Skip to main content

DINAMICA Y MODULACION DE RITMOS DE LA RED CORTICAL EN DIFERENTES ESTADOS CEREBRALES

BFU2011-27094

•
Funding agency name Ministerio de Ciencia e Innovación
Funding agency acronym MICINN
Program Programa Nacional de Proyectos de Investigación Fundamental
Subprogram Subprograma de Proyectos de Investigación Fundamental no Orientada
Call Proyectos I+D
Call year 2011
State Plan 2008-2011 Plan Nacional de Investigación Científica, Desarrollo e Innovación Tecnológica
Management unit Subdirección General de Proyectos de Investigación
Beneficiary centre CONSORCI INSTITUT D INVESTIGACIONS BIOMEDIQUES AUGUST PI I SUNYER

Resultados relacionados

Resultados totales (Incluyendo duplicados): 1
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

A SU-8-based flexible microprobe for close and distal recordings from the cortical network

  • Illa, Xavi
  • Rebollo, Beatriz
  • Gabriel, Gemma
  • Sánchez-Vives, Maria V.
  • Villa, Rosa
A 16-electrode flexible microprobe presenting an array of holes in its sensing area has been developed using SU-8 negative photoresist as a substrate material. The design of the microprobe consisted on six groups of 2-3 electrodes (50 μm in diameter and separated by 200 μm) placed in-between the array of holes. Distances between each group were appropriated for recording from a ferret slice, allowing us to evaluate the close versus the distant network activity. The holes were designed to allow the flow of oxygenated solution through the probe when measuring the neural activity of cortical slides maintained in vitro, while the gold electrodes have been modified with platinum black to decrease its impedance value and, therefore, improve the measurements. In particular, with this SU-8 microprobe it has been possible to register spontaneous slow oscillations and also induced activity in all 16 channels. The holes were useful to position puffers that allowed us to locally delivered drugs (glutamate) and to register its response. In addition, they were also used for sticking electrodes to simultaneously record single units that allowed us the synchronous recording of population activity (local field potential) with the electrodes of the probe and single unit activity (with glass or tungsten electrodes), demonstrating the feasibility of using SU-8 for the fabrication of neural microprobes as it can be customized to the required design., This work has been supported by the Spanish Ministry of Economy and Competitiveness, BFU2011-27094 (MVSV) and SAF2012-40227- C02-02 (RV), the European Regional Development Fund (RV), EU project CORTICONIC (Contract number 600806, MVSV) and the Graphene Flagship Initiative of the European Commision via the NEUROGRAPHENE project (Contract 604391, MVSV and RV)., Peer reviewed