Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 7
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Otros (Other)

Comparison of Muscle Synergies Between Parkinson’s Disease Patients and Healthy Controls During Walking Over a Mat

  • Akgün, İrem
  • Algaba-Vidoy, Marina
  • Torres-Pardo, Adriana
  • Navarro-López, Víctor
  • Fernández-Vázquez, Diego
  • Carratalá-Tejada, María
  • Molina-Rueda, Francisco
  • Gómez-García, Jorge A.
  • Moreno, Juan C.
  • Demirbüken, İlkşan
  • Barroso, Filipe O.
  • Torricelli, Diego
Proceedings of the 6th International Conference on Neurorehabilitation (ICNR 2024), November 5–8, 2024, La Granja, Spain - Volume 2.-- Editors: Jose L. Pons, Jesus Tornero, Metin Akay., Patients who suffer from Parkinson’s disease (PD) usually present gait dysfunction. The analysis of muscle synergies has been used to unravel neural strategies underlying human locomotion. The main goal of this study was to compare muscle synergies between three PD patients at the early stage of the disease and three healthy controls, when walking on flat terrain and over a mat at self-selected speed. Muscle synergies were extracted from electromyography data of eight lower limb muscles using a non-negative factorization algorithm. Detailed synergy analyses showed differences between groups (in both terrains) in terms of variability accounted for of tibialis anterior and soleus. This study shows the ability of muscle synergies analysis to reveal impaired motor coordination in PD patients and adds more evidence that PD patients present abnormal activation of distal lower limb muscles, even at the early stage of the disease., This work was partially funded by the Spanish ministry of Economics and Digital Transformation within the 2021 MisionesIA call (AI4Healthy Aging, MIA.2021.M02.0007) and partially by the NEUROMARK project (PID2020-120491RA-I00) funded by MCIN/AEI/10.13039/501100011033. This publication is part of The Scientific and Technological Research Council of Turkey (TUBİTAK) 2214-A International Research Fellowship Programme for PhD Students., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Otros (Other)

Arm Swing Kinematic in Subjects with Early Parkinson’s Disease Compared with Healthy Controls When Walking on Unstable Terrain

  • Navarro-López, Víctor
  • Diego-Martínez, Simón García
  • Carratalá-Tejada, María
  • Fernández-Vázquez, Diego
  • Molero-Mateo, Paula
  • Torres-Pardo, Adriana
  • Algaba-Vidoy, Marina
  • Gómez-García, Jorge A.
  • Akgün, Irem
  • Gómez-Suárez, Nicolas
  • Carpio-Chicote, Ainara
  • Trigo, Carlota
  • Torricelli, Diego
  • Molina-Rueda, Francisco
Este trabajo se ha realizado con colaboración internacional, concretamente con investigadores de: Turkey., Reduced arm swing in Parkinson’s disease (PD) is considered a prodromal sign of the disease, being related to gait disturbances and an increased risk of falls. The aim of this study was to compare the arm swing kinematics of people with early PD and healthy people walking on flat ground and over a mat at self-selected speed. Methods: A cross-sectional study was carried out. Gait analysis was performed using an inertial sensor system (IMUs) in an 11 m corridor. Results: The study included 12 PD patients (H&Y score between I and III) and 4 healthy controls. Controls and PD patients showed no significant differences in gait speed, however, shoulder (p = 0.003) and elbow (p = 0.031) arm swing in the sagittal plane during gait decreased significantly on the less affected side of PD patients when walking on a mat compared to flat ground., This work was partially funded by the Spanish ministry of Economics and Digital Transformation within the 2021 MisionesIA call (AI4Healthy Aging, MIA.2021.M02.0007) and partially by the NEUROMARK project (PID2020-120491RA-I00) funded by MCIN/AEI/10.13039/501100011033., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Otros (Other)

An Algorithm for Gait Segmentation Using Surface Electromyography and Subsequence Dynamic Time Warping

  • Algaba-Vidoy, Marina
  • Laudanski, Annemarie F.
  • Barroso, Filipe O.
  • Gómez-García, Jorge A.
  • Torricelli, Diego
  • Moreno, Juan Camilo
Proceedings of the 6th International Conference on Neurorehabilitation (ICNR 2024), November 5–8, 2024, La Granja, Spain - Volume 2.-- Editors: Jose L. Pons, Jesus Tornero, Metin Akay., Gait segmentation in surface electromyography (sEMG) studies is usually achieved through kinematics. However, there are occasions when this multimodal analysis cannot be implemented. This study presents an algorithm for automated gait segmentation using sEMG signals based on subsequence Dynamic Time Warping (sDTW). Stride templates were chosen from vastus lateralis (VL) muscle and applied to segment the sEMG signals from six healthy subjects walking at various speeds. Heel strike events were detected with high temporal precision (<70 ms) and high fidelity (F1-score > 0.9) across all velocities. This approach therefore shows promise for specific experimental conditions, particularly when multimodal gait analysis is impractical. Future work will focus on the validation of this method in elderly and pathological populations to further assess its robustness., This work was partially funded by the Spanish ministry of Economics and Digital Transformation within the 2021 MisionesIA call (AI4HealthyAging, MIA.2021.M02.0007) and by the NEUROMARK project (PID2020-120491RA-I00; MCIN/AEI/10.13039/501100011033)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Otros (Other)

Applicability of Gait Indices in Parkinson’s Disease: A Review on Clinical, Methodological and Experimental Challenges

  • Gómez-Suárez, Nicolás
  • Gómez-García, Jorge A.
  • Serrano Olmedo, José Javier
  • Moreno, Juan Camilo
  • Torricelli, Diego
Proceedings of the 6th International Conference on Neurorehabilitation (ICNR 2024), November 5–8, 2024, La Granja, Spain - Volume 2.-- Editors: Jose L. Pons, Jesus Tornero, Metin Akay., This paper reviews the use of various gait indices for assessing Parkinson’s disease gait. Selected indices include the Gait Deviation Index, the Gillette Gait Index, the Gait Profile Score, the Hip Flexor Index, the GDI-Kinetic, the Symmetry Index, and the Gait Variability Index. These indices offer insights into gait deviations and variability crucial for clinical evaluation and research. However, their application in PD faces challenges due to the need for high-quality data and specific normative datasets. Further research is needed to validate these indices with PD-specific data to improve diagnostic accuracy and treatment outcomes., This work is partially funded by the Spanish ministry of Economics and Digital transformation within the 2021 MisionesIA call (AI4HealthyAging, MIA.2021.M02.0007) and by the NEUROMARK project (PID2020-120491RA-I00) funded by MCIN/AEI/10.13039/501100011033., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Otros (Other)

Arm Swing Kinematic in Subjects with Early Parkinson’s Disease Compared with Healthy Controls When Walking on Unstable Terrain

  • Navarro López, Víctor
  • García Diego-Martínez, Simón
  • Carratalá-Tejada, M.
  • Fernández-Vázquez, Diego
  • Molero-Mateo, Paula
  • Torres-Pardo, Adriana
  • Algaba-Vidoy, Marina
  • Gómez-García, Jorge A.
  • Akgün, Irem
  • Gómez-Suárez, Nicolás
  • Carpio-Chicote, Ainara
  • Trigo, Carlota
  • Torricelli, Diego
  • Molina Rueda, Francisco
Proceedings of the 6th International Conference on Neurorehabilitation (ICNR 2024), November 5–8, 2024, La Granja, Spain - Volume 2.-- Editors: Jose L. Pons, Jesus Tornero, Metin Akay., Reduced arm swing in Parkinson’s disease (PD) is considered a prodromal sign of the disease, being related to gait disturbances and an increased risk of falls. The aim of this study was to compare the arm swing kinematics of people with early PD and healthy people walking on flat ground and over a mat at self-selected speed. Methods: A cross-sectional study was carried out. Gait analysis was performed using an inertial sensor system (IMUs) in an 11 m corridor. Results: The study included 12 PD patients (H&Y score between I and III) and 4 healthy controls. Controls and PD patients showed no significant differences in gait speed, however, shoulder (p = 0.003) and elbow (p = 0.031) arm swing in the sagittal plane during gait decreased significantly on the less affected side of PD patients when walking on a mat compared to flat ground., This work was partially funded by the Spanish ministry of Economics and Digital Transformation within the 2021 MisionesIA call (AI4Healthy Aging, MIA.2021.M02.0007) and partially by the NEUROMARK project (PID2020-120491RA-I00) funded by MCIN/AEI/10.13039/501100011033., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Otros (Other)

Is IMU-Based Center of Mass Estimation Reliable? Preliminary Study in Perturbed Conditions

  • Torres-Pardo, Adriana
  • Trigo, Carlota
  • Gómez-García, Jorge A.
  • Moreno, Juan Camilo
  • Carey, Stephanie L.
  • Torricelli, Diego
Proceedings of the 6th International Conference on Neurorehabilitation (ICNR 2024), November 5–8, 2024, La Granja, Spain - Volume 2.-- Editors: Jose L. Pons, Jesus Tornero, Metin Akay., Falls, often occurring during walking, are a major health concern. Clinical stability evaluations are typically subjective and lack standardized methods. There is a need for objective, easy-to-implement, and standardized methods to evaluate stability in clinical settings. Inertial measurement units (IMUs) offer a potential solution, but their accuracy needs validation in this context. We performed an exploratory analysis of a commercial (Xsens MVN, Movella, Netherlands) IMU-based center of mass (CoM) estimation, often needed in stability analysis, under various perturbations induced by the split-belt treadmill of the CAREN system from Motek. Results suggest that, although IMUs trajectory estimates are more accurate than velocity and acceleration, all estimates still present important deviations from those obtained by optoelectronic systems., This publication has been supported by the grant with reference PIPF-2022/SAL-GL-25242 funded by the Regional Government of Madrid in the framework of the “Predoctoral Research Training Program 2022”. This publication is part of the project NEUROMARK (PID2020-120491RA-I00) funded by MCIN/AEI/ 10.13039/501100011033. This publication is part of the project AI4HealthyAging (MIA.2021.M02.0007) funded by “Ministerio de Economía y Transformación Digital” and “European Union NextGenerationEU/PRTR”., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Otros (Other)

Gait Analysis of Electromyographic Spectral Differences in Stroke Survivors and Healthy Controls

  • Algaba-Vidoy, M.
  • Gómez-García, J. A.
  • Barroso, F. Oliveira
  • Molina-Rueda, F.
  • Torricelli, D.
  • Moreno, J. C.
Advances in Digital Health and Medical Bioengineering: Proceedings of the 11th International Conference on E-Health and Bioengineering, EHB-2023, November 9–10, 2023, Bucharest, Romania – Volume 2: Health Technology Assessment, Biomedical Signal Processing, Medicine and Informatics. Conference proceedings., Comunicación de congreso publicada en Advances in Digital Health and Medical Bioengineering, Surface electromyography (sEMG) is a commonly used technique to evaluate neuromotor disorders. The study of spectral components of sEMG signals can provide insights into the behavior of muscles. This study assessed the activity of the tibialis anterior (TA) muscle during gait of individuals affected by stroke and healthy controls. Spectral methods were used to study distinctive features of stroke gait, to differentiate the paretic side of stroke patients from their nonparetic side and to compare it to healthy reference. Spectrograms of sEMG signals were used as a visual tool to intuitively display power output along gait phases. These observations were then verified with the computation of mean frequency (MNF) and median frequency (MDF) from the power spectral density (PSD). Results indicated that MNF and MDF were significantly reduced in paretic and nonparetic limbs compared to healthy controls (p < 0.001). A decrease in MNF and MDF was also observed in paretic vs. nonparetic in stance (pMNF = 0.018) and swing (pMNF < 0.001, pMDF < 0.015) phases. In general, a decrease in the activation power of high frequencies of TA muscle was observed, suggesting the presence of foot drop. Spectral differences between affected and unaffected sides of stroke patients were analyzed, which may be expanded in future studies using other time-frequency domain techniques, such as wavelets. This work demonstrated the viability of frequency domain approaches to characterize gait asymmetries in stroke. In consequence, this method may complement traditional clinical evaluation of the severity and evolution of patients when subjected to intervention and/or rehabilitation strategies., This work is partially funded by the Spanish ministry of Economics and Digital transformation within the 2021 MisionesIA call (AI4HealthyAging, MIA.2021.M02.0007) and by the NEUROMARK project (PID2020-120491RA-I00) funded by MCIN/AEI/, Peer reviewed