Airborne ultrasounds for damaged cementitious characterization
[EN] The scope of this paper is to demonstrate the capability of airborne non-contact ultrasound
(ANC-US) to assess thermal damage on normalized Portland cement mortar specimens. For
this purpose, contact ultrasound (C-US) and ANC-US are compared. A normalized dosage
mortar was carried out to obtain standardized mortar specimens of 4 x 4 x 16 cm. Then, they
were measured by ANC-US and C-US. Afterwards, they were thermal damaged (400º C) and
measured again. Ultrasound velocity and frequency attenuation were estimated. As expected,
damaged samples show lower velocities and higher attenuations than sound samples. It is
remarkable how the attenuation keeps constant for frequencies below 100 kHz and increases
due to the sensitivity of higher frequencies to the size of thermal microcracking.
Although ANC-US does not require any coupling media as C-US does, it requires additional
calibration to compensate propagation through the air and material boundaries. Considering
these terms, both techniques offer consistent results and the capability of ANC-US technique
for damage characterization in cementitious systems is proved., The authors acknowledge the support from T. Gomez Álvarez-Arenas (Institute for Physical
and Information Technologies ITEFI-CSIC) and Spanish Administration under grant BIA2017-
87573.