Skip to main content

RED NACIONAL PARA LA INNOVACION EN LAS TECNICAS DE TRATAMIENTO DE MUESTRAS MINIATURIZADAS

RED2018-102522-T

•
Funding agency name Agencia Estatal de Investigación
Funding agency acronym AEI
Program Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Call Redes Investigación /Redes Excelencia
Call year 2018
State Plan 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Beneficiary centre UNIVERSIDAD DE CORDOBA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 8
Encontrada(s) 1 página(s)

RUA. Repositorio Institucional de la Universidad de Alicante
Publication Otros (Other)

Vitamin E determination in edible oils by reversed-phase dispersive liquid-liquid microextraction and screen-printed carbon electrodes

  • Diuzheva, Alina
  • Fernández Martínez, Elena
  • Vidal, Lorena
  • Andruch, Vasil
  • Canals, Antonio
  • Canals, Antonio|||/items/4a7548bb-9862-4dd9-bee4-559e2a77eb23
  • Vidal, Lorena|||/items/87ae49dd-73c8-41be-9c0c-2d3c37772793
A novel simple, environmentally friendly and portable method to determine vitamin E in edible oils based on reversed-phase dispersive liquid-liquid microextraction combined with electrochemical detection using screen-printed carbon electrodes (SPCEs) has been developed. Vitamin E was extracted from oil samples into a 4 M HCl aqueous solution and determined by differential pulse voltammetry using SPCEs. The extraction conditions optimized by experimental design (i.e., Plackett-Burman and central composite designs) were: aqueous 4 M HCl extractant volume, 43 µL; extraction time, 2 min; centrifugation time, 10 min; and centrifugation speed, 3000 rpm. The proposed method requires a standard addition calibration approach, and the working range showed good linearity from 0 to 20 mg L−1, with a correlation coefficient ranging from 0.990 to 0.995 (N=5). The methodological limit of detection was between 1 and 3 mg L−1. The repeatability of the proposed method was evaluated at 15 mg L−1, and the relative standard deviation ranged between 10 and 15% (n=5). For the quantification of vitamin E in ten commercial samples of olive, sesame, soybean, sunflower and a mixture of sunflower and corn oils, the volume of the extractant phase (i.e., 4 M HCl aqueous solution) was increased up to 100 µL and satisfactory recoveries were obtained in the range of 85-115%, confirming the applicability of the method.
RUA. Repositorio Institucional de la Universidad de Alicante
Publication Otros (Other)

Electrochemical Sensor for the Determination of Methylthiouracil in Meat Samples

  • Marco, Andrea
  • Canals, Antonio
  • Morallon, Emilia
  • Aguirre Pastor, Miguel Ángel
  • Aguirre Pastor, Miguel Ángel|||/items/2ded3973-b197-4677-af9e-89db8c79363f
  • Canals, Antonio|||/items/4a7548bb-9862-4dd9-bee4-559e2a77eb23
  • Marco, Andrea|||/items/ed30abdd-8076-4a93-a527-2b2d5366f59f
  • Morallon, Emilia|||/items/a15cf511-9365-4c40-afcb-ea29d4418244
Two analytical methods based on miniaturized electrochemical sensors, voltammetric and amperometric sensors, have been developed for the determination of 6-methyl-2-thiouracil (MTU) in meat consumption samples (beef liver and foie). A multivariate approach has been considered to optimize the experimental procedure including extraction and electrochemical detection. Under optimal conditions and at a typical working potential of 1.55 V (vs Ag pseudo-reference electrode), response is linear in the range 0 to 20 µg L−1 MTU concentration range. The empirical limit of detection is 0.13 µg L−1, lower than the maximum concentration established by legislation. The electrochemical methods have been used to analyze MTU-spiked meat samples, and recovery values varying between 85 and 95% with coefficients of variation <30%. The analytical methods developed with the miniaturized electrochemical sensors can successfully determine the concentration of MTU in real meat samples with high accuracy, being the results obtained similar to those provided by other methods such as UV-Vis spectrophotometry. Finally, the degree of sustainability of the electrochemical sensors-based developed method has been quantified by means of the Analytical Eco-Scale.
RUA. Repositorio Institucional de la Universidad de Alicante
Publication Otros (Other)

Dispersive liquid–liquid microextraction of Cd, Hg and Pb from medicines prior to ICP OES determination according to the United States Pharmacopeia

  • Pinheiro, Fernanda C.
  • Aguirre Pastor, Miguel Ángel
  • Nóbrega, Joaquim A.
  • Canals, Antonio
  • Aguirre Pastor, Miguel Ángel|||/items/2ded3973-b197-4677-af9e-89db8c79363f
  • Canals, Antonio|||/items/4a7548bb-9862-4dd9-bee4-559e2a77eb23
A simple, sensitive and matrix-effect free analytical method for simultaneous determination of Cd, Hg and Pb in drug samples (i.e., commercial dosage tablets) by inductively coupled plasma optical emission spectrometry (ICP OES) has been developed. According to the United States Pharmacopeia (USP) Chapter 232, those metals are considered elemental impurities from class 1 and they must be assessed in pharmaceutical production as well as in quality control evaluation. In order to increase the sensitivity of the analysis, dispersive liquid–liquid microextraction (DLLME) was performed and seven factors affecting analyte extraction were optimized by multivariate analysis. A microvolume of analyte enriched phase was directly introduced into the plasma using a multi-nebulizer, providing a high enrichment factor. When compared to conventional ICP OES analysis, DLLME improves the limit of quantitation (LOQ) values on average 40-fold for all analytes. Consequently, LOQ values were significantly lower than their permissible daily exposure limits for oral drugs. Accuracy was evaluated by addition and recovery experiments following USP recommendations in eight commercial drug samples. Recovery and RSD values were within the range of 90–108% and 1–9%, respectively.
RUA. Repositorio Institucional de la Universidad de Alicante
Publication Otros (Other)

Dispersive liquid-liquid microextraction based on deep eutectic solvent for elemental impurities determination in oral and parenteral drugs by inductively coupled plasma optical emission spectrometry

  • Pinheiro, Fernanda C.
  • Aguirre Pastor, Miguel Ángel
  • Nóbrega, Joaquim A.
  • González-Gallardo, Nerea
  • Ramón, Diego J.
  • Canals, Antonio
  • Aguirre Pastor, Miguel Ángel|||/items/2ded3973-b197-4677-af9e-89db8c79363f
  • Canals, Antonio|||/items/4a7548bb-9862-4dd9-bee4-559e2a77eb23
  • Ramón, Diego J.|||/items/cede7c2c-35fe-43e3-8148-905611ae6646
  • González-Gallardo, Nerea|||/items/cb9393bb-82cb-4197-b0eb-b0839aa18ee5
A simple, fast, sensitive and green pretreatment method for determination of Cd, Co, Hg, Ni, Pb and V in oral and parenteral drug samples using inductively coupled plasma optical emission spectrometry (ICP OES) has been developed. According to United States Pharmacopoeia (USP), those metals must be reported in all pharmaceutical products for quality control evaluation (i.e., elemental impurities from classes 1 and 2A of USP Chapter 232). To improve the analytical capabilities of ICP OES, a dispersive liquid-liquid microextraction (DLLME) has performed using a safe, cheap and biodegradable deep eutectic solvent (DES) as extractant solvent (a mixture of 2:1 molar ratio of DL-menthol and decanoic acid). Seven parameters affecting the microextraction efficiency have carefully optimized by multivariate analysis. Under optimized conditions, the DES-based DLLME-ICP OES procedure improved limit of quantitation (LOQ) values on range from 12 to 85-fold and afforded an enrichment factor on average 60-times higher than those obtained to direct ICP OES analysis. Consequently, LOQ values for Cd, Co, Hg, Ni, Pb and V have been on average 10-times lower than target limits recommended for drugs from parenteral route of administration. Trueness has evaluated by addition and recovery experiments following USP recommendations for three oral drug samples in liquid dosage form and three parenteral drugs. Recovery and RSD values have been within the range of 90-109% and 1-6%, respectively. All analytes were below the repectives LOQ values, hence, lower than the limits proposed by USP Chapter 232.
RUA. Repositorio Institucional de la Universidad de Alicante
Publication Otros (Other)

Reversed-phase dispersive liquid–liquid microextraction for elemental analysis of gasoline by inductively coupled plasma optical emission spectrometry

  • Vidal, Ezequiel
  • Lorenzetti, Anabela S.
  • Álvarez, Mónica B.
  • Domini, Claudia E.
  • Aguirre Pastor, Miguel Ángel
  • Vidal, Lorena
  • Canals, Antonio
  • Aguirre Pastor, Miguel Ángel|||/items/2ded3973-b197-4677-af9e-89db8c79363f
  • Canals, Antonio|||/items/4a7548bb-9862-4dd9-bee4-559e2a77eb23
  • Vidal, Lorena|||/items/87ae49dd-73c8-41be-9c0c-2d3c37772793
In this work a green and fast sample preparation method based on reversed-phase dispersive liquid–liquid microextraction (RP-DLLME) was developed for the separation and preconcentration of several elements (i.e., Ag, As, Ba, Cd, Cr, Cu, Hg, Mn, Mo, Ni, Pb, S, Se, Sn and V) in gasoline samples before determination by Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES). The extraction procedure was carried out in a reverse mode, since a small volume of the aqueous phase (i.e., 8 M HCl) is used to extract a relatively high volume of the organic phase (i.e., gasoline sample). Unlike conventional DLLME, in RP-DLLME the analytes were extracted from the organic phase into the aqueous phase. The experimental conditions for the microextraction procedure were: 5 g of sample, 8 M HCl as the extractant phase, mechanical agitation by vortex as the dispersion system, 115 μL of extractant volume, and 2 min extraction and 5 min centrifugation time. Under optimized extraction conditions the enrichment factor ranged between 3 and 53, and the limits of detection ranged between 0.02 and 50 μg kg−1. The proposed analytical method was validated and successfully used to analyze three gasoline samples. All gasoline samples were spiked at 100 μg kg−1 for all analytes, except sulfur (in this case at 1000 μg kg−1), obtaining recovery and RSD values within the range of 88–109% and 2–9%, respectively.
RUA. Repositorio Institucional de la Universidad de Alicante
Publication Otros (Other)

Magnetic deep eutectic solvents in microextraction techniques

  • Aguirre Pastor, Miguel Ángel
  • Canals, Antonio
  • Aguirre Pastor, Miguel Ángel|||/items/2ded3973-b197-4677-af9e-89db8c79363f
  • Canals, Antonio|||/items/4a7548bb-9862-4dd9-bee4-559e2a77eb23
Magnetic deep eutectic solvents (MDESs) have recently produced a torrent of pioneering applications in endless areas of sample preparation. By including a magnetic nanomaterial (e.g., magnetic nanoparticles) or a paramagnetic anion (e.g., [FeCl4]-) in their structure, MDESs exhibit a strong response under the application of an external magnetic field. Furthermore, the use of MDESs, as a sorbent or solvent in extraction techniques, have been scarcely employed to develop green analytical methods, characterized by the avoid of time-consuming steps and the use of toxic organic solvents, as well as the application of small amounts of MDESs, for the determination of organic and inorganic contaminants, drugs, proteins, among others in environmental, food and biological matrices. This review highlights the application of MDESs in sample preparation in analytical chemistry. Challenges and future outlooks of new MDESs are also presented.
RUA. Repositorio Institucional de la Universidad de Alicante
Publication Otros (Other)

Disolventes eutécticos: nuevas estrategias como fase extractante y como membrana líquida soportada

  • Zapater, Cristina
  • Rubio, Iván
  • Aguirre Pastor, Miguel Ángel
  • Vidal, Lorena
  • Canals, Antonio
  • Zapater, Cristina|||/items/167e0084-0fbb-4747-9758-ade350b2e3e2
  • Rubio, Iván|||/items/772cfa96-2abc-46bb-a27a-eefd47ad6c5d
  • Aguirre Pastor, Miguel Ángel|||/items/2ded3973-b197-4677-af9e-89db8c79363f
  • Vidal, Lorena|||/items/87ae49dd-73c8-41be-9c0c-2d3c37772793
  • Canals, Antonio|||/items/4a7548bb-9862-4dd9-bee4-559e2a77eb23
En el presente estudio se ha evaluado la viabilidad analítica de emplear disolventes eutécticos (DES) hidrofóbicos e hidrofílicos en procedimientos de microextracción. Por un lado, el DES hidrofílico compuesto por cloruro de colina (ChCl) y etilenglicol (EG) (ChCl:EG, relación molar 1:2) se utilizó como fase extractante en la técnica de (micro)extracción líquido-líquido dispersiva (DLLME, Dispersive Liquid-Liquid Microextraction) para la extracción de cuatro bisfenoles (i.e., BPA, BPF, BPAP y BPAF) en aceites comestibles, comparando su rendimiento analítico con el de su compuesto puro (EG) y su variante magnética (ChCl:EG:FeCl3·6H2O, relación molar 1:4:1). Por otro lado, se ha utilizado un DES hidrofóbico como membrana líquida soportada (SLM, Supported Liquid Membrane) en la técnica de extracción por electromembrana (EME, Electromembrane Extraction) de diferentes antiinflamatorios para su determinación en muestras de agua y orina. En ambos estudios, la determinación se realizó mediante cromatografía de líquidos acoplada a un detector de diodos en serie (LC-DAD).
RUA. Repositorio Institucional de la Universidad de Alicante
Publication Otros (Other)

A novel non-invasive colorectal cancer diagnostic method: Volatile organic compounds as biomarkers

  • Alustiza, Miren
  • Ripoll-Seguer, Laura
  • Canals, Antonio
  • Murcia Pomares, Óscar
  • Martínez-Roca, Alejandro
  • García-Heredia, Anabel
  • Giner-Calabuig, Mar
  • Jover, Rodrigo
  • Vidal, Lorena
  • Canals, Antonio|||/items/4a7548bb-9862-4dd9-bee4-559e2a77eb23
  • Vidal, Lorena|||/items/87ae49dd-73c8-41be-9c0c-2d3c37772793
Introduction: Population-based fecal tests for colorectal cancer (CRC) screening have shown to reduce mortality thanks to the early detection of the disease. However, currently available fecal tests are limited in their sensitivity and specificity. Our aim is to look for volatile organic compounds in fecal samples as biomarkers for CRC detection. Material and Methods: Eighty participants were included; 24 had adenocarcinoma, 24 had adenomatous polyps and 32 presented no neoplasms. Fecal samples were collected 48 h preceding the colonoscopy from all participants, except CRC patient samples that were collected after 3–4 weeks from the colonoscopy. Magnetic headspace adsorptive extraction (Mag-HSAE) followed by thermal desorption-gas chromatography-mass spectrometry (TD-GC–MS) was performed on stool samples to identify volatile organic compounds as biomarkers. Results: p-Cresol was significantly more abundant in the cancer samples (P < 0.001) with an area under the curve (AUC) of 0.85 (CI 95%; 0.737–0.953), having a sensitivity and specificity of 83% and 82%, respectively. In addition, 3(4H)-dibenzofuranone,4a,9b-dihydro-8,9b-dimethyl- (3(4H)-DBZ) was also more abundant in the cancer samples (P < 0.001) with an AUC of 0.77 (CI 95%; 0.635–0.905), sensitivity of 78% and specificity of 75%. When combined (p-cresol and 3(4H)-DBZ), the AUC was 0.86, sensitivity 87% and specificity 79%. p-Cresol also appeared to be promising as a biomarker for pre-malignant lesions with an AUC of 0.69 (CI 95%; 0.534–0.862), sensitivity 83% and specificity 63%, P = 0.045. Conclusions: Volatile organic compounds emitted from feces and determined by a sensitive analytical methodology (Mag-HSAE-TD-GC–MS), employing a magnetic graphene oxide as extractant phase, could be used as a potential screening technology for CRC and pre-malignant lesions.