Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 10
Encontrada(s) 1 página(s)

RUA. Repositorio Institucional de la Universidad de Alicante
Publication Otros (Other)

Multi-element determination in edible oils by inductively coupled plasma optical emission spectrometry using magnetic eutectic mixture-based ultrasound-assisted dispersive liquid-liquid microextraction

  • Nario, Nicolás A.
  • Aguirre Pastor, Miguel Ángel
  • Grünhut, Marcos
  • Vidal, Lorena
  • Domini, Claudia E.
  • Canals, Antonio
  • Aguirre Pastor, Miguel Ángel|||/items/2ded3973-b197-4677-af9e-89db8c79363f
  • Vidal, Lorena|||/items/87ae49dd-73c8-41be-9c0c-2d3c37772793
  • Canals, Antonio|||/items/4a7548bb-9862-4dd9-bee4-559e2a77eb23
An ultrasound-assisted dispersive liquid-liquid microextraction method using a magnetic eutectic mixture has been developed for the multi-elemental determination of Al, Ba, Cd, Cr, Cu, Mn, Mo, Ni, Pb, Ti, V, and Zn in edible oils by inductively coupled plasma optical emission spectrometry. A two-step multivariate approach was applied for extraction condition optimization, including a full factorial design and a central composite design. The optimized extraction conditions were: diluted sample weight (10.0 g), extractant volume (268 μL), extraction temperature (60 °C), and extraction time (1 min). Under optimized experimental conditions, all analytes showed good linearity (R2 ≥ 0.995), with detection and quantification limits of 0.10–1.6 and 0.3–5.0 μg kg−1, respectively. Recovery values ranged from 85 to 110%. This simple, fast, and cost-effective method aligns with Green Analytical Chemistry principles. An AGREE score of 0.63 confirms its eco-friendly nature and competitive performance against existing alternatives.
RUA. Repositorio Institucional de la Universidad de Alicante
Publication Otros (Other)

Co-based magnetic eutectic mixture for the extraction of trace metals in essential oils used in cosmetic industry prior to analysis by inductively coupled plasma optical emission spectrometry

  • Abellán-Martín, Sergio J.
  • Kaynarova, Lidia
  • Georgieva, Deyana
  • Simitchiev, Kiril
  • Aguirre Pastor, Miguel Ángel
  • Vidal, Lorena
  • Canals, Antonio
  • Aguirre Pastor, Miguel Ángel|||/items/2ded3973-b197-4677-af9e-89db8c79363f
  • Vidal, Lorena|||/items/87ae49dd-73c8-41be-9c0c-2d3c37772793
  • Canals, Antonio|||/items/4a7548bb-9862-4dd9-bee4-559e2a77eb23
Background: Cosmetic products are widely used today and are often associated with a healthy lifestyle. However, their widespread application and the presence of potentially toxic substances have raised increasing concerns regarding their impact on human health. Among these substances, metals are particularly hazardous due to their ability to penetrate the skin and cause adverse health effects, even at very low concentrations. Therefore, the development of novel and reliable methodologies for the determination of trace metals in cosmetics is of great importance for ensuring product safety. Results: A new analytical method based on a magnetic eutectic mixture (MEM) ultrasound-assisted emulsification-micro-extraction (USAEME) followed by inductively coupled plasma optical emission spectrometry (ICP OES) for trace metals in cosmetics has been developed. The extraction procedure was optimized using a multivariate approach. The method was evaluated under optimized extraction conditions (i.e., sample mass, 11 g; MEM volume, 59 μL; extraction time, 3 min and ultrasound as dispersive mode). Limits of detection from 0.05 to 5.4 μg kg-1 were obtained, and the repeatability was evaluated at two different levels (i.e., 75 and 300 μg kg-1), resulting in relative standard deviations below 5 % (n = 5). Enhanced sensitivity was achieved, with enrichment factors ranging from 15 to 67 compared to direct ICP OES analysis. The method applicability was assessed through recovery studies using two real essential oil samples (i.e., Pelargonium graveolens and lavender) used in cosmetic manufacture. The recovery values obtained ranged between 94 and 116% for all the elements. Significance: A novel, rapid, sensitive, and environmentally sustainable method was developed for the simultaneous determination of Al, Cd, Cr, Cu, Mn, Pb, and Zn in essential oil samples using ICP OES. The methodology incorporated a preconcentration step via USAEME employing a new designed Co-based MEM (i.e., cobalt (II) chloride hexahydrated:ethylene glycol, 1:2).
RUA. Repositorio Institucional de la Universidad de Alicante
Publication Otros (Other)

Electrochemically controlled liquid-liquid microextraction: an innovative methodology for heavy metal extraction from tea using non-toxic menthol-based eutectic mixture

  • Marco, Andrea
  • Aguirre Pastor, Miguel Ángel
  • Quijada Tomás, César
  • Hidalgo, Montserrat
  • Marco, Andrea|||/items/ed30abdd-8076-4a93-a527-2b2d5366f59f
  • Aguirre Pastor, Miguel Ángel|||/items/2ded3973-b197-4677-af9e-89db8c79363f
  • Hidalgo, Montserrat|||/items/8c122b2d-4d92-45f3-ad75-e863e4e18750
Background: A growing concern about toxic metal contamination in food has generated a need for efficient, sustainable, and non-toxic sample preparation techniques. Conventional extraction methodologies frequently entail the utilization of hazardous solvents or exhibit a lack of sensitivity. There is an increasing demand for analytical methodologies that are more environmentally friendly and capable of extracting trace metals from complex matrices, such as tea. This study aims to address the need for an efficient and environmentally friendly method for the extraction of metals from tea samples using a combination of electrochemically assisted microextraction and a eutectic mixture as extractant. Results: An innovative electrochemically enhanced liquid-liquid microextraction technique has been developed, employing a green eutectic mixture composed of a menthol-based hydrophobic deep eutectic solvent (menthol:decanoic acid, 2:1) and a non-toxic ionic liquid (1-hexyl-3-methylimidazolium chloride) to enhance conductivity. The experimental conditions for the extraction procedure were optimized through the implementation of a design of experiments approach. In the context of optimal conditions (i.e., 10 g sample, 315 μL extractant, 5 min extraction, pH 4.66, 1 wt% 8-hydroxyquinoline, 600 rpm shaking and a single −0.75 V pulse vs. Ag), the method demonstrated excellent linearity, repeatability, and low limits of detection: 0.2, 0.2, 0.7, 2.8 and 0.5 μg kg−1 for Cd, Cr, Ni, Pb and Zn, respectively. The recovery of real and certified tea samples approached 100 %, with negligible matrix effects. Furthermore, no analytes exceeded the maximum permissible limits established by legislation in the infused samples under study. Significance: The proposed method represents a substantial advance in sustainable analytical chemistry, as it facilitates the efficient extraction of metals from tea without the use of toxic solvents. Its performance and environmental compatibility position it as a solid alternative for routine metal analysis in food safety monitoring.
RUA. Repositorio Institucional de la Universidad de Alicante
Publication Otros (Other)

Stimulus-responsive smart solvents and their application in analytical liquid-liquid (micro)extraction techniques

  • Aguirre Pastor, Miguel Ángel
  • Vidal, Lorena
  • Ahmadi, Mazaher
  • Canals, Antonio
  • Aguirre Pastor, Miguel Ángel|||/items/2ded3973-b197-4677-af9e-89db8c79363f
  • Canals, Antonio|||/items/4a7548bb-9862-4dd9-bee4-559e2a77eb23
  • Vidal, Lorena|||/items/87ae49dd-73c8-41be-9c0c-2d3c37772793
Switchable-hydrophilicity solvents are a new type of solvents that could be very promising for liquid-liquid (micro)extraction. Nevertheless, they have been scarcely used in this critical step of chemical analysis. This article presents a comprehensive and critical review of fundamentals, chemical factors and stimulus, that reversibly modify the polarity of these solvents. This unique characteristic allows the reversible transition of the solvent from a hydrophobic to a hydrophilic state, favoring liquid-liquid (micro)extraction. Special attention is paid to new types of stimuli as light and voltage to extend the applicability of these exciting solvents in liquid-liquid (micro)extraction.
RUA. Repositorio Institucional de la Universidad de Alicante
Publication Otros (Other)

Synergistic combination of natural deep eutectic solvent and chemical vapor generation for trace determination of As, Cd, Hg and Pb in drug samples by inductively coupled plasma optical emission spectrometry

  • Abellán-Martín, Sergio J.
  • Pérez, Jorge
  • Pinheiro, Fernanda C.
  • Nóbrega, Joaquim A.
  • Aguirre Pastor, Miguel Ángel
  • Vidal, Lorena
  • Canals, Antonio
  • Aguirre Pastor, Miguel Ángel|||/items/2ded3973-b197-4677-af9e-89db8c79363f
  • Canals, Antonio|||/items/4a7548bb-9862-4dd9-bee4-559e2a77eb23
  • Vidal, Lorena|||/items/87ae49dd-73c8-41be-9c0c-2d3c37772793
  • Pérez, Jorge|||/items/e306700e-e606-4a9e-844f-b45528fa9b23
A new and environmentally friendly analytical method for simultaneous determination of As, Cd, Hg and Pb in drug samples by inductively coupled plasma optical emission spectrometry (ICP OES) has been developed. In order to increase the sensitivity of the analysis, a multinebulizer has been used for chemical vapor generation (CVG) after a dispersive liquid-liquid microextraction (DLLME) procedure using a natural deep eutectic solvent (NADES) as extractant solvent. The factors affecting analyte extraction and on-line chemical vapor generation have been optimized by multivariate analysis. Under optimized conditions, DLLME-CVG-ICP OES improved limit of quantitation (LOQ) values on average 50-fold higher compared with direct ICP OES analysis and afforded an increase of the sensitivity (i.e., enrichment factor) on average 25-times higher than those obtained with CVG-ICP OES analysis. According to the United States Pharmacopoeia (USP) Chapter 232, it means LOQ values are on average 4.3-times lower than their respective 0.3J values for the target-elements from class 1. Trueness has been evaluated by recovery experiments following USP recommendations for two oral drug samples in solid dosage form (i.e., commercial dosage tablets). In addition, the greenness of the developed method has been evaluated using the AGREEprep metrics, showing an excellent green character since it includes the miniaturization of the sample preparation procedure using a reduced volume (i.e., few microliters) of a non-hazardous extractant solvent for multielemental analysis.
RUA. Repositorio Institucional de la Universidad de Alicante
Publication Otros (Other)

Tunable Properties of Non-Volatile Magnetic Mixtures on Different Surfaces

  • Abellán-Martín, Sergio J.
  • Zapater, Cristina
  • González-Gallardo, Nerea
  • Aguirre Pastor, Miguel Ángel
  • Vidal, Lorena
  • Ramón, Diego J.
  • Canals, Antonio
  • Aguirre Pastor, Miguel Ángel|||/items/2ded3973-b197-4677-af9e-89db8c79363f
  • Canals, Antonio|||/items/4a7548bb-9862-4dd9-bee4-559e2a77eb23
  • Ramón, Diego J.|||/items/cede7c2c-35fe-43e3-8148-905611ae6646
  • Vidal, Lorena|||/items/87ae49dd-73c8-41be-9c0c-2d3c37772793
  • Zapater, Cristina|||/items/167e0084-0fbb-4747-9758-ade350b2e3e2
  • González-Gallardo, Nerea|||/items/cb9393bb-82cb-4197-b0eb-b0839aa18ee5
In this work, the surface nature-dependent behaviors of magnetic deep eutectic solvents (MDES) and magnetic low-transition-temperature mixtures (MLTTM) are reported for the first time. It has been observed that the surface of material where the MDES or the MLTTM is placed could considerably affect the dispersion and the magnetic and structural properties of these magnetic mixtures. Several experiments have been carried out in order to point out the differences observed in the properties depending on the material on which these magnetic mixtures are placed. As a result, it has been shown that the MDESs or MLTTMs are retained and adhered to glass surfaces, resulting in a loss of magnetism in addition to a loss in the performance of synthesis carried out on the closeness of glass materials as the interaction between the glass and the mixture modify the composition and therefore the properties. As a preliminary result, when using these magnetic mixtures as extractant solvents in dispersive liquid-liquid microextraction, the MDES or MLTTM is retained on the walls of the glass tubes reducing the extraction efficiency, repeatability and the extraction recovery using an external magnetic field. For all these reasons, polypropylene materials should be recommended when handling MDES and MLTTMs.
RUA. Repositorio Institucional de la Universidad de Alicante
Publication Otros (Other)

Recent green approaches in liquid-phase microextraction

  • Aguirre Pastor, Miguel Ángel
  • Arroyo-Manzanares, Natalia
  • Carbonell-Rozas, Laura
  • Grau, José
  • Moreno, Carlos
  • Vidal, Lorena
  • Aguirre Pastor, Miguel Ángel|||/items/2ded3973-b197-4677-af9e-89db8c79363f
  • Vidal, Lorena|||/items/87ae49dd-73c8-41be-9c0c-2d3c37772793
The miniaturization of conventional extraction techniques, particularly microextraction methods, has led to a reduction in the use of hazardous reagents and waste. However, the continued use of toxic solvents and materials, along with time-consuming sample preparation processes, negatively impacts the overall sustainability of these methods. As a result, there is growing interest in exploring greener alternatives. This review highlights the most promising green solvents for liquid-phase microextraction, including (natural) deep eutectic solvents, low-toxicity ionic liquids, surfactants, micellar solvents, and bio-based solvents, emphasizing their applications in innovative sample preparation techniques in the last five years. Particular emphasis is placed on their use in automated and semi-automated systems, in line with the increasing role of automation in Analytical Chemistry. Selected applications have been carefully reviewed and discussed to illustrate key advances in the use of green solvents and automation for extracting a wide range of compounds from various matrices. In addition, future perspectives are outlined to guide further development of liquid-phase microextraction in alignment with current trends in green sample preparation.
RUA. Repositorio Institucional de la Universidad de Alicante
Publication Otros (Other)

Sensitive elemental analysis of edible oil samples using a hydrophilic eutectic mixture as green solvent in electrochemically controlled liquid-liquid microextraction

  • Marco, Andrea
  • Pertusa, Borja
  • Aguirre Pastor, Miguel Ángel
  • Quijada Tomás, César
  • Hidalgo, Montserrat
  • Marco, Andrea|||/items/ed30abdd-8076-4a93-a527-2b2d5366f59f
  • Aguirre Pastor, Miguel Ángel|||/items/2ded3973-b197-4677-af9e-89db8c79363f
  • Hidalgo, Montserrat|||/items/8c122b2d-4d92-45f3-ad75-e863e4e18750
Background: Analyzing toxic metals in edible oils is crucial due to the associated health risks and strict regulatory limits. Traditional extraction methods are often time-consuming and require toxic solvents. Additionally, they are sometimes ineffective in complex oil matrices. Therefore, there is a strong demand for sustainable, efficient methodologies for extracting trace metals from oils. This study presents a green, effective approach to metal extraction from various edible oils using electrochemically enhanced microextraction. Results: We present a new, environmentally friendly, electrochemically enhanced liquid-liquid microextraction (EC-LLME) method that uses a choline chloride-based deep eutectic solvent (CC:EG, 1:2) to extract Cd, Cu, Fe, Ni, and Pb from various oil samples. We optimized the extraction parameters using a two-step experimental design. Under the optimal conditions of a 15 g sample, 315 μL of extractant, a 10 min extraction time, and a -0.75 V vs Ag pulse, the method achieved excellent linearity in the range of 5–500 μg kg-1, high repeatability (CV ≤ 6%), and low detection limits: 0.16 μg·kg-1 (Cd and Fe), 0.09 μg·kg-1 (Cu), 0.4 μg·kg-1 (Ni), and 1.5 μg·kg-1 (Pb). No analyte exceeded legal limits in the three samples studied (i.e., refined rapeseed oil, refined sunflower oil, and virgin olive oil), and recoveries in real and certified samples were nearly 100%, confirming minimal matrix effects. Significance: The EC-LLME method is a novel, sustainable alternative for extracting and quantifying trace metals in edible oils. Its superb analytical capabilities and eco-friendly safety, achieved by steering clear of noxious solvents, make it a suitable option for the identification of trace metals in edible vegetable oil samples.
RUA. Repositorio Institucional de la Universidad de Alicante
Publication Otros (Other)

Ethylene glycol-based dispersive liquid-liquid microextraction of bisphenols in edible oil samples

  • Zapater, Cristina
  • Vidal, Lorena
  • Aguirre Pastor, Miguel Ángel
  • Canals, Antonio
  • Zapater, Cristina|||/items/167e0084-0fbb-4747-9758-ade350b2e3e2
  • Vidal, Lorena|||/items/87ae49dd-73c8-41be-9c0c-2d3c37772793
  • Aguirre Pastor, Miguel Ángel|||/items/2ded3973-b197-4677-af9e-89db8c79363f
  • Canals, Antonio|||/items/4a7548bb-9862-4dd9-bee4-559e2a77eb23
This study compares, for the firt time, the use of three different ethylene glycol-based extractant solvents in dispersive liquid-liquid microextraction (DLLME) for the determination of four bisphenols (i.e., BPF, BPA, BPAP, and BPAF) in edible oils by liquid chromatography-diode array detector (LC-DAD). The extractants studied were: pure ethylene glycol (EG), a deep eutectic solvent or DES (i.e., chlorine chloride (ChCl) and EG, 1:2 M ratio), and a magnetic deep eutectic solvent or MDES (i.e., ChCl, EG and iron chloride hexahydrate (FeCl3·6H2O), 1:4:1 M ratio). Two-step multivariate optimization was performed for EG and DES, while one-step optimization was applied for MDES. The optimal conditions for EG and DES were similar with 50 μL of extractant volume and 1 min of extraction time, except for centrifugation conditions which were 3 min and 370 g-force and 3 min and 832 g-force for EG and DES, respectively. The use of MDES required a higher volume of extractant (i.e., 75 μL) and a longer extraction time (i.e., 4.5 min). The most satisfactory results were achieved using EG, exhibiting adequate linearity (r ≥ 0.990), lower limits of detection (LODs) (i.e., 0.3 μg kg−1), excellent repeatability (RSD ≤3.2 %) for all analytes and non-significant matrix effects in real edible oil samples (i.e., relative recovery values: 71–121 %). Therefore, pure ethylene glycol is the most suitable extractant when compared to ethylene glycol-based eutectic mixtures and their magnetic variant. This finding underscores the necessity for further exploration of the pure constituents of mixtures as potential extractants.
RUA. Repositorio Institucional de la Universidad de Alicante
Publication Otros (Other)

A natural deep eutectic solvent-based liquid-liquid microextraction for the determination of bisphenols in mineral and river water samples

  • Rubio, Iván
  • Rayos, Javier
  • Ortega, Irene
  • Aguirre Pastor, Miguel Ángel
  • Vidal, Lorena
  • Canals, Antonio
  • Canals, Antonio|||/items/4a7548bb-9862-4dd9-bee4-559e2a77eb23
  • Vidal, Lorena|||/items/87ae49dd-73c8-41be-9c0c-2d3c37772793
  • Aguirre Pastor, Miguel Ángel|||/items/2ded3973-b197-4677-af9e-89db8c79363f
  • Rubio, Iván|||/items/772cfa96-2abc-46bb-a27a-eefd47ad6c5d
This study aims to develop a novel method for the determination of five bisphenols (specifically BPS, BPA, BPAP, BPAF, and BPF) in aqueous samples using a natural deep eutectic solvent (NADES) as extractant phase. The environmentally friendly extractant decanoic acid:DL-menthol (1:2 molar ratio) has been employed for the extraction and preconcentration of BPs using dispersive liquid-liquid microextraction prior to liquid chromatography coupled with a diode array detector. The methodology has been evaluated under optimized extraction conditions, namely NADES volume (50 μL), sample pH (7), extraction time (3 min), centrifugation speed (370 g-force) and centrifugation time (1 min), resulting in good linearity with correlation coefficients between 0.993 and 0.999. The relative standard deviation was found to range from 4 to 19 %, while the detection limits were established between 1.5 and 3.3 μg/L. In the course of evaluating the recovery on different water samples, including mineral water, river water, and water from an organization engaged in the direct supply of packaged drinking water to end consumers, the relative recovery values ranged between 70 and 119 %. Additionally, a migration study was conducted utilizing polycarbonate bottles. Finally, an evaluation of the method environmental impact was performed with AGREEprep metric, providing the highest value compared to previous methodologies for the same purpose.