (ConferenceOutput)

Two-port networks to model galvanic coupling for intrabody communications and power transfer to implants

  • Ivorra Cano, Antoni, 1974-
  • Becerra Fajardo, Laura
  • Tudela Pi, Marc
  • Ivorra Cano, Antoni, 1974-
Comunicació presentada a: BioCAS 2018, celebrada a Cleveland, Ohio, Estats Units d'Amèrica, del 17 al 19 d'octubre de 2018., Galvanic coupling, or more precisely, volume conduction, can be used to communicate with and to transfer power to electronic implants. Since no bulky components for power, such as coils or batteries, are required within the implants, this strategy can yield very thin devices suitable for implantation by injection. To design the circuitry of both the implants and the external systems, it is desirable to possess a model that encompasses the behavior of these circuits and also the volume conduction phenomenon. Here we propose to model volume conduction with a two-port network so that the whole system can be studied in circuit simulators. The two-port network consists only of three impedances whose values can be obtained through simple measurements or through numerical methods. We report a validation of this modeling approach in a geometrically simple in vitro setup that allowed us to determine the impedances of the two-port network not only by performing measurements or through a finite element method study but also through an analytical solution., Research Council (ERC) under the European Union’s Horizon 2020 research and innovation programme (grant agreement No 724244).
Recercat. Dipósit de la Recerca de Catalunya
Publication Contribución de congreso (ConferenceOutput)

First steps towards an implantable electromyography (EMG) sensor powered and controlled by Galvanic coupling

  • Becerra Fajardo, Laura
  • Ivorra Cano, Antoni, 1974-
Comunicació presentada a: World Congress on Medical Physics and Biomedical Engineering 2018, celebrat del 3 al 8 de juny de 2018 a Praga, República Txeca., In the past it has been proposed to use implanted electromyography (EMG) sensors for myoelectric control. In contrast to surface systems, these implanted sensors provide signals with low cross-talk. To achieve this, minia-ture implantable devices that acquire and transmit real-time EMG signals are necessary. We have recently in vivo demonstrated electronic implants for elec-trical stimulation which can be safely powered and independently addressed by means of galvanic coupling. Since these implants lack bulky components as coils and batteries, we anticipate it will be possible to accomplish very thin im-plants to be massively deployed in tissues. We have also shown that these de-vices can have bidirectional communication. The aim of this work is to demon-strate a circuit architecture for embedding EMG sensing capabilities in our gal-vanically powered implants. The circuit was simulated using intramuscular EMG signals obtained from an analytical infinite volume conductor model that used a similar implant configuration. The simulations showed that the proposed analog front-end is compatible with the galvanic powering scheme and does not affect the implant’s ability to perform electrical stimulation. The system has a bandwidth of 958 Hz, an amplification gain of 45 dB, and an output-referred noise of 160 μVrms. The proposed embedded EMG sensing capabilities will boost the use of these galvanically powered implants for diagnosis, and closed-loop control., This project has received funding from the European Research Council (ERC) under the European Union’s Horizon 2020 research and innovation programme (grant agreement No 724244).
Recercat. Dipósit de la Recerca de Catalunya
Publication Contribución de congreso (ConferenceOutput)

Powering implants by Galvanic coupling: a validated analytical model predicts powers above 1 mW in injectable implants

  • Tudela Pi, Marc
  • Becerra Fajardo, Laura
  • Ivorra Cano, Antoni, 1974-
Comunicació presentada a: World Congress on Medical Physics and Biomedical Engineering 2018, celebrat del 3 al 8 de juny de 2018 a Praga, República Txeca., While galvanic coupling for intrabody communications has been proposed lately by different research groups, its use for powering active im-plantable medical devices remains almost non-existent. Here it is presented a simple analytical model able to estimate the attainable power by galvanic cou-pling based on the delivery of high frequency (> 1MHz) electric fields applied as short bursts. The results obtained with the analytical model, which is in vitro validated in the present study, indicate that time-averaged powers above 1 mW can be readily obtained in very thin (diameter < 1 mm) and short (length < 20 mm) elongated implants when fields which comply with safety standards (SAR < 10 W/kg) are present in the tissues where the implants are located. Re-markably, the model indicates that, for a given SAR, the attainable power is in-dependent of the tissue conductivity and of the duration and repetition frequen-cy of the bursts. This study reveals that galvanic coupling is a safe option to power very thin active implants, avoiding bulky components such as coils and batteries., This project has received funding from the European Research Council (ERC) under the European Union’s Horizon 2020 research and innovation programme (grant agreement No 724244).
Recercat. Dipósit de la Recerca de Catalunya
Publication Contribución de congreso (ConferenceOutput)

Injectable temperature sensors based on passive rectification of volume-conducted currents

  • Becerra Fajardo, Laura
  • García-Moreno, Aracelys
  • Alvarez de Eulate Llano, Nerea
  • Ivorra Cano, Antoni, 1974-
Comunicació presentada a: 2021 IEEE Biomedical Circuits and Systems Conference (BioCAS), celebrat del 6 al 9 d'octubre de 2021 virtualment, In situ monitoring of biomedical parameters with implantable sensors can provide information to trigger interventional or therapeutic actions. However, these sensors require bulky components for power or for interrogation that hinder miniaturization. We have proposed a wireless sensing method based in passive rectification of high frequency current bursts that flow through the tissues by volume conduction. Here we report the evaluation of a 0.98 mm-thick, passive, and flexible temperature sensor based on this method. The injectable microsensor obtained an accuracy of ±2.1%. This opens the possibility of continuous and in situ temperature sensing with minimal invasiveness., This project has received funding from the European Research Council (ERC) under the European Union’s Horizon 2020 research and innovation programme (grant agreements No 724244 (eAXON) and 963955 (SENSO-eAXON)), and the UPF INNOValora programme, which is co-financed by the Generalitat de Catalunya and the European Regional Development Fund. Antoni Ivorra gratefully acknowledges the financial support by ICREA under the ICREA Academia programme.
Recercat. Dipósit de la Recerca de Catalunya
Publication Contribución de congreso (ConferenceOutput)

Networks of injectable microdevices powered and digitally linked by volume conduction for neuroprosthetics: a proof-of-concept

  • Becerra Fajardo, Laura
  • Minguillon, Jesus
  • Comerma-Montells, Albert
  • Ivorra Cano, Antoni, 1974-
Comunicació presentada a 11th International IEEE/EMBS Conference on Neural Engineering (NER 2023), celebrada del 24 al 27 d'abril de 2023 a Baltimore, Estats Units., Wireless power transfer (WPT) methods such as inductive coupling and ultrasounds are used as an alternative to electrochemical batteries to energize active implantable medical devices. However, existing WPT methods require the use of bulky components (e.g., coils) that hinder miniaturization. To avoid this, we proposed the use of volume conduction of high frequency (HF) current bursts to power and bidirectionally communicate with threadlike implants that can be used for electrical stimulation and sensing (e.g., electromyography acquisition). Here, we in vitro demonstrate that several wireless devices can be powered and digitally linked by volume conduction. Eleven devices were randomly placed in a saline medium and were enclosed by two electrodes connected to an external system. The system interrogated the devices, and the waveforms obtained by the external system's demodulator were digitally processed to decode the information sent by the devices through the same HF current bursts. Data was successfully decoded from the devices, independently of the power that each single device obtained. The WPT efficiency of volume conduction boosts when a massive number of devices are powered with a single external system, creating a network of microdevices for neuroprosthetics. This will allow to accomplish closed-loop control for neural interphases using highly miniaturized injectable devices., This work has received funding from the European Research Council (ERC) - European Union’s Horizon 2020 research and innovation programme under grant agreement No. 724244 (eAXON) and from the European Union’s Horizon 2020 research and innovation programme under grant agreement No. 779982 (Project EXTEND - Bidirectional Hyper-Connected Neural System). AI gratefully acknowledges the financial support by ICREA under the ICREA Academia programme.