Skip to main content

DETECTORES PARA LAS MEJORAS DE ATLAS PARA EL HL-LHC

PID2021-124660OB-C22

•
Funding agency name Agencia Estatal de Investigación
Funding agency acronym AEI
Program Programa Estatal para Impulsar la Investigación Científico-Técnica y su Transferencia
Subprogram Subprograma Estatal de Generación de Conocimiento
Call Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Call year 2021
State Plan 2021-2023 Plan Estatal de Investigación Científica y Técnica y de Innovación
Beneficiary centre AGENCIA ESTATAL CONSEJO SUPERIOR DE INVESTIGACIONES CIENTIFICAS (CSIC)

Resultados relacionados

Resultados totales (Incluyendo duplicados): 6
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Research data Set de datos (Dataset)

Replication data for Characterization of new silicon carbide neutron detectors with thermal and fast neutrons, Pérez, M., Zamorano, F., Fleta, C., Fernández, B., Guerrero, C., Godignon, P.,Pellegrini, G., Pérez-Maroto, P., Guardiola, C. (2024, December). Characterization of new silicon carbide neutron detectors with thermal and fast neutrons [Data management plan]; versión 1

  • Pérez, Martín
  • Zamorano, Felipe
  • Fleta, Celeste
  • Fernández, Begoña
  • Guerrero, Carlos
  • Godignon, Philippe
  • Pellegrini, Giulio
  • Pérez-Maroto, Pablo
  • Guardiola Salmerón, Consuelo
There will not be restrictions to use the generated data after its publication, but external users will be asked to cite the source and/or the papers properly, and the redistribution of the data must be authorized by the researcher/supervisor. The identity of the person accessing the data will be ascertained with the following questionnaire, there won't be a need for a data access committee., Raw data obtained with SiC neutron detectors for the paper: "Characterization of new silicon carbide neutron detectors with thermal and fast neutrons”, European Union Horizon 2022 research and innovation programme under the Marie Sklodowska Curie grant agreement N◦ 101106191 [SiCNeutronFlash]. Consejo de Seguridad Nuclear (CSN) under the project Subvenciones 2022 SUB-08. Spanish Ministry of Science, Innovation and Universities grant number CEX2023-001397-M, and by the European Union’s ERDF program (MCIN/AEI/10.13039/501100011033/) ‘‘A way of making Europe’’ under grant references RTC-2017-6369-3 (FEDER/EU), and PID2021-124660OB-C22., No
DIGITAL.CSIC. Repositorio Institucional del CSIC
Research data Set de datos (Dataset)

Replication data for The effects in fabrication and performance of carbon doping on IMB-CNM manufactured LGADs, Jairo Villegas, Viveka Gautam, Neil Moffat, Lucía Castillo, Giulio Pellegrini, Sebastian Grinstein, Salvador Hidalgo, The effects in fabrication and performance of carbon doping on IMB-CNM manufactured LGADs [Data management plan]; versión 1

DIGITAL.CSIC. Repositorio Institucional del CSIC
Research data Set de datos (Dataset)

Replication data for nLGAD gain response to low-penetrating particles, Villegas, J., Torres, C., Manojlovic, M., Jimenez-Ramos, M. C., Moffat, N., Lopez, J. G., & Hidalgo, S. (2025, March). nLGAD gain response to low-penetrating particles [Data management plan]; versión 1

  • Villegas, Jairo
  • Torres Muñoz, Carmen
  • Manojlovic, Milos
  • Jiménez-Ramos, M. C
  • Moffat, Neil
  • García López, J.
  • Hidalgo, Salvador
There will not be restrictions to use the generated data after its publication, but external users will be asked to cite the source and/or the papers properly, and the redistribution of the data must be authorized by the researcher/supervisor. The identity of the person accessing the data will be ascertained with the following questionnaire, there won't be a need for a data access committee., Raw data obtained with nLGAD silicon detectors fabricated at IMB-CNM-CSIC for the paper: "nLGAD gain response to low-penetrating particles”, Spanish Ministry of Science, Innovation and Universities (MICIU/AEI/10.13039/501100011033/) and by the European Union’s ERDF program “A way of making Europe”. Grant references: CEX2023-001397-M, PID2020-113705RB-C32, PID2021-124660OB-C22, PDC2021-121718-C32 and PDC2023-145925-C32 European Union’s Horizon 2020 Research and Innovation. Grant Agreement No. 101004761 (AIDAInnova) NextGenerationEU, Spain (PRTR-C17.I1). CNA is also partially funded by the ASTRO21/1.1/1 (European Union- NextGenerationEU, the Ministry of Science, Innovation and Universities, Recovery Plan, Transformation and Resilience, Spain, the Department of University, Research and Innovation of the Junta de Andalucia and the University of Sevilla)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Research data Set de datos (Dataset)

Replication data for Position-resolved charge collection of silicon carbide detectors with an epitaxially-grown graphene layer, Lopez Paz, I., Godignon, P., Moffat, N. et al. Position-resolved charge collection of silicon carbide detectors with an epitaxially-grown graphene layer. Sci Rep 14, 10376 (2024)

  • Lopez Paz, Ivan
  • Godignon, Philippe
  • Moffat, Neil
  • Pellegrini, Giulio
  • Rafí, Joan Marc
  • Rius, Gemma
Silicon carbide (SiC) has outstanding physical properties therefore, diodes based on SiC are being considered for many radiation detection applications such as particle accelerator experiments and medical dosimetry. Moreover, by reducing the metal on the surface of the diode there is the potential to enhance its performance in some fields where the presence of metal is detrimental. To this end, SiC detectors with an epitaxially-grown graphene layer (EG), that substitutes the metallic contact, in the sensitive region were produced at IMB-CNM, profiting from the conductivity of the mono-atomic layer material. To isolate the effect of the graphene on the charge collection, samples without graphene were produced in parallel. In this paper, the effect of EG on Silicon Carbide p-in-n radiation detectors is studied in terms of charge collection with a radioactive source and by means of the transient current technique (TCT), which allows for position-dependent signal formation analysis. As a result of the former, we show the capability of the EG-SiC sensor for charge collection after signal integration, to a resolution close to that of a sensor fully metallised. Moreover, from the TCT studies, we observe uniform charge collection across the active region, as well as an up-to ∼40% transient amplitude damping which, compared with the ∼90% on the sample containing no metallic contact, proves that the presence of graphene benefits the performance of the device and that the technology is viable for radiation detection as an alternative to metal. © The Author(s) 2024., This work has been funded by the Spanish Ministry of Science and Innovation (MCIN/AEI/10.13039/501100011033/) and by the European Union\u2019s ERDF program \u201CA way of making Europe\u201D.Grant references: PID2021-124660OB-C22 and by the European Union\u2019s Horizon 2020 Research and Innovation funding program, under Grant Agreement No. 101004761 (AIDAInnova). Support from Ayudas Ramon y Cajal Ref. RYC-2016-21412 is also acknowledged., The transient signals obtained under the triple-alpha radioactive source set-up are shown in Fig. 5. The waveforms obtained from all samples showcase a dip after the main transient pulse attributed to an impedance mismatch, causing a reflection. The integration window in Sample-1M was chosen before this undershoot, since the pulses from charge collection are faster. However, as the signals are longer in the other samples, the integration window for the charge determination is chosen longer, which in turn results in an under-estimation of the charge collection. Amplitude distribution for all samples under a bias voltage of -500 V are shown in Fig. 6 (left). Notably, Sample-1 has an overall lower amplitude distribution, although Sample-1M is the only detector showcasing the three peaks expected from the three alpha particle energies from the radioactive source. However - after integration - the same features appear in Sample-1G, as shown in Fig. 6 (right). As it will be observed in the following sections in more detail, the apparent charge collection loss in Sample-1 is a result of the higher resistance observed by the transient signal before reaching the bias ring with respect to the other samples, which reduces the waveform amplitudes away from it, to the point where noise is a large contribution in the integration. A 30 ns extra integration window was used in Sample-1 in order to recover charge levels comparable to Samples-1G and -1M. The same damping effect is seen in Sample-1G to a lesser degree., No
DIGITAL.CSIC. Repositorio Institucional del CSIC
Research data Set de datos (Dataset)

Replication data for Evaluation of a silicon carbide P–N diode for thermal neutron detection in a radiotherapy LINAC, Perez, M.; Zamorano, F.; Fleta, C.; Muñoz-Montplet, C.; Jurado-Bruggeman, D.; Jimenez, M.; Guardia, P.; Grabulosa-Morera, G.; Morales-Pérez, R.; Rius, G.; Godignon, P.; Pellegrini, G.; Guardiola, C.; Evaluation of a silicon carbide P–N diode for thermal neutron detection in a radiotherapy LINAC [Data management plan]; versión 1

  • Pérez, Martín
  • Zamorano, Felipe
  • Fleta, Celeste
  • Muñoz-Montplet, Carles
  • Jurado-Bruggeman, Diego
  • Jimenez, Marcio
  • Guardia, Pablo
  • Grabulosa-Morera, Gina
  • Morales-Pérez, Roger
  • Rius, Gemma
  • Godignon, Philippe
  • Pellegrini, Giulio
  • Guardiola Salmerón, Consuelo
There will not be restrictions to use the generated data after its publication, but external users will be asked to cite the source and/or the papers properly, and the redistribution of the data must be authorized by the researcher/supervisor. The identity of the person accessing the data will be ascertained with the following questionnaire, there won't be a need for a data access committee., Raw data obtained with SiC neutron detectors for the paper "Evaluation of a silicon carbide P–N diode for thermal neutron detection in a radiotherapy LINAC", European Union Horizon 2022 research and innovation program under the Marie Sklodowska-Curie grant agreement N◦ 101106191; Consejo de Seguridad Nuclear (CSN) under the project Subvenciones 2022 SUB-08 Spanish Ministry of Science and Innovation (MCIN/AEI/10.13039/501100011033/). European Union ERDF program ’A way of making Europe’. Grant references: PID2021-124660OB-C22. Spanish government through the ’María de Maeztu Unit of Excelence’ accreditation (CEX2023-001397-M). MCIN/AEI/10.13039/501100011033 (Grant No. CNS2022-13558).'Severo Ochoa' Programme for Center of Excellence in R&D funded by MCIN and by FEDER, “A way of making Europe” (Grant No. CEX2023-001263-S). P. G. acknowledges financial support from the Ramon y Cajal program funded by the MCIN/AEI/10.13039/501100011033 and the “FSE invierte en tu futuro” (Grant No. RYC2019-028414)., No
DIGITAL.CSIC. Repositorio Institucional del CSIC
Research data Set de datos (Dataset)

Replication data for Experimental Evaluation of Silicon Carbide P-N Detectors Under Thermal and Fast Neutron Irradiation at the RA-6 Nuclear Research Reactor, Martín Pérez; Juan Jerónimo Blostein; Felipe Zamorano; Celeste Fleta; Julio Marín; Giulio Pellegrini; Consuelo Guardiola, Experimental Evaluation of Silicon Carbide P-N Detectors Under Thermal and Fast Neutron Irradiation at the RA-6 Nuclear Research Reactor [Data management plan]; versión 1

  • Pérez, Martín
  • Blostein, Juan Jerónimo
  • Zamorano, Felipe
  • Fleta, Celeste
  • Marín, Julio
  • Pellegrini, Giulio
  • Guardiola Salmerón, Consuelo
There will not be restrictions to use the generated data after its publication, but external users will be asked to cite the source and/or the papers properly, and the redistribution of the data must be authorized by the researcher/supervisor. The identity of the person accessing the data will be ascertained with the following questionnaire, there won't be a need for a data access committee., Raw data obtained with SiC neutron detectors for the paper: "Characterization of new silicon carbide neutron detectors with thermal and fast neutrons”, This project has received funding from the European Union Horizon 2022 research and innovation program under the Marie Sklodowska-Curie grant agreement N°101106191. This work has also been funded by the Consejo de Seguridad Nuclear (CSN) under the project Subvenciones 2022 SUB-08, and by the Spanish Ministry of Science and Innovation (MCIN/AEI/10.13039/501100011033/) and by the European Union ERDF program ’A way of making Europe’. Grant references: PID2021-124660OB-C22. This work has also been founded by the Spanish government through the ’María de Maeztu Unit of Excellence’ accreditation (CEX2023-001397-M). This work was partially funded by the MCIN/AEI/10.13039/501100011033 (Grant No. CNS2022-13558), and the ‘Severo Ochoa’ Programme for Center of Excellence in R&D funded by MCIN and by FEDER, “A way of making Europe” (Grant No. CEX2023-001263-S). This work has also been funded by the projects PICT-2020-01016 and ICT-2020-03065, ANPCyT; PIP CONICET 11220200103237; and SIIP UNCuyo Cód. 06/C055-T1, Argentina., Peer reviewed