Skip to main content

IMPLANTES OPTICOS INTRAOCULARES CORRECTORES DE LA PRESBICIA PARA UNA COMPENSACION VISUAL PERSONALIZADA

PID2020-114582RB-I00

•
Funding agency name Agencia Estatal de Investigación
Funding agency acronym AEI
Program Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Call Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Call year 2020
State Plan 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Beneficiary centre UNIVERSITAT POLITECNICA DE CATALUNYA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 13
Encontrada(s) 1 página(s)

UPCommons. Portal del coneixement obert de la UPC
Publication Contribución de congreso (ConferenceOutput)

20/21 Central Event in Spain of the International Day of Light: outreach and citizen engagement in time of pandemic

  • Pérez Cabré, Elisabet|||0000-0003-4244-4235
  • Millán Garcia-Varela, M. Sagrario|||0000-0001-6950-2373
  • Armengol Cebrian, Jesús|||0000-0003-2880-752X
The 3rd central IDL Event in Spain probably gathered the largest number of activities for the 16th May commemoration in 2021. Conferences, debates, workshops, exhibitions, light shows, and photo contests, adapted to severe constraints due to the pandemic, achieved the participation of a wide and diverse audience.
UPCommons. Portal del coneixement obert de la UPC
Publication Contribución de congreso (ConferenceOutput)

Focus-tunable lens with gravity-compensation. Wavefront analysis

  • Pérez Cabré, Elisabet|||0000-0003-4244-4235
  • Cuéllar Santiago, Fátima|||0009-0003-2019-7189
  • Clavé Cerezo, Laura|||0000-0001-9483-488X
  • Millán Garcia-Varela, M. Sagrario|||0000-0001-6950-2373
An electrically-addressed focus-tunable lens (FTL) enables fine, continuous, and dynamic power adjustment across a range of diopters. This lens encloses an optical fluid within a sealed container with an elastic membrane. An electromagnetic actuator applies pressure to the container, altering the curvature of the lens. This study investigates the optical performance of a gravity-compensated FTL (Optotune EL-16-40-GTC-VIS5D) in terms of the addressed optical power and measured wavefront error, in both horizontal and vertical lens orientation. The results were compared with two standard, uncompensated models from the same manufacturer. All the analysed FTLs demonstrated excellent optical power performance regardless of orientation. The gravity-compensated FTL effectively corrected vertical coma in the upright orientation, but induced greater astigmatism compared to the standard models. These findings provide valuable insights for vision testing and adaptive optics applications., Authors thank the Spanish Agencia Estatal de Investigación for financial support (PID2020-114582RB-I00/ AEI/10.13039/501100011033)., Peer Reviewed, 3 - Salut i Benestar, 9 - Indústria, Innovació i Infraestructura
UPCommons. Portal del coneixement obert de la UPC
Publication Contribución de congreso (ConferenceOutput)

Skin color correction via convolutional neural networks in 3D fringe projection profilometry

  • Barrios Montes, Erik Miguel
  • Pineda, Jesús
  • Romero Pérez, Lenny Alexandra
  • Millán Garcia-Varela, M. Sagrario|||0000-0001-6950-2373
  • Marrugo Hernandez, Andrés Guillermo
Fringe Projection Profilometry (FPP) with Digital Light Projector technology is one of the most reliable 3D sensing techniques for biomedical applications. However, besides the fringe pattern images,often a color texture image is needed for an accurate medical documentation. This image may be acquired either by projecting a white image or a black image and relying on ambient light. Color Constancy is essential for a faithful digital record, although the optical properties of biological tissue make color reproducibility challenging. Furthermore, color perception is highly dependent on the illuminant. Here, we describe a deep learning-based method for skin color correction in FPP. We trained a convolutional neural network using a skin tone color palette acquired under different illumination conditions to learn the mapping relationship between the input color image and its counterpart in the sRGB color space. Preliminary experimental results demonstrate the potential for this approach., The authors acknowledge the financial support from the Universidad Technológica de Bolívar (project CI2021P04) and the Centre de Cooperació i Desenvolupament (CCD) at the Universitat Politècnica de Catalunya (project CCD 2020-B014). E. Barrios thanks Minciencias and Sistema General de Regalías (Programa de Becas de Excelencia) for a PhD scholarship., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publication Contribución de congreso (ConferenceOutput)

Performance of gravity-compensated focus-tunable lens

  • Cuéllar Santiago, Fátima|||0009-0003-2019-7189
  • Pérez Cabré, Elisabet|||0000-0003-4244-4235
  • Clavé Cerezo, Laura|||0000-0001-9483-488X
  • Millán Garcia-Varela, M. Sagrario|||0000-0001-6950-2373
An electrically controlled focus-tunable lens (FTL) allows for precise, continuous, and dynamic power adjustment over a range of diopters. While the FTLs are often positioned horizontally with a vertically aligned optical axis, certain applications require alternative orientations, which can introduce coma aberration due to gravitational effects on the optical fluid and elastic membrane of the device. This study examines the optical performance of a newly designed gravity-compensated FTL (Optotune EL-16-40-GTC-VIS-5D) by evaluating its addressed optical power and measured wavefront error, in both horizontal and vertical lens orientation. The results were compared to two standard, non-compensated models from the same manufacturer. All tested FTLs exhibited excellent optical power performance regardless of orientation, while the gravity-compensated model effectively corrected vertical coma when positioned upright., This work has been sponsored by the Agencia Estatal de Investigación (PID2020-114582RB-I00/AEI/10.13039/501100011033), Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publication Contribución de congreso (ConferenceOutput)

Cambios en la vision del color con óptica difractiva, Color vision change with diffractive ophthalmic optics

  • Clavé Cerezo, Laura|||0000-0001-9483-488X
  • Faria Ribeiro, Miguel
  • Millán Garcia-Varela, M. Sagrario|||0000-0001-6950-2373
La óptica difractiva es una técnica valiosa para diseñar lentes correctoras de la presbicia, pero su eficacia depende de la longitud de onda. Este estudio investiga las alteraciones espacio-cromáticas en la resolución visual asociadas a las lentes multifocales difractivas mediante el uso de lentes de contacto bifocales difractivas. El estudio combina el análisis teórico, la simulación numérica y experimentos clínicos intra-observador para evaluar la agudeza visual en diversas condiciones de iluminación. Los resultados demuestran una asimetría espacio-cromática y un cambio en la agudeza visual bajo iluminación roja y azul, dependiendo del orden de difracción empleado en el diseño de la lente. La distribución de energía de la lente de contacto difractiva estudiada, favorece la resolución espacial bajo iluminación roja en distancias lejanas y bajo iluminación azul en distancias cercanas. Estos hallazgos son coherentes con las simulaciones computacionales y proporcionan información sobre los cambios visuales inducidos por las lentes oftálmicas difractivas., Diffractive optics is a valuable technique for designing presbyopia-correcting lenses, but its effectiveness is wavelength-dependent. This study investigates the spatio-chromatic alterations in visual resolution associated with diffractive multifocal lenses by using non-invasive, removable diffractive bifocal contact lenses. The study combines theoretical analysis, numerical simulation, and clinical intra-observer experiments to assess visual acuity under various lighting conditions. Results demonstrate the introduction of spatio-chromatic asymmetry and a change in visual acuity under red and blue lights, depending on the operating diffraction order employed in the lens design. The energy distribution of the diffractive contact lens studied favors resolution under red illumination at far distances and under blue illumination at near distances. These findings are consistent with computational simulations and provide insights into the visual changes induced by diffractive ophthalmic lenses., Agradecimientos: (PID2020-114582RB-I00/AEI/10.13039/501100011033)., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publication Contribución de congreso (ConferenceOutput)

Colour and spatial visual function following cataract surgery with diffractive intraocular lens implantation, Función visual espacio-cromática tras la cirugía de catarata con implante de lente intraocular difractiva

  • Millán Garcia-Varela, M. Sagrario|||0000-0001-6950-2373
  • Clavé Cerezo, Laura|||0000-0001-9483-488X
  • Torrents Gómez, Aurora|||0000-0003-2806-7306
  • Armengol Cebrian, Jesús|||0000-0003-2880-752X
  • Vega Lerín, Fidel|||0000-0002-8594-0872
We found asymmetric alterations in the spatio-chromatic vision of subjects implanted with presbyopia-correcting diffractive intraocular lenses, with significant changes in resolution depending on the object distance and the spectral band of the illumination. These alterations can be detected with the methods and materials of the ordinary clinical examination. The alterations depend strongly on the characteristics of the diffractive design, in particular the diffraction orders used for far vision and presbyopia correction and the spectral band of the illumination., Hemos encontrado alteraciones asimétricas en la visión espacio-cromática de sujetos implantados con lentes intraoculares difractivas correctoras de presbicia, que afectan a la resolución en función de la distancia al objeto y la región espectral del iluminante (roja, verde, azul). Estas alteraciones pueden detectarse con los métodos y materiales usuales del examen clínico ordinario. Las alteraciones dependen en gran medida del diseño difractivo, en particular, de los órdenes de difracción utilizados para visión lejana y cercana, así como de la región espectral del iluminante., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publication Contribución de congreso (ConferenceOutput)

Automated corneal endothelium image segmentation in the presence of cornea guttata via convolutional neural networks - 115110H

  • Sierra Bravo, Juan Sebastián
  • Pineda, Jesús
  • Viteri Coronel, Eduardo
  • Rueda Latorre, Daniela
  • Tibaduiza Vargas, Beatriz Eugenia
  • Berrospi, Rubén
  • Tello, Alejandro
  • Galvis Ramírez, Virgilio
  • Volpe, Giovanni
  • Millán Garcia-Varela, M. Sagrario|||0000-0001-6950-2373
  • Romero Pérez, Lenny Alexandra
  • Marrugo Hernandez, Andrés Guillermo
Automated cell counting in in-vivo specular microscopy images is challenging, especially in situations where single-cell segmentation methods fail due to pathological conditions. This work aims to obtain reliable cell segmentation from specular microscopy images of both healthy and pathological corneas. We cast the problem of cell segmentation as a supervised multi-class segmentation problem. The goal is to learn a mapping relation between an input specular microscopy image and its labeled counterpart, indicating healthy (cells) and pathological regions (e.g., guttae). We trained a U-net model by extracting 96 96 pixel patches from corneal endothelial cell images and the corresponding manual segmentation by a physician. Encouraging results show that the proposed method can deliver reliable feature segmentation enabling more accurate cell density estimations for assessing the state of the cornea., This work has been partly funded by the Centre de Cooperació i Desenvolupament (CCD) at the Universitat Politècnica de Catalunya under project ref. CCD 2020-B014., Peer Reviewed
Recercat. Dipósit de la Recerca de Catalunya
Publication Contribución de congreso (ConferenceOutput)

Cambios en la vision del color con óptica difractiva, Color vision change with diffractive ophthalmic optics

  • Clavé Cerezo, Laura
  • Faria Ribeiro, Miguel
  • Millán Garcia-Varela, M. Sagrario
La óptica difractiva es una técnica valiosa para diseñar lentes correctoras de la presbicia, pero su eficacia depende de la longitud de onda. Este estudio investiga las alteraciones espacio-cromáticas en la resolución visual asociadas a las lentes multifocales difractivas mediante el uso de lentes de contacto bifocales difractivas. El estudio combina el análisis teórico, la simulación numérica y experimentos clínicos intra-observador para evaluar la agudeza visual en diversas condiciones de iluminación. Los resultados demuestran una asimetría espacio-cromática y un cambio en la agudeza visual bajo iluminación roja y azul, dependiendo del orden de difracción empleado en el diseño de la lente. La distribución de energía de la lente de contacto difractiva estudiada, favorece la resolución espacial bajo iluminación roja en distancias lejanas y bajo iluminación azul en distancias cercanas. Estos hallazgos son coherentes con las simulaciones computacionales y proporcionan información sobre los cambios visuales inducidos por las lentes oftálmicas difractivas., Diffractive optics is a valuable technique for designing presbyopia-correcting lenses, but its effectiveness is wavelength-dependent. This study investigates the spatio-chromatic alterations in visual resolution associated with diffractive multifocal lenses by using non-invasive, removable diffractive bifocal contact lenses. The study combines theoretical analysis, numerical simulation, and clinical intra-observer experiments to assess visual acuity under various lighting conditions. Results demonstrate the introduction of spatio-chromatic asymmetry and a change in visual acuity under red and blue lights, depending on the operating diffraction order employed in the lens design. The energy distribution of the diffractive contact lens studied favors resolution under red illumination at far distances and under blue illumination at near distances. These findings are consistent with computational simulations and provide insights into the visual changes induced by diffractive ophthalmic lenses., Agradecimientos: (PID2020-114582RB-I00/AEI/10.13039/501100011033)., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Contribución de congreso (ConferenceOutput)

Performance of gravity-compensated focus-tunable lens

  • Cuéllar Santiago, Fátima
  • Pérez Cabré, Elisabet
  • Clavé Cerezo, Laura
  • Millán Garcia-Varela, M. Sagrario
An electrically controlled focus-tunable lens (FTL) allows for precise, continuous, and dynamic power adjustment over a range of diopters. While the FTLs are often positioned horizontally with a vertically aligned optical axis, certain applications require alternative orientations, which can introduce coma aberration due to gravitational effects on the optical fluid and elastic membrane of the device. This study examines the optical performance of a newly designed gravity-compensated FTL (Optotune EL-16-40-GTC-VIS-5D) by evaluating its addressed optical power and measured wavefront error, in both horizontal and vertical lens orientation. The results were compared to two standard, non-compensated models from the same manufacturer. All tested FTLs exhibited excellent optical power performance regardless of orientation, while the gravity-compensated model effectively corrected vertical coma when positioned upright., This work has been sponsored by the Agencia Estatal de Investigación (PID2020-114582RB-I00/AEI/10.13039/501100011033), Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Contribución de congreso (ConferenceOutput)

Skin color correction via convolutional neural networks in 3D fringe projection profilometry

  • Barrios Montes, Erik Miguel
  • Pineda, Jesús
  • Romero Pérez, Lenny Alexandra
  • Millán Garcia-Varela, M. Sagrario
  • Marrugo Hernandez, Andrés Guillermo
Fringe Projection Profilometry (FPP) with Digital Light Projector technology is one of the most reliable 3D sensing techniques for biomedical applications. However, besides the fringe pattern images,often a color texture image is needed for an accurate medical documentation. This image may be acquired either by projecting a white image or a black image and relying on ambient light. Color Constancy is essential for a faithful digital record, although the optical properties of biological tissue make color reproducibility challenging. Furthermore, color perception is highly dependent on the illuminant. Here, we describe a deep learning-based method for skin color correction in FPP. We trained a convolutional neural network using a skin tone color palette acquired under different illumination conditions to learn the mapping relationship between the input color image and its counterpart in the sRGB color space. Preliminary experimental results demonstrate the potential for this approach., The authors acknowledge the financial support from the Universidad Technológica de Bolívar (project CI2021P04) and the Centre de Cooperació i Desenvolupament (CCD) at the Universitat Politècnica de Catalunya (project CCD 2020-B014). E. Barrios thanks Minciencias and Sistema General de Regalías (Programa de Becas de Excelencia) for a PhD scholarship., Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publication Contribución de congreso (ConferenceOutput)

Automated corneal endothelium image segmentation in the presence of cornea guttata via convolutional neural networks - 115110H

  • Sierra Bravo, Juan Sebastián
  • Pineda, Jesús
  • Viteri Coronel, Eduardo
  • Rueda Latorre, Daniela
  • Tibaduiza Vargas, Beatriz Eugenia
  • Berrospi, Rubén
  • Tello, Alejandro
  • Galvis Ramírez, Virgilio
  • Volpe, Giovanni
  • Millán Garcia-Varela, M. Sagrario
  • Romero Pérez, Lenny Alexandra
  • Marrugo Hernandez, Andrés Guillermo
Automated cell counting in in-vivo specular microscopy images is challenging, especially in situations where single-cell segmentation methods fail due to pathological conditions. This work aims to obtain reliable cell segmentation from specular microscopy images of both healthy and pathological corneas. We cast the problem of cell segmentation as a supervised multi-class segmentation problem. The goal is to learn a mapping relation between an input specular microscopy image and its labeled counterpart, indicating healthy (cells) and pathological regions (e.g., guttae). We trained a U-net model by extracting 96 96 pixel patches from corneal endothelial cell images and the corresponding manual segmentation by a physician. Encouraging results show that the proposed method can deliver reliable feature segmentation enabling more accurate cell density estimations for assessing the state of the cornea., This work has been partly funded by the Centre de Cooperació i Desenvolupament (CCD) at the Universitat Politècnica de Catalunya under project ref. CCD 2020-B014., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Contribución de congreso (ConferenceOutput)

20/21 Central Event in Spain of the International Day of Light: outreach and citizen engagement in time of pandemic

  • Pérez Cabré, Elisabet
  • Millán Garcia-Varela, M. Sagrario
  • Armengol Cebrian, Jesús
The 3rd central IDL Event in Spain probably gathered the largest number of activities for the 16th May commemoration in 2021. Conferences, debates, workshops, exhibitions, light shows, and photo contests, adapted to severe constraints due to the pandemic, achieved the participation of a wide and diverse audience., Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Contribución de congreso (ConferenceOutput)

Colour and spatial visual function following cataract surgery with diffractive intraocular lens implantation, Función visual espacio-cromática tras la cirugía de catarata con implante de lente intraocular difractiva

  • Millán Garcia-Varela, M. Sagrario
  • Clavé Cerezo, Laura
  • Torrents Gómez, Aurora
  • Armengol Cebrian, Jesús
  • Vega Lerín, Fidel
We found asymmetric alterations in the spatio-chromatic vision of subjects implanted with presbyopia-correcting diffractive intraocular lenses, with significant changes in resolution depending on the object distance and the spectral band of the illumination. These alterations can be detected with the methods and materials of the ordinary clinical examination. The alterations depend strongly on the characteristics of the diffractive design, in particular the diffraction orders used for far vision and presbyopia correction and the spectral band of the illumination., Hemos encontrado alteraciones asimétricas en la visión espacio-cromática de sujetos implantados con lentes intraoculares difractivas correctoras de presbicia, que afectan a la resolución en función de la distancia al objeto y la región espectral del iluminante (roja, verde, azul). Estas alteraciones pueden detectarse con los métodos y materiales usuales del examen clínico ordinario. Las alteraciones dependen en gran medida del diseño difractivo, en particular, de los órdenes de difracción utilizados para visión lejana y cercana, así como de la región espectral del iluminante., Peer Reviewed, Postprint (published version)