Skip to main content

NANOMATERIALES FUNCIONALES PARA LA VERIFICACION DE PREDICCIONES IN SILICO DE NANOTERMOMETRIA E HIPERTERMIA MAGNETICA

MAT2017-85617-R

•
Funding agency name Agencia Estatal de Investigación
Funding agency acronym AEI
Program Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Call Proyectos I+D+i Retos de Investigación
Call year 2017
State Plan 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Beneficiary centre FUNDACION IMDEA NANOCIENCIA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 2
Encontrada(s) 1 página(s)

RODIN. Repositorio de Objetos de Docencia e Investigación de la Universidad de Cádiz
Research data Set de datos (Dataset)

Dataset from "In silico assessment of collateral eddy current heating in biocompatible implants subjected to magnetic hyperthermia treatments"

  • Rubia-Rodríguez, Irene
  • Zilberti, Luca
  • Arduino, Alessandro
  • Bottauscio, Oriano
  • Chiampi, Mario
  • Ortega Ponce, Daniel
This dataset from the publication entitled "Dataset from "In silico assessment of collateral eddy current heating in biocompatible implants subjected to magnetic hyperthermia treatments" contains simulated data of magnetic hyperthermia treatments for three different indications: colorectal cancer, prostate cancer and head & neck cancer. Since the aim of the study is to evaluate the risk of thermal damage caused by the collateral heating of two common types of passive prostheses (hip and dental implants), eddy currents induced in these implants upon interacting with the externally applied ac field during treatment have been computed for all the evaluated regions. Two different alloys for the implants have been considered for each case as well: Ti6Al4V and CoCrMo. At the same time, besides temperature, the specific abosorption rate (SAR) have been also computed to work out the energy deposition in tissues. Calculations have been carried out using a het exchange model with and without thermoregulation. log-log SAR vs T plots have been obtained and proposed as a quick means to pre-check treatment feasibility in each patient. These graphs are thought to be included in treatment planning prior to the clinical procedure. Other parameters taken into account have been the treatment time (5 and 30 minutes), and the maximum tolerable temperature threshold (1 or 5 ºC, as indicated by the ICNIRP commission), all for three main types of tissues, namely fat, bone and muscle. Each tissue have been simulated using three different field intensities (5, 10 and 15 mT). The field frequency has been 300 kHz in all cases. The files "Dataset_description.doc" and "file_scheme.txt" contain the structure and description of the files that make up the dataset. UPDATES FROM PREVIOUS VERSIONS: simulations of the dental implant without thermoregulation have been added.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Research data Set de datos (Dataset)

Radiomag Interlaboratory Comparison of Magnetic Hyperthermia Characterisation Measurements: Data

  • Wells, J. W.
  • Ortega, Daniel
  • Steinhoff, Uwe
  • Dutz, Silvio
  • Garaio, Eneko
  • Sandre, Olivier
  • Natividad, Eva
  • Cruz, M. M.
  • Brero, Francesca
  • Southern, Paul
  • Pankhurst, Quentin A.
  • Spassov, Simo
These files contain the raw measurement data reported for the Radiomag interlaboratory comparison of magnetic hyperthermia characterisation measurements. Each heating curve for samples containing magnetic nanoparticles is presented in a separate excel file detailing the corrected-slope technique (CST) recalculation of the specific loss power and intrinsic loss power for that measurement as described in the manuscript. The measurements are organised into separate folders for Rounds 1 and 2 of the interlaboratory study, with further subfolders dividing the results for samples 1 and 2. Round 2 also includes the results for the “blank” pure water sample which was included in this Round. For each laboratory there is 3 repeated measurements of each sample during each round the study., This data is based upon work supported by the COST action (RADIOMAG TD1402), supported by COST (European Cooperation in Science and Technology). The financial support of the DFG research grants "quantMPI: Establishment of quantitative Magnetic Particle Imaging (MPI) application oriented phantoms for preclinical investigations" (TR 408/9-1) and "Matrix in Vision" (SFB 1340/1 2018, no 372486779, projects A02 and B02) are also gratefully acknowledged. Additional financial support was received from the Spanish Ministry of Economy and Competitiveness through the grants RED2018-102626-T, MAT2017-85617-R, MAT2017-86826-R and the "Severo Ochoa" Program for Centers of Excellence in R&D (SEV-2016-0686). Additional financial support was received from the Portuguese Foundation for Science and Technology (FCT) under UID/MULTI/04046/2013 (BioISI)., Peer reviewed