Skip to main content

ECOSISTEMA DE SALUD INTELIGENTE PARA EL MANEJO DE ENFERMEDADES RESPIRATORIAS Y OPTIMIZACION DEL SUEÑO EN PACIENTES CON EPOC, COVID Y TRASTORNOS DEL SUEÑO

PID2021-126455OB-I00

•
Funding agency name Agencia Estatal de Investigación
Funding agency acronym AEI
Program Programa Estatal para Impulsar la Investigación Científico-Técnica y su Transferencia
Subprogram Subprograma Estatal de Generación de Conocimiento
Call Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Call year 2021
State Plan 2021-2023 Plan Estatal de Investigación Científica y Técnica y de Innovación
Beneficiary centre FUNDACIO INSTITUT DE BIOENGINYERIA DE CATALUNYA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 4
Encontrada(s) 1 página(s)

UPCommons. Portal del coneixement obert de la UPC
Publication Contribución de congreso (ConferenceOutput)

Entropy analysis of diaphragmatic EMG signals as an indicator of extubation viability in mechanically ventilated patients

  • Arboleda Carvajal, Alejandro|||0000-0001-7161-9175
  • Franco Arias, Manuel
  • Valladares, Liliana
  • Naranjo Junoy, Francisco
  • Giraldo Giraldo, Beatriz|||0000-0002-9910-8577
© 2025 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works., javascript:dpEsborraDadesFormAbstract();Surface electromyographic (sEMG) signals from the diaphragm has become a valuable tool for monitoring muscle activity during the weaning process from mechanical ventilation. However, EMG signals are inherently nonlinear and susceptible to noise contamination, which poses challenges for traditional signal processing methods. In this study, we propose the use of entropy metrics to evaluate the dynamic complexity and irregularity of surface electromyographic (EMG) signals of patients assisted with mechanical ventilation. Shannon entropy and spectral entropy were computed to analyze EMG signals from two surface diaphragm channels recorded in mechanically ventilated patients during extubation preparation. According to clinical criteria, the patients were classified into the successful group (GE) – 19 patients with successful extubation after 48 hours, and the failure group (GF) – 21 patients who required reconnection to the ventilator within 48 hours. sEMG signals were recorded using 5-channel surface electrodes placed around the diaphragm muscle. Shannon and spectral entropies were calculated using a 0.5-minute window with an overlap of 80%. The results presented a greater complexity of the EMG signal in the SG group. This group shows higher peaks in Shannon entropy and elevated spectral entropy values compared to the FG group. Channels 2 and 3 presented the largest statistically significant differences.Clinical Relevance— Analyzing diaphragm EMG signals using entropy metrics could improve patient outcomes by optimizing the timing of extubation. These metrics would serve as a key indicator of readiness for extubation, providing an objective basis for more informed clinical decision-making., Research supported in part by the Universidad UNAB, Bucaramanga, Colombia, in part by the CERCA Program/ Generalitat de Catalunya, in part by the Secretaria d’Universitats i Recerca de la Generalitat de Catalunya GRC 2021 SGR 01390, and in part by the Spanish Ministry of Science and Innovation (PID2021-126455OB-I00 MCIN/AEI/FEDER)., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publication Contribución de congreso (ConferenceOutput)

Measuring high-resolution sleep position in adolescents over 4 nights with smartphone accelerometers

  • Castillo Escario, Yolanda|||0000-0002-7493-1268
  • Blanco Almazán, Dolores
  • Ferrer Lluís, Ignasi
  • Jané Campos, Raimon|||0000-0002-6541-8729
© 2023 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting /republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works, Sleep position affects sleep quality and the severity of different diseases. Classical methods to measure sleep position are complex, expensive, and difficult to use outside the laboratory. Wearables and smartphones can help to address these issues to track sleep position at home over several nights. In this study, we monitor high-resolution sleep position in 13 adolescents over 4 nights using smartphone accelerometer data. We aim to investigate the distribution of sleep positions and position changes in adolescents, study their variability across nights, and propose new measures related to nocturnal body movements. We developed a new index, the mean sleep angle change per hour, and calculated three other measures: position shifts per hour, mean time at each position, and periods of immobility. Our results indicate that participants spent 56% of the time on the side (32% right and 24% left), 32% in supine, and 12% in prone position, similar to what happens in adults. However, adolescents moved more than adults during sleep according to all measures. There was some variability between nights, but lower than the inter-subject variability. In conclusion, this work systematically analyzes sleep position over several nights in adolescents, a largely unstudied population, and offers innovative solutions and measures for high-resolution sleep position monitoring in a simple and cost-effective way.Clinical Relevance— Our study characterizes sleep position in adolescents and provides novel unobtrusive methods and quantitative indices to monitor high-resolution sleep position at home during multiple nights., Peer Reviewed, Objectius de Desenvolupament Sostenible::3 - Salut i Benestar
Recercat. Dipósit de la Recerca de Catalunya
Publication Contribución de congreso (ConferenceOutput)

Entropy analysis of diaphragmatic EMG signals as an indicator of extubation viability in mechanically ventilated patients

  • Arboleda Carvajal, Alejandro
  • Franco Arias, Manuel
  • Valladares, Liliana
  • Naranjo Junoy, Francisco
  • Giraldo Giraldo, Beatriz
© 2025 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works., javascript:dpEsborraDadesFormAbstract();Surface electromyographic (sEMG) signals from the diaphragm has become a valuable tool for monitoring muscle activity during the weaning process from mechanical ventilation. However, EMG signals are inherently nonlinear and susceptible to noise contamination, which poses challenges for traditional signal processing methods. In this study, we propose the use of entropy metrics to evaluate the dynamic complexity and irregularity of surface electromyographic (EMG) signals of patients assisted with mechanical ventilation. Shannon entropy and spectral entropy were computed to analyze EMG signals from two surface diaphragm channels recorded in mechanically ventilated patients during extubation preparation. According to clinical criteria, the patients were classified into the successful group (GE) – 19 patients with successful extubation after 48 hours, and the failure group (GF) – 21 patients who required reconnection to the ventilator within 48 hours. sEMG signals were recorded using 5-channel surface electrodes placed around the diaphragm muscle. Shannon and spectral entropies were calculated using a 0.5-minute window with an overlap of 80%. The results presented a greater complexity of the EMG signal in the SG group. This group shows higher peaks in Shannon entropy and elevated spectral entropy values compared to the FG group. Channels 2 and 3 presented the largest statistically significant differences.Clinical Relevance— Analyzing diaphragm EMG signals using entropy metrics could improve patient outcomes by optimizing the timing of extubation. These metrics would serve as a key indicator of readiness for extubation, providing an objective basis for more informed clinical decision-making., Research supported in part by the Universidad UNAB, Bucaramanga, Colombia, in part by the CERCA Program/ Generalitat de Catalunya, in part by the Secretaria d’Universitats i Recerca de la Generalitat de Catalunya GRC 2021 SGR 01390, and in part by the Spanish Ministry of Science and Innovation (PID2021-126455OB-I00 MCIN/AEI/FEDER)., Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publication Contribución de congreso (ConferenceOutput)

Measuring high-resolution sleep position in adolescents over 4 nights with smartphone accelerometers

  • Castillo Escario, Yolanda
  • Blanco Almazán, Dolores
  • Ferrer, Lluís
  • Jané Campos, Raimon
© 2023 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting /republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works, Sleep position affects sleep quality and the severity of different diseases. Classical methods to measure sleep position are complex, expensive, and difficult to use outside the laboratory. Wearables and smartphones can help to address these issues to track sleep position at home over several nights. In this study, we monitor high-resolution sleep position in 13 adolescents over 4 nights using smartphone accelerometer data. We aim to investigate the distribution of sleep positions and position changes in adolescents, study their variability across nights, and propose new measures related to nocturnal body movements. We developed a new index, the mean sleep angle change per hour, and calculated three other measures: position shifts per hour, mean time at each position, and periods of immobility. Our results indicate that participants spent 56% of the time on the side (32% right and 24% left), 32% in supine, and 12% in prone position, similar to what happens in adults. However, adolescents moved more than adults during sleep according to all measures. There was some variability between nights, but lower than the inter-subject variability. In conclusion, this work systematically analyzes sleep position over several nights in adolescents, a largely unstudied population, and offers innovative solutions and measures for high-resolution sleep position monitoring in a simple and cost-effective way.Clinical Relevance— Our study characterizes sleep position in adolescents and provides novel unobtrusive methods and quantitative indices to monitor high-resolution sleep position at home during multiple nights., Peer Reviewed, Objectius de Desenvolupament Sostenible::3 - Salut i Benestar, Postprint (author's final draft)