Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 7
Encontrada(s) 1 página(s)

TECNALIA Publications
Publication Contribución de congreso (ConferenceOutput)

Simulation of unglazed solar thermal systems integrated into façade & combined with ultra-low temperature district heating

  • Lumbreras, Mikel
  • Garay, Roberto
This paper presents a theoretical simulation of thermal and economical assessment of façade integrated Solar Thermal (ST) in combination with Ultra Low Temperature (ULT) District-Heating (DH). This paper is in line with existing R&D activities for the integration of unglazed systems in building envelopes, where facades provide an almost unexplored area for increasing solaractivated building envelopes. The combination of building-integrated solar systems with DH networks avoids the use of local storage and allows a novel combination of heat directionality, both from building to the heat grid and vice versa. A control algorithm for heat supply is presented, so that the performance of the overall system is the optimal. Energetic results from solar simulations and economic assessment derived from the balance of building energy demand and solar production are presented. Over a fullyear period the proposed unglazed system produces as much as 50% additional heat when compared with an isolated ST system and profitable economic metrics are reached over a simulation time of 20 years. Finally, it is concluded the heat sink nature of a DH network, for as many as 25-35% of the buildings connected to the DH includes ST system.
TECNALIA Publications
Publication Contribución de congreso (ConferenceOutput)

Energy meters in District-Heating Substations for Heat Consumption Characterization and Prediction Using Machine-Learning Techniques

  • Lumbreras, Mikel
  • Garay, Roberto
  • Marijuan, Antonio Garrido
The use of smart energy meters enables the monitoring of large quantity of data related to heat consumption patterns in buildings connected to DH networks. This information can be used to understand the interaction between building and the final users´ without accurate information about building characteristics and occupational rates. In this paper an intuitive and clarifier data-driven model is presented, which couples heat demand and weather variables. This model enables the disaggregation of Space-Heating & Domestic Hot water demand, characterization of the total heat demand and the forecasting for the next hours. Simulations for 53 building have been carried out, with satisfactory results for most of them, reaching R2 values above 0.9 in some of them.
TECNALIA Publications
Publication Contribución de congreso (ConferenceOutput)

RELaTED, decentralized & renewable Ultra Low Temperature District Heating, concept conversion from traditional district heating

  • Lumbreras Mugaguren, Mikel
  • Garay, Roberto
  • Sánchez Zabala, Víctor
  • Garay Martínez, Roberto
District Heating (DH) are a very efficient system for heating in urban areas and they are considered as key elements for the de-carbonization of the European Cities. High performance levels and low operational energy costs are part of the identity of these heating networks. The reduction of supply-line temperatures allows the possibility to introduce new low-grade and renewable source energy production, reducing dependence on fossil fuel-based energy plants. Moreover, heat-losses in distribution pipelines are also reduced, since the gradient temperature between supply line and ambient temperature is reduced. Operation of decentralized & Ultra Low Temperature (ULT) systems may adapt for the introduction of weather-dependent, distributed heat sources such as solar systems. Furthermore, although very dependent on local availability, waste heat streams from commercial and industrial installations are also considered because of the stability of heat supply all year round, resulting in minimally carbon intensive processes. Regarding building features, the reduced heat load derived from the transition from current buildings to Nearly Zero Energy Buildings (NZEB), RELaTED allows for the novel concept called prosumer, where buildings can deliver energy to the grid from decentralized energy sources installed in the building. In RELaTED, different subsystems are being developed by different industrial partners, to prove their efficiency in 4 real demonstration sites: Tartu (Estonia), Belgrade (Serbia), Vinge (Denmark) and Iurreta (Spain). A 3-FS (3-Function Scheme) DH substation that permits buildings to become prosumers. Two types of solar collectors, one is an all polymeric glazed collector and the second one is an unglazed collector, both as components of Building Integrated Large Solar Thermal Systems (BILSTS) solar loop. Finally, a reversible and high efficiency heat pump for domestic hot water is being developed. In this paper, an approach to ULT concept is studied, including transitory phases of the conversion.
TECNALIA Publications
Publication Contribución de congreso (ConferenceOutput)

Integration of Renewables in DHC for Sustainable Living Workshop

  • Vázquez, María Victoria Cambronero
  • Corscadden, Jack
  • Marijuan, Antonio Garrido
  • Barbagelata, Giulia
  • Hamann, Georg
  • Grosjean, Matthieu
  • Mendoza, Nora
There is a large potential to integrate substantial shares of renewable energy and waste heat sources in district heating and/or cooling networks (DHC), reducing dependency of DHC on fossil fuels and ultimately leading to a more efficient and sustainable energy system. Several EU funded projects are currently working on this topic. The objective of the workshop aimed to share the WEDISTRICT project concept with other sister projects and interested stakeholders in order to exchange new ideas, lessons learnt from implementation and proposals about the successful integration of renewable technologies in DHC and urban regeneration.
TECNALIA Publications
Publication Contribución de congreso (ConferenceOutput)

DESIGN OF CONSUMMER THERMAL SUBSTATIONS FOR THE INTEGRATION OF DISTRIBUTED SOLAR TECHNOLOGIES IN DISTRICT HEATING SYSTEMS

  • Sánchez Zabala, Víctor
  • Garay, Roberto
In most cases, building service designers choose between Solar thermal (ST) and District Heating (DH) technologies for their integration in buildings. By doing so, only a fraction of the buildings within a particular district is used for ST, while at the same time energy intensity in DH networks can be reduced. In some cases, building-integrated solar thermal systems are connected to DH networks by means of dedicated pipes. In all these cases, sub-optimal situations are reached with lower fraction of renewable heat, reduced network strength and/or additional heat losses. In this paper, a consummer substation concept is proposed with reversible heat flow and net metering, which avoids local thermal storage in the solar loop. Adaptations required for multi-dwelling buildings are presented.
TECNALIA Publications
Publication Contribución de congreso (ConferenceOutput)

RELATED, A FLEXIBLE APPROACH TO THE DEPLOYMENT AND CONVERSION OF DH NETWORKS TO LOW TEMPERATURE, WITH INCREASED USE OF LOCAL SOLAR SYSTEMS

  • Garay, Roberto
  • Sánchez Zabala, Víctor
District heating (DH) systems are key systems for the de-carbonization of heating energy in European Cities. In order to allow for this transition, while guaranteeing competitive energy costs, conversion of DHs is required. DH operation temperature needs to be reduced in order to increase the performance of renewable systems and operation criteria needs to be adopted for the introduction of weather-dependent, distributed heat sources such as solar systems. This paper presents the RELaTED decentralized Ultra-Low Temperature DH network scheme, and its adaptation to several operational schemes such as new and existing DH networks, with different levels of complexity. Transitory phases in the conversion process are discussed.
TECNALIA Publications
Publication Contribución de congreso (ConferenceOutput)

Data driven process for the energy assessment of building envelope retrofits

  • Garay-Martinez, Roberto
  • Arregi, Beñat
  • Lumbreras, Mikel
  • Zurro, Belén
  • Gonzalez, Jose Manuel
  • Hernandez, Jose Luis
In the last decades, a growing industry has been created in relation to building envelope retrofits. Linked to the lack of financial capacity of many building owners, innovative instruments such as energy performance contracts have been promoted by public bodies. This kind of instruments require of detailed energy assessment processes in order to define the expected heat load reduction and the associated economic flows between building owners and Energy Services Companies. When dealing with building envelopes, existing methods for building envelope heat loss characterization require of substantial efforts in terms of equipment and time, which makes them difficult to apply in real practice. In this paper, a novel method is proposed based on whole-building heat load assessment by means of heat meters, and analytical calculations of building envelope transmission heat load coefficients. This method, which requires minimal or no additional equipment, can be used over historical data from District Heating systems. It assigns a specific load fraction to building envelope heat transfer and allows to assess the expected reduction due to the building envelope retrofit. Numerical and experimental data is presented based on an educational building in the city of Burgos, Spain.