Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 37
Encontrada(s) 1 página(s)

Digibug. Repositorio Institucional de la Universidad de Granada
Publication Artículo científico (JournalArticle)

Scintillation light in SBND: simulation, reconstruction, and expected performance of the photon detection system

  • Abratenko, P.
  • Bueno Villar, Antonio|||0000-0002-7439-4247
  • García Gámez, Diego|||0000-0003-3203-6553
  • Nicolás Arnaldos, Francisco Javier
  • Pelegrina Gutiérrez, Luis
  • Sáncehz Castillo, Alejandro
  • Sánchez Lucas, Patricia
  • Vázquez Ramos, Alicia
  • Zamorano García, Bruno
  • SBND Collaboration
SBND is the near detector of the Short-Baseline Neutrino program at Fermilab. Its location near to theBooster Neutrino Beam source and relatively large mass will allow the study of neutrino interactions on argon with unprecedented statistics. This paper describes the expected performance of the SBND photon detection system, using a simulated sample of beam neutrinos and cosmogenic particles. Its design is a dual readout concept combining a system of 120 photomultiplier tubes, used for triggering, with a system of 192 X-ARAPUCA devices, located behind the anode wire planes. Furthermore, covering the cathode plane with highly-reflective panels coated with a wavelength-shifting compound recovers part of the light emitted towards the cathode, where no optical detectors exist.We show how this new design provides a high light yield and a more uniform detection efficiency, an excellent timing resolution and an independent 3D-position reconstruction using only the scintillation light. Finally, the whole reconstruction chain is applied to recover the temporal structure of the beam spill, which is resolved with a resolution on the order of nanoseconds., The U.S. Department of Energy, Office of Science, Office of High Energy Physics, The U.S. National Science Foundation, The Science and Technology Facilities Council (STFC), part ofUnitedKingdom Research and Innovation, The Royal Society of the United Kingdom, and the UK Research and Innovation (UKRI) Future Leaders Fellowship, The Swiss National Science Foundation, The Spanish Ministerio de Ciencia e Innovación (MICIN/ AEI/ 10.13039/ 501100011033) under grants No PRE2019-090468, PID2019-104676GB-C31 and C32, RYC2022-036471-I, and Comunidad deMadrid (2019-T2/TIC-13649), The European Union’s Horizon 2020 research and innovation programme under GA no 101004761 and the Marie Sklodowska-Curie Grant agreements nos. 822185 and 892933, The São Paulo Research Foundation 1098 (FAPESP), the National Council of Scientific and Technological Development (CNPq) and Ministry of Science, Technology and Innovations-MCTI of Brazil, Los Alamos National Laboratory for LDRD funding, Fermilab ismanaged by Fermi Research Alliance, LLC (FRA), acting under Contract no. DE-AC02-07CH11359
Minerva. Repositorio Institucional de la Universidad de Santiago de Compostela
Publication Artículo científico (JournalArticle)

Primary scintillation yields induced by α particles in gas mixtures of Argon/CF4 at 9.5 bar

  • Amedo, Pablo
  • Leardini, Sara
  • Saá Hernández, Ángela
  • González Díaz, Diego
We report time and band -resolved scintillation from α-particles in Ar/CF4 mixtures at a pressure of 9.5 bar. Our results show that %-level addition of CF4 enables strong wavelength-shifted scintillation in the visible range, with yields at the level of 1000 ph/MeV, scintillation decay times of 9–25 ns and formation times well below 10 ns. Such a performance is a priori sufficient for accurate time-tagging of MeV-particles, without the need to resort to a pure noble gas, thus opening an appealing technological path for next-generation time projection chambers.
Investigo. Repositorio Institucional de la Universidade de Vigo
Publication Artículo científico (JournalArticle)

On the determination of the interaction time of GeV neutrinos in large argon gas TPCs

  • Saá Hernández, A.
  • González Díaz, D.
  • Martín Albo, J.
  • Tuzi, M.
  • Amedo, P.
  • González Baldonedo, Jacobo
  • Benítez, C.
  • Bounasser, S.
  • Casarejos Ruiz, Enrique
  • Collazo Rodriguez, Joaquin Baltasar
  • Fernández Prieto, A.
  • Fernández Posada, D.J.
  • Hafeji, R.
  • Leardini, S.
  • Rodas Rodríguez, D.
  • Saborido, A. L.
  • Segade Robleda, Abraham
  • Slater, A.
Next-generation megawatt-scale neutrino beams open the way to studying neutrino-nucleus scattering using gaseous targets for the first time. This represents an opportunity to improve the knowledge of neutrino cross sections in the energy region between hundreds of MeV and a few GeV, of interest for the upcoming generation of long-baseline neutrino oscillation experiments. The challenge is to accurately track and (especially) time the particles produced in neutrino interactions in large and seamless volumes down to few-MeV energies. We propose to accomplish this through an optically-read time projection chamber (TPC) filled with high-pressure argon and equipped with both tracking and timing functions. In this work, we present a detailed study of the time-tagging capabilities of such a device, based on end-to-end optical simulations that include the effect of photon propagation, photosensor response, dark count rate and pulse reconstruction. We show that the neutrino interaction time can be reconstructed from the primary scintillation signal with a precision in the range of 1–2.5 ns $$(\sigma )$$(σ) for point-like deposits with energies down to 5 MeV. A similar response is observed for minimum-ionizing particle tracks extending over lengths of a few meters. A discussion on previous limitations towards such a detection technology, and how they can be realistically overcome in the near future thanks to recent developments in the field, is presented. The performance demonstrated in our analysis seems to be well within reach of next-generation neutrino-oscillation experiments, through the instrumentation of the proposed TPC with conventional reflective materials and a silicon photomultiplier array behind a transparent cathode., Xunta de Galicia, Generalitat Valenciana | Ref. CIDEGENT/2019/049, Ministerio de Economía y Competitividad | Ref. RYC-2015-18820, Agencia Estatal de Investigación | Ref. RYC2021-033265-I, Ministerio de Economía, Industria y Competitividad | Ref. MDM-2016-0692, Agencia Estatal de Investigación | Ref. PID2021-125028OB-C21
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

First observation of the charge carrier density related gain reduction mechanism in LGADs with the Two Photon Absorption-Transient Current Technique

  • Pape, Sebastian
  • Currás, Esteban
  • Fernández-García, Marcos
  • Moll, Michael
  • Montero Santos, Raúl
  • Palomo, Francisco Rogelio
  • Vila, Iván
  • Wiehe, Moritz
  • Quintana San Emeterio, Cristian
The Low Gain Avalanche Detector (LGAD) technology is very promising for silicon timing detectors and currently heavily researched. Recent studies show that the gain of LGADs highly depends on the charge carrier density inside the gain layer. To study the charge carrier density related gain reduction, the Two Photon Absorption-Transient Current Technique (TPA-TCT) was employed to obtain information on the drift velocity and electric field of a LGAD for different charge carrier densities. The TPA-TCT uses fs-pulse infrared lasers to provide a three-dimensional resolution to study bulk effects. A compact TPA-TCT setup was developed at CERN and is used to measure current transients against the device depth of a 285μ thick PIN and LGAD, fabricated by IMB-CNM. Methods to extract information about the electric field are employed to verify the charge carrier density related gain reduction. The gain layer of the LGAD is spatially resolved for the first time., This project was performed within the framework of RD50 and has received funding from the European Union’s Horizon 2020 Research and Innovation programme under GA no 101004761 (AIDAinnova), the Wolfgang Gentner Program of the German Federal Ministry of Education and Research (grant no. 05E18CHA), the Spanish Ministry of Science (grant no. PID2020-113705RB-C31), and the CERN Knowledge Transfer Fund , through a grant awarded in 2017., Peer reviewed, Código proyecto: PID2020-113705RB-C31
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Inverse LGAD (iLGAD) Periphery Optimization for Surface Damage Irradiation

  • Doblas, Albert
  • Flores, David
  • Hidalgo, Salvador
  • Moffat, Neil
  • Pellegrini, Giulio
  • Quirion, David
  • Villegas, Jairo
  • Maneuski, Dzmitry
  • Ruat, Marie
  • Fajardo, Pablo
Pixelated LGADs have been established as the baseline technology for timing detectors for the High Granularity Timing Detector (HGTD) and the Endcap Timing Layer (ETL) of the ATLAS and CMS experiments, respectively. The drawback of segmenting an LGAD is the non-gain area present between pixels and the consequent reduction in the fill factor. To overcome this issue, the inverse LGAD (iLGAD) technology has been proposed by IMB-CNM to enhance the fill factor and provide excellent tracking capabilities. In this work, we explore the use of iLGAD sensors for surface damage irradiation by developing a new generation of iLGADs, the periphery of which is optimized to improve the performance of irradiated sensors. The fabricated iLGAD sensors exhibit good electrical performances before and after X-ray irradiation., This work has been funded by the Spanish Ministry of Science and Innovation (MCIN/AEI/10.13039/501100011033/) and by the European Union’s ERDF program “A way of making Europe”. Grant references: RTI2018-094906-B-C22 and PID2020-113705RB-C32. Also, it was funded by the European Union’s Horizon 2020 Research and Innovation funding program, under Grant Agreement No. 101004761 (AIDAInnova), and by the European Synchrotron Radiation Facility (ESRF)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Fiber laser system of 1550 nm femtosecond pulses with configurable properties for the two-photon excitation of transient currents in semiconductor detectors

  • Almagro-Ruiz, Azahara
  • Pape, Sebastian
  • Muñoz-Marco, Héctor
  • Wiehe, Moritz
  • Currás, Esteban
  • Fernández-García, Marcos
  • Moll, Michael
  • Montero Santos, Raúl
  • Palomo, Francisco Rogelio
  • Quintana San Emeterio, Cristian
  • Vila, Iván
  • Pérez-Millán, Pere
A fiber laser system emitting ultrashort femtosecond pulses at 1550 nm with configurable properties has been developed as an excitation source for the two-photon absorption transient current technique (TPA-TCT). The modules of the system are designed to provide the optical specifications required at the output for localized characterization of semiconductor radiation detectors: variation of pulse energy between 10 nJ and 10pJ , variation of the pulse repetition rate from 8.2 MHz to single shot, and variation of pulse duration between 300 and 600 fs. The validity of the system as an excitation source in the TPA-TCT is demonstrated by measuring spatially resolved excited charge carriers in a silicon detector., Ministerio de Ciencia e Innovación (PID2020113705RB-C31, DI-15-07461, DI-17-09578); Generalitat Valenciana (IVACE-IMIDTA/2020/32); Bundesministerium für Bildung und Forschung—Wolfgang Gentner Program (05E18CHA); Horizon 2020 Framework Programme (H2020 Research and Innovation Program)—AIDA Innova project (101004761)., Peer reviewed, Código proyecto:
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Study of irradiated 3D pixel sensors from CNM

  • Lasaosa, Clara
The High-Luminosity upgrade of the Large Hadron Collider will force the experiments to cope with harsh radiation environments. The CMS Collaboration has decided to install 3D pixel sensors in the innermost barrel layer of the tracking system, which has to face a fluence of 2x10(16) n.eqcm(-2) before replacement. This pixel technology should maintain high detection efficiency and manageable power dissipation at such unprecedented fluences. Results from beam test experiments with 3D pixel sensors fabricated at IMB-CNM and bump-bonded to RD53A readout chips are presented. The irradiation with protons of 400 MeV-momentum to fluences of roughly 1.3– 2x10(16) n.eqcm(-2) as well as the measurement of these sensors in a test beam have been both performed at Fermilab., This project has received funding from the European Union’s Horizon 2020 Research and Innovation programme under grant agreement No 101004761 and from the Spanish Agencia Estatal de Investigacion under grants PID2020-113705RB-C31 and PID2020-113705RB-C32., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Techniques for the investigation of segmented sensors using the two photon absorption-transient current technique

  • Pape, Sebastian
  • Currás, Esteban
  • Fernández-García, Marcos
  • Moll, Michael
This article belongs to the Special Issue Radiation Sensors and Detectors: Materials, Principles and Applications., The two photon absorption-transient current technique (TPA-TCT) was used to investigate a silicon strip detector with illumination from the top. Measurement and analysis techniques for the TPA-TCT of segmented devices are presented and discussed using a passive strip CMOS detector and a standard strip detector as an example. The influence of laser beam clipping and reflection is shown, and a method that allows to compensate these intensity-related effects for investigation of the electric field is introduced and successfully employed. Additionally, the mirror technique is introduced, which exploits reflection at a metallised back side to enable the measurement directly below a top metallisation while illuminating from the top., This project was performed within the framework of RD50 and has received funding from the European Union’s Horizon 2020 Research and Innovation programme under GA no 101004761 (AIDAinnova), the Wolfgang Gentner Program of the German Federal Ministry of Education and Research (grant no. 05E18CHA), and the CERN Knowledge Transfer Fund, through a grant awarded in 2017., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Influence of temperature on measurements of the two photon absorption – transient current technique in silicon planar detectors using a 1550 nm femtosecond fibre laser

  • Pape, Sebastian
  • Currás, Esteban
  • Fernández-García, Marcos
  • Moll, Michael
  • Wiehe, Moritz
The effect of temperature on the excess charge carrier generation and collection, injected using two photon absorption at a wavelength of 1550 nm, is investigated in a 285 Ωm thick, p-type silicon planar detector, with a bulk resistivity of 3.7 kΩ cm. Charge collection measurements are performed for temperatures between −20 °C to 20 °C. The collected charge decreases by about 8% when the temperature is lowered from 20 °C to −20 °C, which is linked to a decreasing excess charge carrier generation. Further, a decreasing time over threshold is observed for decreasing temperatures, which is associated to an increasing charge carrier mobility., This project was performed within the framework of RD50 and has received funding from the European Union’s Horizon 2020 Research and Innovation programme under GA no 101004761 (AIDAinnova), the Wolfgang Gentner Program of the German Federal Ministry of Education and Research (grant no. 05E18CHA), and the CERN, Switzerland Knowledge Transfer Fund, through a grant awarded in 2017., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Timing performance and gain degradation after irradiation with protons and neutrons of Low Gain Avalanche Diodes based on a shallow and broad multiplication layer in a float-zone 35μm and 50μm thick silicon substrate

  • Currás, Esteban
  • Doblas, Albert
  • Fernández-García, Marcos
  • Flores, David
  • González, Javier
  • Hidalgo, Salvador
  • Jaramillo, R.
  • Moll, Michael
  • Navarrete Ramos, Efrén
  • Pellegrini, Giulio
  • Vila, Iván
The high-luminosity upgrade of the ATLAS and CMS experiments includes dedicated sub-detectors to perform the time-stamping of minimum ionizing particles (MIPs). These detectors will be exposed up to fluences in the range of 1.5–2.5 × 1015 𝑛𝑒𝑞∕cm2 and require a time resolution per detecting layer of 30 ps, for non-irradiated sensors, to 50–70 ps (depending on the exposed fluences) for sensors at the end of their lifetime. To cope with these requirements, the low-gain avalanche diode (LGAD) has been chosen as the baseline detection technology. In this article, an in-depth radiation tolerance study on LGADs manufactured at IMB-CNM using a so-called shallow junction is presented. Proton irradiation at CERN-PS up to fluences of 3 × 1015 𝑛𝑒𝑞∕cm2 and neutron irradiation at JSI-Ljubljana up to 2.5 × 1015 𝑛𝑒𝑞∕cm2 were performed. Two different active thicknesses were studied: 35 μm and 50 μm. Gain degradation, operation stability, and timing performance were evaluated., This work was developed in the framework of the RD-50 collaboration and has been supported by the Spanish Ministry of Science and Innovation (MCIN/AEI/10.13039/501100011033/), by the European Union’s ERDF program “A way of making Europe” (Grant References PID2020-113705RB-C31, PID2020-113705RB-C32, and PID2021-124660OB-C22) and by the European Union’s Horizon 2020 Research and Innovation funding program , under Grant Agreement no. 101004761 (AIDAInnova). We thank Dr. Miquel Vellvehi and Dr. Xavier Perpiña (IMB-CNM-CSIC) for their work in performing the thermographic measurements., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Gain measurements on NLGAD detectors

  • Villegas, Jairo
  • Moffat, Neil
  • Maneuski, Dzmitry
  • Ferrer, Oscar
  • Pellegrini, Giulio
  • Hidalgo, Salvador
In the last few years, Low Gain Avalanche Detectors (LGAD) have demonstrated their outstanding performance when detecting high-energy charged particles. However, due to the difference in the multiplication mechanism for holes and electrons, the detection performance for low penetrating particles (e.g low-energy protons or soft x-rays) is significantly reduced. A novel design of an LGAD detector, the NLGAD, was designed and fabricated at CNM to overcome this drawback. A qualitative description of the NLGAD concept is presented in this work, along with gain response measurements of the first prototypes under visible light of 660 nm and 15 keV x-rays. Additionally, a review of the gain response under visible light of 404 nm and IR light of 1064 nm, previously studied, is also evaluated in this work. The results demonstrate that the NLGAD concept has the potential to detect low penetrating particles., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Towards a muon collider

  • Accettura, C.
  • Zurita, Jose
A muon collider would enable the big jump ahead in energy reach that is needed for a fruitful exploration of fundamental interactions. The challenges of producing muon collisions at high luminosity and 10 TeV centre of mass energy are being investigated by the recently-formed International Muon Collider Collaboration. This Review summarises the status and the recent advances on muon colliders design, physics and detector studies. The aim is to provide a global perspective of the field and to outline directions for future work., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

CMOS MAPS upgrade for the Belle II Vertex Detector

  • Babeluk, M.
  • Barbero, M.
  • Baudot, J.
  • Bergauer, T.
  • Bernlochner, Florian Urs
  • Bettarini, S.
  • Bosi, F.
  • Buch, Y.
  • Casarosa, G.
  • Dingfelder, J.
  • Fillinger, T.
  • Finck, C.
  • Frey, A.
  • Hu, C.
  • Irmler, C.
  • Mariñas Pardo, Carlos
  • Massaccesi, L.
  • Minuti, M.
  • Pham, H.
  • Rizzo, G.
  • Schwanda, C.
  • Schwenker, B.
  • Schwickardi, M.
  • Wessel, C.
The success of the Belle II experiment in Japan relies on the very high instantaneous luminosity, close to 6×10 cm s, expected from the SuperKEKB collider. The corresponding beam conditions at such luminosity levels generate large rates of background particles and creates stringent constraints on the vertex detector, adding to the physics requirements. Current prospects for the occupancy rates in the present vertex detector (VXD) at full luminosity fall close to the acceptable limits and bear large uncertainties. In this context, the Belle II collaboration is considering the possibility to install an upgraded VXD system around 2027 to provide a sufficient safety margin with respect to the expected background rate and possibly enhance tracking and vertexing performance. The VTX collaboration has started the design of a fully pixelated VXD, called VTX, based on fast and highly granular Depleted Monolithic Active Pixel Sensors (DMAPS) integrated on light support structures. The two main technical features of the VTX proposal are the usage of a single sensor type over all the layers of the system and the overall material budget below 2% of radiation length, compared to the current VXD which has two different sensor technologies and about 3% of radiation length. A dedicated sensor (OBELIX), taylored to the specific needs of Belle II, is under development, evolving from the existing TJ-Monopix2 sensor. The time-stamping precision below 100 ns will allow all VTX layers to take part in the track finding strategy contrary to the current situation. The first two detection layers are designed according to a self-supported all-silicon ladder concept, where 4 contiguous sensors are diced out of a wafer, thinned and interconnected with post-processed redistribution layers. The outermost detection layers follow a more conventional approach with a cold plate and carbon fibre support structure, and light flex cables interconnecting the sensors. This document will review the context, technical details and development status of the proposed Belle II VTX., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Measured and projected beam backgrounds in the Belle II experiment at the SuperKEKB collider

  • Natochii, A.
  • Browder, T. E.
  • Cao, L.
  • Cautero,G.
  • Dreyer, S.
  • Frey, Ariane
  • Gabrielli, Alice
  • Giuressi, Dario
  • Ishibashi, Takuya
  • Jin,Y.
  • Kojima, K.
  • Kraetzschmar, T.
  • Lanceri, L.
  • Liptak,Z.
  • Liventsev, D.
  • Mariñas Pardo, Carlos
  • Massaccesi, L.
  • Matsuoka, K.
  • Meier,F.
  • Miller, C.
  • Nakayama, H.
  • Niebuhr,C.
  • Novosel, A.
  • Parham,K.
  • Popov,I.
  • Rizzo, G.
  • Roney, J. M.
  • Ryu, S. Y.
  • Santelj, L.
  • Schneider, S.
  • Schueler, J.
  • Schwenker, B.
  • Shi, X. D.
  • Simon, F.
  • Stefkova,S.
  • Takahashi, M.
  • Tanigawa, H.
  • Taniguchi,N.
  • Terui, S.
  • Vahsen, S. E.
  • Vitale,L.
  • Vossen, A.
  • Wang,Z.
  • Wiechczynski,J.
  • Windel, H.
  • Yoshihara,K.
28 pages, 17 figures, 9 tables (revised); in v3, we corrected Table 5 units for the measured fast neutron fluence by the TPC detectors from x10^9 n_eq/cm^2 to x10^8 n_eq/cm^2, which was a typo in the previous versions; also, we added the value of the luminosity for Tables 5 and 6, The Belle II experiment at the SuperKEKB electron-positron collider aims to collect an unprecedented data set of $50~{\rm ab}^{-1}$ to study $CP$-violation in the $B$-meson system and to search for Physics beyond the Standard Model. SuperKEKB is already the world's highest-luminosity collider. In order to collect the planned data set within approximately one decade, the target is to reach a peak luminosity of $\rm 6 \times 10^{35}~cm^{-2}s^{-1}$ by further increasing the beam currents and reducing the beam size at the interaction point by squeezing the betatron function down to $\beta^{*}_{\rm y}=\rm 0.3~mm$. To ensure detector longevity and maintain good reconstruction performance, beam backgrounds must remain well controlled. We report on current background rates in Belle II and compare these against simulation. We find that a number of recent refinements have significantly improved the background simulation accuracy. Finally, we estimate the safety margins going forward. We predict that backgrounds should remain high but acceptable until a luminosity of at least $\rm 2.8 \times 10^{35}~cm^{-2}s^{-1}$ is reached for $\beta^{*}_{\rm y}=\rm 0.6~mm$. At this point, the most vulnerable Belle II detectors, the Time-of-Propagation (TOP) particle identification system and the Central Drift Chamber (CDC), have predicted background hit rates from single-beam and luminosity backgrounds that add up to approximately half of the maximum acceptable rates., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

RD50-MPW3: a fully monolithic digital CMOS sensor for future tracking detectors

  • Sieberer, Patrick
  • Zhang, Chenfan
  • Bergauer, Thomas
  • Mohr, Raimon Casanova
  • Irmler, Christian
  • Karim, Nissar
  • Mazorra De Cos, J.
  • Pilsl, Bernhard
  • Vilella, Eva
The CERN-RD50 CMOS working group develops the RD50-MPW series of monolithic high-voltage CMOS pixel sensors for potential use in future high luminosity experiments such as the HL-LHC and FCC-hh. In this contribution, the design of the latest prototype in this series, RD50-MPW3, is presented. An overview of its pixel matrix and digital readout periphery is given, with discussion of the new structures implemented in the chip and the problems they aim to solve. The main analogue and digital features of the sensor are already tested and initial laboratory characterisation of the chip is presented.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Study of neutron-, proton-, and gamma-irradiated silicon detectors using the two-photon absorption–transient current technique

  • Pape, Sebastian
  • Fernández-García, Marcos
  • Moll, Michael
  • Wiehe, Moritz
This article belongs to the Special Issue Radiation Sensors and Detectors: Materials, Principles and Applications., The Two-Photon Absorption-Transient Current Technique (TPA-TCT) is a device characterisation technique that enables three-dimensional spatial resolution. Laser light in the quadratic absorption regime is employed to generate excess charge carriers only in a small volume around the focal spot. The drift of the excess charge carriers is studied to obtain information about the device under test. Neutron-, proton-, and gamma-irradiated p-type pad silicon detectors up to equivalent fluences of about 7 × 1015 neq/cm2 and a dose of 186 Mrad are investigated to study irradiation-induced effects on the TPA-TCT. Neutron and proton irradiation lead to additional linear absorption, which does not occur in gamma-irradiated detectors. The additional absorption is related to cluster damage, and the absorption scales according to the non-ionising energy loss. The influence of irradiation on the two-photon absorption coefficient is investigated, as well as potential laser beam depletion by the irradiation-induced linear absorption. Further, the electric field in neutron- and proton-irradiated pad detectors at an equivalent fluence of about 7 × 1015 neq/cm2 is investigated, where the space charge of the proton-irradiated devices appears inverted compared to the neutron-irradiated device., This project was performed within the framework of RD50 and DRD3 and has received funding from the European Union’s Horizon 2020 Research and Innovation programme under GA no 101004761 (AIDAinnova), the Wolfgang Gentner Program of the German Federal Ministry of Education and Research (grant no. 05E18CHA), and the CERN Knowledge Transfer Fund, through a grant awarded in 2017, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

nLGAD gain response to low-penetrating particles

  • Villegas, Jairo
  • Torres Muñoz, Carmen
  • Manojlovic, Milos
  • Jiménez-Ramos, M. C.
  • Moffat, Neil
  • García López, J.
  • Hidalgo, Salvador
Detecting low-penetrating particles is fundamental for a wide range of applications in the fields of industry, medicine, and pure research. The Low Gain Avalanche Detector built on n-type substrates (nLGAD) is considered a good candidate for that, as it showed to have the potential to detect such particles with high sensitivity while avoiding the high noise levels associated with a traditional avalanche photodetector. An overview of the electrical characterization of the latest nLGAD batch fabricated at the Institute of Microelectronics of Barcelona is presented in this work. Additionally, gain response measurements for light with varying penetration depths in silicon and 600 keV protons are also presented. The results confirm the aforementioned potential of nLGADs to detect low-penetrating particles in silicon. Additionally, it was observed that the gain response of the devices is not only dependent on the penetration depth of the studied particles, but also on the nature and flux of the source., This work has been funded by the Spanish Ministry of Science, Innovation and Universities (MICIU/AEI/10.13039/501100011033/) and by the European Union’s ERDF program “A way of making Europe”. Grant references: PID2020-113705RB-C32, PID2021-124660OB-C22, PDC2021-121718-C32 and PDC2023-145925-C32. Also, it was supported by the following European funding programs: European Union’s Horizon 2020 Research and Innovation (under Grant Agreement No. 101004761, AIDAInnova) and NextGenerationEU (PRTR-C17.I1). M. Carmen Jimenez-Ramos acknowledges the support of this work through a VI PPIT-US contract. This investigation has also been partially financed by the project ref. ASTRO21/1.1/1 with financing from the European Union- NextGenerationEU, the Ministry of Science, Innovation and Universities, Recovery Plan, Transformation and Resilience, Spain, the Department of University, Research and Innovation of the Junta de Andalucia and the University of Sevilla, Spain ., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

TCAD Simulation of two photon absorption—Transient current technique measurements on silicon detectors and LGADs

  • Pape, Sebastian
  • Moll, Michael
  • Fernández-García, Marcos
  • Wiehe, Moritz
This article belongs to the Special Issue Radiation Sensors and Detectors: Materials, Principles and Applications (2nd Edition)., Device simulation plays a crucial role in complementing experimental device characterisation by enabling deeper understanding of internal physical processes. However, for simulations to be trusted, experimental validation is essential to confirm the accuracy of the conclusions drawn. In the framework of semiconductor detector characterisation, one powerful tool for such validation is the Two Photon Absorption-Transient Current Technique (TPA-TCT), which allows for highly precise, three-dimensional spatially-resolved characterisation of semiconductor detectors. In this work, the TCAD framework Synopsys Sentaurus is used to simulate depth-resolved TPA-TCT data for both p-type pad detectors (PINs) and Low Gain Avalanche Detectors (LGADs). The simulated data are compared against experimentally measured TPA-TCT results. Through this comparison, it is demonstrated that TCAD simulations can reproduce the TPA-TCT measurements, providing valuable insights into the TPA-TCT itself. Another significant outcome of this study is the successful simulation of the gain reduction mechanism, which can be observed in LGADs with increasing densities of excess charge carriers. This effect is demonstrated in an p-type LGAD with a thickness of approximately 286 µm. The results confirm the ability of TCAD to model the complex interaction between carrier dynamics and device gain., This project was performed within the framework of RD50 and DRD3 and has received funding from the European Union’s Horizon 2020 Research and Innovation programme under GA no 101004761 (AIDAinnova), the Wolfgang Gentner Program of the German Federal Ministry of Education and Research (grant no. 05E18CHA), and the CERN Knowledge Transfer Fund, through a grant awarded in 2017., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Impact of neutron irradiation on LGADs with a carbon-enriched shallow multiplication layer: Degradation of timing performance and gain

  • Navarrete Ramos, Efrén
  • Duarte Campderros, J.
  • Fernández-García, Marcos
  • Gómez, Gervasio
  • González, Javier
  • Hidalgo, Salvador
  • Jaramillo, R.
  • Martínez Ruiz del Arbol, P.
  • Moll, Michael
  • Quintana San Emeterio, Cristian
  • Sikdar, A. K.
  • Vila, Iván
  • Villegas, Jairo
In this radiation tolerance study, Low Gain Avalanche Detectors (LGADs) with a carbon-enriched broad and shallow multiplication layer were examined in comparison to identical non-carbonated LGADs. Manufactured at IMB-CNM, the sensors underwent neutron irradiation at the TRIGA reactor in Ljubljana, reaching a fluence of 1.5 × 10 15neqcm−2. The results revealed a smaller deactivation of boron and improved resistance to radiation in carbonated LGADs. The study demonstrated the potential benefits of carbon enrichment in mitigating radiation damage effects, particularly the acceptor removal mechanism, reducing the acceptor removal constant by more than a factor of two. Additionally, time resolution and collected charge degradation due to irradiation were observed, with carbonated samples exhibiting better radiation tolerance. A noise analysis focused on baseline noise and spurious pulses showed the presence of thermal-generated dark counts attributed to a too narrow distance between the gain layer end and the p-stop implant at the periphery of the pad for the characterized LGAD design; however, without significant impact of operation performance., This work was developed in the framework of the CERN RD50/DRD3 collaboration and has been funded by the Spanish Ministry of Science and Innovation (MCIN/AEI/10.13039/501100011033/) and by the European Union’s ERDF program “A way of making Europe”. Grant references: PID2020-113705RB-C31, PID2020-113705RB-C32 and PID2021-124660OB-C22. Also, it was supported by the following European funding programs: the European Union’s Horizon 2020 Research and Innovation (under Grant Agreement No. 101004761, AIDAInnova) and NextGenerationEU (PRTR-C17.I1). This work was also been developed in the framework of the “Ayudas Maria Zambrano para la atraccion de talento internacional”, co-funded by the Ministry Of University of Spain and the European Union NextGenerationEU, reference code: C21.I4.P1; under the framework of “Ayudas para contratos predoctorales para la formación de doctores 2019”, co-funded by the European Social Fund program “El FSE invierte en tu futuro” with grant reference: PRE2019-087514; and the Plan Complementario en el Área de Astrofísica y Física de Altas Energías, financed by Next Generation EU funds , including the Recovery and Resilience Mechanism (MRR), the Recovery, Transformation and Resilience Plan (PRTR) and the Autonomous Community of Cantabria., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Research data Set de datos (Dataset)

Replication data for nLGAD gain response to low-penetrating particles, Villegas, J., Torres, C., Manojlovic, M., Jimenez-Ramos, M. C., Moffat, N., Lopez, J. G., & Hidalgo, S. (2025, March). nLGAD gain response to low-penetrating particles [Data management plan]; versión 1

  • Villegas, Jairo
  • Torres Muñoz, Carmen
  • Manojlovic, Milos
  • Jiménez-Ramos, M. C
  • Moffat, Neil
  • García López, J.
  • Hidalgo, Salvador
There will not be restrictions to use the generated data after its publication, but external users will be asked to cite the source and/or the papers properly, and the redistribution of the data must be authorized by the researcher/supervisor. The identity of the person accessing the data will be ascertained with the following questionnaire, there won't be a need for a data access committee., Raw data obtained with nLGAD silicon detectors fabricated at IMB-CNM-CSIC for the paper: "nLGAD gain response to low-penetrating particles”, Spanish Ministry of Science, Innovation and Universities (MICIU/AEI/10.13039/501100011033/) and by the European Union’s ERDF program “A way of making Europe”. Grant references: CEX2023-001397-M, PID2020-113705RB-C32, PID2021-124660OB-C22, PDC2021-121718-C32 and PDC2023-145925-C32 European Union’s Horizon 2020 Research and Innovation. Grant Agreement No. 101004761 (AIDAInnova) NextGenerationEU, Spain (PRTR-C17.I1). CNA is also partially funded by the ASTRO21/1.1/1 (European Union- NextGenerationEU, the Ministry of Science, Innovation and Universities, Recovery Plan, Transformation and Resilience, Spain, the Department of University, Research and Innovation of the Junta de Andalucia and the University of Sevilla)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Evaluation of 3D sensors for fast timing applications

  • Diehl, Leena
  • Argyropoulos, Spyros
  • Ferrer, Oscar
  • Hauser, Marc
  • Jakobs, Karl
  • King, Montague
  • Lex, Fabian
  • Kramberger, Gregor
  • Parzefall, Ulrich
  • Pellegrini, Giulio
  • Schwemmbauer, Christina
  • Sperlich, Dennis
Novel collider experiments demand an increased performance of the silicon detectors used, such as withstanding up to 1×10<sup>17</sup>n<inf>eq</inf>/cm<sup>2</sup> in unprecedented pile-up conditions and providing time resolution around 10 ps. Currently, Low Gain Avalanche Diodes (LGADs) are the standard, achieving resolutions below 30 ps. However, their limited radiation hardness is an area of ongoing research. As an alternative to LGADs, 3D sensors are interesting due to their proven radiation hardness. In 3D sensors, where the columns are etched into the sensor from the top (junction columns) and the back (ohmic columns), the drift distances can be very short, the depletion voltage is low and the electric field can be high, resulting in fast and short signals. In this study, the time resolution of different 3D pixel and strip sensors is investigated with signals generated by electrons as well as an infra-red laser. TCT Timing measurements allow to study the position dependence of the time resolution, which is interesting for 3D sensors due to their complex electric field structure. Position-timing maps prove the direct correlation between time resolution and electric field. The time resolution of 3D sensors before and after irradiation is presented, showing that 3D sensors can reach the time resolution of standard 50μm LGADs, which is limited by Landau fluctuations. In addition, the results demonstrate that the radiation-induced performance degradation in 3Ds is less severe than in LGADs. Furthermore, initial results from a production run of dedicated fast 3D sensors which have recently been produced at CNM as a common RD50 project will be presented. Finally, the option of using fast 3D sensors as timing detectors in future collider experiments will be discussed., Funding text 1 This work has been funded by the Spanish Ministry of Science and Innovation (MCIN/AEI/10.13039/501100011033/) and by the European Union's ERDF program \u201CA way of making Europe\u201D. Grant references: PID2021-124660OB-C22. Also, it was funded by the European Union's Horizon 2020 Research and Innovation funding program, under Grant Agreement No. 101004761 (AIDAInnova) and partially by the RD50 CERN collaboration. Funding text 2 This work has been funded by the Spanish Ministry of Science and Innovation ( MCIN/AEI/10.13039/501100011033/ ) and by the European Union\u2019s ERDF program \u201CA way of making Europe\u201D . Grant references: PID2021-124660OB-C22 . Also, it was funded by the European Union\u2019s Horizon 2020 Research and Innovation funding program , under Grant Agreement No. 101004761 (AIDAInnova) and partially by the RD50 CERN collaboration ., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

First use of silicon carbide detectors with graphene-enhanced contacts for medical dosimetry

  • Lopez Paz, Ivan
  • Fleta, Celeste
  • Gomez, Faustino
  • González, Diego Miguel
  • Pellegrini, Giulio
Silicon Carbide (SiC) is a radiation hard wide bandgap semiconductor, which makes it an interesting alternative for radiation detector fabrication, with potential applications such as High Energy Physics, synchrotron and radiotherapy instrumentation. In addition, by reducing the amount of metal over the active area of said detectors (typically used for electrical connectivity with the implant of the pn-junction) unwanted effects from secondary interactions which can affect the accuracy of the measurement can be diminished, essential to meet the medical standards of precision. In this article, the use of epitaxially-grown graphene is explored as an alternative to metallic contacts with these prototypes. To this end, the first prototypes of SiC diodes with epitaxial graphene contacts were produced at IMB-CNM for radiation detection,along with reference devices. In order to characterise the feasibility of the technology in the medical application, the dose rate linearity of the SiC device with graphene was measured in a radiotherapy Linac in the dose rate range of 1-6 Gy/min. The response of the device was compared to that observed on devices with similar geometries reported elsewhere. To fully characterise the devices, the same exercise was repeated in a laboratory X-ray tube. Under the later set-up, the prototype is compared against a device with a fully metallised active region., This work has been supported by the IMB-CNM funded project PlACeD, and by the European Union\u2019s Horizon 2020 Research and Innovation funding program, under Grant Agreement No. 101004761 (AIDAInnova)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

The influence of pixel cell layout on the timing performance of 3D sensors

  • Lasaosa, Clara
  • Duarte Campderros, J.
  • Fernández-García, Marcos
  • Gómez, Gervasio
  • Vila, Iván
  • Hidalgo, Salvador
  • Pellegrini, Giulio
Trabajo presentado al 20th Anniversary Trento Workshop on Advanced Silicon Radiation Detectors (TREDI2025), celebrado del 4 al 6 de febrero de 2025 en Trento, Italy., Three-dimensional (3D) pixel sensors are a promising technology for implementing the 4D-tracking paradigm in high-radiation environments. Despite their advantages in radiation tolerance, 3D pixel sensors exhibit non-uniform electric and weighting fields that can degrade timing performance. This study explores the impact of pixel cell geometry on the timing characteristics of 3D columnar-electrode sensors fabricated by IMB-CNM, comparing square and hexagonal layouts. The sensors were characterized using the Two-Photon Absorption Transient Current Technique (TPA-TCT), providing high-resolution three-dimensional maps of the Time-of-Arrival (ToA) of charge carriers. Measurements at multiple depths and bias voltages reveal that the square geometry yields a more uniform temporal response compared to the hexagonal configuration. Additionally, a novel TPA-TCT-based method was introduced to determine the sensor jitter, relying on the analysis of the time difference between consecutive pulses in the TPA-TCT pulse train acquired under identical conditions. These findings underline the importance of pixel design optimization for future 4D-tracking detectors and confirm the TPA-TCT method as a powerful tool for detailed timing characterization., This work was partially supported by the AIDAInnova project, funded by the European Union’s Horizon 2020 Research and Innovation Programme under Grant Agreement No. 101004761. Additional funding was provided through Grants PID2023-148418NB-C41 and PID2023-148418NB-C42, financed by MCIN/AEI/10.13039/501100011033, and by the Complementary Plan in Astrophysics and HighEnergy Physics (CA25944), project C17.I02.P02.S01.S03 CSIC, supported by the Next Generation EU funds, RRF and PRTR mechanisms, and the Government of the Autonomous Community of Cantabria. This work has also received partial support from the Spanish Ministry of Science and Innovation through the Ramón y Cajal Programme [RYC2023-044327-I]., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Performance of irradiated TI-LGADs at 120 GeV SPS pion beams

  • Velkovska, Iskra
  • Duarte Campderros, J.
  • Fernández-García, Marcos
  • Gemme, C.
  • Gkougkousis, V.
  • Hennessy, A.
  • Hiti, B.
  • Kramberger, G.
  • López Ruiz, Rubén
  • Macchiolo, A.
  • Moffat, Neil
  • Navarrete Ramos, Efrén
  • Rezaei Mianroodi, P.
  • Robutti, E.
  • Senger, M.
  • Vila, Iván
20th Anniversary Trento Workshop on Advanced Silicon Radiation Detectors (TREDI2025): February 4-6 2025., Trench-isolated (TI) LGADs, developed at FBK, are pixelated LGAD implementations where pads are separated by physical trenches etched within the silicon substrate and filled with a dielectric. Developed as an alternative approach to implant-based inter-pad separation (JTEs), this technology promises a dramatic reduction in inefficient regions, mitigating fill factor issues inherent to small-pitch pixelated LGAD matrices. Through a dedicated 120 GeV SPS pion test beam campaign, the time resolution, efficiency, and inter-pad distance of carbon infused irradiated TI-LGADs is presented for Minimum Ionizing Particles (MIP). Fluences up to 1.5 × 1015 neq/cm2 are evaluated, for single trench implementations with varied trench width. The combined timing and tracking readout used in this study, integrating Region of Interest (ROI) triggering, sub-μm multi-object alignment, multi-channel waveform digitization and achieving a 5–7 μm spatial resolution through a MIMOSA26 telescope, are also reviewed. Preliminary results are discussed for temperatures of -25°C., The authors acknowledge financial support from the European Union’s Horizon 2020 Research and Innovation Programme under Grant Agreement No. 101004761. The authors also acknowledge the financial support from the Slovenian Research and Innovation Agency (ARIS P1-0135-27, J7-5 4419, PR-12843). This work was partially funded by Grant PID2023-148418NB-C41, funded by MCIN/AEI/10.13039/501100011033, and by the Complementary Plan in Astrophysics and HighEnergy Physics (CA25944), project C17.I02.P02.S01.S03 CSIC, funded by the Next Generation EU funds, RRF and PRTR funds, and the Autonomous Community of Cantabria. Jordi Duarte Campderros acknowledges grant RYC2023-044327-I funded by MICIU/AEI/10.13039/501100011033 and by ESF+., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Gain Response and Ion Beam-Induced Donor Removal in nLGAD Detector: Global Gain Quenching

  • Manojlovic, Milos
  • Crnjac, Andreo
  • Moffat, Neil
  • Villegas, Jairo
  • Pintilie, Ioana
  • Cabruja, Enric
  • Pellegrini, Giulio
  • Hidalgo, Salvador
This study investigates the response of n-type low-gain avalanche detectors (nLGADs) to local ion-beam irradiation with low-penetrating 1.285-MeV gallium ions, focusing on charge collection efficiency (CCE) and gain degradation. Using the transient current technique (TCT), we present charge collection maps before and after local irradiation. A 404-nm blue laser was used in postcharacterization, with no signal detected in the damaged zones after irradiation, suggesting significant charge trapping. The results reveal a pronounced vulnerability of nLGADs, with significant gain loss observed at fluences as low as 4 × 10<sup>9</sup> ions/cm<sup>2</sup>. This study confirms that a donor removal mechanism occurs at low fluences, and we hypothesize that this effect is linked to a vacancy-mediated mechanism. In addition, we report a global reduction in CCE, suggesting a long-range impact on electric field triggered by local defects. This phenomenon is referred to as the global gain quenching (GGQ). Simulations of the electric field provide further confirmation of GGQ’s occurrence., This work was supported in part by the Spanish Ministry of Science, Innovation and Universities, under Grant MICIU/AEI/10.13039/501100011033; in part by the European Regional Development Fund (ERDF) Program “A Way of Making Europe” under Grant CEX2023-001397-M, Grant PID2021-124660OB-C22, Grant DC2021-121718-C32, Grant PID2023-148418NB-C42, and Grant PDC2023-145925-C32; and in part by the European Union’s Horizon 2020 Research and Innovation Funding Program (AIDAInnova) under Grant Agreement 101004761 and Project IFA-CERN 07/2024., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Effects of neutron irradiation on LGADs with broad multiplication layer and varied carbon-enriched doses: A study on timing performance and gain deterioration

  • Navarrete Ramos, Efrén
  • Villegas, Jairo
  • Duarte Campderros, J.
  • Fernández-García, Marcos
  • Gómez-Carrera, A.
  • Gómez, Gervasio
  • González, Javier
  • Hidalgo, Salvador
  • Jaramillo, R.
  • Martínez Ruiz del Arbol, P.
  • Merlos Domingo, Ángel
  • Quintana San Emeterio, Cristian
  • Vila, Iván
Data will be made available on request., In this radiation tolerance study, Low Gain Avalanche Detectors (LGADs) with a carbon-enriched broad and shallow multiplication layer were examined in comparison to identical non-carbonated LGADs. Manufactured at IMB-CNM, the sensors underwent neutron irradiation at the TRIGRA reactor in Ljubljana, reaching a fluence of 2.5 × 1015 neq cm-2. The results revealed a smaller deactivation of Boron and improved resistance to radiation in carbonated LGADs. The study demonstrated the potential benefits of carbon enrichment in mitigating radiation damage effects, particularly the acceptor removal mechanism, reducing the acceptor removal constant by more than a factor of two. Additionally, time resolution and collected charge degradation due to irradiation were observed, with carbonated samples exhibiting better radiation tolerance. A noise analysis focused on baseline noise and thermally generated pulses showed the presence of spurious thermal-generated pulses attributed to a excessive small distance between the gain layer end and the p-stop implant at the periphery of the pad for the characterized LGAD design; however, the operation performance of the devices was unaffected., This work was developed in the framework of the CERN DRD3 collaboration and has been funded by the Spanish Ministry of Science and Innovation (MICIU/AEI/10.13039/501100011033/) and by the European Union’s ERDF program “A way of making Europe”. Grant references: CEX2023-001397-M, PID2023-148418NB-C41, PID2023-148418NB-C42, PDC2023-145925-C31 and PDC2023-145925-C32. Also, it was supported by the European Union’s Horizon 2020 Research and Innovation funding program (Grant Agreement No. 101004761, AIDAInnova)., This work has also been supported by the European Union NextGenerationEU/PRTR project C17.I02.P02 - SGI_GICS_Nuevas actuaciones en grandes infraestructuras de investigación europeas e internacionales, the Complementary Plan in Astrophysics and High-Energy Physics (CA25944), project C17.I02.P02.S01.S03 CSIC CERN, funded by the Next Generation EU funds, RRF and PRTR funds, and the Autonomous Community of Cantabria., This work has been developed in the framework of the Grant RyC-2023-044327-I funded by the Spanish Ministry of Science, Innovation and Universities (MICIU/AEI/10.13039/501100011033) and by FSE+, and co-funded by the European Social Fund program “El FSE invierte en tu futuro” with grant reference: PRE2019-087514., With funding from the Spanish government through the "Severo Ochoa Centre of Excellence" accreditation (CEX2023-001397-M)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Design, prototyping, and test of a Highly Compact and Granular Electromagnetic Calorimeter for the LUXE experiment

  • Almanza Soto, M.
Melissa Almanza Soto on behalf of the LUXE ECAL-P Group, The LUXE experiment will investigate the strong-field QED regime by using the interactions of high-energy electrons from the European XFEL in a powerful laser field. It will measure the production of electron–positron pairs as a function of the laser field strength, up to the non-perturbative non-linear regime. LUXE foresees a positron detection system consisting of a tracker and a granular and unprecedentedly compact silicon-tungsten electromagnetic sandwich calorimeter (ECAL-P). The ECAL-P has been designed to cope with the wide range of the expected number of positrons per bunch crossing. In addition, the energy distribution of the positrons has to be measured on top of a widely spread low-energy background. The ECAL-P is composed of tungsten absorber plates interspersed with thin sensor planes, consisting of silicon pad sensors, flexible Kapton printed circuit planes, and carbon fiber support. The sensor planes are less than 1mm thick and will be read using dedicated front-end ASICs in 130nm technology (FLAXE) and FPGAs for data pre-processing. GaAs sensor planes with integrated readout strips are also being considered as an alternative to silicon. Prototypes of individual sensor planes have been tested in a 5 GeV electron beam. A full compact calorimeter tower of up to 90×90×600 mm<sup>3</sup> (15X<inf>0</inf>) will be produced and tested in an electron beam. The design challenges, sensor characterization, prototyping, integration, commissioning, and the available results from a beam test in 2022 are discussed., This research was supported by the European Union’s Horizon 2020 Research and Innovation programme 3309 under GA no. 101004761, the German-Israeli Foundation under grant no. I/1492/303.7/2019, the Israeli PAZY Foundation (ID 318), and the Generalitat Valenciana (Spain) under the grant number CIDEGENT/2020/21. IFIC members also acknowledge the financial support from the MCIN with funding from the European Union NextGenerationEU and Generalitat Valenciana in the call Programa de Planes Complementarios de I+D+i (PRTR 2022) through the project with reference ASFAE ; the Program Programa Estatal para Desarrollar, Atraer y Retener Talento PEICTI 2021–2023 through the project with reference CNS ; the Spanish MCIU/ AEI/10.13039/501100011033 and European Union/FEDER via the grant PID2021-122134NB-C21 and the Generalitat Valenciana (GV) via the Excellence Grant CIPROM/2021/073., Support was given by the National Science Centre, Poland, under grant no. 2021/43/B/ST2/01107, and partially support by the Romanian Ministry of Research, Innovation and Digitalization under Romanian National Core Program LAPLAS VII contract no. 30N/2023 and by the Institute of Atomic Physics through the CERN-RO Project No. 005/2024. The measurements leading to these results have been performed at the Test Beam Facility at DESY Hamburg (Germany), a member of the Helmholtz Association (HGF)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Achieving near 100% Fill factor for small pixel LGADs: Study of First Trench Isolated LGADs fabricated at Micron Semiconductor Ltd

  • Zareef, Fasih
  • Moffat, Neil
  • Bates, Richard
  • Maneuski, Dzmitry
  • Han, Ruirui
  • Bullough, Mark
  • Williams, Mark
  • Obłąkowska-Mucha, Agnieszka
  • Szumlak, Tomasz
This paper presents the development and characterization of Trench-Isolated LGADs (TI-LGADs). This architecture replaces traditional junction termination structures with narrow trenches to minimize inter-pixel distance (IPD) and enhance fill factor (FF). Fabricated by Micron Semiconductor Ltd., TI-LGADs demonstrate excellent electrical isolation, low leakage currents, and no premature breakdown up to 1000 V. Transient Current Technique (TCT) measurements and TCAD simulations reveal an IPD of less than 5 μm, a significant improvement over standard LGADs which have an IPD of ≈ 50 μm. The devices exhibit a gain of 2-3, consistent with simulations, and maintain good pixel isolation with minimal crosstalk. These results highlight the potential of TI-LGADs for fine-segmented, high-resolution 4D tracking applications, paving the way for future optimizations and radiation-hard designs., This work has received funding from the European Union’s Horizon 2020 Research and Innovation programme under Grant Agreement No. 101004761. This research has received support from Excellence Initiative– Research University AGH IDUB 6275, Polish National Science Center under agreement no. NCN 2023/49/N/ST2/02314 and UMO-2023/51/B/ST2/02313. This research has received funding from the STFC Opportunities grant under agreement no. ST/T002751/1. This research has received funding from the Royal Society., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Investigating the impact of the diode edge geometry on the effective active area of silicon sensors using AREA-X

  • Poley, Luise
  • Dyckes, Ian
  • Fernández-Tejero, Javier
  • Fleta, Celeste
  • Sperlich, Dennis
  • Ullán, Miguel
10 pages, 7 figures, published in Journal of Instrumentation, Sensors for particle tracking detectors are required to provide a maximum active area in addition to fulfilling performance criteria concerning radiation hardness, charge collection and operating conditions (e.g. leakage current, depletion voltage and breakdown voltage). While the requirement for optimised coverage within the tracking detector necessitates a slim sensor edge between active region and physical sensor edge, wider edge regions were found to be beneficial for the sensor performance during an early prototyping phase. In order to study the impact of differently sized edge regions, test structures were used to compare their individual active regions. Measurements of each diode were performed using a micro-focused X-ray beam to map its respective active area. This paper presents measurements of these test structures using AREA-X showing that the active area of a silicon particle tracking sensor does not only depend on the size of its bias ring, but also the size and configuration of its edge structure., This work has received funding from the European Union’s Horizon 2020 Research and Innovation programme under Grant Agreement No. 101004761. This research has received support from Excellence Initiative– Research University AGH IDUB 6275, Polish National Science Center under agreement no. NCN 2023/49/N/ST2/02314 and UMO-2023/51/B/ST2/02313. This research has received funding from the STFC Opportunities grant under agreement no. ST/T002751/1. This research has received funding from the Royal Society., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

A ping-pong self-sustaining avalanche in TI-LGAD sensors

  • Laštovička-Medin, Gordana
  • Manojlović, Miloš
  • Backović, Vanja
  • Mrkić, Danijela
  • Baletić, Vuk
  • Kramberger, Gregor
  • Kroll, Jirí
  • Laštovička, Tomaš
  • Andreasson, Jakob
  • Rebarz, Mateusz
This work is a continuation of our previous research on trench-isolated LGAD sensors that reveal exceptionally large, long-duration signals without external stimuli, so called “ghost signals”. Here, we extend the LGAD study to corresponding PIN sensors with the same inter-pixel isolation structure (double trench). In addition to previously studied sensors, we investigated new double-trenched LGADs where the gain layer was co-implanted with carbon. All studied LGADs exhibited spontaneous ghost signals above a certain threshold value of applied bias, whereas it was not observed in corresponding PINs. On the other hand, strong and broad signal was generated in the inter-pixel region of PINs using fs-laser illumination under specific parameters. We will discuss the hypotheses for the mechanism behind these signals., The authors acknowledge the use of the ELI Beamlines Facility, Extreme Light Infrastructure ERIC. The authors acknowledge also the AIDAinnova project (Advancement and Innovation for Detectors at Accelerators); this research has received funding from the European Union\u2019s Horizon 2020 Research and Innovation Programme under Grant Agreement No 101004761. The authors acknowledge also the project \u201CTAIDA: Advancement and Innovation for Detectors at Accelerators\u201D (Contract No. 0402-082/23-1740/5, Ministry of Education, Science and Innovation in Montenegro). The authors are grateful to Matteo Centis Vignali from Fondazione Bruno Kessler (FBK) and Vagelis Gkougkousis from the University of Zurich for useful discussions., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

OBELIX: A monolithic pixel sensor with triggered readout for the Belle II upgrade

  • Babeluk, M.
  • Auguste, D.
  • Barbero, M.
  • Barrillon, P.
  • Baudot, J.
  • Bergauer, T.
  • Bernlochner, F.
  • Bertolone, G.
  • Bespin, C.
  • Bettarini, S.
  • Bevan, A.
  • Bona, M.
  • Bonis, J.
  • Bosi, F.
  • Boudagga, R.
  • Breugnon, P.
  • Buch, Y.
  • Casarosa, G.
  • Corona, L.
  • Dingfelder, J.
  • Dorokhov, A.
  • Dujany, G.
  • Federici, L.
  • Fernandez Prieto, A.
  • Finck, C.
  • Forti, F.
  • Fougeron, D.
  • Frey, A.
  • Gabrielli, A.
  • Gaioni, L.
  • Gallas Torreira, A.
  • Gao, X.
  • Giroletti, S.
  • Gong, J.
  • Hara, K.
  • Higuchi, T.
  • Himmi, A.
  • Howgill, D.
  • Hu-Guo, C.
  • Irmler, C.
  • Jeans, D.
  • Kaliyar, A.B.
  • Karagounis, M.
  • Kishishita, T.
  • Krüger, H.
  • Kumar, A.
  • Lacasta Llácer, Carlos
  • Mariñas Pardo, Carlos
  • Massa, M.
  • Massaccesi, L.
  • Maushart, M.
  • Mazorra de Cos, J.
  • Minuti, M.
  • Moggi, A.
  • Molina-Bueno, L.
  • Mondal, S.
  • Morel, F.
  • Nakamura, K.R.
  • Okazaki, Y.
  • Onuki, Y.
  • Pangaud, P.
  • Peinaud, Y.
  • Pham, H.
  • Pilsl, B.
  • Ratti, L.
  • Re, V.
  • Riceputi, E.
  • Ripp-Baudot, I.
  • Rizzo, G.
  • Schall, L.
  • Schwanda, C.
  • Schwenker, B.
  • Schwickardi, M.
  • Sefri, R.
  • Serrano, J.
  • Song, W.
  • Stavroulakis, P.
  • Traversi, G.
  • Valin, I.
  • Vobbilisetti, V.
  • Vogt, M.
  • Wang, S.
  • Winter, M.
  • Xu, D.
The Upgrade of the Belle II vertex detector (VTX) at the SuperKEKB accelerator in Japan is foreseen to improve tracking performance at the expected high beam backgrounds at target luminosity of 6 × 1035 cm-2s-1. The OBELIX-1 chip is specifically developed for this purpose and used as sensor on all VTX layers. OBELIX-1 is a depleted monolithic active pixel sensor in 180 nm technology. The pixel matrix is inherited from TJ-Monopix2, but the periphery of the chip is entirely reworked. A newly designed 2-stage pixel memory matches Belle II trigger requirements. OBELIX-1 includes LDO regulators and a precision timing module with less than 3ns resolution. Furthermore, the chip can also contribute to the Belle II trigger system with low latency, low granularity real-time streaming of pixel data in parallel to regular operation. Details of the inner working of the trigger memory are presented, as well as performance simulations to validate the requirements for the VTX Upgrade. The trigger memory has been studied in simulation using realistic scenarios, including Landau distributed charge and clustering to evaluate performance. In order to allow post-production testing, an additional module is presented. This allows the injection of pseudo-random data early in the processing chain, and replaces the need for industry standard scan-chains. It can be used stand-alone or during analog charge injection, in order to reach the full trigger memory during testing. © 2025 The Authors, This work has received the support from the European Union’s Horizon 2020 Research and Innovation programme under Grant Agreements no 101004761 (AIDAinnova), Multilateral Scientific and Technological Cooperation in the Danube Region (MULT 03/23), Horizon 2020 ERC-Consolidator Grant No. 819127, TY-FJPPN (Toshiko Yuasa-France Japan Particle Physics Network), the MCIU with funding from the European Union NextGenerationEU (PRTR-C17.I01) and Generalitat Valenciana (GVANEXT), Spain , Project ASFAE/2022/016, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

On the determination of the interaction time of GeV neutrinos in large argon gas TPCs

  • Saá-Hernández, A.
  • González-Díaz, D.
  • Martín-Albo, Justo
  • Tuzi, Mirald
  • Amedo, P.
  • Baldonedo, J.
  • Benítez, C.
  • Bounasser, S.
  • Casarejos, E.
  • Collazo, J.
  • Fernández-Prieto, A.
  • Fernández-Posada, D.J.
  • Hafeji, R.
  • Leardini, S.
  • Rodas-Rodríguez, D.
  • Saborido, A.L.
  • Segade, A.
  • Slater, A.
Next-generation megawatt-scale neutrino beams open the way to studying neutrino-nucleus scattering using gaseous targets for the first time. This represents an opportunity to improve the knowledge of neutrino cross sections in the energy region between hundreds of MeV and a few GeV, of interest for the upcoming generation of long-baseline neutrino oscillation experiments. The challenge is to accurately track and (especially) time the particles produced in neutrino interactions in large and seamless volumes down to few-MeV energies. We propose to accomplish this through an optically-read time projection chamber (TPC) filled with high-pressure argon and equipped with both tracking and timing functions. In this work, we present a detailed study of the time-tagging capabilities of such a device, based on end-to-end optical simulations that include the effect of photon propagation, photosensor response, dark count rate and pulse reconstruction. We show that the neutrino interaction time can be reconstructed from the primary scintillation signal with a precision in the range of 1–2.5 ns (σ) for point-like deposits with energies down to 5 MeV. A similar response is observed for minimum-ionizing particle tracks extending over lengths of a few meters. A discussion on previous limitations towards such a detection technology, and how they can be realistically overcome in the near future thanks to recent developments in the field, is presented. The performance demonstrated in our analysis seems to be well within reach of next-generation neutrino-oscillation experiments, through the instrumentation of the proposed TPC with conventional reflective materials and a silicon photomultiplier array behind a transparent cathode. © The Author(s) 2025., This work was supported by the European Union’s Horizon 2020 Research and Innovation programme under grant agreement No. 101004761; the Xunta de Galicia (Centro Singular de Investigación de Galicia accreditation 2019-2022); the Generalitat Valenciana (grant CIDEGENT/2019/049); the “María de Maeztu” Units of Excellence program (MDM-2016-0692); and the Spanish Ministry of Science and Innovation (PID2021-125028OB-C21). DGD was supported by the Ramón y Cajal program under contract RYC-2015-18820. JM-A acknowledges support from the Ramón y Cajal program (grant RYC2021-033265-I), funded by the Spanish MCIN/AEI/10.13039/501100011033 and by the EU (NextGenerationEU/PRTR)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

The DMAPS upgrade of the Belle II Vertex Detector

  • Rizzo, G.
  • Auguste, D.
  • Babeluk, M.
  • Barbero, M.
  • Barrillon, P.
  • Baudot, J.
  • Bergauer, T.
  • Bernlochner, F.
  • Bertolone, G.
  • Bespin, C.
  • Bettarini, S.
  • Bevan, A.
  • Bona, M.
  • Bonis, J.
  • Bosi, F.
  • Boudagga, R.
  • Breugnon, P.
  • Buch, Y.
  • Casarosa, G.
  • Corona, L.
  • Dingfelder, J.
  • Dorokhov, A.
  • Dujany, G.
  • Finck, C.
  • Forti, F.
  • Frey, A.
  • Fougeron, D.
  • Gabrielli, A.
  • Gaioni, L.
  • Giroletti, S.
  • Hara, K.
  • Higuchi, T.
  • Himmi, A.
  • Howgill, D.
  • Irmler, C.
  • Jeans, D.
  • Kaliyar, A.B.
  • Karagounis, M.
  • Kishishita, T.
  • Krüger, H.
  • Kumar, A.
  • Lacasta Llácer, Carlos
  • Mariñas Pardo, Carlos
  • Massa, M.
  • Massaccesi, L.
  • Mazorra de Cos, J.
  • Minuti, M.
  • Moggi, A.
  • Mondal, S.
  • Morel, F.
  • Nakamura, K.R.
  • Okazaki, Y.
  • Onuki, Y.
  • Pangaud, P.
  • Peinaud, Y.
  • Pham, H.
  • Pilsl, B.
  • Ratti, L.
  • Re, V.
  • Riceputi, E.
  • Ripp-Baudot, I.
  • Schall, L.
  • Schwanda, C.
  • Schwenker, B.
  • Schwickardi, M.
  • Sefri, R.
  • Serrano, J.
  • Stavroulakis, P.
  • Traversi, G.
  • Valin, I.
  • Vobbilisetti, V.
  • Vogt, M.
  • Wang, S.
  • Winter, M.
  • Xu, D.
The SuperKEKB collider will undergo a major upgrade at the end of the decade to reach the target luminosity of 6 × 1035 cm-2s-1, offering the opportunity to install a new fully pixelated vertex detector (VTX) for the Belle II experiment, based on depleted-MAPS sensors. The VTX will be more granular and robust against the expected higher level of machine background and more performant in terms of standalone track finding efficiency. The VTX baseline design includes five depleted-MAPS sensor layers, spanning radii from 14 mm to 140 mm, with a material budget ranging from 0.2% to 0.8% X/X0 per layer. All layers will be equipped with the same OBELIX sensor, designed in the TowerJazz 180 nm technology, with the pixel matrix derived from the TJ-Monopix2 sensor originally developed for the ATLAS experiment. The paper will describe the proposed VTX structure and review all project aspects: tests of the TJ-Monopix2 sensor, OBELIX-1 design status, ladder prototype fabrication and tests. © 2024, AIDAinnova (Horizon 2020 Grant No. 101004761), Multilateral Scientific and Technological Cooperation in the Danube Region (MULT 03/23). Horizon 2020 ERC-Consolidator Grant No. 819127. TY-FJPPN (Toshiko Yuasa-France Japan Particle Physics Network). These results received support from the MCIU with funding from the European Union NextGenerationEU (PRTR-C17.I01) and Generalitat Valenciana (GVANEXT) . Project ASFAE/2022/016., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

A graphene-on-silicon photodetector for low penetrating radiation

  • Moffat, Neil
  • Soto-Oton, J. A.
  • Rius, Gemma
  • Cabruja Casas, Enric
  • Pellegrini, Giulio
We introduce an innovative graphene-on-silicon photodiode designed for low penetrating radiation. Its standout feature lies in its remarkably-thin dead layer in the entrance window, setting it apart from existing photodetectors. Conventional photodetectors suffer from sensitivity limitations in the low wavelength or energy, respectively, for light or particles, due to their shallow penetration depth. Most conventional photodiodes employ a junction implant which suffers from recombination of low-penetrating photons/particles within the dead layer. Instead, we utilise the nearly transparent properties of single-layer graphene to create a depletion layer that minimises the dead layer. We combine a single junction ring (highly doped [Formula: see text] bias ring) with single-layer graphene. The graphene acts as a field plate, extended over the junction ring and covering the entire entrance window (5×5 [Formula: see text] active area), while being electrically isolated by an ultrathin, high K dielectric layer. In operation, the photodiode undergoes depletion upon applying a reverse bias as expected, which primarily occurs within the region beneath the field plate. We conducted Transient Current Technique measurements as the best method to assess the charge collection uniformity of the device. Remarkably, the results reveal a consistent total 100% uniformity across the entire detector area. Nevertheless, while the collection time is position-dependent, increasing as the laser incidence point moves farther away from the bias ring, responsivity measurements show excellent response in both the deep ultra violet and vacuum ultra violet regions with ≥ 100% external quantum efficiency at wavelengths below 150 nm., Open Access funding provided thanks to the CRUE-CSIC agreement with Springer Nature. This work has been financed by the Spanish Ministry of Science and Innovation (MICIN) through the Particle Physics National Program RTI2018-094906-B-C22. This work was also supported by Ayudas Ramon y Cajal, Grant Ref. RYC-2016-21412 and this work has been financed by the Spanish Ministry of Science and Innovation (MCIN/AEI/10.13039/501100011033/) Project references: SPID202000X118404SV1, PID2020-118275RB-C22, PID2021-124660OB-C22, PDC2023-145815-C22. This work has received funding by the European Union’s Horizon 2020 Research and Innovation programme under Grant Agreement No. 101004761. All the manufacturing was performed at the IMB-CNM clean room facilities, member of the Spanish ICTS Network MICRONANOFABS partially supported by MICIN and FEDER funds. The authors thank the Experimental Neutrino Group at IFIC (CSIC–UV), Spain, for providing access to their optical laboratory and equipment, acquired with the support of the Ministerio de Ciencia, Innovación y Universidades (MICIN) and funding from the European Union NextGenerationEU (PRTR-C17.I01), as well as the Generalitat Valenciana, Project (IFIC-NuLight), ASFAE/2022/029., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Tracking and timing measurements on irradiated TI-LGADs

  • Gómez-Carrera, A.
  • Diehl, L.
  • Duarte Campderros, J.
  • Fernández-García, Marcos
  • Gkougkousis, V.
  • Hiti, B.
  • Kramberger, G.
  • Macchiolo, A.
  • Padniuk, Y.
  • Puklavec, M.
  • Torres Muñoz, Carmen
  • Velkovska, I.
  • Vila, Iván
21st Trento Workshop on Advanced Silicon Radiation Detectors (TREDI 2026), Trench-isolated (TI) LGADs, developed at FBK, are pixelated LGAD implementations where pads are separated by physical trenches etched within the silicon substrate and filled with a dielectric material. Developed as a solution to the LGAD fill factor problem, this technology provides a path towards 4D tracking with reduced inefficiencies in the interpad regions. Through a dedicated 120 GeV SPS pion test beam campaign, the time resolution, efficiency, and inter-pad distance of carbon infused irradiated TI-LGADs is presented. Fluences up to 2.5 × 1015 neqcm-2 are evaluated, for single trench implementations with varied trench width at a temperature of -25°C. The results show an interpad distance degradation with the irradiation of the detector and an optimal time resolution between 35 ps and 45 ps for all studied devices., This work was supported by the Programa de Ayudas Predoctorales Concepción Arenal of the University of Cantabria, co-funded by the Government of Cantabria. It was also co-funded by the Complementary Plan in Astrophysics and High-Energy Physics (CA25944), project C17.I02.P02.S01.S03 CSIC CERN, supported by the Next Generation EU funds, RRF and PRTR mechanisms, and the Government of the Autonomous Community of Cantabria. This work was developed within the framework of the CERN DRD3 collaboration and was funded by the Spanish Ministry of Science, Innovation and Universities (MICIU/AEI/10.13039/501100011033) and by the European Regional Development Fund (ERDF) program “A way of making Europe” under Grant PID2023-148418NB-C41. Additional support was provided by the European Union’s Horizon 2020 Research and Innovation Programme through AIDAinnova (Grant Agreement No. 101004761). This work also received support from the European Union NextGenerationEU/PRTR project C17.I02.P02 – SGI_GICS_Nuevas actuaciones en grandes infraestructuras de investigación europeas e internacionales, and from Grant RyC-2023-044327-I funded by MICIU/AEI/10.13039/501100011033 and by FSE+, co-funded by the European Social Fund program “El FSE invierte en tu futuro”, as well as grant PRE2019-087514. This work was supported by Grant CSN2024-154303 funded by MICIU/AEI/10.13039/501100011033., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Impact of radiation damage to the performance of depleted monolithic active pixel sensors for Belle II vertex detector upgrade

  • Wang, S.
  • Babeluk, M.
  • Bergauer, T.
  • Friedl, M.
  • Irmler, C.
  • Pilsl, B.
  • Schwanda, C.
  • Gaioni, L.
  • Re, V.
  • Riceputi, E.
  • Traversi, G.
  • Giroletti, S.
  • Ratti, L.
  • Benfratello, G.F.
  • Bettarini, S.
  • Bosi, F.
  • Casarosa, G.
  • Corona, L.
  • Forti, F.
  • Gabrielli, A.
  • Massa, M.
  • Massaccesi, L.
  • Minuti, M.
  • Moggi, A.
  • Mondal, S.
  • Rizzo, G.
  • Taffara, A.
  • Vobbilisetti, V.
  • Barbero, M.
  • Barrillon, P.
  • Boudagga, R.
  • Breugnon, P.
  • Fougeron, D.
  • Pangaud, P.
  • Serrano, J.
  • Xu, D.
  • Auguste, D.
  • Bonis, J.
  • Peinaud, Y.
  • Winter, M.
  • Baudot, J.
  • Bertolone, G.
  • Dorokhov, A.
  • Dujany, G.
  • Federici, L.
  • Finck, C.
  • Himmi, A.
  • Hu-Guo, C.
  • Kumar, A.
  • Maushart, M.
  • Morel, F.
  • Pham, H.
  • Ripp-Baudot, I.
  • Sefri, R.
  • Stavroulakis, P.
  • Valin, I.
  • Bernlochner, F.
  • Bespin, C.
  • Dingfelder, J.
  • Krüger, H.
  • Schall, L.
  • Vogt, M.
  • Karagounis, M.
  • Buch, Y.
  • Frey, A.
  • Schwenker, B.
  • Schwickardi, M.
  • Hara, T.
  • Jeans, D.
  • Kishishita, T.
  • Nakamura, K.R.
  • Okazaki, Y.
  • Higuchi, T.
  • Onuki, Y.
  • Lacasta Llácer, Carlos
  • Mariñas Pardo, Carlos
  • Mazorra de Cos, J.
  • Molina Bueno, Laura
  • Bevan, A.
  • Bona, M.
  • Howgill, D.
  • Song, W.
  • Gong, J.
  • Gao, X.
  • Prieto, A.F.
  • Torreira, A.G.
The Belle II experiment running at the SuperKEKB e+e− collider will be upgraded during its Long Shutdown 2 (LS2), in order to reach its target instantaneous luminosity of 6×1035cm−2s−1. A fully pixelated vertex detector, VTX, is proposed as the upgrade for the Belle II experiment to cope with higher hit rates, increased background and radiation level at the target luminosity. The VTX utilizes CMOS Depleted Monolithic Active Pixel Sensors (DMAPS), OBELIX sensors, developed based on the TJ-Monopix2 prototype. In order to ensure reliable performance after irradiation during long-term operation, the impact of radiation damage on a detection performance of TJ-Monopix2 has been studied, including its dependence on operating temperature, which is a key parameter for defining the cooling requirements and safe operating limits. After irradiation to the target accumulated NIEL fluence, the DC front-end of TJ-Monopix2 is confirmed to maintain a detection efficiency of >99% at the NTC temperature of 40°C (chip temperature of about 47°C) with the detection threshold of approximately 350e−., This work has received the support from the European Union’s Horizon 2020 Research and Innovation programme under Grant Agreements no 101004761 (AIDAinnova), Multilateral Scientific and Technological Cooperation in the Danube Region (MULT 03/23), Horizon 2020 ERC-Consolidator Grant No. 819127, TY-FJPPN (Toshiko Yuasa-France Japan Particle Physics Network), the MCIU with funding from the European Union NextGenerationEU (PRTR-C17.I01) and Generalitat Valenciana (GVANEXT) , Project ASFAE/2022/016. The measurements leading to these results have been performed at the Test Beam Facility at DESY Hamburg (Germany), a member of the Helmholtz Association (HGF), and received support from the CYRCé member of the France Life Imaging network (ANR-11-INBS-0006)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Development for the Belle II vertex detector upgrade with depleted monolithic active pixel sensors

  • Onuki, Y.
  • Babeluk, M.
  • Bergauer, T.
  • Friedl, M.
  • Irmler, C.
  • Pilsl, B.
  • Russo, R.
  • Schwanda, C.
  • Gaioni, L.
  • Re, V.
  • Riceputi, E.
  • Traversi, G.
  • Giroletti, S.
  • Ratti, L.
  • Benfratello, G. F.
  • Bettarini, S.
  • Bosi, F.
  • Casarosa, G.
  • Corona, L.
  • Forti, F.
  • Gabrielli, A.
  • Massa, M.
  • Massaccesi, L.
  • Minuti, M.
  • Moggi, A.
  • Mondal, S.
  • Rizzo, G.
  • Rovini, M.
  • Taffara, A.
  • Barbero, M.
  • Barrillon, P.
  • Boudagga, R.
  • Breugnon, P.
  • Fougeron, D.
  • Pangaud, P.
  • Serrano, J.
  • Vobbilisetti, V.
  • Xu, D.
  • Auguste, D.
  • Bonis, J.
  • Peinaud, Y.
  • Winter, M.
  • Baudot, J.
  • Bertolone, G.
  • Dorokhov, A.
  • Dujany, G.
  • Federici, L.
  • Finck, C.
  • Himmi, A.
  • Hu-Guo, C.
  • Kumar, A.
  • Maushart, M.
  • Morel, F.
  • Pham, H.
  • Ripp-Baudot, I.
  • Sefri, R.
  • Stavroulakis, P.
  • Valin, I.
  • Bernlochner, F.
  • Bespin, C.
  • Dingfelder, J.
  • Kishishita, T.
  • Krüger, H.
  • Schall, L.
  • Vogt, M.
  • Karagounis, M.
  • Buch, Y.
  • Frey, A.
  • Schwenker, B.
  • Schwickardi, M.
  • Hara, K.
  • Jeans, D.
  • Nakamura, K. R.
  • Okazaki, Y.
  • Higuchi, T.
  • Wang, S.
  • Lacasta Llácer, Carlos
  • Mariñas Pardo, Carlos
  • Mazorra de Cos, J.
  • Molina Bueno, Laura
  • Bevan, A.
  • Bona, M.
  • Howgill, D.
  • Song, W.
  • Gong, J.
  • Gao, X.
  • Fernandez Prieto, A.
  • Gallas Torreira, A.
The vertex detector upgrade project for the Belle II experiment, based on CMOS depleted monolithic active pixel sensor technology, is planned to be carried out in conjunction with the major modification of the interaction region of the SuperKEKB collider during Long Shutdown 2 (2032–2034). The MAPS sensor, named OBELIX currently under development, is derived from the successor to TJ-Monopix2, with modifications implemented to ensure compatibility with the Belle II trigger system. The new vertex detector consists of two layers of four self-supported consecutive OBELIX sensors, and three layers of discrete OBELIX sensors mounted on mechanical support structures with readout flex circuits attached to the sensors. The detector is arranged cylindrically around the beam pipe at radii ranging from 14 mm to 140 mm. The minimization of the material budget is required in order to enhance physics performance. We present an overview of the project and its latest developments, with particular emphasis on the development of low-material-budget flex circuits employing aluminum conductors., This work has received the support from the European Union’s Horizon 2020 Research and Innovation programme under Grant Agreements no. 101004761 (AIDAinnova), Multilateral Scientific and Technological Cooperation in the Danube Region (MULT 03/23), Horizon 2020 ERC-Consolidator Grant No. 819127, TY-FJPPN (Toshiko Yuasa-France Japan Particle Physics Network), the MCIU with funding from the European Union NextGenerationEU (PRTR-C17.I01), Generalitat Valenciana (GVANEXT), Project ASFAE/2022/016, JSR–UTokyo Collaboration Hub CURIE, and The Precise Measurement Technology Promotion Foundation (PMTP-F)., Peer reviewed