CARGADORES DE BATERIAS BIDIRECCIONALES PARA LA INTEGRACION EN MICRORREDES DE VEHICULOS ELECTRICOS Y ESTACIONES DE CARGA ULTRARRAPIDA CON BATERIAS DE RESPALDO

RTI2018-100732-B-C21

•
Funding agency name Agencia Estatal de Investigación
Funding agency acronym AEI
Program Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Call Proyectos I+D+i Retos de Investigación
Call year 2018
State Plan 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Beneficiary centre UNIVERSITAT POLITÈCNICA DE VALÈNCIA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Coordination of different agents in a microgrid using DC-Bus Signaling

  • Patrao Herrero, Iván|||0000-0003-4412-0365
  • Liberos, Marian|||0000-0001-6574-1158
  • Torán, Enric|||0000-0002-0868-9856
  • González-Medina, Raúl|||0000-0003-0378-5045
  • Figueres Amorós, Emilio|||0000-0002-0716-3916
  • Garcerá, Gabriel|||0000-0002-5507-4379
[EN] The DC-Bus Signaling (DBS) is a proven method to coordinate different agents in a microgrid, using the DCvoltage of the microgrid as a communication signal. The droop control applied in a dc-microgrid leads to an error in the voltage regulation of the microgrid, while the power sharing among converters in such microgrid is achieved. By using the voltage at each node of the grid as the DBS signal, the behavior of the different agents in a microgrid can be managed. In this paper the DBS technique is used to coordinate conventional generators, Energy Storage Systems and loads in a microgrid. The control laws proposed are tested in an experimental microgrid., This research was funded by the Spanish Ministerio de Asuntos Económicos y Transformación Digital and the European Regional Development Fund (ERDF) under Grants RTI2018-100732-B-C21 and PID2021-122835OB-C22.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Comparative analysis of B4 and B6 inverter topologies for grid-connected operation

  • Torán, Enric|||0000-0002-0868-9856
  • Liberos, Marian|||0000-0001-6574-1158
  • Patrao Herrero, Iván|||0000-0003-4412-0365
  • González-Medina, Raúl|||0000-0003-0378-5045
  • Garcerá, Gabriel|||0000-0002-5507-4379
  • Figueres Amorós, Emilio|||0000-0002-0716-3916
[EN] This paper analyzes the performance of several topologies of grid-connected inverters. For that purpose, a comparative analysis has been carried out among a classical sixswitch three-phase inverter (B6) and several alternatives of the four-switch three-phase inverter topology (B4). As figures of merit to carry out the comparative study, the efficiency, the total harmonic distortion of the current in the grid, the unbalance of the grid currents and the cost of each alternative have been considered. The performance of the inverters has been evaluated by means of realistic simulations, which have been carried out with PSIMTM software., This research was funded by the Spanish Ministerio de Asuntos Económicos y Transformación Digital and the European Regional Development Fund (ERDF) under Grants RTI2018-100732-B-C21 and PID2021-122835OB-C22.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Suppression of circulating currents in islanded parallel inverters

  • Liberos, Marian|||0000-0001-6574-1158
  • Patrao Herrero, Iván|||0000-0003-4412-0365
  • Torán, Enric|||0000-0002-0868-9856
  • González-Medina, Raúl|||0000-0003-0378-5045
  • Garcerá, Gabriel|||0000-0002-5507-4379
  • Figueres Amorós, Emilio|||0000-0002-0716-3916
[EN] The parallel connection of inverters has some advantages like modularity and redundancy. Nevertheless, the connection in parallel of inverters produces circulating currents that cause adverse effects in the system. In this work, it is presented a control technique for the elimination of the circulating currents. In parallel inverters, the circulating currents agree with the zero-sequence component of the phase currents, so they are suppressed by controlling the zerosequence component of the phase currents of the inverters. Simulation results have been presented considering the connection in parallel of two 5 kW inverters connected in parallel in islanded mode. The results have been obtained by considering linear and non-linear AC loads., This research was funded by the Spanish Ministerio de Asuntos Económicos y Transformación Digital and the European Regional Development Fund (ERDF) under Grants RTI2018-100732-B-C21 and PID2021-122835OB-C22.