Dataset for TED2021 AEI Project: Green chemistry for a membrane-free electrolitic flow battery for large scale energy storage (GreenFloBat)

  • Khabazian, Siavash
  • Liu, Cheng
  • Gao, Yan
  • Vallejo, Victor
  • Martin Diaconescu, Vlad
  • Stievano, Lorenzo
  • Tonti, Dino
Fecha de finalización del proyecto: 2025-08-31 This dataset contains the experimental and computational data generated during the TED2021 project TED2021-132707B-I00 Metodología detallada: ¿Cómo se generaron los datos, incluidos los equipos o el software utilizado, el protocolo experimental, etc? For XAS measurements, the synchrotron radiation emitted by a wiggler source was monochromatized using a double-crystal Si(311) monochromator with an appropriate beam size of 1 mm × 1 mm. Higher harmonics were rejected by choosing the proper angles and coatings for the collimating and focusing mirrors. The absorption data of the Mn and Zn references were collected in transmission mode using three ionization chambers for simultaneous measurements of the sample and the Mn foil used as a reference, within an incoming energy resolution below 0.3 eV. For XES experiments, the incoming beam was monochromatized using a double-crystal Si(311) monochromator and the emission data were collected in back scattering geometry with a beam size of 0.2 mm × 0.1 mm, (parallel to the linear polarization vector of the incoming X-ray beam) by means of the CLEAR emission spectrometer. The spectrometer was based on a dynamically bent diced Si(333) crystal analyzer (bending radius R = 1 m) and a 1D position-sensitive Mythen detector. The emission spectra were acquired by exciting the sample well above the Mn K edge and detecting the emitted Mn Kβ1,3 emission lines, with a total energy resolution of approximately 0.6 eV. Repeated X-ray absorption and emission scans were measured to ensure the reproducibility of the spectra and obtain a high signal-to-noise ratio. The measurements were performed at ambient temperature under vacuum conditions. Operando XAS was operated with a similar configuration to the operando cell in Fig. S1, but the cathode was moved from the center to partly expose the separator, as shown in Fig. 2c, where both Zn and Mn K-edge XAS data were acquired synchronously in both the electrolyte and electrode, respectively. The cell was filled with ca. 60 μL 0.5 M ZnSO4 and 0.2 M MnSO4 electrolyte and operated under a C/10 rate and with a low voltage cut-off of 0.9 V vs. Zn/Zn2+, after being maintained for one hour at Open Circle Voltage (OCV) state. The duration of data acquisition was approximately 30 minutes per batch, including a total of 10 spectra (Zn and Mn spectra in both the electrolyte and cathode), along with a short resting time. In situ STXM. 2 μL of a 20 ppm (w/w) suspension of α-MnO2 in H2O was dropped onto a MEMS chip (HUMMINGBIRD). The chip was then mounted on its flow-cell microscope holder, introduced into the STXM chamber, and connected to a BioLogic SP200 potentiostat. The electrolyte (1 M ZnSO4 and 0.2 M MnSO4) was injected from a 1 mL syringe at a speed of 0.2 mL per hour. During cycling, an energy of 1010 eV near the Zn L-edge was selected to acquire the STXM images to provide an optimal image contrast. Galvanostatic cycling tests were conducted using a LANHE M340A cycler. Remaining electrochemical tests were conducted using a BioLogic VSP potentiostat. X-ray Diffraction (XRD) patterns were collected by a Siemens D-5000 diffractometer of Cu K𝛼 radiation. Operando XRD data were acquired by a Bruker D8 Advance A25 diffractometer in a Debye-Scherrer geometry equipped with a Johansson monochromator of the Mo K𝛼 radiation and its standard transmission diffraction collection mode. Scanning Electron Microscopy (SEM) was performed using a FEI Quanta 200 FEG-ESEM equipment (10 – 15 kV). X-Ray Photoelectron Spectroscopy (XPS) data were recorded by a SPECS EA10P hemispherical analyzer with a monochromatic Al K𝛼 radiation. (Scanning) Transmission Electron Microscopy ((S)TEM) and Transmission Electron Microscopy-Energy Dispersive X-Ray (TEM–EDX) and Scanning Transmission Electron Microscopy–Electron Energy Loss Spectroscopy (STEM–EELS) were acquired with a Super-X EDX spectrometer and a Gatan Continuum K3 EELS spectrometer, or a ThermoFisher Scientific Spectra 300. Spectra were collected at a beam energy of 200 keV with an energy step of 0.9 eV. Mn K-edge X-ray Absorption Spectroscopy (XAS) was carried out at the CLÆSS beamline of ALBA CELLS synchrotron, Spain. Ex situ energy-resolved full-field soft X-ray Transmission Microscopy (TXM) was performed at the MISTRAL beamline of ALBA CELLS Synchrotron, Spain.84 In situ Scanning X-ray Transmission Microscopy (STXM) was carried out at the DEMETER beamline of SOLARIS Synchrotron, Poland. The STXM images were obtained at the energy of ca. 1010 eV to optimize the compromise between contrast and radiation damage. XPS fitting was carried out with CasaXPS for Mn 2p3/2, K 2p, and O 1s lines following the procedure described in our previous report.56 For XAS techniques, the Zn and Mn mole evolutions in the electrode and electrolyte of the operando cell were calculated from the X-ray Absorption Near Edge Structure (XANES) edge jumps with a self-built model detailed in the Supporting Information. The EXAFS portion of the operando XAS data was analyzed using ATHENA and ARTEMIS. For the fitting of the pre-edge, the baseline was modeled with the Larch package. The MnO2 and Mn2O3 reference spectra were taken as models of Mn(IV) and Mn(III) components, respectively, using the Hyperspy package. For XES measurements, a linear background was subtracted in SpectroChemPy,93 considering 0.5 – 2 eV of the low- and high-energy tails. Subsequently, each spectrum was normalized to its area. The Integrated Absolute Difference (IAD) with respect to a low-spin reference method was utilized to extract the local magnetic moment quantitatively. The ex situ TXM data were processed following previous work. In situ STXM images and Mn spectra were obtained in aXis2000.99 (S)TEM-related dataset (HRTEM, STEM–HAADF images, TEM–EDX, and STEM–EELS) were treated with eXSpy., Affordable Zn and safe aqueous electrolytes make Zn/MnO₂ batteries promising, but common test conditions hide reversibility issues. Recent work shows Mn(IV) can reduce to Mn(II) in flow cells, and Zn/MnO₂ can be deposited during charging from Zn²⁺/Mn²⁺ solutions, achieving high energy density without ion-selective membranes—cutting cost and risk. The mechanism is complex and poorly understood, involving intercalation, precipitation, and dissolution driven by pH, plus side reactions like corrosion and Zn dendrites. We propose advanced techniques (e.g., X-ray absorption) to identify chemical species and compare main vs. undesired processes under varying electrode designs, additives, and conditions. This will guide development of sustainable, low-cost, scalable Zn-MnO₂ flow batteries., Proyecto TED2021-132707B-I00 financiado por AEI/MCIN, - /data/raw: Original unprocessed data - /data/processed: Derived results - /code: Scripts used for analysis and for simulations - /other: Supplementary files, No