Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 4
Encontrada(s) 1 página(s)

UPCommons. Portal del coneixement obert de la UPC
Publication Contribución de congreso (ConferenceOutput)

Large-memory nodes for energy efficient high-performance computing

  • Živanovič, Darko
  • Radulović, Milan
  • Llort, German
  • Zaragoza, David
  • Strassburg, Janko
  • Carpenter, Paul Matthew
  • Radojković, Petar
  • Ayguadé Parra, Eduard|||0000-0002-5146-103X
Energy consumption is by far the most important contributor to HPC cluster operational costs, and it accounts for a significant share of the total cost of ownership. Advanced energy-saving techniques in HPC components have received significant research and development effort, but a simple measure that can dramatically reduce energy consumption is often overlooked. We show that, in capacity computing, where many small to medium-sized jobs have to be solved at the lowest cost, a practical energy-saving approach is to scale-in the application on large-memory nodes. We evaluate scaling-in; i.e. decreasing the number of application processes and compute nodes (servers) to solve a fixed-sized problem, using a set of HPC applications running in a production system. Using standard-memory nodes, we obtain average energy savings of 36%, already a huge figure. We show that the main source of these energy savings is a decrease in the node-hours (node_hours = #nodes x exe_time), which is a consequence of the more efficient use of hardware resources. Scaling-in is limited by the per-node memory capacity. We therefore consider using large-memory nodes to enable a greater degree of scaling-in. We show that the additional energy savings, of up to 52%, mean that in many cases the investment in upgrading the hardware would be recovered in a typical system lifetime of less than five years., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publication Contribución de congreso (ConferenceOutput)

DRAM errors in the field: a statistical approach

  • Živanovič, Darko
  • Esmaili Dokht, Pouya|||0000-0001-8799-5773
  • Moré, Sergi
  • Bartolomé, Javier
  • Carpenter, Paul Matthew
  • Radojković, Petar
  • Ayguadé Parra, Eduard|||0000-0002-5146-103X
This paper summarizes our two-year study of corrected and uncor-rected errors on the MareNostrum 3 supercomputer, covering 2000 billion MB-hours of DRAM in the field. The study analyzes 4.5 million corrected and 71 uncorrected DRAM errors and it compares the reliability of DIMMs from all three major memory manufacturers, built in three different technologies. Our work has two sets of contributions. First, we illustrate the complexity of in-field DRAM error analysis and demonstrate the limitations of various widely-used methods and metrics. For example, we show that average error rates, errors per MB-hour and mean time between failures can provide volatile and unreliable results even after long periods of error logging, leading to incorrect conclusions about DRAM reliability. Second, we present formal statistical methods that overcome many of the limitations of the current approaches. The methods that we present are simple to understand and implement, reliable and widely accepted in the statistical community. Overall, our study alerts the community about the need to, firstly, question the current practice in quantifying DRAM reliability and, secondly, to select a proper analysis approach for future studies. Our strong recommendations are to focus on metrics with a practical value that could be easily related to system reliability, and to select methods that provide stable results, ideally supported with statistical significance., This work was supported by the Collaboration Agreement between Samsung Electronics Co., Ltd. and BSC, Spanish Government through Severo Ochoa programme (SEV-2015-0493), by the Spanish Ministry of Science and Technology through TIN2015-65316-P project and by the Generalitat de Catalunya (contracts 2014-SGR1051 and 2014-SGR-1272). This work has also received funding from the European Union’s Horizon 2020 research and innovation programme under EuroEXA project (grant agreement No 754337). Darko Zivanovic holds the Severo Ochoa grant (SVP-2014-068501) of the Ministry of Economy and Competitiveness of Spain.
Recercat. Dipósit de la Recerca de Catalunya
Publication Contribución de congreso (ConferenceOutput)

DRAM errors in the field: a statistical approach

  • Živanovič, Darko
  • Esmaili Dokht, Pouya
  • Moré, Sergi
  • Bartolomé, Javier
  • Carpenter, Paul Matthew
  • Radojković, Petar
  • Ayguadé Parra, Eduard
This paper summarizes our two-year study of corrected and uncor-rected errors on the MareNostrum 3 supercomputer, covering 2000 billion MB-hours of DRAM in the field. The study analyzes 4.5 million corrected and 71 uncorrected DRAM errors and it compares the reliability of DIMMs from all three major memory manufacturers, built in three different technologies. Our work has two sets of contributions. First, we illustrate the complexity of in-field DRAM error analysis and demonstrate the limitations of various widely-used methods and metrics. For example, we show that average error rates, errors per MB-hour and mean time between failures can provide volatile and unreliable results even after long periods of error logging, leading to incorrect conclusions about DRAM reliability. Second, we present formal statistical methods that overcome many of the limitations of the current approaches. The methods that we present are simple to understand and implement, reliable and widely accepted in the statistical community. Overall, our study alerts the community about the need to, firstly, question the current practice in quantifying DRAM reliability and, secondly, to select a proper analysis approach for future studies. Our strong recommendations are to focus on metrics with a practical value that could be easily related to system reliability, and to select methods that provide stable results, ideally supported with statistical significance., This work was supported by the Collaboration Agreement between Samsung Electronics Co., Ltd. and BSC, Spanish Government through Severo Ochoa programme (SEV-2015-0493), by the Spanish Ministry of Science and Technology through TIN2015-65316-P project and by the Generalitat de Catalunya (contracts 2014-SGR1051 and 2014-SGR-1272). This work has also received funding from the European Union’s Horizon 2020 research and innovation programme under EuroEXA project (grant agreement No 754337). Darko Zivanovic holds the Severo Ochoa grant (SVP-2014-068501) of the Ministry of Economy and Competitiveness of Spain., Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publication Contribución de congreso (ConferenceOutput)

Large-memory nodes for energy efficient high-performance computing

  • Živanovič, Darko
  • Radulović, Milan
  • Llort, German
  • Zaragoza, David
  • Strassburg, Janko
  • Carpenter, Paul Matthew
  • Radojković, Petar
  • Ayguadé Parra, Eduard
Energy consumption is by far the most important contributor to HPC cluster operational costs, and it accounts for a significant share of the total cost of ownership. Advanced energy-saving techniques in HPC components have received significant research and development effort, but a simple measure that can dramatically reduce energy consumption is often overlooked. We show that, in capacity computing, where many small to medium-sized jobs have to be solved at the lowest cost, a practical energy-saving approach is to scale-in the application on large-memory nodes. We evaluate scaling-in; i.e. decreasing the number of application processes and compute nodes (servers) to solve a fixed-sized problem, using a set of HPC applications running in a production system. Using standard-memory nodes, we obtain average energy savings of 36%, already a huge figure. We show that the main source of these energy savings is a decrease in the node-hours (node_hours = #nodes x exe_time), which is a consequence of the more efficient use of hardware resources. Scaling-in is limited by the per-node memory capacity. We therefore consider using large-memory nodes to enable a greater degree of scaling-in. We show that the additional energy savings, of up to 52%, mean that in many cases the investment in upgrading the hardware would be recovered in a typical system lifetime of less than five years., Peer Reviewed, Postprint (published version)