DESARROLLO DE SOLUCIONES PARA EL APANTALLAMIENTO Y TRATAMIENTO DEL GAS RADON EN ESPACIOS INTERIORES HABITABLES

PID2021-125345OA-I00

•
Funding agency name Agencia Estatal de Investigación
Funding agency acronym AEI
Program Programa Estatal para Impulsar la Investigación Científico-Técnica y su Transferencia
Subprogram Subprograma Estatal de Generación de Conocimiento
Call Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Call year 2021
State Plan 2021-2023 Plan Estatal de Investigación Científica y Técnica y de Innovación
Beneficiary centre UNIVERSITAT POLITÈCNICA DE VALÈNCIA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 6
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Research data Set de datos (Dataset)

Commercial paints as indoor radon barriers dataset

  • García-Gimeno, Belén|||0009-0002-7400-0655
  • Ruvira-Quintana, Beatriz|||0000-0002-9108-1197
  • García-Fayos, Beatriz|||0000-0002-7941-4243
  • Arnal Arnal, José Miguel
This dataset contains the experimental data generated during the evaluation of six commercially available paints as potential indoor radon barriers. It includes the raw radon concentration measurements recorded in the source and receiver chambers during 48-hour diffusion tests performed on filter paper substrates coated with a single coat of each paint, the main specifications of the experimental set-up used to perform the measurements, and the thickness measurements of the coated samples. The experimental data were used to determine the radon concentration reduction and the radon diffusion coefficient following a modified version of the ISO/TS 11665-13:2017 standard, as reported in the associated conference contribution. The experimental data were generated using a two-chamber radon diffusion test following a modified version of ISO/TS 11665-13:2017. The experimental set-up consisted of two sealed AISI 316L stainless steel chambers separated by the test sample. A sealed pitchblende stone (1.469 kBq) was placed inside the source chamber, while the receiver chamber collected the radon that permeated through the sample. Radon concentration in both chambers was continuously monitored using two Durridge RAD7 detectors connected in closed-loop circuits. Temperature and relative humidity were monitored throughout the experiments. Six commercially available water-based decorative paints were evaluated by applying a single coat of each paint onto a filter paper substrate. Two independent diffusion tests were performed for each paint. Each test lasted 48 hours, during which radon concentrations in the source and receiver chambers were recorded at 30-minute intervals. These raw experimental data were subsequently used to determine the radon concentration reduction and the radon diffusion coefficient following the procedure described in ISO/TS 11665-13:2017. The dataset also includes the main specifications of the experimental set-up, such as chamber characteristics, radon source activity and test area. The thickness of each coated sample was determined from eight measurements taken at different locations , from which the mean thickness and the standard deviation were calculated. The radon concentration data recorded by the RAD7 detectors at 30-minute intervals were exported. For each experiment, the dataset includes the test date and the radon concentration values measured in the source and receiver chambers throughout the 48-hour test. No additional processing, filtering or normalization was applied to the concentration data before their inclusion in the dataset. The experimental set-up specifications were compiled from the laboratory protocol used during the diffusion tests. For the thickness data, the reported mean thickness and standard deviation were calculated from eight thickness measurements taken at different locations on each coated sample.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Research data Set de datos (Dataset)

Configuration of laminated wastes as radon barriers dataset

  • Ruvira-Quintana, Beatriz|||0000-0002-9108-1197
  • García-Gimeno, Belén|||0009-0002-7400-0655
  • García-Fayos, Beatriz|||0000-0002-7941-4243
  • Arnal Arnal, José Miguel
This dataset contains the experimental data generated during the evaluation of two configurations of laminated wastes, composed of polymeric and aluminium materials, as potential radon barriers for indoor spaces. It includes the raw radon concentration measurements recorded in the source and receiver chambers during 48-hour diffusion tests for each configuration, the main specifications of the experimental set-up used to perform the measurements, and the thickness of the laminated waste samples used in the study. The experimental data were used to calculate the radon concentration reduction and the radon diffusion coefficient, following a modified version of the ISO/TS 11665–13:2017 standard, as reported in the associated publication. The experimental data were generated using a two-chamber radon diffusion test following a modified version of ISO/TS 11665-13:2017. The experimental set-up consisted of two sealed AISI 316L stainless steel chambers separated by the test sample. A sealed pitchblende stone (1.469 kBq) was placed inside the source chamber, while the receiver chamber collected the radon that permeated through the sample. Radon concentration in both chambers was continuously monitored using two Durridge RAD7 detectors connected in closed-loop circuits. Temperature and relative humidity were monitored throughout the experiments. Each test lasted 48 hours, during which radon concentrations in the source and receiver chambers were recorded at 30-minute intervals. These raw experimental data were subsequently used to calculate the radon concentration reduction and the radon diffusion coefficient following the procedure described in ISO/TS 11665-13:2017. The dataset also includes the main specifications of the experimental set-up, such as chamber characteristics, radon source activity and test area. The thickness of each laminated waste sample was determined from eight measurements taken at different locations on the sample, from which the mean thickness and the standard deviation were calculated. Following the recommendations of the ISO/TS 11665-13:2017, the thickness of materials installed with an overlap is the same as that of the material unbound, provided that the length on each side of the overlap exceeds the width of the overlap by at least 2 cm. The radon concentration data recorded by the RAD7 detectors at 30-minute intervals were exported. For each experiment, the dataset includes the test date and the radon concentration values measured in the source and receiver chambers throughout the 48-hour test. No additional processing, filtering or normalization was applied to the concentration data before their inclusion in the dataset. The experimental set-up specifications were compiled from the laboratory protocol used during the diffusion tests. For the thickness data, the reported mean thickness and standard deviation were calculated from eight thickness measurements taken at different locations on each laminated waste sample.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Research data Set de datos (Dataset)

Phosphogypsum barrier materials dataset

  • García-Gimeno, Belén|||0009-0002-7400-0655
  • Ruvira-Quintana, Beatriz|||0000-0002-9108-1197
  • García-Fayos, Beatriz|||0000-0002-7941-4243
  • Arnal Arnal, José Miguel
This dataset contains the experimental data generated during the evaluation of different materials as potential barriers against radon released from phosphogypsum. It includes the raw radon concentration measurements recorded in the source and receiver chambers during 148.5-hour tests, the main specifications of the experimental set-up used to perform the measurements, and the thickness measurements of the tested materials. The experimental data were used to determine the radon concentration reduction achieved by each material, as reported in the associated conference proceedings paper. The experimental data were generated using a two-chamber experimental set-up designed in accordance with ISO/TS 11665-13:2017 to evaluate the effectiveness of different materials as barriers against radon released from phosphogypsum. It consisted of two sealed AISI 316L stainless steel chambers (2 mm thickness, 0.801 L volume and 78.5 cm² test area) separated by the test sample. Phosphogypsum with an activity of 2.29 Bq was placed inside the source chamber, while the receiver chamber collected the radon that permeated through the sample. Radon concentration in both chambers was continuously monitored using two Durridge RAD7 detectors. Ten different materials were evaluated. Each test lasted 148.5 hours, during which radon concentrations in the source and receiver chambers were recorded at 1.5 hour intervals. These raw experimental data were used to determine the percentage reduction in radon concentration achieved by each material. The radon concentration data recorded by the RAD7 detectors at 1.5 hour intervals were exported. For each experiment, the dataset includes the test date and the radon concentration values measured in the source and receiver chambers throughout the 148.5 hour test. No additional processing was applied to the concentration data. The experimental set-up specifications were compiled. For the thickness data, the reported mean thickness and standard deviation were calculated from eight thickness measurements taken at different locations on each material. The dataset also includes the main specifications of the experimental set-up, such as chamber characteristics, phosphogypsum activity and test area. The thickness of each material was determined from eight measurements taken at different locations, from which the mean thickness and the standard deviation were calculated.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Research data Set de datos (Dataset)

Commercial wallpapers as radon barriers dataset

  • Ruvira-Quintana, Beatriz|||0000-0002-9108-1197
  • García-Fayos, Beatriz|||0000-0002-7941-4243
  • García-Gimeno, Belén|||0009-0002-7400-0655
  • Arnal Arnal, José Miguel
  • Verdú Martín, Gumersindo Jesús|||0000-0001-5098-080X
This dataset contains the experimental data generated during the evaluation of commercial wallpapers composed of different layers of polymeric and cellulosic materials as potential radon barriers for indoor spaces. It includes the raw radon concentration measurements for a single layer, double layer and double layer with aluminium configuration recorded in the source and receiver chambers during 48-hour diffusion tests, the main specifications of the experimental set-up used to perform the measurements, and the thickness of the laminated waste samples used in the study. The experimental data were used to calculate the radon concentration reduction and the radon diffusion coefficient, following a modified version of the ISO/TS 11665–13:2017 standard, as reported in the associated publication. The experimental data were generated using a two-chamber radon diffusion test following a modified version of ISO/TS 11665-13:2017. The experimental set-up consisted of two sealed AISI 316L stainless steel chambers separated by the test sample. A sealed pitchblende stone (1.469 kBq) was placed inside the source chamber, while the receiver chamber collected the radon that permeated through the sample. Radon concentration in both chambers was continuously monitored using two Durridge RAD7 detectors connected in closed-loop circuits. Temperature and relative humidity were monitored throughout the experiments. Each test lasted 48 hours, during which radon concentrations in the source and receiver chambers were recorded at 30-minute intervals. These raw experimental data were subsequently used to calculate the radon concentration reduction and the radon diffusion coefficient following the procedure described in ISO/TS 11665-13:2017. The dataset also includes the main specifications of the experimental set-up, such as chamber characteristics, radon source activity and test area. The thickness of each wallpaper sample was determined from eight measurements taken at different locations on the sample, from which the mean thickness and the standard deviation were calculated. The radon concentration data recorded by the RAD7 detectors at 30-minute intervals were exported. For each experiment, the dataset includes the test date and the radon concentration values measured in the source and receiver chambers throughout the 48-hour test. No additional processing, filtering or normalization was applied to the concentration data before their inclusion in the dataset. The experimental set-up specifications were compiled from the laboratory protocol used during the diffusion tests. For the thickness data, the reported mean thickness and standard deviation were calculated from eight thickness measurements taken at different locations on each laminated waste sample.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Research data Set de datos (Dataset)

Laminated wastes as radon barriers dataset

  • Ruvira-Quintana, Beatriz|||0000-0002-9108-1197
  • García-Fayos, Beatriz|||0000-0002-7941-4243
  • Juste-Vidal, Belen-Jeanne|||0000-0003-1978-3765
  • Arnal Arnal, José Miguel
  • Verdú Martín, Gumersindo Jesús|||0000-0001-5098-080X
Nowadays, there is a severe problem with waste generation, especially with single-use packaging. Although the trend is to try to recycle or reuse this waste, a significant amount still ends up in landfills, which represents a serious environmental problem. This waste includes laminated materials, which are difficult to recycle because the polymeric material and aluminium layers cannot be separated easily. This work proposes the study of the valorisation of several laminated wastes as radon barriers for indoor spaces due to the similarity in composition between these waste and commercial radon barriers. This dataset contains the experimental data generated during the evaluation of laminated wastes composed of polymeric and aluminium materials as potential radon barriers for indoor spaces. It includes the raw radon concentration measurements recorded in the source and receiver chambers during 48-hour diffusion tests, the main specifications of the experimental set-up used to perform the measurements, and the thickness of the laminated waste samples used in the study. The experimental data were used to calculate the radon concentration reduction and the radon diffusion coefficient, following a modified version of the ISO/TS 11665–13:2017 standard, as reported in the associated publication., This work is financed by grant SUB-33/2021 funded by the Spanish Nuclear Safety Council for laminated wastes, and by grant PID2021-125345OA-I00 funded by MCIN/AEI/10.13039/501100011033 and by “ERDF A way of making Europe” for metallised wastes. B.Ruvira was funded by a pre-doctoral grant from the CSN-UPV "Vicente Serradell" Chair. The authors would like to thank GDES for their collaboration during the research.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Research data Set de datos (Dataset)

Methodology application vinyl paint as a radon barrier dataset

  • García-Gimeno, Belén|||0009-0002-7400-0655
  • Ruvira-Quintana, Beatriz|||0000-0002-9108-1197
  • García-Fayos, Beatriz|||0000-0002-7941-4243
  • Arnal Arnal, José Miguel
  • Cardona, S. C.|||0000-0002-2882-3098
  • Verdú Martín, Gumersindo Jesús|||0000-0001-5098-080X
This dataset contains the experimental data generated during the development and evaluation of a methodology for applying a commercially available water-based vinyl paint as a radon mitigation barrier for indoor spaces. It includes the raw radon concentration measurements recorded in the source and receiver chambers during diffusion tests performed on samples coated with different numbers of paint coats and paint coat thicknesses. The dataset also includes experimental results obtained using a commercially available anti-radon paint as a reference material for comparison, together with the main specifications of the experimental set-up and the thickness measurements of the paint coats. These experimental data were used to determine the radon concentration reduction and the radon diffusion coefficient following a modified version of the ISO/TS 11665-13:2017 standard, as reported in the associated publication. The experimental data were generated using a two-chamber radon diffusion test following a modified version of ISO/TS 11665-13:2017. The experimental set-up consisted of two sealed AISI 316L stainless steel chambers separated by the test sample. A sealed pitchblende stone (1.469 kBq) was placed inside the source chamber, while the receiver chamber collected the radon that permeated through the sample. Radon concentration in both chambers was continuously monitored using two Durridge RAD7 detectors connected in closed-loop circuits. Temperature and relative humidity were monitored throughout the experiments. Each test lasted 48 hours, during which radon concentrations in the source and receiver chambers were recorded at 30-minute intervals. These raw experimental data were subsequently used to calculate the radon concentration reduction and the radon diffusion coefficient following the procedure described in ISO/TS 11665-13:2017. The dataset also includes the main specifications of the experimental set-up, such as chamber characteristics, radon source activity and test area. The thickness of each paint coat was determined from eight measurements taken at different locations on the coated sample, from which the mean thickness and the standard deviation were calculated. The radon concentration data recorded by the RAD7 detectors at 30-minute intervals were exported. For each experiment, the dataset includes the test date and the radon concentration values measured in the source and receiver chambers throughout the 48-hour test. No additional processing, filtering or normalization was applied to the concentration data before their inclusion in the dataset. The experimental set-up specifications were compiled from the laboratory protocol used during the diffusion tests. For the thickness data, the reported mean thickness and standard deviation were calculated from eight thickness measurements taken at different locations on each coated sample.