Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 2
Encontrada(s) 1 página(s)

RUA. Repositorio Institucional de la Universidad de Alicante
Publication Otros (Other)

A family of nonseparable scaling functions and compactly supported tight framelets

  • San Antolín Gil, Ángel
  • Zalik, Richard A.
  • San Antolín Gil, Ángel|||/items/b5c4489a-67e8-405f-8357-a7a7bf5fe799
Given integers b and d, with d>1 and |b|>1, we construct even nonseparable compactly supported refinable functions with dilation factor bb that generate multiresolution analyses on L2(Rd). These refinable functions are nonseparable, in the sense that they cannot be expressed as the product of two functions defined on lower dimensions. We use these scaling functions and a slight generalization of a theorem of Lai and Stöckler to construct smooth compactly supported tight framelets. Both the refinable functions and the framelets they generate can be made as smooth as desired. Estimates for the supports of these refinable functions and framelets, are given.
RUA. Repositorio Institucional de la Universidad de Alicante
Publication Otros (Other)

Iterative Methods for the Biomechanical Evaluation of Corneal Response. A Case Study in the Measurement Phase

  • Gómez, Carmelo
  • Piñero, David P.
  • Paredes, Manuel
  • Alió, Jorge L.
  • Cavas Martínez, Francisco
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
The number of corneal surgeries steadily grew in recent years and boosted the development of corneal biomechanical models. These models can contribute to simulating surgery by reducing associated risks and the need for secondary interventions due to ectasias or other problems related to correcting other diseases. Biomechanical models are based on the geometry obtained with corneal topography, which is affected by intraocular pressure and material properties. Knowledge of stress distribution in the measurement phase is a key factor for improving the accuracy of in silico mechanical models. In this work, the results obtained by two different methods: prestress method and displacements method were compared to evaluate the stress and strain distribution in a general geometric model based on the Navarro eye geometry and two real corneal geometries. The results show that both methods are equivalent for the achievement of the stress distribution in the measurement phase. Stress distribution over the corneal geometry in the measurement phase is a key factor for accurate biomechanical simulations, and these simulations could help to develop patient-specific models and reduce the number of secondary interventions in clinical practice.