Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 6
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

nLGAD gain response to low-penetrating particles

  • Villegas, Jairo
  • Torres Muñoz, Carmen
  • Manojlovic, Milos
  • Jiménez-Ramos, M. C.
  • Moffat, Neil
  • García López, J.
  • Hidalgo, Salvador
Detecting low-penetrating particles is fundamental for a wide range of applications in the fields of industry, medicine, and pure research. The Low Gain Avalanche Detector built on n-type substrates (nLGAD) is considered a good candidate for that, as it showed to have the potential to detect such particles with high sensitivity while avoiding the high noise levels associated with a traditional avalanche photodetector. An overview of the electrical characterization of the latest nLGAD batch fabricated at the Institute of Microelectronics of Barcelona is presented in this work. Additionally, gain response measurements for light with varying penetration depths in silicon and 600 keV protons are also presented. The results confirm the aforementioned potential of nLGADs to detect low-penetrating particles in silicon. Additionally, it was observed that the gain response of the devices is not only dependent on the penetration depth of the studied particles, but also on the nature and flux of the source., This work has been funded by the Spanish Ministry of Science, Innovation and Universities (MICIU/AEI/10.13039/501100011033/) and by the European Union’s ERDF program “A way of making Europe”. Grant references: PID2020-113705RB-C32, PID2021-124660OB-C22, PDC2021-121718-C32 and PDC2023-145925-C32. Also, it was supported by the following European funding programs: European Union’s Horizon 2020 Research and Innovation (under Grant Agreement No. 101004761, AIDAInnova) and NextGenerationEU (PRTR-C17.I1). M. Carmen Jimenez-Ramos acknowledges the support of this work through a VI PPIT-US contract. This investigation has also been partially financed by the project ref. ASTRO21/1.1/1 with financing from the European Union- NextGenerationEU, the Ministry of Science, Innovation and Universities, Recovery Plan, Transformation and Resilience, Spain, the Department of University, Research and Innovation of the Junta de Andalucia and the University of Sevilla, Spain ., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Research data Set de datos (Dataset)

Replication data for nLGAD gain response to low-penetrating particles, Villegas, J., Torres, C., Manojlovic, M., Jimenez-Ramos, M. C., Moffat, N., Lopez, J. G., & Hidalgo, S. (2025, March). nLGAD gain response to low-penetrating particles [Data management plan]; versión 1

  • Villegas, Jairo
  • Torres Muñoz, Carmen
  • Manojlovic, Milos
  • Jiménez-Ramos, M. C
  • Moffat, Neil
  • García López, J.
  • Hidalgo, Salvador
There will not be restrictions to use the generated data after its publication, but external users will be asked to cite the source and/or the papers properly, and the redistribution of the data must be authorized by the researcher/supervisor. The identity of the person accessing the data will be ascertained with the following questionnaire, there won't be a need for a data access committee., Raw data obtained with nLGAD silicon detectors fabricated at IMB-CNM-CSIC for the paper: "nLGAD gain response to low-penetrating particles”, Spanish Ministry of Science, Innovation and Universities (MICIU/AEI/10.13039/501100011033/) and by the European Union’s ERDF program “A way of making Europe”. Grant references: CEX2023-001397-M, PID2020-113705RB-C32, PID2021-124660OB-C22, PDC2021-121718-C32 and PDC2023-145925-C32 European Union’s Horizon 2020 Research and Innovation. Grant Agreement No. 101004761 (AIDAInnova) NextGenerationEU, Spain (PRTR-C17.I1). CNA is also partially funded by the ASTRO21/1.1/1 (European Union- NextGenerationEU, the Ministry of Science, Innovation and Universities, Recovery Plan, Transformation and Resilience, Spain, the Department of University, Research and Innovation of the Junta de Andalucia and the University of Sevilla)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

The Effects of High-Energy Carbon Co-Doping on IMB-CNM LGAD Fabrication and Performance

  • Villegas, Jairo
  • Dougados, Florent
  • Torres Muñoz, Carmen
  • Fernández-Martínez, Pablo
  • Jiménez-Ramos, M. C.
  • Hidalgo, Salvador
This article belongs to the Special Issue Advances in Radiation Sensors and Detectors., Over the past few years, Low-Gain Avalanche Detectors (LGADs) have demonstrated excellent timing performance, showing great potential for use in 4D tracking of high-energy charged particles. Carbon co-doping is a key factor for enhancing LGAD performance, which are detectors with intrinsic amplification, in harsh radiation environments. This work presents a broad pre-irradiation characterization of the latest carbon-co-implanted (or carbonated) LGADs fabricated at IMB-CNM. The results indicate that the addition of carbon reduces the nominal gain of the devices compared with non-carbonated detectors. Furthermore, a comprehensive study is presented on how carbon co-implantation can either enhance or suppress the diffusion of the multiplication layer during LGAD fabrication, depending on the device structure and fabrication parameters., This work was funded by the Spanish Ministry of Science, Innovation, and Universities (MICIU/AEI/10.13039/501100011033/) and by the European Union’s ERDF program “A way of making Europe”, under grant numbers CEX2023-001397-M, PID2023-148418NB-C42, PID2023-148418NB-C44, and PDC2023-145925-C32. M. Carmen Jimenez-Ramos acknowledges the support for this work through a VI PPIT-US contract. This investigation was also partially financed by the project ref. ASTRO21/1.1/1, with financing from the European Union NextGenerationEU; the Ministry of Science, Innovation, and Universities; the Recovery, Transformation, and Resilience Plan; the Department of University, Research, and Innovation of the Junta de Andalucía; and the University of Sevilla. P. Fernandez-Martinez was funded by the Programa Ramon y Cajal of the Spanish Agencia Estatal de Investigación, under grant RYC2022-037296-I., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Gain Response and Ion Beam-Induced Donor Removal in nLGAD Detector: Global Gain Quenching

  • Manojlovic, Milos
  • Crnjac, Andreo
  • Moffat, Neil
  • Villegas, Jairo
  • Pintilie, Ioana
  • Cabruja, Enric
  • Pellegrini, Giulio
  • Hidalgo, Salvador
This study investigates the response of n-type low-gain avalanche detectors (nLGADs) to local ion-beam irradiation with low-penetrating 1.285-MeV gallium ions, focusing on charge collection efficiency (CCE) and gain degradation. Using the transient current technique (TCT), we present charge collection maps before and after local irradiation. A 404-nm blue laser was used in postcharacterization, with no signal detected in the damaged zones after irradiation, suggesting significant charge trapping. The results reveal a pronounced vulnerability of nLGADs, with significant gain loss observed at fluences as low as 4 × 10<sup>9</sup> ions/cm<sup>2</sup>. This study confirms that a donor removal mechanism occurs at low fluences, and we hypothesize that this effect is linked to a vacancy-mediated mechanism. In addition, we report a global reduction in CCE, suggesting a long-range impact on electric field triggered by local defects. This phenomenon is referred to as the global gain quenching (GGQ). Simulations of the electric field provide further confirmation of GGQ’s occurrence., This work was supported in part by the Spanish Ministry of Science, Innovation and Universities, under Grant MICIU/AEI/10.13039/501100011033; in part by the European Regional Development Fund (ERDF) Program “A Way of Making Europe” under Grant CEX2023-001397-M, Grant PID2021-124660OB-C22, Grant DC2021-121718-C32, Grant PID2023-148418NB-C42, and Grant PDC2023-145925-C32; and in part by the European Union’s Horizon 2020 Research and Innovation Funding Program (AIDAInnova) under Grant Agreement 101004761 and Project IFA-CERN 07/2024., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Studies on the effect of low-fluence proton and neutron irradiation on n-type LGADs

  • Kraus, Veronika
  • Fernández-García, Marcos
  • Hidalgo, Salvador
  • Moll, Michael
  • Villegas, Jairo
Data will be made available on request., The presented study investigates the effects of fluences from 5 x 1012 up to 1 x 1014 particles/cm of 60 MeV proton and neutron irradiation on n-type Low Gain Avalanche Detectors (nLGADs). An nLGAD is a silicon sensor with a highly doped gain layer that enables controlled charge multiplication via impact ionization. In contrast to the well-established p-type LGADs for high-energy physics (HEP) applications, nLGADs are optimized for the detection of low-penetrating particles such as UV photons and soft X-rays. In addition to studying their potential application in environments with radiation backgrounds, these novel devices also enable the exploration of the underlying phenomenology arising from the combination of n-type bulk material with a gain layer, which degradation was previously studied predominantly in the context of p-type LGADs. The irradiation effects were characterized through measurements of the leakage current and capacitance with increasing bias voltage (I–V and C–V), revealing systematic and fluence-dependent behavior related to space charge sign inversion (SCSI) of the n-type bulk material, which especially alters the electric field in the sensor and thus the depletion behavior. Additionally, annealing studies were performed to assess both beneficial and reverse annealing regimes with isothermal and isochronal annealing. The findings are consistent with previous high-energy proton studies and contribute to a deeper understanding of the fundamental behavior of nLGADs under irradiation., This work has received support from the European Union’s Horizon Europe Research and Innovation Programme under Grant Agreement No. 101057511 (EURO-LABS). We gratefully acknowledge IMB-CNM for providing the samples, which have received funding from the Spanish Ministry of Science, Innovation and Universities (MICIU/AEI/10.13039/501100011033) through the grants PID2020-113705RB-C32, PID2023-148418NB-C42, and PDC2023-145925-C32., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Effects of neutron irradiation on LGADs with broad multiplication layer and varied carbon-enriched doses: A study on timing performance and gain deterioration

  • Navarrete Ramos, Efrén
  • Villegas, Jairo
  • Duarte Campderros, J.
  • Fernández-García, Marcos
  • Gómez-Carrera, A.
  • Gómez, Gervasio
  • González, Javier
  • Hidalgo, Salvador
  • Jaramillo, R.
  • Martínez Ruiz del Arbol, P.
  • Merlos Domingo, Ángel
  • Quintana San Emeterio, Cristian
  • Vila, Iván
Data will be made available on request., In this radiation tolerance study, Low Gain Avalanche Detectors (LGADs) with a carbon-enriched broad and shallow multiplication layer were examined in comparison to identical non-carbonated LGADs. Manufactured at IMB-CNM, the sensors underwent neutron irradiation at the TRIGRA reactor in Ljubljana, reaching a fluence of 2.5 × 1015 neq cm-2. The results revealed a smaller deactivation of Boron and improved resistance to radiation in carbonated LGADs. The study demonstrated the potential benefits of carbon enrichment in mitigating radiation damage effects, particularly the acceptor removal mechanism, reducing the acceptor removal constant by more than a factor of two. Additionally, time resolution and collected charge degradation due to irradiation were observed, with carbonated samples exhibiting better radiation tolerance. A noise analysis focused on baseline noise and thermally generated pulses showed the presence of spurious thermal-generated pulses attributed to a excessive small distance between the gain layer end and the p-stop implant at the periphery of the pad for the characterized LGAD design; however, the operation performance of the devices was unaffected., This work was developed in the framework of the CERN DRD3 collaboration and has been funded by the Spanish Ministry of Science and Innovation (MICIU/AEI/10.13039/501100011033/) and by the European Union’s ERDF program “A way of making Europe”. Grant references: CEX2023-001397-M, PID2023-148418NB-C41, PID2023-148418NB-C42, PDC2023-145925-C31 and PDC2023-145925-C32. Also, it was supported by the European Union’s Horizon 2020 Research and Innovation funding program (Grant Agreement No. 101004761, AIDAInnova)., This work has also been supported by the European Union NextGenerationEU/PRTR project C17.I02.P02 - SGI_GICS_Nuevas actuaciones en grandes infraestructuras de investigación europeas e internacionales, the Complementary Plan in Astrophysics and High-Energy Physics (CA25944), project C17.I02.P02.S01.S03 CSIC CERN, funded by the Next Generation EU funds, RRF and PRTR funds, and the Autonomous Community of Cantabria., This work has been developed in the framework of the Grant RyC-2023-044327-I funded by the Spanish Ministry of Science, Innovation and Universities (MICIU/AEI/10.13039/501100011033) and by FSE+, and co-funded by the European Social Fund program “El FSE invierte en tu futuro” with grant reference: PRE2019-087514., With funding from the Spanish government through the "Severo Ochoa Centre of Excellence" accreditation (CEX2023-001397-M)., Peer reviewed