Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 2
Encontrada(s) 1 página(s)

Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Contribución de congreso (ConferenceOutput)

Reduced-Order Model of a Half-Bridge Series Resonant Inverter for Power Control in Domestic Induction Heating Applications

  • Domínguez, A.
  • Barragán, L.A.
  • Artigas, J.I.
  • Otín, A.
  • Urriza, I.
  • Navarro, D.
When modeling resonant inverters considering the harmonic balance method, the order of the obtained transfer functions is twice the state variables number. This is explained because two components are considered for each state variable. In order to obtain a simpler transfer function model of a halfbridge series resonant inverter, different techniques of model order reduction have been considered in this work. Thus, a reduced-order model has been obtained by residualization providing much simpler analytical expressions than the original model. The proposed model has been validated by simulation and experimentally. The validity range of the proposed model is extended up to a tenth of the switching frequency. Taking into account the great load variability of induction heating applications, the proposed reduced-order model will allow the design of advanced controllers such as Gain-Scheduling.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Contribución de congreso (ConferenceOutput)

DC-Gain Measurement of the Frequency-to-Output Power Transfer Function based on sidebands for Domestic Induction Heating Applications

  • Villa, J.
  • Artigas, J.I.
  • Barragan, L.A.
  • Dominguez, A.
  • Otin, A.
  • Urriza, I.
This paper analyzes different alternatives to obtain the dc gain of the frequency-to-output power transfer function of a series half-bridge resonant inverter for domestic induction heating. In this application, a full-wave rectified bus voltage usually feeds the inverter, and a constant switching frequency is applied during each half-period of the mains voltage. This dc gain is the derivative of the output power with respect to the frequency. A finite difference approximation to the derivative can be obtained measuring the output power during two consecutive half-periods of the mains voltage by injecting a small frequency increment in the second one. This paper compares five alternatives to estimate the gain in only one half-period of the mains, what would allow to increase the controller bandwidth. The alternatives are based on the computation of the DTFS of the sidebands. They are off-line implemented and experimentally verified. The proposed method can also be implemented in real time into a digital controller.